Measurement and correction of the effects of lag on contrast-detail test results in fluoroscopy.

Abstract:

:Persistence of the video signal between TV frames, an effect also known as image lag, can lead to anomalously good contrast-detail test results for fluoroscopy systems. In this practical paper, a simple method is described which quantifies lag in fluoroscopy systems and corrects for its effect on threshold contrast. A digital framestore was used to acquire temporally contiguous fluoroscopy images. Correlation of the variance between an initial base TV frame and successive later frames was then measured via the correlation coefficient. Plotted against time, this function defines a time constant which characterizes the rate at which the initial variance pattern is replaced by incoming quantum noise. A survey of seven fluoroscopy units incorporating vacuum TV camera tubes found a mean time constant of 0.06 s. The relative change in contrast-detail performance was then measured as a function of applied digital frame averaging for two separate fluoroscopy units. A time constant was found for each frame averaging mode using the correlation of variance between frames. These measurements were used to derive a function which corrects contrast-detail results obtained for a unit with a measured nominal time constant to the typical vacuum camera tube time constant of 0.06 s. The correction is shown to significantly reduce the spread of contrast-detail results obtained over a range of temporal filtration settings.

journal_name

Phys Med Biol

authors

Marshall NW,Kotre CJ

subject

Has Abstract

pub_date

2002-03-21 00:00:00

pages

947-60

issue

6

eissn

0031-9155

issn

1361-6560

journal_volume

47

pub_type

杂志文章
  • Medical personnel and patient dosimetry during coronary angiography and intervention.

    abstract::Percutaneous coronary interventions are associated with increased radiation exposure compared to most radiological examinations. This prospective study aimed at (1) measuring entrance doses for all in-room personnel, (2) performing an assessment of patient effective dose and intracoronary doses, (3) investigating the ...

    journal_title:Physics in medicine and biology

    pub_type: 临床试验,杂志文章

    doi:10.1088/0031-9155/48/18/307

    authors: Efstathopoulos EP,Makrygiannis SS,Kottou S,Karvouni E,Giazitzoglou E,Korovesis S,Tzanalaridou E,Raptou PD,Katritsis DG

    更新日期:2003-09-21 00:00:00

  • Simultaneous Tc-99m/I-123 dual-radionuclide myocardial perfusion/innervation imaging using Siemens IQ-SPECT with SMARTZOOM collimator.

    abstract::Simultaneous dual-radionuclide myocardial perfusion/innervation SPECT imaging can provide important information about the mismatch between scar tissue and denervated regions. The Siemens IQ-SPECT system developed for cardiac imaging uses a multifocal SMARTZOOM collimator to achieve a four-fold sensitivity for the card...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/11/2813

    authors: Du Y,Bhattacharya M,Frey EC

    更新日期:2014-06-07 00:00:00

  • Optical attenuation characteristics of breast tissues at visible and near-infrared wavelengths.

    abstract::Optical experiments are described for measuring the attenuation characteristics of breast tissues at visible and near-infrared wavelengths. Total attenuation coefficients post mortem were measured directly in thin tissue sections. They are usually within the range from 10 to 30 mm-1, are rather higher in fat than in f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/5/002

    authors: Key H,Davies ER,Jackson PC,Wells PN

    更新日期:1991-05-01 00:00:00

  • Analytic treatment of resolution precision in electronically collimated SPECT imaging involving multiple-interaction gamma rays.

    abstract::The widely applied single-interaction analytic expression characterizing the energy resolution component of the angular resolution precision for an electronically collimated point source is extended to include multiple-interaction Compton scatter sequences as well as sequences terminated by photoelectric absorption. T...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/10/021

    authors: Durkee JW Jr,Antich PP,Tsyganov EN,Constantinescu A,Kulkarni PV,Smith BJ,Arbique GM,Lewis MA,Nguyen T,Raheja A,Thambi G,Parkey RW

    更新日期:1998-10-01 00:00:00

  • Comment on 'egs_brachy: a versatile and fast Monte Carlo code for brachytherapy'.

    abstract::In a recent paper (Chamberland et al 2016 Phys. Med. Biol. 61 8214) develop a new Monte Carlo code called egs_brachy for brachytherapy treatments. It is based on EGSnrc, and written in the C++ programming language. In order to benchmark the egs_brachy code, the authors use it in various test case scenarios in which co...

    journal_title:Physics in medicine and biology

    pub_type: 评论,杂志文章,信件

    doi:10.1088/1361-6560/aa9ea1

    authors: Yegin G

    更新日期:2018-02-02 00:00:00

  • An analysis of the accuracy of magnetic resonance flip angle measurement methods.

    abstract::Several methods of flip angle mapping for magnetic resonance imaging have been proposed. We evaluated the accuracy of five methods of flip angle measurement in the presence of measurement noise. Our analysis was performed in a closed form by propagation of probability density functions (PDFs). The flip angle mapping m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/20/008

    authors: Morrell GR,Schabel MC

    更新日期:2010-10-21 00:00:00

  • Investigation of the refractive index decrement of 3D printing materials for manufacturing breast phantoms for phase contrast imaging.

    abstract::3D breast modelling for 2D and 3D breast x-ray imaging would benefit from the availability of digital and physical phantoms that reproduce accurately the complexity of the breast anatomy. While a number of groups have produced digital phantoms with increasing level of complexity, physical phantoms reproducing that sof...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab0670

    authors: Esposito G,Mettivier G,Bliznakova K,Bliznakov Z,Bosmans H,Bravin A,Buliev I,Di Lillo F,Ivanov D,Minutillo M,Sarno A,Vignero J,Russo P

    更新日期:2019-03-27 00:00:00

  • Survey of numerical electrostimulation models.

    abstract::This paper evaluates results of a survey of electrostimulation models of myelinated nerve. Participants were asked to determine thresholds of excitation for 18 cases involving different characteristics of the neuron, the stimulation waveform, and the electrode arrangement. Responses were received from 7 investigators ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/12/4346

    authors: Reilly JP

    更新日期:2016-06-21 00:00:00

  • Front-illuminated versus back-illuminated photon-counting CCD-based gamma camera: important consequences for spatial resolution and energy resolution.

    abstract::Charge-coupled devices (CCDs) coupled to scintillation crystals can be used for high-resolution imaging with x-rays and gamma rays. When the CCD images can be read out fast enough, the energy and interaction position of individual gamma quanta can be estimated by a real-time image analysis of the scintillation light f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/8/N01

    authors: Heemskerk JW,Westra AH,Linotte PM,Ligtvoet KM,Zbijewski W,Beekman FJ

    更新日期:2007-04-21 00:00:00

  • Liver-ultrasound based motion modelling to estimate 4D dose distributions for lung tumours in scanned proton therapy.

    abstract::Motion mitigation strategies are crucial for scanned particle therapy of mobile tumours in order to prevent geometrical target miss and interplay effects. We developed a patient-specific respiratory motion model based on simultaneously acquired time-resolved volumetric MRI and 2D abdominal ultrasound images. We presen...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abaa26

    authors: Giger AT,Krieger M,Jud C,Duetschler A,Salomir R,Bieri O,Bauman G,Nguyen D,Weber DC,Lomax AJ,Zhang Y,Cattin PC

    更新日期:2020-07-28 00:00:00

  • The influence of a clear layer on near-infrared spectrophotometry measurements using a liquid neonatal head phantom.

    abstract::It is difficult to test near-infrared spectrophotometry instruments in vivo. Therefore we constructed a liquid phantom which mimics the neonatal head. It consists of a spherical 3.5 mm thick layer of silicone rubber simulating skin and bone and a 0.5 mm thick clear layer of polypropylene imitating cerebrospinal fluid....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/7/313

    authors: Wolf M,Keel M,Dietz V,von Siebenthal K,Bucher HU,Baenziger O

    更新日期:1999-07-01 00:00:00

  • A method for estimating radiation interaction coefficients for tissues from single energy CT.

    abstract::A parametric model for the x-ray linear attenuation coefficient is used to describe the compositional dependence of Hounsfield numbers measured by medical CT scanners. Measurements with materials of known density and composition, that span and evenly sample the compositional range of tissues, are written as linear sim...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/23/7479

    authors: Midgley SM

    更新日期:2014-12-07 00:00:00

  • Molybdenum target specifications for cyclotron production of 99mTc based on patient dose estimates.

    abstract::In response to the recognized fragility of reactor-produced (99)Mo supply, direct production of (99m)Tc via (100)Mo(p,2n)(99m)Tc reaction using medical cyclotrons has been investigated. However, due to the existence of other Molybdenum (Mo) isotopes in the target, in parallel with (99m)Tc, other technetium (Tc) radioa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/2/542

    authors: Hou X,Tanguay J,Buckley K,Schaffer P,Bénard F,Ruth TJ,Celler A

    更新日期:2016-01-21 00:00:00

  • Comparison of build-up dose between Elekta and Varian linear accelerators for high-energy photon beams using radiochromic film and clinical implications for IMRT head and neck treatments.

    abstract::Skin toxicity has been reported for IMRT of head and neck cancer. The purpose of this study was to investigate the dose in the build-up region delivered by a 6 MV treatment plan for which important skin toxicity was observed. We also investigated if the different designs of the treatment head of an Elekta and a Varian...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/3/002

    authors: Paelinck L,De Wagter C,Van Esch A,Duthoy W,Depuydt T,De Neve W

    更新日期:2005-02-07 00:00:00

  • Comparative behaviour of the dynamically penalized likelihood algorithm in inverse radiation therapy planning.

    abstract::This paper presents a description of tests carried out to compare the behaviour of five algorithms in inverse radiation therapy planning: (1) The Dynamically Penalized Likelihood (DPL), an algorithm based on statistical estimation theory; (2) an accelerated version of the same algorithm: (3) a new fast adaptive simula...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/10/309

    authors: Llacer J,Solberg TD,Promberger C

    更新日期:2001-10-01 00:00:00

  • Quantitative analysis of synchrotron radiation intravenous angiographic images.

    abstract::A medical research protocol on clinical intravenous coronary angiography has been completed at the European Synchrotron Radiation Facility (ESRF) biomedical beamline. The aim was to investigate the accuracy of intravenous coronary angiography based on the K-edge digital subtraction technique for the detection of in-st...

    journal_title:Physics in medicine and biology

    pub_type: 临床试验,杂志文章

    doi:10.1088/0031-9155/50/4/011

    authors: Sarnelli A,Nemoz C,Elleaume H,Estève F,Bertrand B,Bravin A

    更新日期:2005-02-21 00:00:00

  • Photon detection efficiency of laboratory-based x-ray phase contrast imaging techniques for mammography: a Monte Carlo study.

    abstract::An important challenge in real-world biomedical applications of x-ray phase contrast imaging (XPCI) techniques is the efficient use of the photon flux generated by an incoherent and polychromatic x-ray source. This efficiency can directly influence dose and exposure time and ideally should not affect the superior cont...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa7a92

    authors: Saghamanesh S,Aghamiri SM,Kamali-Asl A,Yashiro W

    更新日期:2017-09-01 00:00:00

  • Evaluation of the induced electric field and compliance procedure for a wireless power transfer system in an electrical vehicle.

    abstract::In this study, an induced electric field in a human body is evaluated for the magnetic field leaked from a wireless power transfer system for charging an electrical vehicle. The magnetic field from the wireless power transfer system is modelled computationally, and its effectiveness is confirmed by comparison with the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/21/7583

    authors: Laakso I,Hirata A

    更新日期:2013-11-07 00:00:00

  • Volumetric CT with sparse detector arrays (and application to Si-strip photon counters).

    abstract::Novel x-ray medical imaging sensors, such as photon counting detectors (PCDs) and large area CCD and CMOS cameras can involve irregular and/or sparse sampling of the detector plane. Application of such detectors to CT involves undersampling that is markedly different from the commonly considered case of sparse angular...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/1/90

    authors: Sisniega A,Zbijewski W,Stayman JW,Xu J,Taguchi K,Fredenberg E,Lundqvist M,Siewerdsen JH

    更新日期:2016-01-07 00:00:00

  • Internal dosimetry with the Monte Carlo code GATE: validation using the ICRP/ICRU female reference computational model.

    abstract::The purpose of this work was to validate GATE-based clinical scale absorbed dose calculations in nuclear medicine dosimetry. GATE (version 6.2) and MCNPX (version 2.7.a) were used to derive dosimetric parameters (absorbed fractions, specific absorbed fractions and S-values) for the reference female computational model...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/62/5/1885

    authors: Villoing D,Marcatili S,Garcia MP,Bardiès M

    更新日期:2017-03-07 00:00:00

  • Low-frequency conductivity tensor imaging with a single current injection using DT-MREIT.

    abstract::Diffusion tensor - magnetic resonance electrical impedance tomography (DT-MREIT) is an imaging modality to obtain low-frequency anisotropic conductivity distribution employing diffusion tensor imaging (DTI) and magnetic resonance electrical impedance tomography (MREIT) techniques. DT-MREIT is based on the linear relat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abddcf

    authors: Sadighi M,Sisman M,Acikgoz BC,Eroglu HH,Eyuboglu BM

    更新日期:2021-01-20 00:00:00

  • Multi-layer imager design for mega-voltage spectral imaging.

    abstract::The architecture of multi-layer imagers (MLIs) can be exploited to provide megavoltage spectral imaging (MVSPI) for specific imaging tasks. In the current work, we investigated bone suppression and gold fiducial contrast enhancement as two clinical tasks which could be improved with spectral imaging. A method based on...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aabe21

    authors: Myronakis M,Hu YH,Fueglistaller R,Wang A,Baturin P,Huber P,Morf D,Star-Lack J,Berbeco R

    更新日期:2018-05-10 00:00:00

  • An FDK-like cone-beam SPECT reconstruction algorithm for non-uniform attenuated projections acquired using a circular trajectory.

    abstract::In this paper, Novikov's inversion formula of the attenuated two-dimensional (2D) Radon transform is applied to the reconstruction of attenuated fan-beam projections acquired with equal detector spacing and of attenuated cone-beam projections acquired with a flat planar detector and circular trajectory. The derivation...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/10/010

    authors: Huang Q,Zeng GL,You J,Gullberg GT

    更新日期:2005-05-21 00:00:00

  • The ArcCHECK diode array for dosimetric verification of HybridArc.

    abstract::The aim of this work is to evaluate dosimetric accuracy of a new treatment modality, HybridArc, in iPlan RT Dose 4.5 (BrainLAB, Feldkirchen, Germany) using a four-dimensional diode array (ArcCHECK, Sun Nuclear Corporation, Melbourne, USA). HybridArc is able to enhance dynamic conformal arcs with inversely planned elem...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/16/021

    authors: Petoukhova AL,van Egmond J,Eenink MG,Wiggenraad RG,van Santvoort JP

    更新日期:2011-08-21 00:00:00

  • Estimating cancer risk from dental cone-beam CT exposures based on skin dosimetry.

    abstract::The aim of this study was to measure entrance skin doses on patients undergoing cone-beam computed tomography (CBCT) examinations, to establish conversion factors between skin and organ doses, and to estimate cancer risk from CBCT exposures. 266 patients (age 8-83) were included, involving three imaging centres. CBCT ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/14/3877

    authors: Pauwels R,Cockmartin L,Ivanauskaité D,Urbonienė A,Gavala S,Donta C,Tsiklakis K,Jacobs R,Bosmans H,Bogaerts R,Horner K,SEDENTEXCT Project Consortium.

    更新日期:2014-07-21 00:00:00

  • Including robustness in multi-criteria optimization for intensity-modulated proton therapy.

    abstract::We present a method to include robustness in a multi-criteria optimization (MCO) framework for intensity-modulated proton therapy (IMPT). The approach allows one to simultaneously explore the trade-off between different objectives as well as the trade-off between robustness and nominal plan quality. In MCO, a database...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/3/591

    authors: Chen W,Unkelbach J,Trofimov A,Madden T,Kooy H,Bortfeld T,Craft D

    更新日期:2012-02-07 00:00:00

  • Automatic bladder segmentation on CBCT for multiple plan ART of bladder cancer using a patient-specific bladder model.

    abstract::In multiple plan adaptive radiotherapy (ART) strategies of bladder cancer, a library of plans corresponding to different bladder volumes is created based on images acquired in early treatment sessions. Subsequently, the plan for the smallest PTV safely covering the bladder on cone-beam CT (CBCT) is selected as the pla...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/12/3945

    authors: Chai X,van Herk M,Betgen A,Hulshof M,Bel A

    更新日期:2012-06-21 00:00:00

  • Comparative efficiency of the multi-leaf collimator and variable-aperture collimator in intensity-modulated radiotherapy.

    abstract::The potential of the variable-aperture collimator (VAC) in intensity-modulated radiation therapy (IMRT) has been evaluated by comparing its performance with that of the multi-leaf collimator (MLC). This comparison used a decomposition algorithm to find the series of collimator segments that would treat a given intensi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/7/006

    authors: Anderson JW,Symonds-Tayler R,Hartmann G,Echner G,Lang C,Schlegel W,Webb S

    更新日期:2006-04-07 00:00:00

  • Resolving fluorophores by unmixing multispectral fluorescence tomography with independent component analysis.

    abstract::It is a challenging problem to resolve and identify drug (or non-specific fluorophore) distribution throughout the whole body of small animals in vivo. In this article, an algorithm of unmixing multispectral fluorescence tomography (MFT) images based on independent component analysis (ICA) is proposed to solve this pr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/17/5025

    authors: Pu H,Zhang G,He W,Liu F,Guang H,Zhang Y,Bai J,Luo J

    更新日期:2014-09-07 00:00:00

  • Power deposition in the head and neck of an anatomically based human body model for plane wave exposures.

    abstract::At certain frequencies, when the human head becomes a resonant structure, the power absorbed by the head and neck, when the body is exposed to a vertically polarized plane wave propagating from front to back, becomes significantly larger than would ordinarily be expected from its shadow cross section. This has possibl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/8/026

    authors: Tinniswood AD,Furse CM,Gandhi OP