Optimizing robot motion for robotic ultrasound-guided radiation therapy.

Abstract:

:An important aspect of robotic radiation therapy is active compensation of target motion. Recently, ultrasound has been proposed to obtain real-time volumetric images of abdominal organ motion. One approach to realize flexible probe placement throughout the treatment fraction is based on a robotic arm holding the ultrasound probe. However, the probe and the robot holding it may obstruct some of the beams with a potentially adverse effect on the plan quality. This can be mitigated by using a kinematically redundant robot, which allows maintaining a steady pose of the ultrasound probe while moving its elbow in order to minimize beam blocking. Ultimately, the motion of both the beam source carrying and the ultrasound probe holding robot contributes to the overall treatment time, i.e. beam delivery and robot motion. We propose an approach to optimize the motion and coordination of both robots based on a generalized traveling salesman problem. Furthermore, we study an application of the model to a prostate treatment scenario. Because the underlying optimization problem is hard, we compare results from a state-of-the-art heuristic solver and an approximation scheme with low computational effort. Our results show that integration of the robot holding the ultrasound probe is feasible with acceptable overhead in overall treatment time. For clinically realistic velocities of the robots, the overhead is less than 4% which is a small cost for the added benefit of continuous, volumetric, and non-ionizing tracking of organ motion over periodic x-ray-based tracking.

journal_name

Phys Med Biol

authors

Schlüter M,Fürweger C,Schlaefer A

doi

10.1088/1361-6560/ab3bfb

subject

Has Abstract

pub_date

2019-10-04 00:00:00

pages

195012

issue

19

eissn

0031-9155

issn

1361-6560

journal_volume

64

pub_type

杂志文章
  • In vivo evaluation of the elastic anisotropy of the human Achilles tendon using shear wave dispersion analysis.

    abstract::Non-invasive evaluation of the Achilles tendon elastic properties may enhance diagnosis of tendon injury and the assessment of recovery treatments. Shear wave elastography has shown to be a powerful tool to estimate tissue mechanical properties. However, its applicability to quantitatively evaluate tendon stiffness is...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/3/505

    authors: Brum J,Bernal M,Gennisson JL,Tanter M

    更新日期:2014-02-07 00:00:00

  • A new optimal wavelength for treatment of port wine stains?

    abstract::In this study we investigate light penetration into skin in order to define the optimal wavelength for the treatment of port wine stains. A two-layer model (epidermis and dermis) is applied with a cylindric tube representing the ectatic blood vessel. Light propagation is calculated by the Monte Carlo method. Values fo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/10/001

    authors: Kienle A,Hibst R

    更新日期:1995-10-01 00:00:00

  • HeinzelCluster: accelerated reconstruction for FORE and OSEM3D.

    abstract::Using iterative three-dimensional (3D) reconstruction techniques for reconstruction of positron emission tomography (PET) is not feasible on most single-processor machines due to the excessive computing time needed, especially so for the large sinogram sizes of our high-resolution research tomograph (HRRT). In our fir...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/15/307

    authors: Vollmar S,Michel C,Treffert JT,Newport DF,Casey M,Knöss C,Wienhard K,Liu X,Defrise M,Heiss WD

    更新日期:2002-08-07 00:00:00

  • Effects of particle diameter and magnetocrystalline anisotropy on magnetic relaxation and magnetic particle imaging performance of magnetic nanoparticles.

    abstract::The dynamic magnetization of immobilized spherical single-domain magnetic nanoparticles (MNPs) with uniaxial or cubic magnetocrystalline anisotropy was studied computationally by executing simulations based on the Landau-Lifshitz-Gilbert (LLG) equation. For situations when a static magnetic field was suddenly applied ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab5b83

    authors: Zhao Z,Garraud N,Arnold DP,Rinaldi C

    更新日期:2020-01-17 00:00:00

  • Development and validation of RAYDOSE: a Geant4-based application for molecular radiotherapy.

    abstract::We developed and validated a Monte-Carlo-based application (RAYDOSE) to generate patient-specific 3D dose maps on the basis of pre-treatment imaging studies. A CT DICOM image is used to model patient geometry, while repeated PET scans are employed to assess radionuclide kinetics and distribution at the voxel level. In...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/8/2491

    authors: Marcatili S,Pettinato C,Daniels S,Lewis G,Edwards P,Fanti S,Spezi E

    更新日期:2013-04-21 00:00:00

  • Comparison between TG-51 and TRS-398: electron contamination effect on photon beam-quality specification.

    abstract::Two dosimetry protocols based on absorbed dose to water have recently been implemented: TG-51 and TRS-398. These protocols use different beam-quality indices: %dd(10)x and TPR20,10. The effect of electron contamination in measurements of %dd(10)x has been proposed as a disadvantage of the TG-51. For actual measurement...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/1/002

    authors: Lopez Medina A,Teijeiro A,Salvador F,Medal D,Vazquez J,Salgado M,Carrion MC

    更新日期:2004-01-07 00:00:00

  • Investigation of practical approaches to evaluating cumulative dose for cone beam computed tomography (CBCT) from standard CT dosimetry measurements: a Monte Carlo study.

    abstract::A function called Gx(L) was introduced by the International Commission on Radiation Units and Measurements (ICRU) Report-87 to facilitate measurement of cumulative dose for CT scans within long phantoms as recommended by the American Association of Physicists in Medicine (AAPM) TG-111. The Gx(L) function is equal to t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/14/5413

    authors: Abuhaimed A,Martin CJ,Sankaralingam M,Gentle DJ

    更新日期:2015-07-21 00:00:00

  • Impact of high dose volumetric CT on PTV margin reduction in VMAT prostate radiotherapy.

    abstract::The aim of the study is to determine PTV margin for inter-observer variability in the volumetric modulated arc therapy (VMAT) prostate radiotherapy with high-dose volumetric CT (HDVCT) and conventional helical CT (CCT) for planning. Secondly to investigate the impact of geometric (PTV expansion) and dosimetric (confor...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab050f

    authors: Cho YB,Alasti H,Kong V,Catton C,Berlin A,Chung P,Bayley A,Jaffray D

    更新日期:2019-03-14 00:00:00

  • The recombination correction for an ionisation chamber exposed to pulsed radiation in a 'swept beam' technique. I. Theory.

    abstract::The established theory for the collection efficiency of an ionisation chamber irradiated by a series of uniform short pulses is extended to the more complex case of irradiation in a pulsed and electromagnetically swept electron beam. The radial variation of exposure rate is assumed to be Gaussian with scale constant e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/27/2/001

    authors: Boag JW

    更新日期:1982-02-01 00:00:00

  • The effective attenuation coefficient of soft tissue in the presence of Compton scattering from bone: experiments on models.

    abstract::Calibration methods are investigated for the determination of bone density by the Compton scattering method. The scattered radiation from materials of different densities and dimensions is measured for this purpose. A function for the dependence of the intensity on these parameters is derived and compared with the exp...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/4/009

    authors: Leichter I,Weinreb A,Hazan G

    更新日期:1980-07-01 00:00:00

  • Assessment of the accuracy of an MCNPX-based Monte Carlo simulation model for predicting three-dimensional absorbed dose distributions.

    abstract::In recent years, the Monte Carlo method has been used in a large number of research studies in radiation therapy. For applications such as treatment planning, it is essential to validate the dosimetric accuracy of the Monte Carlo simulations in heterogeneous media. The AAPM Report no 105 addresses issues concerning cl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/16/016

    authors: Titt U,Sahoo N,Ding X,Zheng Y,Newhauser WD,Zhu XR,Polf JC,Gillin MT,Mohan R

    更新日期:2008-08-21 00:00:00

  • Quenching-free fluorescence signal from plastic-fibres in proton dosimetry: understanding the influence of Čerenkov radiation.

    abstract::The origin of photons emitted in optical fibres under proton irradiation has been attributed to either entirely Čerenkov radiation or light consisting of fluorescence with a substantial amount of Čerenkov radiation. The source of the light emission is assessed in order to understand why the signal from optical fibres ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaafad

    authors: Brage Christensen J,Almhagen E,Nyström H,Andersen CE

    更新日期:2018-03-09 00:00:00

  • ALGEBRA: ALgorithm for the heterogeneous dosimetry based on GEANT4 for BRAchytherapy.

    abstract::Task group 43 (TG43)-based dosimetry algorithms are efficient for brachytherapy dose calculation in water. However, human tissues have chemical compositions and densities different than water. Moreover, the mutual shielding effect of seeds on each other (interseed attenuation) is neglected in the TG43-based dosimetry ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/11/3273

    authors: Afsharpour H,Landry G,D'Amours M,Enger S,Reniers B,Poon E,Carrier JF,Verhaegen F,Beaulieu L

    更新日期:2012-06-07 00:00:00

  • Effects of pulmonary inhalation on hyperpolarized krypton-83 magnetic resonance T1 relaxation.

    abstract::The (83)Kr magnetic resonance (MR) relaxation time T(1) of krypton gas in contact with model surfaces was previously found to be highly sensitive to surface composition, surface-to-volume ratio, and surface temperature. The work presented here explored aspects of pulmonary (83)Kr T(1) relaxation measurements in excise...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/13/001

    authors: Stupic KF,Elkins ND,Pavlovskaya GE,Repine JE,Meersmann T

    更新日期:2011-07-07 00:00:00

  • Automatic extraction of pectoral muscle in the MLO view of mammograms.

    abstract::A mammogram is the standard modality used for breast cancer screening. Computer-aided detection (CAD) approaches are helpful for improving breast cancer detection rates when applied to mammograms. However, automated analysis of a mammogram often leads to inaccurate results in the presence of the pectoral muscle. There...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/23/8493

    authors: Feudjio CK,Klein J,Tiedeu A,Colot O

    更新日期:2013-12-07 00:00:00

  • Iterative deblurring algorithm for a multiplane tomographic scanner.

    abstract::An iterative algorithm has been developed to reduce blur artefacts in images obtained from the Pho/Con multiplane tomographic scanner. In this technique estimates of the activity distribution are convolved with the detector response function and compared with the original blurred image planes. Successive estimates of ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/7/004

    authors: Zenari A,Hooper RH,Osborne N,Scrimger JW

    更新日期:1985-07-01 00:00:00

  • The noise navigator: a surrogate for respiratory-correlated 4D-MRI for motion characterization in radiotherapy.

    abstract::Respiratory-correlated 4D-MRI can characterize respiratory-induced motion of tumors and organs-at-risk for radiotherapy treatment planning and is a necessity for image guidance of moving tumors treated on an MRI-linac. Essential for 4D-MRI generation is a robust respiratory surrogate signal. We investigated the feasib...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab5c62

    authors: Navest RJM,Mandija S,Bruijnen T,Stemkens B,Tijssen RHN,Andreychenko A,Lagendijk JJW,van den Berg CAT

    更新日期:2020-01-13 00:00:00

  • Bilinear models for inter- and intra-patient variation of the prostate.

    abstract::We propose bilinear models for capturing and effectively decoupling the expected shape variations of an organ both across the patient population and within a specific patient. Bilinear models have been successfully introduced in other areas of computer vision, but they have rarely been used in medical imaging applicat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/13/010

    authors: Jeong Y,Radke RJ,Lovelock DM

    更新日期:2010-07-07 00:00:00

  • Effect of errors in the system matrix on maximum a posteriori image reconstruction.

    abstract::Statistically based iterative image reconstruction methods have been developed for emission tomography. One important component in iterative image reconstruction is the system matrix, which defines the mapping from the image space to the data space. Several groups have demonstrated that an accurate system matrix can i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/14/007

    authors: Qi J,Huesman RH

    更新日期:2005-07-21 00:00:00

  • Super-resolution reconstruction of 4D-CT lung data via patch-based low-rank matrix reconstruction.

    abstract::Lung 4D computed tomography (4D-CT), which is a time-resolved CT data acquisition, performs an important role in explicitly including respiratory motion in treatment planning and delivery. However, the radiation dose is usually reduced at the expense of inter-slice spatial resolution to minimize radiation-related heal...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa8a48

    authors: Fang S,Wang H,Liu Y,Zhang M,Yang W,Feng Q,Chen W,Zhang Y

    更新日期:2017-10-03 00:00:00

  • A low cost method for hard x-ray grating interferometry.

    abstract::Grating interferometry is advantageous over conventional x-ray absorption imaging because it enables the detection of samples constituted by low atomic number elements (low-Z materials). Therefore, it has a potential application in biological science and medical diagnostics. The grating interferometry has some critica...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/23/8266

    authors: Du Y,Lei Y,Liu X,Huang J,Zhao Z,Guo J,Li J,Niu H

    更新日期:2016-12-07 00:00:00

  • In vivo dosimetry in the urethra using alanine/ESR during (192)Ir HDR brachytherapy of prostate cancer--a phantom study.

    abstract::A phantom study for dosimetry in the urethra using alanine/ESR during (192)Ir HDR brachytherapy of prostate cancer is presented. The measurement method of the secondary standard of the Physikalisch-Technische Bundesanstalt had to be slightly modified in order to be able to measure inside a Foley catheter. The absorbed...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/9/022

    authors: Anton M,Wagner D,Selbach HJ,Hackel T,Hermann RM,Hess CF,Vorwerk H

    更新日期:2009-05-07 00:00:00

  • SNR and noise measurements for medical imaging: I. A practical approach based on statistical decision theory.

    abstract::A method of measuring the image quality of medical imaging equipment is considered within the framework of statistical decision theory. In this approach, images are regarded as random vectors and image quality is defined in the context of the image information available for performing a specified detection or discrimi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/38/1/006

    authors: Tapiovaara MJ,Wagner RF

    更新日期:1993-01-01 00:00:00

  • Pitch dependence of longitudinal sampling and aliasing effects in multi-slice helical computed tomography (CT).

    abstract::In this work, we investigate longitudinal sampling and aliasing effects in multi-slice helical CT. We demonstrate that longitudinal aliasing can be a significant, complicated, and potentially detrimental effect in multi-slice helical CT reconstructions. Multi-slice helical CT scans are generally undersampled longitudi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/15/318

    authors: La Rivière PJ,Pan X

    更新日期:2002-08-07 00:00:00

  • Robust fluence map optimization via alternating direction method of multipliers with empirical parameter optimization.

    abstract::For the treatment planning during intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT), beam fluence maps can be first optimized via fluence map optimization (FMO) under the given dose prescriptions and constraints to conformally deliver the radiation dose to the targets while sparin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/7/2838

    authors: Gao H

    更新日期:2016-04-07 00:00:00

  • Respiratory liver motion estimation and its effect on scanned proton beam therapy.

    abstract::Proton therapy with active scanning beam delivery has significant advantages compared to conventional radiotherapy. However, so far only static targets have been treated in this way, since moving targets potentially lead to interplay effects. For 4D treatment planning, information on the target motion is needed to cal...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/7/1779

    authors: Zhang Y,Boye D,Tanner C,Lomax AJ,Knopf A

    更新日期:2012-04-07 00:00:00

  • Optimizing wavelength choice for quantitative optoacoustic imaging using the Cramer-Rao lower bound.

    abstract::Several papers have recently addressed the issue of estimating chromophore concentration in optoacoustic imaging (OAI) using multiple wavelengths. The choice of wavelengths obviously affects the accuracy and precision of the estimates. One might assume that the wavelengths that maximize the extinction coefficients of ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/23/004

    authors: Modgil D,La Riviére PJ

    更新日期:2010-12-07 00:00:00

  • Characterization of 3D joint space morphology using an electrostatic model (with application to osteoarthritis).

    abstract::Joint space morphology can be indicative of the risk, presence, progression, and/or treatment response of disease or trauma. We describe a novel methodology of characterizing joint space morphology in high-resolution 3D images (e.g. cone-beam CT (CBCT)) using a model based on elementary electrostatics that overcomes a...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/3/947

    authors: Cao Q,Thawait G,Gang GJ,Zbijewski W,Reigel T,Brown T,Corner B,Demehri S,Siewerdsen JH

    更新日期:2015-02-07 00:00:00

  • Local hydrogen clearance as a method for the measurement of capillary blood flow.

    abstract::A hydrogen clearance technique for the measurement of capillary blood flow in skeletal muscle (both resting and working) and the beating heart in experimental animals is described. Various methods for introducing the hydrogen into the region of measurement are compared, together with the appropriate methods for evalua...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/10/005

    authors: Harrison DK,Kessler M

    更新日期:1989-10-01 00:00:00

  • Patch-based anisotropic diffusion scheme for fluorescence diffuse optical tomography--part 2: image reconstruction.

    abstract::Fluorescence diffuse optical tomography (fDOT) provides 3D images of fluorescence distributions in biological tissue, which represent molecular and cellular processes. The image reconstruction problem is highly ill-posed and requires regularisation techniques to stabilise and find meaningful solutions. Quadratic regul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/4/1452

    authors: Correia T,Koch M,Ale A,Ntziachristos V,Arridge S

    更新日期:2016-02-21 00:00:00