Abstract:
:A stable cryogel dosimeter was prepared using ferrous benzoic xylenol orange (FBX) in a transparent poly-(vinyl alcohol) (PVA) cryogel matrix. Dose response was evaluated for different numbers of freeze-thaw cycles (FTCs), different concentrations of PVA, and ratios of water/dimethyl sulfoxide. Linear relationships between dose and absorbance were obtained in the range of 0-1000 cGy for all formulations. Increasing the concentration of PVA and number of FTCs resulted in increased absorbance and sensitivity. The effects of energy and dose rate were also evaluated. No significant dose rate dependence was observed over the range 1.05 to 6.33 Gy min(-1). No energy response was observed over photon energies of 6, 10, and 18 MV.
journal_name
Phys Med Bioljournal_title
Physics in medicine and biologyauthors
Eyadeh MM,Farrell TJ,Diamond KRdoi
10.1088/0031-9155/59/7/1773subject
Has Abstractpub_date
2014-04-07 00:00:00pages
1773-87issue
7eissn
0031-9155issn
1361-6560journal_volume
59pub_type
杂志文章abstract::The 50-year tenure of Physics in Medicine and Biology has coincided with some of the most important developments in radiological science, including the introduction of artificial radioactivity, computers and 3D imaging into medicine. These events have profoundly influenced the development of brachytherapy. Although it...
journal_title:Physics in medicine and biology
pub_type: 杂志文章,评审
doi:10.1088/0031-9155/51/13/R18
更新日期:2006-07-07 00:00:00
abstract::Laser interstitial thermotherapy (LITT) is employed to destroy tumors in organs, and its outcome strongly depends on the temperature distribution inside the treated tissue. The recent introduction of computed tomography (CT) scan thermometry, based on the CT number dependence of the tissue with temperature, overcomes ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/16/5705
更新日期:2013-08-21 00:00:00
abstract::Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) is a valuable tool for assessing treatment response to novel cancer therapeutics. With appropriate data acquisition, quantitative functional parameter estimates can be obtained by fitting a model to the data. This research focuses on applying a dual-input ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/7/023
更新日期:2009-04-07 00:00:00
abstract::Fully three-dimensional positron emission tomography is considered and a reconstruction algorithm derived. The reconstruction problem is formulated mathematically as a three-dimensional convolution integral of a point spread function with an unknown positron activity distribution and is solved by Fourier transform met...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/25/1/010
更新日期:1980-01-01 00:00:00
abstract::A new thin-target method (patent pending) is described for portal imaging with low-energy (tens of keV) photons from a medical linear accelerator operating in a special mode. Low-energy photons are usually produced in the accelerator target, but are absorbed by the target and flattening filter, both made of medium- or...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/43/8/016
更新日期:1998-08-01 00:00:00
abstract::Absorption and emission optical projection tomography (OPT), alternatively referred to as optical computed tomography (optical-CT) and optical-emission computed tomography (optical-ECT), are recently developed three-dimensional imaging techniques with value for developmental biology and ex vivo gene expression studies...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/18/009
更新日期:2010-09-21 00:00:00
abstract::The purpose of this work is to develop and test a method to estimate the relative and absolute absorbed radiation dose from axial and spiral CT scans using a Monte Carlo approach. Initial testing was done in phantoms and preliminary results were obtained from a standard mathematical anthropomorphic model (MIRD V) and ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/48/16/306
更新日期:2003-08-21 00:00:00
abstract::The problem of fluorescence diffuse optical tomography consists in localizing fluorescent markers from near-infrared light measurements. Among the different available acquisition modalities, the time-resolved modality is expected to provide measurements of richer information content. To extract this information, the m...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/23/004
更新日期:2009-12-07 00:00:00
abstract::Lung tumors treated in breath-hold are subject to inter- and intra-breath-hold variations, which makes tumor position monitoring during each breath-hold important. A markerless technique is desirable, but limited tumor visibility on kV images makes this challenging. We evaluated if template matching + triangulation ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aac1a9
更新日期:2018-05-29 00:00:00
abstract::Infrared measurements have been used to profile or image biological tissue, including human skin. Usually, analysis of such measurements has assumed that infrared absorption is due to water and collagen. Such an assumption may be reasonable for soft tissue, but introduction of exogenous agents into skin or the measure...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/48/2/402
更新日期:2003-01-21 00:00:00
abstract::Quantitative assessment of mammographic asymmetry has been investigated for breast cancer risk prediction. A new asymmetry feature extraction method was proposed in this study to enhance the risk prediction accuracy of near-term breast cancer. Breast areas in each pair of bilateral mammographic images were divided int...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aae452
更新日期:2018-10-17 00:00:00
abstract::The aim of the study is to assess the staging value of the tumor heterogeneity characterized by texture features and other commonly used semi-quantitative indices extracted from (18)F-FDG PET images of cervical cancer (CC) patients. Forty-two patients suffering CC at different stages were enrolled in this study. First...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/13/5123
更新日期:2015-07-07 00:00:00
abstract::Absorbed dose values were determined under the reference conditions in a phantom irradiated by high-energy photon beams with quality varying between 60Co gamma rays and 25 MV X-rays, using four commonly employed types of ionisation chamber. The ionisation chamber readings were converted to absorbed dose values applyin...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/31/4/006
更新日期:1986-04-01 00:00:00
abstract::Complex intra-fractional motion and deformation of the liver significantly impacts the accuracy of delivered dose in radiotherapy. It limits margin reduction, dose escalation and normal tissue sparing. A critical component of motion management is to accurately reconstruct tumor motion. In this study, we developed a si...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab4c0d
更新日期:2019-11-21 00:00:00
abstract::This work presents an improvement of the VIPARnd ('nd' stands for 'normoxic, double', or VIP) polymer gel dosimeter. The gel composition was altered by increasing the concentration of the monomeric components, N-vinylpyrrolidone (NVP) and N,N'-methylenebisacrylamide (MBA), in co-solvent solutions. The optimal composit...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa5089
更新日期:2017-02-07 00:00:00
abstract::Crucial to all cancer therapy modalities is a strong correlation between treatment and effect. Predictability of therapy success/failure allows for the optimization of treatment protocol and aids in the decision of whether additional treatment is necessary to prevent tumour progression. This work evaluated the relatio...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/17/016
更新日期:2011-09-07 00:00:00
abstract::Recent research has suggested that endothelialization of vascular stents is crucial to reducing the risk of late stent thrombosis. With a resolution of approximately 10 microm, optical coherence tomography (OCT) may be an appropriate imaging modality for visualizing the vascular response to a stent and measuring the p...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/12/001
更新日期:2008-06-21 00:00:00
abstract::A mathematical transcription of the intrinsic circuit of the CA1 region of the rat dorsal hippocampus was made and the model parameters adjusted according to experimental data from intracellular recordings and single channel kinetics. This model was able to simulate well the profile of the field potentials recorded ex...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/43/9/014
更新日期:1998-09-01 00:00:00
abstract::Measurements of lung nodule volume with multi-detector computed tomography (MDCT) have been shown to be more accurate and precise compared to conventional lower dimensional measurements. Quantifying the size of lesions is potentially more difficult when the object-to-background contrast is low as with lesions in the l...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/2/671
更新日期:2015-01-21 00:00:00
abstract::Tumor motion is a particular concern for a complex treatment modality such as helical tomotherapy, where couch position, gantry rotation and MLC leaf opening all change with time. In the present study, we have investigated the impact of tumor motion for helical tomotherapy, which could result in three distinct motion-...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/19/004
更新日期:2009-10-07 00:00:00
abstract::The energy dependence of the luminance ratio due to scattered and primary radiation has been determined for four types of X-ray intensifying screens. A water phantom of 30 cm X 30 cm X 20 cm was used as the scattering medium. Ten narrow band X-ray spectra were used as incident radiation: the mean energies of these spe...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/29/10/007
更新日期:1984-10-01 00:00:00
abstract::Three major linear accelerator vendors offer gantry-mounted single (monoscopic) x-ray imagers. The use of monoscopic imaging to estimate three-dimensional (3D) target positions has not been fully explored. The purpose of this work is to develop and investigate a robust monoscopic method for real-time tumour tracking, ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/11/006
更新日期:2008-06-07 00:00:00
abstract::The measurand relevant for the dosimetry for radiation therapy is the absorbed dose to water, DW. The Physikalisch-Technische Bundesanstalt (PTB) is establishing a secondary standard for DW for high-energy photon and electron radiation based on electron spin resonance (ESR) of the amino acid alanine. For practical app...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/5/006
更新日期:2008-03-07 00:00:00
abstract::Incorrect prediction of skin dose in external beam radiotherapy (EBR) can have normal tissue complication such as acute skin desquamation and skin necrosis. The absorbed dose of skin should be evaluated within basal layer, placed between the epidermis and dermis layers. However, current treatment planning systems (TPS...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab2ef5
更新日期:2019-08-14 00:00:00
abstract::This work is dedicated to the reduction of reconstruction artefacts due to motion occurring during the acquisition of computerized tomographic projections. This problem has to be solved when imaging moving organs such as the lungs or the heart. The proposed method belongs to the class of motion compensation algorithms...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/49/11/004
更新日期:2004-06-07 00:00:00
abstract::Numerous studies of early-stage breast cancer treated with breast conserving surgery (BCS) and radiotherapy (RT) have been published in recent years. Both external beam radiotherapy (EBRT) and/or brachytherapy (BT) with different fractionation schemes are currently used. The present RT practice is largely based on emp...
journal_title:Physics in medicine and biology
pub_type: 杂志文章,meta分析
doi:10.1088/0031-9155/48/20/004
更新日期:2003-10-21 00:00:00
abstract::The aim of the present work was to implement the kinetics of cisplatin into a previously developed tumour growth model and to simulate the combined cisplatin-radiotherapy treatment with the emphasis on time sequencing and scheduling of drug and radiation. An investigation into whether the effect of cisplatin-radiation...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/51/15/002
更新日期:2006-08-07 00:00:00
abstract::The dose distribution near a non-radioactive gold seed under a 6 MV photon beam was measured using radiographic film, water equivalent bolus and solid water slabs. This type of small seed is typically used as a marker in target positional verification using a portal imager for conformal prostate treatment such as inte...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/50/18/N02
更新日期:2005-09-21 00:00:00
abstract::The effects of radiation damage, tumour repopulation and cell sublethal damage repair and the possibility of extracting information about the model parameters describing them are investigated in this work. Previously published data on two different cultured cell lines were analysed with the help of a tumour control pr...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/50/13/006
更新日期:2005-07-07 00:00:00
abstract::The measurement of output factors (OF) for the small photon beams generated by Leksell Gamma Knife® (LGK) radiotherapy units is a challenge for the physicist due to the under or over estimation of these factors by a vast majority of the detectors commercially available. Output correction factors, introduced in the int...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/10/3959
更新日期:2015-05-21 00:00:00