Robust principal component analysis-based four-dimensional computed tomography.

Abstract:

:The purpose of this paper for four-dimensional (4D) computed tomography (CT) is threefold. (1) A new spatiotemporal model is presented from the matrix perspective with the row dimension in space and the column dimension in time, namely the robust PCA (principal component analysis)-based 4D CT model. That is, instead of viewing the 4D object as a temporal collection of three-dimensional (3D) images and looking for local coherence in time or space independently, we perceive it as a mixture of low-rank matrix and sparse matrix to explore the maximum temporal coherence of the spatial structure among phases. Here the low-rank matrix corresponds to the 'background' or reference state, which is stationary over time or similar in structure; the sparse matrix stands for the 'motion' or time-varying component, e.g., heart motion in cardiac imaging, which is often either approximately sparse itself or can be sparsified in the proper basis. Besides 4D CT, this robust PCA-based 4D CT model should be applicable in other imaging problems for motion reduction or/and change detection with the least amount of data, such as multi-energy CT, cardiac MRI, and hyperspectral imaging. (2) A dynamic strategy for data acquisition, i.e. a temporally spiral scheme, is proposed that can potentially maintain similar reconstruction accuracy with far fewer projections of the data. The key point of this dynamic scheme is to reduce the total number of measurements, and hence the radiation dose, by acquiring complementary data in different phases while reducing redundant measurements of the common background structure. (3) An accurate, efficient, yet simple-to-implement algorithm based on the split Bregman method is developed for solving the model problem with sparse representation in tight frames.

journal_name

Phys Med Biol

authors

Gao H,Cai JF,Shen Z,Zhao H

doi

10.1088/0031-9155/56/11/002

subject

Has Abstract

pub_date

2011-06-07 00:00:00

pages

3181-98

issue

11

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(11)77629-1

journal_volume

56

pub_type

杂志文章
  • The use of customized spreadsheets in radiation therapy.

    abstract::A number of radiation-therapy-related uses based on a commercially available spreadsheet program have been developed at our facility. The graphics and display capabilities inherent in these spreadsheet programs allow for concise visual results. The spreadsheets are used as an independent check for several types of rad...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/6/007

    authors: Balog JP,Sibata CH,Podgorsak MB,Shin KH

    更新日期:1995-06-01 00:00:00

  • Cadmium in man measured in vivo by x-ray fluorescence analysis.

    abstract::The sensitivity and detection limit for measurements of the concentration of cadmium in the kidney cortex of man in vivo have been investigated using the technique of X-ray fluorescence. An 11 GB1 241Am source was used to generate the characteristic K alpha X-rays of cadmium. The variation in the sensitivity for the d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/26/1/004

    authors: Ahlgren L,Mattsson S

    更新日期:1981-01-01 00:00:00

  • Prediction of dose-volume histograms in nasopharyngeal cancer IMRT using geometric and dosimetric information.

    abstract::A method using both patient geometric and dosimetric information was proposed to predict dose-volume histograms (DVHs) of organs at risk (OARs) for a nasopharyngeal cancer (NPC) intensity-modulated radiation therapy (IMRT) plan. A total of 106 nine-field IMRT NPC plans were used in this study. Twenty-six plans were ra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab50eb

    authors: Jiao SX,Chen LX,Zhu JH,Wang ML,Liu XW

    更新日期:2019-12-05 00:00:00

  • Optimization of MAGIC gel formulation for three-dimensional radiation therapy dosimetry.

    abstract::Polymer gel dosimetry aims to provide three-dimensional images of radiation therapy dose distributions in irradiated aqueous gels. The first gels required manufacture in an oxygen-free environment, but later the MAGIC formulation was introduced, which could be made in normal atmospheric conditions. Here we report our ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/10/N03

    authors: Luci JJ,Whitney HM,Gore JC

    更新日期:2007-05-21 00:00:00

  • Quality assurance in brachytherapy: the displacement effect in the vicinity of 60Co and 192Ir brachytherapy sources.

    abstract::Cylindrical ionization chambers with varying radii have been used to determine the displacement effect at distances between 10 mm and 40 mm from 60Co and 192Ir brachytherapy sources. Agreement with published values of the displacement factor for external 60Co beams is obtained. The shift between the centre of the ioni...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/38/10/009

    authors: Tölli H,Johansson KA

    更新日期:1993-10-01 00:00:00

  • A comparison of rotation- and blob-based system models for 3D SPECT with depth-dependent detector response.

    abstract::We compare two different implementations of a 3D SPECT system model for iterative reconstruction, both of which compensate for non-uniform photon attenuation and depth-dependent system response. One implementation performs fast rotation of images represented using a basis of rectangular voxels, whereas the other repre...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/11/003

    authors: Yendiki A,Fessler JA

    更新日期:2004-06-07 00:00:00

  • Automated cell cycle analysis with fluorescence microscopy and image analysis.

    abstract::Automatic cell cycle analysis (DNA histograms) is usually performed with flow cytometry. In cases when only few cells are available, the DNA content has to be measured with a fluorescence microscope combined with sensitive camera systems (SIT, MCP, cooled CCDs) and a frame grabber for image analysis. The fluorescent c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/3/013

    authors: Böcker W,Gantenberg HW,Müller WU,Streffer C

    更新日期:1996-03-01 00:00:00

  • Imaging of prompt gamma rays emitted during delivery of clinical proton beams with a Compton camera: feasibility studies for range verification.

    abstract::The purpose of this paper is to evaluate the ability of a prototype Compton camera (CC) to measure prompt gamma rays (PG) emitted during delivery of clinical proton pencil beams for prompt gamma imaging (PGI) as a means of providing in vivo verification of the delivered proton radiotherapy beams. A water phantom was i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/18/7085

    authors: Polf JC,Avery S,Mackin DS,Beddar S

    更新日期:2015-09-21 00:00:00

  • W values and other transport data on low energy electrons in tissue equivalent gas.

    abstract::The degradation of low energy electrons in a methane based, tissue equivalent gas was studied experimentally by ionization chamber experiments and theoretically by Monte Carlo electron transport simulation in the energy range between 25 eV and 5 keV. From measured ionization yields and calculated ionization and energy...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/5/008

    authors: Waibel E,Grosswendt B

    更新日期:1992-05-01 00:00:00

  • Optimisation of the imaging and dosimetric characteristics of an electronic portal imaging device employing plastic scintillating fibres using Monte Carlo simulations.

    abstract::A Monte Carlo model of a novel electronic portal imaging device (EPID) has been developed using Geant4 and its performance for imaging and dosimetry applications in radiotherapy has been characterised. The EPID geometry is based on a physical prototype under ongoing investigation and comprises an array of plastic scin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/22/6827

    authors: Blake SJ,McNamara AL,Vial P,Holloway L,Kuncic Z

    更新日期:2014-11-21 00:00:00

  • Analyses of multi-irradiation film for system alignments in stereotactic radiotherapy (SRT) and radiosurgery (SRS).

    abstract::In stereotactic radiosurgery, a seven-irradiation film was used to define any discrepancy between the beam and target centres. A mathematical model based on the linac alignment and target set-up was developed to diagnose the discrepancies of the seven-irradiation film between the beam and simulation target centres. Fr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/9/003

    authors: Tsai JS

    更新日期:1996-09-01 00:00:00

  • Laser speckle imaging of blood flow in microcirculation.

    abstract::Monitoring the spatio-temporal characteristics of microcirculation is crucial for studying the functional activities of biotissue and the mechanism of disease. However, conventional methods used to measure blood flow suffer from limited spatial resolution or the injection of exogenous substances or the need of scannin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/7/020

    authors: Cheng H,Luo Q,Liu Q,Lu Q,Gong H,Zeng S

    更新日期:2004-04-07 00:00:00

  • Towards a gold standard for quantitative coronary arteriography.

    abstract::Densitometric quantification of coronary artery stenoses in angiographic images can be problematic for two reasons: (i) the x-rays are inadequately oriented with respect to the vessel segments of interest at image acquisition; (ii) non-linear effects due for instance to beam hardening, scattered radiation and veiling ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/12/011

    authors: Doriot PA,Dorsaz PA,Dorsaz L,Bodenmann JJ

    更新日期:1997-12-01 00:00:00

  • Array detection for speckle reduction in optical coherence microscopy.

    abstract::This paper introduces a spatial-diversity method for speckle suppression in optical coherence microscopy. The method is based on combining interference signals from an array of detectors placed in the back focal plane of the objective lens, such that elements receive light backscattered from the sample volume at diffe...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/7/015

    authors: Schmitt JM

    更新日期:1997-07-01 00:00:00

  • Understanding radionuclide production in gas target systems: the effect of adsorption on the target body.

    abstract::Gas target systems have been used for decades on cyclotrons to produce radionuclides for medical imaging. However, the activity recovered from such targets is often lower than its theoretically predicted value. Past research has suggested that nuclide interactions with the walls of the target body may play a key role ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aadf7b

    authors: Zacchia NA,Buckley KR,Martinez GM,Ruth TJ,Martinez DM,Hoehr C

    更新日期:2018-09-28 00:00:00

  • A Fourier rebinning algorithm incorporating spectral transfer efficiency for 3D PET.

    abstract::This paper presents a Fourier rebinning algorithm for three-dimensional image reconstruction in PET that incorporates the concept of spectral transfer function. It suggests the need for discarding low-frequency components in the rebinning. It also includes the correction for rebinning efficiency which was evaluated by...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/4/004

    authors: Tanaka E,Amo Y

    更新日期:1998-04-01 00:00:00

  • An expression for backscatter factors for orthovoltage x-rays.

    abstract::Backscatter factors for orthovoltage x-ray beams are fitted with the expression BSF = 1 + ms/(s + n), where s is field size and m and n are adjustable parameters. The accuracy is better than 0.5%. Good results were also obtained for Cs-137 gamma rays at depth 0.12 cm and Co-60 gamma rays at depth 0.5 cm using the same...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/5/021

    authors: Xiao Y,Bjärngard B

    更新日期:1998-05-01 00:00:00

  • The ArcCHECK diode array for dosimetric verification of HybridArc.

    abstract::The aim of this work is to evaluate dosimetric accuracy of a new treatment modality, HybridArc, in iPlan RT Dose 4.5 (BrainLAB, Feldkirchen, Germany) using a four-dimensional diode array (ArcCHECK, Sun Nuclear Corporation, Melbourne, USA). HybridArc is able to enhance dynamic conformal arcs with inversely planned elem...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/16/021

    authors: Petoukhova AL,van Egmond J,Eenink MG,Wiggenraad RG,van Santvoort JP

    更新日期:2011-08-21 00:00:00

  • Analytical linear energy transfer model including secondary particles: calculations along the central axis of the proton pencil beam.

    abstract::In proton therapy, the relative biological effectiveness (RBE) depends on various types of parameters such as linear energy transfer (LET). An analytical model for LET calculation exists (Wilkens' model), but secondary particles are not included in this model. In the present study, we propose a correction factor, L se...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/2/740

    authors: Marsolat F,De Marzi L,Pouzoulet F,Mazal A

    更新日期:2016-01-21 00:00:00

  • Modifying proton fluence spectra to generate spread-out Bragg peaks with laser accelerated proton beams.

    abstract::Currently, energy spectra of laser accelerated proton beams are far from being monoenergetic. For their application in radiation therapy, energy selection systems using magnetic fields have been proposed to single out particles with the desired energy. These systems allow the choice of protons between a lowest and a h...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/19/N04

    authors: Schell S,Wilkens JJ

    更新日期:2009-10-07 00:00:00

  • Towards abdominal MRI-based treatment planning using population-based Hounsfield units for bulk density assignment.

    abstract::This study investigates the dosimetric impact of using population-based Hounsfield units (HUs) and ICRU-based HUs as a function of the number of tissue segments for bulk density assignment toward MRI-based treatment planning in the abdomen. To avoid potential geometric differences between CT and MR images, CT images r...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aacfb1

    authors: Hsu SH,Zawisza I,O'Grady K,Peng Q,Tomé WA

    更新日期:2018-07-24 00:00:00

  • The energy response of a T.P.A. Mk-II ionization chamber using GEANT4 Monte Carlo simulation.

    abstract::The low energy model of the GEANT4 Monte Carlo toolkit was used to simulate the energy response of a T.P.A. Mk-II ionization chamber under a variety of different conditions. The sample position resulting in the maximum response along the axial direction of the chamber was obtained. The parameters of the simulation wer...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/13/012

    authors: Seneviratne MD,Reinhard MI,Baldock C

    更新日期:2007-07-07 00:00:00

  • Robustness of target dose coverage to motion uncertainties for scanned carbon ion beam tracking therapy of moving tumors.

    abstract::Beam tracking with scanned carbon ion radiotherapy achieves highly conformal target dose by steering carbon pencil beams to follow moving tumors using real-time magnetic deflection and range modulation. The purpose of this study was to evaluate the robustness of target dose coverage from beam tracking in light of posi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/4/1717

    authors: Eley JG,Newhauser WD,Richter D,Lüchtenborg R,Saito N,Bert C

    更新日期:2015-02-21 00:00:00

  • A potential method for in vivo range verification in proton therapy treatment.

    abstract::Proton therapy potentially offers excellent dose conformality and reduction in integral dose. The superior dose distribution is, however, much more sensitive to the radiological depth along the beam path than for photon fields. Variations in this depth due to inaccurate planning calculation, setup uncertainty, respira...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/5/016

    authors: Lu HM

    更新日期:2008-03-07 00:00:00

  • An investigation of factors affecting the accuracy of in vivo measurements of skin pigments by reflectance spectrophotometry.

    abstract::Factors affecting the accuracy of the in vivo measurement of cutaneous pigments and blood oxygenation by reflectance spectrophotometry have been examined. It was found that stray light, the amounts of haemoglobin and melanin, and the level of blood oxygenation all contributed to the measured reflectance and had to be ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/35/9/009

    authors: Hajizadeh-Saffar M,Feather JW,Dawson JB

    更新日期:1990-09-01 00:00:00

  • A validated Geant4 model of a whole-body PET scanner with four-layer DOI detectors.

    abstract::The purpose of this work is to develop a validated Geant4 simulation model of a whole-body prototype PET scanner constructed from the four-layer depth-of-interaction detectors developed at the National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Japan. T...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abaa24

    authors: Ahmed AM,Chacon A,Rutherford H,Akamatsu G,Mohammadi A,Nishikido F,Tashima H,Yoshida E,Yamaya T,Franklin DR,Rosenfeld A,Guatelli S,Safavi-Naeini M

    更新日期:2020-12-18 00:00:00

  • Modelling the temporal region in patients with temporal lobe epilepsy.

    abstract::EEG interictal epileptiform discharges in temporal lobe epilepsy are associated with magnetic fields. The maxima of magnetic spikes recorded over the spherical portions of the head appear fairly symmetric, whereas those over the lower temporal region often have irregular shapes. Furthermore, their magnitude is often u...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/1/009

    authors: Rose DF,Sato S,Smith PD,White J

    更新日期:1987-01-01 00:00:00

  • Investigation of ultrasonic properties of PAG and MAGIC polymer gel dosimeters.

    abstract::Ultrasonic speed of propagation and attenuation were investigated as a function of absorbed radiation dose in PAG and MAGIC polymer gel dosimeters. Both PAG and MAGIC gel dosimeters displayed a dependence of ultrasonic parameters on absorbed dose with attenuation displaying significant changes in the dose range invest...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/24/307

    authors: Mather ML,De Deene Y,Whittaker AK,Simon GP,Rutgers R,Baldock C

    更新日期:2002-12-21 00:00:00

  • Perturbation correction for alanine dosimeters in different phantom materials in high-energy photon beams.

    abstract::In modern radiotherapy the verification of complex treatments plans is often performed in inhomogeneous or even anthropomorphic phantoms. For dose verification small detectors are necessary and therefore alanine detectors are most suitable. Though the response of alanine for a wide range of clinical photon energies in...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/3/N70

    authors: von Voigts-Rhetz P,Anton M,Vorwerk H,Zink K

    更新日期:2016-02-07 00:00:00

  • Prior image constrained scatter correction in cone-beam computed tomography image-guided radiation therapy.

    abstract::X-ray scatter is a significant problem in cone-beam computed tomography when thicker objects and larger cone angles are used, as scattered radiation can lead to reduced contrast and CT number inaccuracy. Advances have been made in x-ray computed tomography (CT) by incorporating a high quality prior image into the imag...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/4/009

    authors: Brunner S,Nett BE,Tolakanahalli R,Chen GH

    更新日期:2011-02-21 00:00:00