A modular Geant4 model of Leksell Gamma Knife Perfexion™.

Abstract:

:This work presents a Monte Carlo model of Leksell Gamma Knife Perfexion as well as the main parameters of the dose distribution in the standard phantom obtained using this model. The model is developed in the Geant4 simulation toolkit in a modular way which enables its reuse in other Perfexion studies. Large phase space files were created, containing particles that are entering the inner machine cavity after being transported through the collimation system. All 14 output factors of the machine and effective output factors for both the 4 mm (0.830 ± 0.009) and 8 mm (0.921 ± 0.004) collimators were calculated. Dose profiles along the main axes are also included for each collimator size. All results are compared to the values obtained from the treatment planning system, from experiments, and from other Monte Carlo models.

journal_name

Phys Med Biol

authors

Pipek J,Novotný J,Novotný J,Kozubíková P

doi

10.1088/0031-9155/59/24/7609

subject

Has Abstract

pub_date

2014-12-21 00:00:00

pages

7609-23

issue

24

eissn

0031-9155

issn

1361-6560

journal_volume

59

pub_type

杂志文章
  • Direct detection of 6 MV x-rays from a medical linear accelerator using a semiconducting polymer diode.

    abstract::Recently, a new family of low-cost x-radiation detectors have been developed, based on semiconducting polymer diodes, which are easy to process, mechanically flexible, relatively inexpensive, and able to cover large areas. To test their potential for radiotherapy applications such as beam monitors or dosimeters, as an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/13/4471

    authors: Mills CA,Chan YF,Intaniwet A,Shkunov M,Nisbet A,Keddie JL,Sellin PJ

    更新日期:2013-07-07 00:00:00

  • An experimental evaluation of the Agility MLC for motion-compensated VMAT delivery.

    abstract::An algorithm for dynamic multileaf-collimator (dMLC) tracking of a target performing a known a priori, rigid-body motion during volumetric modulated arc therapy (VMAT), has been experimentally validated and applied to investigate the potential of the Agility (Elekta AB, Stockholm, Sweden) multileaf-collimator (MLC) fo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/13/4643

    authors: Davies GA,Clowes P,Bedford JL,Evans PM,Webb S,Poludniowski G

    更新日期:2013-07-07 00:00:00

  • Recovery of total I-131 activity within focal volumes using SPECT and 3D OSEM.

    abstract::We experimentally investigated the SPECT recovery of I-131 activity in multiple spheres located simultaneously at different locations within a cylindrical phantom that had an elliptical cross section. The sphere volumes ranged from 209 cc down to 4.2 cc. A Prism 3000 camera and two types of parallel-hexagonal-hole col...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/3/017

    authors: Koral KF,Yendiki A,Dewaraja YK

    更新日期:2007-02-07 00:00:00

  • Penetration of electromagnetic fields of an open-ended coaxial probe between 1 MHz and 1 GHz in dielectric skin measurements.

    abstract::An open-ended coaxial probe is often used for investigating the dielectric properties of biological tissues. The present study indicates that in addition to the probe size, the penetration of the electromagnetic (EM) fields of an open-ended coaxial probe in contact with the skin is dependent on the applied frequency b...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/7/404

    authors: Alanen E,Lahtinen T,Nuutinen J

    更新日期:1999-07-01 00:00:00

  • On the impact of longitudinal breathing motion randomness for tomotherapy delivery.

    abstract::The purpose of this study is to explain the unplanned longitudinal dose modulations that appear in helical tomotherapy (HT) dose distributions in the presence of irregular patient breathing. This explanation is developed by the use of longitudinal (1D) simulations of mock and surrogate data and tested with a fully 4D ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/18/001

    authors: Kissick MW,Flynn RT,Westerly DC,Hoban PW,Mo X,Soisson ET,McCall KC,Mackie TR,Jeraj R

    更新日期:2008-09-21 00:00:00

  • Fast calibration of SPECT monolithic scintillation detectors using un-collimated sources.

    abstract::Monolithic scintillation detectors for positron emission tomography and single-photon emission computed tomography (SPECT) imaging have many advantages over pixelated detectors. The use of monolithic crystals allows for reducing the scintillator cost per unit volume and increasing the sensitivity along with the energy...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/14/4807

    authors: España S,Deprez K,Van Holen R,Vandenberghe S

    更新日期:2013-07-21 00:00:00

  • Monte Carlo calculation of beam quality correction factors for PTW cylindrical ionization chambers in photon beams.

    abstract::The beam quality correction factor k Q for megavoltage photon beams has been calculated for eight PTW (Freiburg, Germany) ionization chambers (Farmer chambers PTW30010, PTW30011, PTW30012, and PTW30013, Semiflex 3D chambers PTW31021, PTW31010, and PTW31013, and the PinPoint 3D chamber PTW31016). Simulations performed ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9501

    authors: Giménez-Alventosa V,Giménez V,Ballester F,Vijande J,Andreo P

    更新日期:2020-10-07 00:00:00

  • A new optimal wavelength for treatment of port wine stains?

    abstract::In this study we investigate light penetration into skin in order to define the optimal wavelength for the treatment of port wine stains. A two-layer model (epidermis and dermis) is applied with a cylindric tube representing the ectatic blood vessel. Light propagation is calculated by the Monte Carlo method. Values fo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/10/001

    authors: Kienle A,Hibst R

    更新日期:1995-10-01 00:00:00

  • The IPEM code of practice for determination of the reference air kerma rate for HDR (192)Ir brachytherapy sources based on the NPL air kerma standard.

    abstract::This paper contains the recommendations of the high dose rate (HDR) brachytherapy working party of the UK Institute of Physics and Engineering in Medicine (IPEM). The recommendations consist of a Code of Practice (COP) for the UK for measuring the reference air kerma rate (RAKR) of HDR (192)Ir brachytherapy sources. I...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/11/011

    authors: Bidmead AM,Sander T,Locks SM,Lee CD,Aird EG,Nutbrown RF,Flynn A,IPEM Working Party.

    更新日期:2010-06-07 00:00:00

  • A technique for the fast calculation of three-dimensional photon dose distributions using the superposition model.

    abstract::Techniques for reducing computation time in 3D photon dose calculations are addressed with specific emphasis given to the convolution/superposition approach. A single polyenergetic superposition model calculating absorbed dose per incident photon fluence (Gy cm2) was developed in terms of TERMA and a total energy depo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/8/001

    authors: Aspradakis MM,Redpath AT

    更新日期:1997-08-01 00:00:00

  • Tumour oxygen dynamics measured simultaneously by near-infrared spectroscopy and 19F magnetic resonance imaging in rats.

    abstract::Simultaneous near-infrared spectroscopy (NIRS) and magnetic resonance imaging (MRI) were used to investigate the correlation between tumour vascular oxygenation and tissue oxygen tension dynamics in rat breast 13762NF tumours with respect to hyperoxic gas breathing. NIRS directly detected global variations in the oxyg...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/1/004

    authors: Xia M,Kodibagkar V,Liu H,Mason RP

    更新日期:2006-01-07 00:00:00

  • Reassessing the clinical efficacy of two MR quantitative DSC PWI CBF algorithms following cross-calibration with PET images.

    abstract::Clinical cerebral blood flow (CBF) maps generated through dynamic- susceptibility contrast (DSC) magnetic resonance (MR) perfusion imaging are currently cross-calibrated with PET studies. The cross-calibration is achieved by rescaling the MR CBF values so that normal white matter CBF corresponds to 22 ml/100 g/min. Ex...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/6/014

    authors: Chen JJ,Frayne R,Smith MR

    更新日期:2005-03-21 00:00:00

  • A 3D reconstruction algorithm for magneto-acoustic tomography with magnetic induction based on ultrasound transducer characteristics.

    abstract::In this study we present a three-dimensional (3D) reconstruction algorithm for magneto-acoustic tomography with magnetic induction (MAT-MI) based on the characteristics of the ultrasound transducer. The algorithm is investigated to solve the blur problem of the MAT-MI acoustic source image, which is caused by the ultr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/61/24/8762

    authors: Ma R,Zhou X,Zhang S,Yin T,Liu Z

    更新日期:2016-12-21 00:00:00

  • Regional compensation for statistical maximum likelihood reconstruction error of PET image pixels.

    abstract::In positron emission tomography (PET), there is an increasing interest in studying not only the regional mean tracer concentration, but its variation arising from local differences in physiology, the tissue heterogeneity. However, in reconstructed images this physiological variation is shadowed by a large reconstructi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/14/4849

    authors: Forma J,Niemi JA,Ruotsalainen U

    更新日期:2013-07-21 00:00:00

  • Assessment of induced radio-frequency electromagnetic fields in various anatomical human body models.

    abstract::The reference levels for testing compliance of human exposure with radio-frequency (RF) safety limits have been derived from very simplified models of the human. In order to validate these findings for anatomical models, we investigated the absorption characteristics for various anatomies ranging from 6 year old child...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/4/004

    authors: Kühn S,Jennings W,Christ A,Kuster N

    更新日期:2009-02-21 00:00:00

  • Intraoperative evaluation of device placement in spine surgery using known-component 3D-2D image registration.

    abstract::Intraoperative x-ray radiography/fluoroscopy is commonly used to assess the placement of surgical devices in the operating room (e.g. spine pedicle screws), but qualitative interpretation can fail to reliably detect suboptimal delivery and/or breach of adjacent critical structures. We present a 3D-2D image registratio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa62c5

    authors: Uneri A,De Silva T,Goerres J,Jacobson MW,Ketcha MD,Reaungamornrat S,Kleinszig G,Vogt S,Khanna AJ,Osgood GM,Wolinsky JP,Siewerdsen JH

    更新日期:2017-04-21 00:00:00

  • Diaphragm correction factors for free-air chamber standards for air kerma in x-rays.

    abstract::At present, only a correction factor for photon transmission, k(l), is systematically applied for the entrance diaphragm of free-air chamber standards for air kerma. In the present work, the Monte Carlo code PENELOPE is used to re-evaluate k(l) for the BIPM standards and new correction factors are calculated for photo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/9/009

    authors: Burns DT,Kessler C

    更新日期:2009-05-07 00:00:00

  • Positron range estimations with PeneloPET.

    abstract::Technical advances towards high resolution PET imaging try to overcome the inherent physical limitations to spatial resolution. Positrons travel in tissue until they annihilate into the two gamma photons detected. This range is the main detector-independent contribution to PET imaging blurring. To a large extent, it c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/15/5127

    authors: Cal-González J,Herraiz JL,España S,Corzo PM,Vaquero JJ,Desco M,Udias JM

    更新日期:2013-08-07 00:00:00

  • Comment on 'egs_brachy: a versatile and fast Monte Carlo code for brachytherapy'.

    abstract::In a recent paper (Chamberland et al 2016 Phys. Med. Biol. 61 8214) develop a new Monte Carlo code called egs_brachy for brachytherapy treatments. It is based on EGSnrc, and written in the C++ programming language. In order to benchmark the egs_brachy code, the authors use it in various test case scenarios in which co...

    journal_title:Physics in medicine and biology

    pub_type: 评论,杂志文章,信件

    doi:10.1088/1361-6560/aa9ea1

    authors: Yegin G

    更新日期:2018-02-02 00:00:00

  • Improved method of in vivo respiratory-gated micro-CT imaging.

    abstract::The presence of motion artifacts is a typical problem in thoracic imaging. However, synchronizing the respiratory cycle with computed tomography (CT) image acquisition can reduce these artifacts. We currently employ a method of in vivo respiratory-gated micro-CT imaging for small laboratory animals (mice). This proced...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/17/023

    authors: Walters EB,Panda K,Bankson JA,Brown E,Cody DD

    更新日期:2004-09-07 00:00:00

  • An optimized leaf-setting algorithm for beam intensity modulation using dynamic multileaf collimators.

    abstract::A leaf-setting algorithm is developed for generating arbitrary beam intensity profiles in discrete levels using dynamic multileaf collimators (DMLCs). The algorithm starts with the algebraic expression for the area under the beam profile. It is shown that the coefficients in this expression can be transformed into the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/6/019

    authors: Ma L,Boyer AL,Xing L,Ma CM

    更新日期:1998-06-01 00:00:00

  • Dosimetry for the MRI accelerator: the impact of a magnetic field on the response of a Farmer NE2571 ionization chamber.

    abstract::The UMC Utrecht is constructing a 1.5 T MRI scanner integrated with a linear accelerator (Lagendijk et al 2008 Radiother. Oncol. 86 25-9). The goal of this device is to facilitate soft-tissue contrast based image-guided radiotherapy, in order to escalate the dose to the tumour while sparing surrounding normal tissues....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/10/002

    authors: Meijsing I,Raaymakers BW,Raaijmakers AJ,Kok JG,Hogeweg L,Liu B,Lagendijk JJ

    更新日期:2009-05-21 00:00:00

  • Automatic bladder segmentation on CBCT for multiple plan ART of bladder cancer using a patient-specific bladder model.

    abstract::In multiple plan adaptive radiotherapy (ART) strategies of bladder cancer, a library of plans corresponding to different bladder volumes is created based on images acquired in early treatment sessions. Subsequently, the plan for the smallest PTV safely covering the bladder on cone-beam CT (CBCT) is selected as the pla...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/12/3945

    authors: Chai X,van Herk M,Betgen A,Hulshof M,Bel A

    更新日期:2012-06-21 00:00:00

  • Modified sector-integration method for predicting the output factors of electron beams including extended source to surface distance.

    abstract::A modified sector-integration method is presented that can predict the output factors of irregular shaped electron fields even in the case of extended source to surface distance (SSD). The model takes as input measured output factors for circular inserts of various radii. These circular fields were measured at SSDs of...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/11/318

    authors: Choi DR,Wolters J,Mason D,Baillie A

    更新日期:2000-11-01 00:00:00

  • Applying a new maximum local asymmetry feature analysis method to improve near-term breast cancer risk prediction.

    abstract::Quantitative assessment of mammographic asymmetry has been investigated for breast cancer risk prediction. A new asymmetry feature extraction method was proposed in this study to enhance the risk prediction accuracy of near-term breast cancer. Breast areas in each pair of bilateral mammographic images were divided int...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aae452

    authors: Yan S,Zhang L,Song C

    更新日期:2018-10-17 00:00:00

  • PDE-constrained LDDMM via geodesic shooting and inexact Gauss-Newton-Krylov optimization using the incremental adjoint Jacobi equations.

    abstract::The class of non-rigid registration methods proposed in the framework of PDE-constrained large deformation diffeomorphic metric mapping is a particularly interesting family of physically meaningful diffeomorphic registration methods. Inexact Gauss-Newton-Krylov optimization has shown an excellent numerical accuracy an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaf598

    authors: Hernandez M

    更新日期:2019-01-07 00:00:00

  • A robust state-space kinetics-guided framework for dynamic PET image reconstruction.

    abstract::Dynamic PET image reconstruction is a challenging issue due to the low SNR and the large quantity of spatio-temporal data. We propose a robust state-space image reconstruction (SSIR) framework for activity reconstruction in dynamic PET. Unlike statistically-based frame-by-frame methods, tracer kinetic modeling is inco...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/8/010

    authors: Tong S,Alessio AM,Kinahan PE,Liu H,Shi P

    更新日期:2011-04-21 00:00:00

  • Residual motion compensation in ECG-gated interventional cardiac vasculature reconstruction.

    abstract::Three-dimensional reconstruction of cardiac vasculature from angiographic C-arm CT (rotational angiography) data is a major challenge. Motion artefacts corrupt image quality, reducing usability for diagnosis and guidance. Many state-of-the-art approaches depend on retrospective ECG-gating of projection data for image ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/11/3717

    authors: Schwemmer C,Rohkohl C,Lauritsch G,Müller K,Hornegger J

    更新日期:2013-06-07 00:00:00

  • Sources of Atomic and Nuclear Data for Biomedical Purposes.

    abstract::Users of nuclear and atomic data for biomedical purposes often have difficulty in identifying the most up-to-date and appropriate sources of such data. The biomedical Subcommittee of the UK Nuclear Data Committee have prepared a list of recommended data sources available at the beginning of 1978 on radioactive decay s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/24/1/001

    authors: Holt PD

    更新日期:1979-01-01 00:00:00

  • Computational dosimetry for grounded and ungrounded human models due to contact current.

    abstract::This study presents the computational dosimetry of contact currents for grounded and ungrounded human models. The uncertainty of the quasi-static (QS) approximation of the in situ electric field induced in a grounded/ungrounded human body due to the contact current is first estimated. Different scenarios of cylindrica...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/15/5153

    authors: Chan KH,Hattori J,Laakso I,Hirata A,Taki M

    更新日期:2013-08-07 00:00:00