Abstract:
:Charge-coupled devices (CCDs) coupled to scintillation crystals can be used for high-resolution imaging with x-rays and gamma rays. When the CCD images can be read out fast enough, the energy and interaction position of individual gamma quanta can be estimated by a real-time image analysis of the scintillation light flashes ('photon-counting mode'). The electron-multiplying CCD (EMCCD) is well suited for fast read out, since even at high frame rates it has extremely low read-out noise. Back-illuminated (BI) EMCCDs have much higher quantum efficiency than front-illuminated (FI) EMCCDs. Here we compare the spatial and energy resolution of gamma cameras based on FI and BI EMCCDs. The CCDs are coupled to a 1000 microm thick columnar CsI(Tl) crystal for the purpose of Tc-99m and I-125 imaging. Intrinsic spatial resolutions of 44 microm for I-125 and 49 microm for Tc-99m were obtained when using a BI EMCCD, which is an improvement by a factor of about 1.2-2 over the FI EMCCD. Furthermore, in the energy spectrum of the BI EMCCD, the I-125 signal could be clearly separated from the background noise, which was not the case for the FI EMCCD. The energy resolution of a BI EMCCD for Tc-99m was estimated to be approximately 36 keV, full width at half maximum, at 141 keV. The excellent results for the BI EMCCD encouraged us to investigate the cooling requirements for our setup. We have found that for the BI EMCCD, the spatial and energy resolution, as well as image noise, remained stable over a range of temperatures from -50 degrees C to -15 degrees C. This is a significant advantage over the FI EMCCD, which suffered from loss of spatial and especially energy resolution at temperatures as low as -40 degrees C. We conclude that the use of BI EMCCDs may significantly improve the imaging capabilities and the cost efficiency of CCD-based high-resolution gamma cameras.
journal_name
Phys Med Bioljournal_title
Physics in medicine and biologyauthors
Heemskerk JW,Westra AH,Linotte PM,Ligtvoet KM,Zbijewski W,Beekman FJdoi
10.1088/0031-9155/52/8/N01subject
Has Abstractpub_date
2007-04-21 00:00:00pages
N149-62issue
8eissn
0031-9155issn
1361-6560pii
S0031-9155(07)33319-8journal_volume
52pub_type
杂志文章abstract::A parametric model for the x-ray linear attenuation coefficient is used to describe the compositional dependence of Hounsfield numbers measured by medical CT scanners. Measurements with materials of known density and composition, that span and evenly sample the compositional range of tissues, are written as linear sim...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/23/7479
更新日期:2014-12-07 00:00:00
abstract::Estimation of a set of parameters that describe the geometry of the cone-beam computed tomography system plays an important role in the geometrical calibration. In the calibration process, the helical phantom consisting of spherical markers arranged on a helical trajectory has been widely applied. To directly determin...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/19/5667
更新日期:2014-10-07 00:00:00
abstract::Iterative image reconstruction algorithms have the potential to produce low noise images. Early stopping of the iteration process is problematic because some features of the image may converge slowly. On the other hand, there may be noise build-up with increased number of iterations. Therefore, we examined the stabili...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/49/20/004
更新日期:2004-10-21 00:00:00
abstract::Computational phantoms are commonly used in internal radiation dosimetry to assess the amount and distribution pattern of energy deposited in various parts of the human body from different internal radiation sources. Radiation dose assessments are commonly performed on predetermined reference computational phantoms wh...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa75b4
更新日期:2017-07-13 00:00:00
abstract::A general theory is presented for minimizing noise in linear dimension reduction of sequences of medical images when the factors and the covariance matrix and mean of the noise are given. A dimension reduction is optimal when all diagonal elements in the covariance matrix of the noise in the signal (factor) space are ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/40/11/010
更新日期:1995-11-01 00:00:00
abstract::Using Monte Carlo simulation of 99Tcm single-photon-emission computed tomography (SPECT), we investigate the effects of tissue-background activity, tumour location, patient size, uncertainty of energy windows, and definition of tumour region on the accuracy of quantification. The dual-energy-window method of correctio...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/40/1/015
更新日期:1995-01-01 00:00:00
abstract::At present, only a correction factor for photon transmission, k(l), is systematically applied for the entrance diaphragm of free-air chamber standards for air kerma. In the present work, the Monte Carlo code PENELOPE is used to re-evaluate k(l) for the BIPM standards and new correction factors are calculated for photo...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/9/009
更新日期:2009-05-07 00:00:00
abstract::A method of computing optimized intensity-modulated beam profiles has been further developed and used to generate highly conformal radiotherapy dose distributions. The features of these distributions are shown to be strongly dependent on the tuning built into the algorithm. The optimization aims to achieve a specified...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/39/12/007
更新日期:1994-12-01 00:00:00
abstract::The development and improvement of techniques for an accurate dose assessment in medical physics is an important task. In this study, we focus on the validation of Monte Carlo calculations, by comparing organ doses assessed experimentally with thermoluminescent detectors in the Rando-Alderson phantom with doses calcul...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/20/018
更新日期:2008-10-21 00:00:00
abstract::Online proton range/dose verification based on measurements of proton-induced positron emitters is a promising strategy for quality assurance in proton therapy. Because of the nonlinear correlation between the dose distribution and the activity distribution of positron emitters, we aim to establish their relationship ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab3564
更新日期:2019-09-04 00:00:00
abstract::In BANG gel dosimetry, the spin-spin relaxation rate, R2 = I/T2, is related to the radiation dose that has been delivered to the gel phantom. R2 is calculated by fitting the pixel intensities of a set of differently T2-weighted base images. In gel dosimetry for radiotherapy, an accuracy of 5% in dose and 3 mm spatiall...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/45/7/307
更新日期:2000-07-01 00:00:00
abstract::Spectral x-ray imaging using novel photon counting x-ray detectors (PCDs) with energy resolving abilities is capable of providing energy-selective images. PCDs have energy thresholds, enabling the classification of photons into multiple energy bins. The extra energy information provided may allow materials such as iod...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/18/012
更新日期:2011-09-21 00:00:00
abstract::A system is described in which large superficial areas of tissue may be heated using a single plane ultrasonic transducer scanned in a raster fashion. The shape of the heated area is determined by the movement of a microswitch which is activated when it strikes the rigid edge of a hole of the required shape cut in a p...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/30/12/006
更新日期:1985-12-01 00:00:00
abstract::A method for quantifying the tissue sodium concentration (TSC) in the rat brain from ²³Na-MR images was developed. TSC is known to change in a variety of common human diseases and holds considerable potential to contribute to their study; however, its accurate measurement in small laboratory animals has been hindered ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/24/019
更新日期:2010-12-21 00:00:00
abstract::Ultrasound-based elastography including strain elastography, acoustic radiation force impulse (ARFI) imaging, point shear wave elastography and supersonic shear imaging (SSI) have been used to differentiate breast tumors among other clinical applications. The objective of this study is to extend a previously published...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa58c9
更新日期:2017-03-07 00:00:00
abstract::Temperature distributions resulting from hyperthermia treatments on isolated perfused bovine tongues were compared with simulations by a treatment planning system. The aim was to test whether the discrete vessel model used for the treatment planning is able to predict correct generic temperature distributions. Tongues...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/43/5/011
更新日期:1998-05-01 00:00:00
abstract::Recently, there has been an increased interest in imaging different pulmonary disorders using PET techniques. Previous work has shown, for static PET/CT, that air content in the lung influences reconstructed image values and that it is vital to correct for this 'tissue fraction effect' (TFE). In this paper, we extend ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/18/7387
更新日期:2015-09-21 00:00:00
abstract::Treatment planning for proton tumor therapy requires a fast and accurate dose-calculation method. We have implemented a simplified Monte Carlo (SMC) method in the treatment planning system of the National Cancer Center Hospital East for the double-scattering beam delivery scheme. The SMC method takes into account the ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/12/018
更新日期:2010-06-21 00:00:00
abstract::The sensitivity and detection limit for measurements of the concentration of cadmium in the kidney cortex of man in vivo have been investigated using the technique of X-ray fluorescence. An 11 GB1 241Am source was used to generate the characteristic K alpha X-rays of cadmium. The variation in the sensitivity for the d...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/26/1/004
更新日期:1981-01-01 00:00:00
abstract::Numerous studies have reported the measurements of the dielectric properties of the skin. Clarifying the manner in which the human body interacts with electromagnetic waves is essential for medical research and development, as well as for the safety assessment of electromagnetic wave exposure. The skin comprises sever...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/16/4739
更新日期:2014-08-21 00:00:00
abstract::Coincidence resolving time (CRT) is one of the most important physical-performance measures for positron emission tomography (PET), as reconstruction with accurate time-of-flight information enhances the lesion detectability in patient studies. Accordingly, various PET detector designs and high-performance front-end r...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aaf0bb
更新日期:2018-12-10 00:00:00
abstract::Several types of intravascular ultrasound (IVUS) catheters are connected to a motor at their proximal end, in order to let the catheter rotate around its length axis. However, the rotation of the distal axis tip does not follow exactly the rotation of the motor, since the catheter axis is not completely torsion-free a...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/43/5/001
更新日期:1998-05-01 00:00:00
abstract::Values of W (the mean energy required to create an ion pair when a charged particle is stopped in a gas) are needed in radiation dosimetry to convert ionisation chamber current readings to absorbed dose. For neutron dosimetry the most important W values are those for protons, and this paper describes absolute measurem...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/30/11/003
更新日期:1985-11-01 00:00:00
abstract::In this paper we present the results of a dosimetric evaluation of a 2D ionization chamber array with the objective of its implementation for quality assurance in clinical routine. The pixel ionization chamber MatriXX (Scanditronix Wellhofer, Germany) consists of 32x32 chambers with a distance of 7.6 mm between chambe...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/4/023
更新日期:2007-02-21 00:00:00
abstract::Fluorescence molecular tomography (FMT) is widely used in preclinical oncology research. FMT is the only imaging technique able to provide 3D distribution of fluorescent probes within thick highly scattering media. However, its integration into clinical medicine has been hampered by its low spatial resolution caused b...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aaf96d
更新日期:2019-01-22 00:00:00
abstract::Several applications in nuclear medicine require absolute activity quantification of single photon emission computed tomography images. Obtaining a repeatable calibration factor that converts voxel values to activity units is essential for these applications. Because source preparation and measurement of the source ac...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/3/1325
更新日期:2015-02-07 00:00:00
abstract::This study investigates the dosimetric impact of using population-based Hounsfield units (HUs) and ICRU-based HUs as a function of the number of tissue segments for bulk density assignment toward MRI-based treatment planning in the abdomen. To avoid potential geometric differences between CT and MR images, CT images r...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aacfb1
更新日期:2018-07-24 00:00:00
abstract::Radiotherapy and particle therapy treatment planning require accurate knowledge of the electron density and elemental composition of the tissues in the beam path to predict the local dose deposition. We describe a method for the analysis of dual energy computed tomography (DECT) images that provides the electron densi...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/9/3825
更新日期:2015-05-07 00:00:00
abstract::The measurement of output factors (OF) for the small photon beams generated by Leksell Gamma Knife® (LGK) radiotherapy units is a challenge for the physicist due to the under or over estimation of these factors by a vast majority of the detectors commercially available. Output correction factors, introduced in the int...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/10/3959
更新日期:2015-05-21 00:00:00
abstract::To achieve accurate and fast deformable image registration (DIR) for pulmonary CT, we proposed a Multi-scale DIR framework with unsupervised Joint training of Convolutional Neural Network (MJ-CNN). MJ-CNN contains three models at multi-scale levels for a coarse-to-fine DIR to avoid being trapped in a local minimum. It...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab5da0
更新日期:2020-01-13 00:00:00