Intensity of the flash associated with laser-induced plasma in the eye.

Abstract:

:A bright flash of light is emitted by the plasma formed at the focus of an ophthalmic Nd: YAG laser. The purpose of this investigation is to determine whether the plasma flash constitutes a hazard to the operator. The intensity of the flash at the slit lamp eyepiece was measured and the experimentally derived value was verified by independent calculation. For hazard assessment purposes, the concept of a spectrally weighted maximum permissible exposure (MPE) is described in the paper. Based on the MPE and our measurements and calculations our conclusion is that viewing the flash in a patient's eye through the microscope would not be considered hazardous to the operator. In contrast, during technical procedures, targets in air are used to produce a plasma and in this situation eye protection is recommended when viewing the flash through the microscope.

journal_name

Phys Med Biol

authors

Moseley H,Allan D

doi

10.1088/0031-9155/32/9/009

subject

Has Abstract

pub_date

1987-09-01 00:00:00

pages

1159-66

issue

9

eissn

0031-9155

issn

1361-6560

journal_volume

32

pub_type

杂志文章
  • Dosimetric verification in participating institutions in a stereotactic body radiotherapy trial for stage I non-small cell lung cancer: Japan clinical oncology group trial (JCOG0403).

    abstract::A multicentre phase II trial of stereotactic body radiotherapy for T1N0M0 non-small cell lung cancer was initiated in Japan as the Japan Clinical Oncology Group trial (JCOG0403). Before starting the trial, a decision was made to evaluate the treatment machine and treatment planning in participating institutions to min...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,多中心研究

    doi:10.1088/0031-9155/51/21/002

    authors: Nishio T,Kunieda E,Shirato H,Ishikura S,Onishi H,Tateoka K,Hiraoka M,Narita Y,Ikeda M,Goka T

    更新日期:2006-11-07 00:00:00

  • Reply to comment on 'origins of the changing detector response in small megavoltage photon radiation fields'.

    abstract::Andreo and Benmakhlouf (2017 Phys. Med. Biol. 62 1518-32) have disputed a finding of Scott et al (2012 Phys. Med. Biol. 57 4461-76) that the variation with field-size of the response of small ion chambers and solid-state dosimeters in small megavoltage photon radiation fields can largely be attributed to density. Furt...

    journal_title:Physics in medicine and biology

    pub_type: 评论,杂志文章

    doi:10.1088/1361-6560/aae0e4

    authors: Fenwick JD,Georgiou G,Rowbottom CG,Underwood TSA,Kumar S

    更新日期:2018-10-03 00:00:00

  • Carbon ion therapy for ocular melanoma: planning orthogonal two-port treatment.

    abstract::We recently started orthogonal two-port carbon ion therapy for choroidal melanoma with the intent to reduce the incidence of radiation complications that occur with mono-port therapy. Treatment planning techniques involving therapeutic beam characteristics are described here. The vertical (140 MeV/u) and horizontal (1...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/17/016

    authors: Koyama-Ito H,Kanai T,Minohara S,Tsuji H,Tsujii H

    更新日期:2007-09-07 00:00:00

  • Measurement of calcium in sections of a human skeleton using a reactor spectrum-in vivo activation analysis technique.

    abstract::Factors influencing the precision of measuring changes in the calcium content of sections of bone, including vertebrae, using reactor neutrons for partial body in vivo activation analysis have been examined and quantified. These factors include (a) the choice of incidient neutron spectrum, (b) the uniformity of activa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/20/1/007

    authors: Boddy K,Glaros D,Robertson I

    更新日期:1975-01-01 00:00:00

  • An investigation of factors affecting the accuracy of in vivo measurements of skin pigments by reflectance spectrophotometry.

    abstract::Factors affecting the accuracy of the in vivo measurement of cutaneous pigments and blood oxygenation by reflectance spectrophotometry have been examined. It was found that stray light, the amounts of haemoglobin and melanin, and the level of blood oxygenation all contributed to the measured reflectance and had to be ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/35/9/009

    authors: Hajizadeh-Saffar M,Feather JW,Dawson JB

    更新日期:1990-09-01 00:00:00

  • A basic dosimetric study of PRESAGE: the effect of different amounts of fabricating components on the sensitivity and stability of the dosimeter.

    abstract::Over the past few years there has been much interest in the development of three-dimensional dosimeters to determine the complex absorbed dose distribution in modern radiotherapy techniques such as IMRT and IGRT. In routine methods used for three-dimensional dosimetry, polymer gels are commonly used. Recently, a novel...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/3/023

    authors: Mostaar A,Hashemi B,Zahmatkesh MH,Aghamiri SM,Mahdavi SR

    更新日期:2010-02-07 00:00:00

  • Gating characteristics of an Elekta radiotherapy treatment unit measured with three types of detector.

    abstract::The characteristics of an Elekta Precise treatment machine with a gating interface were investigated. Three detectors were used: a Farmer ionization chamber, a MatriXX ionization chamber array and an in-house, single pulse-measurement ionization chamber (IVC). Measurements were made of dosimetric accuracy, flatness an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/8/N02

    authors: Evans PM,Symonds-Tayler JR,Colgan R,Hugo GD,Letts N,Sandin C

    更新日期:2010-04-21 00:00:00

  • Role of skin tissue layers and ultra-structure in transcutaneous electrical stimulation including tDCS.

    abstract:BACKGROUND:During transcranial electrical stimulation (tES), including transcranial direct current stimulation (tDCS) and transcranial alternating current stimulation (tACS), current density concentration around the electrode edges that is predicted by simplistic skin models does not match experimental observations of ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abb7c1

    authors: Khadka N,Bikson M

    更新日期:2020-09-11 00:00:00

  • Quantification of lung tumor rotation with automated landmark extraction using orthogonal cine MRI images.

    abstract::The quantification of tumor motion in sites affected by respiratory motion is of primary importance to improve treatment accuracy. To account for motion, different studies analyzed the translational component only, without focusing on the rotational component, which was quantified in a few studies on the prostate with...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/18/7165

    authors: Paganelli C,Lee D,Greer PB,Baroni G,Riboldi M,Keall P

    更新日期:2015-09-21 00:00:00

  • Electron depth-dose dependence on energy spectral quality.

    abstract::Electron depth-dose curves and spectra have been measured from an experimental accelerator on which both energy and spectral shape could be varied independently. The measurements were made at nominal energies of 6 and 12 MeV, with the energy spread (FWHM) varied from 1.7% to over 10% of average energy. Changes in dept...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/28/12/005

    authors: Johnsen SW,LaRiviere PD,Tanabe E

    更新日期:1983-12-01 00:00:00

  • A new approach to account for the medium-dependent effect in model-based dose calculations for kilovoltage x-rays.

    abstract::This study presents a new approach to accurately account for the medium-dependent effect in model-based dose calculations for kilovoltage (kV) x-rays. This approach is based on the hypothesis that the correction factors needed to convert dose from model-based dose calculations to absorbed dose-to-medium depend on both...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/13/011

    authors: Pawlowski JM,Ding GX

    更新日期:2011-07-07 00:00:00

  • Generalized method for computation of true thickness and x-ray intensity information in highly blurred sub-millimeter bone features in clinical CT images.

    abstract::In clinical computed tomography (CT) images, cortical bone features with sub-millimeter (sub-mm) thickness are substantially blurred, such that their thickness is overestimated and their intensity appears underestimated. Therefore, any inquiry of the geometry or the density of such bones based on these images is sever...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/23/8099

    authors: Pakdel A,Robert N,Fialkov J,Maloul A,Whyne C

    更新日期:2012-12-07 00:00:00

  • New compensator design options for charged-particle radiotherapy.

    abstract::The purpose of this investigation is to propose new compensator design strategies for protons and heavier particles which are based on pencil-beam (PB) dose calculations and which significantly reduce the dose to tissues downstream from the target, yet provide acceptable target coverage under conditions of patient mot...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/7/005

    authors: Petti PL

    更新日期:1997-07-01 00:00:00

  • Clinical evaluation of 4D PET motion compensation strategies for treatment verification in ion beam therapy.

    abstract::A clinical trial named PROMETHEUS is currently ongoing for inoperable hepatocellular carcinoma (HCC) at the Heidelberg Ion Beam Therapy Center (HIT, Germany). In this framework, 4D PET-CT datasets are acquired shortly after the therapeutic treatment to compare the irradiation induced PET image with a Monte Carlo PET p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/11/4141

    authors: Gianoli C,Kurz C,Riboldi M,Bauer J,Fontana G,Baroni G,Debus J,Parodi K

    更新日期:2016-06-07 00:00:00

  • Dosimetric and workflow evaluation of first commercial synthetic CT software for clinical use in pelvis.

    abstract::To evaluate a commercial synthetic CT (syn-CT) software for use in prostate radiotherapy. Twenty-five prostate patients underwent CT and MR simulation scans in treatment position on a 3T MR scanner. A commercially available MR protocol was used that included a T2w turbo spin-echo sequence for soft-tissue contrast and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5452

    authors: Tyagi N,Fontenla S,Zhang J,Cloutier M,Kadbi M,Mechalakos J,Zelefsky M,Deasy J,Hunt M

    更新日期:2017-04-21 00:00:00

  • Symmetries of the 2D magnetic particle imaging system matrix.

    abstract::In magnetic particle imaging (MPI), the relation between the particle distribution and the measurement signal can be described by a linear system of equations. For 1D imaging, it can be shown that the system matrix can be expressed as a product of a convolution matrix and a Chebyshev transformation matrix. For multidi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/10/4033

    authors: Weber A,Knopp T

    更新日期:2015-05-21 00:00:00

  • Collapsed cone convolution and analytical anisotropic algorithm dose calculations compared to VMC++ Monte Carlo simulations in clinical cases.

    abstract::The purpose of this work was to study and quantify the differences in dose distributions computed with some of the newest dose calculation algorithms available in commercial planning systems. The study was done for clinical cases originally calculated with pencil beam convolution (PBC) where large density inhomogeneit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/13/002

    authors: Hasenbalg F,Neuenschwander H,Mini R,Born EJ

    更新日期:2007-07-07 00:00:00

  • A water calorimeter for neutron dosimetry.

    abstract::A water calorimeter has been used for the direct measurement of absorbed dose to water in a d(15) + Be neutron beam. The absorbed dose measured with the calorimeter was compared with that measured with an Exradin ionisation chamber, constructed of A-150 plastic. The doses measured by the ionisation chamber were calcul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/4/005

    authors: Galloway G,Greening JR,Williams JR

    更新日期:1986-04-01 00:00:00

  • Improved scatter correction using adaptive scatter kernel superposition.

    abstract::Accurate scatter correction is required to produce high-quality reconstructions of x-ray cone-beam computed tomography (CBCT) scans. This paper describes new scatter kernel superposition (SKS) algorithms for deconvolving scatter from projection data. The algorithms are designed to improve upon the conventional approac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/22/007

    authors: Sun M,Star-Lack JM

    更新日期:2010-11-21 00:00:00

  • Monte Carlo simulations of a nozzle for the treatment of ocular tumours with high-energy proton beams.

    abstract::By the end of 2002, 33 398 patients worldwide had been treated with proton radiotherapy, 10 829 for eye diseases. The dose prediction algorithms used today for ocular proton therapy treatment planning rely on parameterizations of measured proton dose distributions, i.e., broad-beam and pencil-beam techniques, whose pr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/22/002

    authors: Newhauser W,Koch N,Hummel S,Ziegler M,Titt U

    更新日期:2005-11-21 00:00:00

  • The production of positron emitters with millisecond half-life during helium beam radiotherapy.

    abstract::Therapy with helium ions is currently receiving significantly increasing interest because helium ions have a sharper penumbra than protons and undergo less fragmentation than carbon ions and thus require less complicated dose calculations. For any ion of interest in hadron therapy, the accuracy of dose delivery is lim...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab51c3

    authors: Ozoemelam I,van der Graaf E,Brandenburg S,Dendooven P

    更新日期:2019-12-05 00:00:00

  • A novel description of FDG excretion in the renal system: application to metformin-treated models.

    abstract::This paper introduces a novel compartmental model describing the excretion of 18F-fluoro-deoxyglucose (FDG) in the renal system and a numerical method based on the maximum likelihood for its reduction. This approach accounts for variations in FDG concentration due to water re-absorption in renal tubules and the increa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/10/2469

    authors: Garbarino S,Caviglia G,Sambuceti G,Benvenuto F,Piana M

    更新日期:2014-05-21 00:00:00

  • Radiation binary targeted therapy for HER-2 positive breast cancers: assumptions, theoretical assessment and future directions.

    abstract::A novel radiation targeted therapy is investigated for HER-2 positive breast cancers. The proposed concept combines two known approaches, but never used together for the treatment of advanced, relapsed or metastasized HER-2 positive breast cancers. The proposed radiation binary targeted concept is based on the anti HE...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/6/001

    authors: Mundy DW,Harb W,Jevremovic T

    更新日期:2006-03-21 00:00:00

  • Experimental 3D dosimetry around a high-dose-rate clinical 192Ir source using a polyacrylamide gel (PAG) dosimeter.

    abstract::It is well known that the experimental dosimetry of brachytherapy sources presents a challenge. Depending on the particular-dosimeter used, measurements can suffer from poor spatial resolution (ion chambers), lack of 3D information (film) or errors due to the presence of the dosimeter itself distorting the radiation f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/10/305

    authors: McJury M,Tapper PD,Cosgrove VP,Murphy PS,Griffin S,Leach MO,Webb S,Oldham M

    更新日期:1999-10-01 00:00:00

  • SAR calculations in an anatomically realistic model of the head for mobile communication transceivers at 900 MHz and 1.8 GHz.

    abstract::A new mathematical model of the head has been constructed from a set of serial MRI slices from one subject. Finite-difference time-domain (FDTD) calculations of the specific energy absorption rate (SAR) have been performed on this model with a 2 mm resolution for a generic mobile communication transceiver represented ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/10/003

    authors: Dimbylow PJ,Mann SM

    更新日期:1994-10-01 00:00:00

  • Report of the IPSM working party on low- and medium-energy x-ray dosimetry. Institute of Physical Sciences in Medicine.

    abstract::New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the IAEA in 1987. These are not considered to possess sufficient support from other s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/8/001

    authors:

    更新日期:1991-08-01 00:00:00

  • Geometrical and dosimetrical characterization of the photon source using a micro-multileaf collimator for stereotactic radiosurgery.

    abstract::A micro-multileaf collimator (microMLC) for stereotactic radiosurgery is used for determination of the spatial intensity distribution of the photon source of a linear accelerator. The method is based on grid field dose measurements using film dosimetry and is easy to perform. Since the microMLC does not allow 'direct'...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/15/305

    authors: Treuer H,Hoevels M,Luyken K,Hunsche S,Kocher M,Müller RP,Sturm V

    更新日期:2003-08-07 00:00:00

  • The physics of red cell sedimentation.

    abstract::Blood was withdrawn from the ante-cubital vein of five normal volunteers and the erythrocytes were washed and resuspended in isotonic saline. The rate of descent of the erythrocyte-saline boundary was measured every hour for a period of at least 4 h for different suspended cell concentrations. The velocity of this bou...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/2/002

    authors: Smallwood RH,Tindale WB,Trowbridge EA

    更新日期:1985-02-01 00:00:00

  • Stopping cross-sections of various gases for alpha particles in the energy region 0.2 to 5.5 MeV.

    abstract::A single experimental apparatus has been designed to allow measurements of stopping cross-sections of materials in liquid and vapour phase, for alpha particles, using an indirect method. The method, in which residual energies for increasing absorber thicknesses are obtained and differentiated, has been used in a numbe...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/5/004

    authors: Thwaites DI

    更新日期:1980-09-01 00:00:00

  • Development of a fast Monte Carlo dose calculation system for online adaptive radiation therapy quality assurance.

    abstract::Online adaptive radiation therapy (ART) based on real-time magnetic resonance imaging represents a paradigm-changing treatment scheme. However, conventional quality assurance (QA) methods based on phantom measurements are not feasible with the patient on the treatment couch. The purpose of this work is to develop a fa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6e38

    authors: Wang Y,Mazur TR,Park JC,Yang D,Mutic S,Li HH

    更新日期:2017-06-21 00:00:00