Experimental characterization of two-dimensional pencil beam scanning proton spot profiles.

Abstract:

:Dose calculations of pencil beam scanning treatment plans rely on the accuracy of proton spot profiles; not only the primary component but also the broad tail components. Four films are placed at several locations in air and multiple depths in Solidwater® for six selected energies. The films used for the primary components are exposed to 50-200 MU to avoid saturation; the films used for the tail components are exposed to 800, 8000 and 80,000 MU. By applying a pair/magnification method and merging these data, dose kernels down to 10(-4) of the central spot dose can be generated. From these kernels one can calculate the dose-per-MU for different field sizes and shapes. Measurements agree within 1% of dose-kernel-based calculations for output versus field size comparisons. Asymmetric, comet-shaped profile tails have a bigger impact at superficial depths and low energies: the output difference between two orientations at the surface of a rectangular field of 40 mm×200 mm is about 2% at the isocentre at 100 MeV. Integration of these dose kernels from 0 to 40 mm radius shows that the charge deficit in the Bragg peak chamber varies <2% from entrance to the end of range for energies <180 MeV, but exceeds 5% at 225 MeV.

journal_name

Phys Med Biol

authors

Lin L,Ainsley CG,McDonough JE

doi

10.1088/0031-9155/58/17/6193

subject

Has Abstract

pub_date

2013-09-07 00:00:00

pages

6193-204

issue

17

eissn

0031-9155

issn

1361-6560

journal_volume

58

pub_type

杂志文章
  • Transport calculations of depth-dose distributions for gadolinium neutron capture therapy.

    abstract::Depth-dose distributions were calculated for thermal and epithermal neutron fluence and capture gamma ray dose rates using a two-dimensional neutron-coupled gamma-ray transport code (DOT 3.5) for gadolinium neutron capture therapy. The results show that (i) a capture gamma-ray dose rate of 10 Gy h-1 was obtained with ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/1/010

    authors: Matsumoto T

    更新日期:1992-01-01 00:00:00

  • A determination by an analysis of X-ray attenuation in aluminium of the intesity distribution at its point of origin in a thick tungsten target of bremsstrahlung excited by constant potentials of 60-140 kV.

    abstract::A recently described, computer aided method of attenuation analysis has been applied to free-air chamber measurements of the attenuation by up to 30mm A1 of the exposure rate of a narrow beam of X-radiation excited at a thick W target in a Be window tube by constant potentials of 60, 80, 100, 120 and 140 kV. It has ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/22/2/001

    authors: Soole BW

    更新日期:1977-03-01 00:00:00

  • Application of the adaptive wavelet transform for analysis of blood flow oscillations in the human skin.

    abstract::An original method for the analysis of oscillations of cutaneous blood flow has been developed, which makes use of laser Doppler flowmetry (LDF) data and is based on the continuous wavelet transform and adaptive wavelet theory. The potential of the method has been demonstrated in experiments with the response of micro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/21/005

    authors: Tankanag A,Chemeris N

    更新日期:2008-11-07 00:00:00

  • A beam profile generation algorithm for wedged half-beam blocked asymmetric fields.

    abstract::A method is presented to predict beam profiles and outputs for wedged asymmetric fields defined by independent collimator jaws allowing fast generation of beam profiles whilst requiring very little additional data to that already used by most treatment planning systems in generating symmetric field isodoses. Symmetric...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/1/004

    authors: Millin AE,Smith CW

    更新日期:1994-01-01 00:00:00

  • Substituting gelatine with Pluronic F-127 matrix in 3D polymer gel dosimeters can improve nuclear magnetic resonance, thermal and optical properties.

    abstract::This work discusses the substitution of a gelatine physical gel matrix with a matrix made of poly(ethylene oxide)-block-poly(propylene oxide)-block-poly(ethylene oxide) (Pluronic F-127) in five 3D radiotherapy polymer gel dosimeters: MAGAT, PAGAT, NIPAM, VIPARnd (VIP) and VIPARCT (VIC). The current research outcomes s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad9d5

    authors: Jaszczak M,Wach R,Maras P,Dudek M,Kozicki M

    更新日期:2018-09-06 00:00:00

  • Evaluation of a novel triple-channel radiochromic film analysis procedure using EBT2.

    abstract::A novel approach to read out radiochromic film was introduced recently by the manufacturer of GafChromic film. In this study, the performance of this triple-channel film dosimetry method was compared against the conventional single-red-channel film dosimetry procedure, with and without inclusion of a pre-irradiation (...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/13/4353

    authors: van Hoof SJ,Granton PV,Landry G,Podesta M,Verhaegen F

    更新日期:2012-07-07 00:00:00

  • Investigation of the sag in linac secondary collimator and MLC carriage during arc deliveries.

    abstract::In modern radiotherapy, it is vitally important to monitor the performance of all linac components including the collimation system. In this study, a simple measurement method and accurate algorithm are introduced for investigation of the secondary and tertiary collimator sag during radiotherapy arc treatments. The me...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/12/N209

    authors: Rowshanfarzad P,Sabet M,O'Connor DJ,Greer PB

    更新日期:2012-06-21 00:00:00

  • Experimental verification of numerical simulations of cryosurgery with application to computerized planning.

    abstract::As a part of an ongoing effort to develop computerized planning tools for cryosurgery, an experimental study has been conducted to verify a recently developed numerical technique for bioheat transfer simulations. Experiments were performed on gelatin solution as a phantom material, using proprietary liquid-nitrogen cr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/15/013

    authors: Rossi MR,Rabin Y

    更新日期:2007-08-07 00:00:00

  • Image-based point spread function implementation in a fully 3D OSEM reconstruction algorithm for PET.

    abstract::The interest in positron emission tomography (PET) and particularly in hybrid integrated PET/CT systems has significantly increased in the last few years due to the improved quality of the obtained images. Nevertheless, one of the most important limits of the PET imaging technique is still its poor spatial resolution ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/14/012

    authors: Rapisarda E,Bettinardi V,Thielemans K,Gilardi MC

    更新日期:2010-07-21 00:00:00

  • A promising new mechanism of ionizing radiation detection for positron emission tomography: modulation of optical properties.

    abstract::Using conventional scintillation detection, the fundamental limit in positron emission tomography (PET) time resolution is strongly dependent on the inherent temporal variances generated during the scintillation process, yielding an intrinsic physical limit for the coincidence time resolution of around 100 ps. On the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/21/7600

    authors: Tao L,Daghighian HM,Levin CS

    更新日期:2016-11-07 00:00:00

  • Full-field speckle interferometry for non-contact photoacoustic tomography.

    abstract::A full-field speckle interferometry method for non-contact and prospectively high speed Photoacoustic Tomography is introduced and evaluated as proof of concept. Thermoelastic pressure induced changes of the objects topography are acquired in a repetitive mode without any physical contact to the object. In order to ob...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/10/4045

    authors: Horstmann J,Spahr H,Buj C,Münter M,Brinkmann R

    更新日期:2015-05-21 00:00:00

  • Beveled fiber-optic probe couples a ball lens for improving depth-resolved fluorescence measurements of layered tissue: Monte Carlo simulations.

    abstract::In this study, we evaluate the feasibility of designing a beveled fiber-optic probe coupled with a ball lens for improving depth-resolved fluorescence measurements of epithelial tissue using Monte Carlo (MC) simulations. The results show that by using the probe configuration with a beveled tip collection fiber and a f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/4/008

    authors: Jaillon F,Zheng W,Huang Z

    更新日期:2008-02-21 00:00:00

  • Development and comparison of computer methods for organ motion correction in scintigraphy.

    abstract::The process of organ motion correction in scintigraphy is analysed in the frequency domain. The sequence of the chi- and gamma- coordinates registered during scintigraphic recording is converted to a frequency spectrum by a discrete Fourier transform. In the frequency domain motion correction is performed by linear fi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/20/3/010

    authors: Schmidlin P

    更新日期:1975-05-01 00:00:00

  • Local hydrogen clearance as a method for the measurement of capillary blood flow.

    abstract::A hydrogen clearance technique for the measurement of capillary blood flow in skeletal muscle (both resting and working) and the beating heart in experimental animals is described. Various methods for introducing the hydrogen into the region of measurement are compared, together with the appropriate methods for evalua...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/10/005

    authors: Harrison DK,Kessler M

    更新日期:1989-10-01 00:00:00

  • PET monitoring of cancer therapy with 3He and 12C beams: a study with the GEANT4 toolkit.

    abstract::We study the spatial distributions of beta(+)-activity produced by therapeutic beams of (3)He and (12)C ions in various tissue-like materials. The calculations were performed within a Monte Carlo model for heavy-ion therapy (MCHIT) based on the GEANT4 toolkit. The contributions from positron-emitting nuclei with T(1/2...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/24/007

    authors: Pshenichnov I,Larionov A,Mishustin I,Greiner W

    更新日期:2007-12-21 00:00:00

  • Locally linear constraint based optimization model for material decomposition.

    abstract::Dual spectral computed tomography (DSCT) has a superior material distinguishability than the conventional single spectral computed tomography (SSCT). However, the decomposition process is an illposed problem, which is sensitive to noise. Thus, the decomposed image quality is degraded, and the corresponding signal-to-n...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa8e13

    authors: Wang Q,Zhu Y,Yu H

    更新日期:2017-10-19 00:00:00

  • Brachytherapy technology and physics practice since 1950: a half-century of progress.

    abstract::The 50-year tenure of Physics in Medicine and Biology has coincided with some of the most important developments in radiological science, including the introduction of artificial radioactivity, computers and 3D imaging into medicine. These events have profoundly influenced the development of brachytherapy. Although it...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/51/13/R18

    authors: Williamson JF

    更新日期:2006-07-07 00:00:00

  • Stopping power and ranges of low-energy protons in tissue-equivalent gas.

    abstract::Stopping power data for protons in tissue-equivalent gas (64.4% CH4 + 32.4% CO2 + 3.2% N2, partial pressures) were derived from experimentally determined ranges and from differential ionisation distributions using the differential energy required per ion pair formed to convert ionisation to energy loss. The proton ene...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/3/006

    authors: Waibel E,Willems G

    更新日期:1987-03-01 00:00:00

  • Monitoring daily MLC positional errors using trajectory log files and EPID measurements for IMRT and VMAT deliveries.

    abstract::This work investigated the differences between multileaf collimator (MLC) positioning accuracy determined using either log files or electronic portal imaging devices (EPID) and then assessed the possibility of reducing patient specific quality control (QC) via phantom-less methodologies. In-house software was develope...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/9/N49

    authors: Agnew A,Agnew CE,Grattan MW,Hounsell AR,McGarry CK

    更新日期:2014-05-07 00:00:00

  • Thermal effects of radiation from cellular telephones.

    abstract::A finite element thermal model of the head has been developed to calculate temperature rises generated in the brain by radiation from cellular telephones and similar electromagnetic devices. A 1 mm resolution MRI dataset was segmented semiautomatically, assigning each volume element to one of ten tissue types. A finit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/8/321

    authors: Wainwright P

    更新日期:2000-08-01 00:00:00

  • Theoretical modeling of yields for proton-induced reactions on natural and enriched molybdenum targets.

    abstract::Recent acute shortage of medical radioisotopes prompted investigations into alternative methods of production and the use of a cyclotron and ¹⁰⁰Mo(p,2n)(99m)Tc reaction has been considered. In this context, the production yields of (99m)Tc and various other radioactive and stable isotopes which will be created in the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/17/002

    authors: Celler A,Hou X,Bénard F,Ruth T

    更新日期:2011-09-07 00:00:00

  • A dose calculation method including scatter for IMRT optimization.

    abstract::IMRT optimization is an iterative process in which many dose calculations may be necessary. A fast and accurate dose calculation engine is essential for the optimization program to converge to a reliable solution in a reasonable time. Previously we developed a fast dose calculation method for IMRT optimization based o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/19/011

    authors: Wu Q

    更新日期:2004-10-07 00:00:00

  • A mathematical model for predicting the changes of non-small cell lung cancer based on tumor mass during radiotherapy.

    abstract::This study aims to build a feasible mathematical model to analyze the mass evolution of NSCLC during standard fractionated radiotherapy. Seventy-three cases of NSCLC who were received radiotherapy with prescription dose of 2 Gy  ×  30 fx were selected retrospectively and divided into adenocarcinoma (ADC) group and squ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab47c0

    authors: Chen J,Wang K,Jian J,Zhang W

    更新日期:2019-11-26 00:00:00

  • A novel microbubble construct for intracardiac or intravascular MR manometry: a theoretical study.

    abstract::It has been demonstrated that gas-filled microbubble contrast agents, based on their volume changes, can serve as pressure probes in an MR field. It was recently reported that such an MR-based pressure measurement with microbubbles at 1.5 T must make use of microbubbles that have a volumetric magnetic susceptibility d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/20/001

    authors: Dharmakumar R,Plewes DB,Wright GA

    更新日期:2005-10-21 00:00:00

  • Computer-aided diagnosis of lung cancer: the effect of training data sets on classification accuracy of lung nodules.

    abstract::This study aims to develop a computer-aided diagnosis (CADx) scheme for classification between malignant and benign lung nodules, and also assess whether CADx performance changes in detecting nodules associated with early and advanced stage lung cancer. The study involves 243 biopsy-confirmed pulmonary nodules. Among ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa610

    authors: Gong J,Liu JY,Sun XW,Zheng B,Nie SD

    更新日期:2018-02-05 00:00:00

  • On the dosimetric behaviour of photon dose calculation algorithms in the presence of simple geometric heterogeneities: comparison with Monte Carlo calculations.

    abstract::A comparative study was performed to reveal differences and relative figures of merit of seven different calculation algorithms for photon beams when applied to inhomogeneous media. The following algorithms were investigated: Varian Eclipse: the anisotropic analytical algorithm, and the pencil beam with modified Batho...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/5/011

    authors: Fogliata A,Vanetti E,Albers D,Brink C,Clivio A,Knöös T,Nicolini G,Cozzi L

    更新日期:2007-03-07 00:00:00

  • Analytical description of dose profile behaviour in Gamma Knife radiosurgery.

    abstract::Stereotactic Gamma Knife radiosurgery utilizes ionizing beams from (60)Co sources and relies on a combination of collimator sizes, weighting, etc to generate a high-dose region that is conformal with a designated target volume. Dose computation is typically performed by computer, but in this paper, single collimator d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/8/003

    authors: Fenner J,Gwilliam M,Mehrem R,Bird A,Walton L

    更新日期:2008-04-21 00:00:00

  • UWB pulse propagation into human tissues.

    abstract::In this paper the propagation of a UWB pulse into a layered model of the human body is studied to characterize absorption and reflection of the UWB signal due to the different body tissues. Several time behaviours for the incident UWB pulse are considered and compared with reference to the feasibility of breath and he...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/24/8689

    authors: Cavagnaro M,Pittella E,Pisa S

    更新日期:2013-12-21 00:00:00

  • A technique for respiratory-gated radiotherapy treatment verification with an EPID in cine mode.

    abstract::Respiratory gating based on external surrogates is performed in many clinics. We have developed a new technique for treatment verification using an electronic portal imaging device (EPID) in cine mode for gated 3D conformal therapy. Implanted radiopaque fiducial markers inside or near the target are required for this ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/16/002

    authors: Berbeco RI,Neicu T,Rietzel E,Chen GT,Jiang SB

    更新日期:2005-08-21 00:00:00

  • A validated Geant4 model of a whole-body PET scanner with four-layer DOI detectors.

    abstract::The purpose of this work is to develop a validated Geant4 simulation model of a whole-body prototype PET scanner constructed from the four-layer depth-of-interaction detectors developed at the National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Japan. T...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abaa24

    authors: Ahmed AM,Chacon A,Rutherford H,Akamatsu G,Mohammadi A,Nishikido F,Tashima H,Yoshida E,Yamaya T,Franklin DR,Rosenfeld A,Guatelli S,Safavi-Naeini M

    更新日期:2020-12-18 00:00:00