Abstract:
:Effective use of the [Formula: see text] decay chain in targeted internal radioimmunotherapy requires the retention of both [Formula: see text] and progeny isotopes at the target site. Imaging-based pharmacokinetic tests of these pharmaceuticals must therefore separately yet simultaneously image multiple isotopes that may not be colocalized despite being part of the same decay chain. This work presents feasibility studies demonstrating the ability of a microSPECT/CT scanner equipped with a high energy collimator to simultaneously image two components of the [Formula: see text] decay chain: [Formula: see text] (218 keV) and [Formula: see text] (440 keV). Image quality phantoms were used to assess the performance of two collimators for simultaneous [Formula: see text] and [Formula: see text] imaging in terms of contrast and noise. A hotrod resolution phantom containing clusters of thin rods with diameters ranging between 0.85 and 1.70 mm was used to assess resolution. To demonstrate ability to simultaneously image dynamic [Formula: see text] and [Formula: see text] activity distributions, a phantom containing a [Formula: see text] generator from [Formula: see text] was imaged. These tests were performed with two collimators, a high-energy ultra-high resolution (HEUHR) collimator and an ultra-high sensitivity (UHS) collimator. Values consistent with activity concentrations determined independently via gamma spectroscopy were observed in high activity regions of the images. In hotrod phantom images, the HEUHR collimator resolved all rods for both [Formula: see text] and [Formula: see text] images. With the UHS collimator, no rods were resolvable in [Formula: see text] images and only rods ⩾1.3 mm were resolved in [Formula: see text] images. After eluting the [Formula: see text] generator, images accurately visualized the reestablishment of transient equilibrium of the [Formula: see text] decay chain. The feasibility of evaluating the pharmacokinetics of the [Formula: see text] decay chain in vivo has been demonstrated. This presented method requires the use of a high-performance high-energy collimator.
journal_name
Phys Med Bioljournal_title
Physics in medicine and biologyauthors
Robertson AKH,Ramogida CF,Rodríguez-Rodríguez C,Blinder S,Kunz P,Sossi V,Schaffer Pdoi
10.1088/1361-6560/aa6a99subject
Has Abstractpub_date
2017-06-07 00:00:00pages
4406-4420issue
11eissn
0031-9155issn
1361-6560journal_volume
62pub_type
杂志文章abstract::Dynamic contrast-enhanced computed tomography (DCE-CT) is an imaging tool that aids in evaluating functional characteristics of tissue at different stages of disease management: diagnostic, radiation treatment planning, treatment effectiveness, and monitoring. Clinical validation of DCE-derived perfusion parameters re...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/17/6111
更新日期:2013-09-07 00:00:00
abstract::In this work, a methodology for using a smartphone camera, in conjunction with a light-tight box operating in reflective transmission mode, is investigated as a proof of concept for use as a film dosimetry system. An imaging system was designed to allow the camera of a smartphone to be used as a pseudo densitometer. T...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa8b36
更新日期:2017-10-03 00:00:00
abstract::The aim of the present work was to implement the kinetics of cisplatin into a previously developed tumour growth model and to simulate the combined cisplatin-radiotherapy treatment with the emphasis on time sequencing and scheduling of drug and radiation. An investigation into whether the effect of cisplatin-radiation...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/51/15/002
更新日期:2006-08-07 00:00:00
abstract::Cylindrical homogenous phantoms for magnetic resonance (MR) elastography in biomedical research provide one way to validate an imaging systems performance, but the simplified geometry and boundary conditions can cloak complexity arising at tissue interfaces. In an effort to develop a more realistic gel tissue phantom ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/61/18/6821
更新日期:2016-09-21 00:00:00
abstract::A method of computing theoretical X-ray spectra in the range 30-150 kV is presented. The theoretical spectra are compared with constant potential, high resolution spectra from a tungsten target measured with a Ge(Li) detector, for a range of target angles, tube voltage and filtrations. Above 100 kV the spectra were al...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/24/3/002
更新日期:1979-05-01 00:00:00
abstract::In this paper the propagation of a UWB pulse into a layered model of the human body is studied to characterize absorption and reflection of the UWB signal due to the different body tissues. Several time behaviours for the incident UWB pulse are considered and compared with reference to the feasibility of breath and he...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/24/8689
更新日期:2013-12-21 00:00:00
abstract::Positron emission tomography (PET) has become an important modality in medical and molecular imaging. However, in most PET applications, the resolution is still mainly limited by the physical crystal sizes or the detector's intrinsic spatial resolution. To achieve images with better spatial resolution in a central reg...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/2/647
更新日期:2015-01-21 00:00:00
abstract::We investigate the effect of multiple scattering on the optical coherence tomography (OCT) signal and the Doppler OCT signal of flowing blood. Doppler OCT measurements at 1300 nm are performed on flowing diluted porcine blood with hematocrit ranging between 0% and 15%. Measured blood hematocrit and mean red blood cell...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/7/1907
更新日期:2012-04-07 00:00:00
abstract::Using MRI for radiotherapy treatment planning and image guidance is appealing as it provides superior soft tissue information over CT scans and avoids possible systematic errors introduced by aligning MR to CT images. This study presents a method that generates Synthetic CT (MRCT) volumes by performing probabilistic t...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/62/8/2935
更新日期:2017-04-21 00:00:00
abstract::We have developed a model using Monte Carlo methods to simulate x-ray mammography. All possible physical processes of interaction of x-rays with matter have been taken into account. A simplified geometry of the mammographic apparatus has been considered along with a software phantom of compressed breast. The phantom m...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/43/11/012
更新日期:1998-11-01 00:00:00
abstract::The first trimester fetal ultrasound scan is important to confirm fetal viability, to estimate the gestational age of the fetus, and to detect fetal anomalies early in pregnancy. First trimester ultrasound images have a different appearance than for the second trimester scan, reflecting the different stage of fetal de...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab3ad1
更新日期:2019-09-17 00:00:00
abstract::The phosphor GdO2S:Tb is widely used in camera-based electronic portal imaging devices (EPIDs). There is considerable interest in the application of EPIDs to dosimetry and the verification of intensity modulated radiation therapy produced by dynamic multileaf collimation (DMLC). This paper presents direct measurement ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/46/2/317
更新日期:2001-02-01 00:00:00
abstract::As automation in radiation oncology becomes more common, it is important to determine which algorithms are equivalent for a given workflow. Often, algorithm comparisons are performed in isolation; however, clinical context can provide valuable insight into the importance of algorithm features and error magnification i...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab9fc8
更新日期:2020-09-28 00:00:00
abstract::The measurand relevant for the dosimetry for radiation therapy is the absorbed dose to water, DW. The Physikalisch-Technische Bundesanstalt (PTB) is establishing a secondary standard for DW for high-energy photon and electron radiation based on electron spin resonance (ESR) of the amino acid alanine. For practical app...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/5/006
更新日期:2008-03-07 00:00:00
abstract::Energy-resolved attenuation data in spectral x-ray imaging enables material decomposition, in which the different materials inside an object can be identified and separated virtually. Material decomposition has the drawback of increased noise in the resulting material images relative to the measured images. Recently, ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aba318
更新日期:2020-10-07 00:00:00
abstract::A Monte Carlo computational model of a fluoroscopic imaging chain was used for deriving optimal technique factors for paediatric fluoroscopy. The optimal technique was defined as the one that minimizes the absorbed dose (or dose rate) in the patient with a constraint of constant image quality. Image quality was assess...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/44/2/018
更新日期:1999-02-01 00:00:00
abstract::The total system error (TSE) of a CyberKnife® system was measured using two phantom-based methods and one patient-based method. The standard radiochromic film (RCF) end-to-end (E2E) test using an anthropomorphic head and neck phantom and isocentric treatment delivery was used with the 6Dskull, Fiducial and Xsight® spi...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aad516
更新日期:2018-08-20 00:00:00
abstract::A new function to treat tetrahedral-mesh geometry was implemented in the particle and heavy ion transport code systems. To accelerate the computational speed in the transport process, an original algorithm was introduced to initially prepare decomposition maps for the container box of the tetrahedral-mesh geometry. Th...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa6b45
更新日期:2017-06-21 00:00:00
abstract::A mathematical model has been constructed to simulate the response of cells in vitro to fractionated doses of radiation. The model is capable of describing most of the radiobiological functions that are commonly studied. Input data are measurable cell properties. The details of the model and methods of acquiring the i...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/21/5/011
更新日期:1976-09-01 00:00:00
abstract::Radiotherapy calculations often involve complex geometries such as interfaces between materials of vastly differing atomic number, such as lung, bone and/or air interfaces. Monte Carlo methods have been used to calculate accurately the perturbation effects of the interfaces. However, these methods can be computational...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/51/9/010
更新日期:2006-05-07 00:00:00
abstract::Does the posture of a patient have an effect on the organ and tissue absorbed doses caused by x-ray examinations? This study aims to find the answer to this question, based on Monte Carlo (MC) simulations of commonly performed x-ray examinations using adult phantoms modelled to represent humans in standing as well as ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/15/014
更新日期:2010-08-07 00:00:00
abstract::A method is presented to predict beam profiles and outputs for wedged asymmetric fields defined by independent collimator jaws allowing fast generation of beam profiles whilst requiring very little additional data to that already used by most treatment planning systems in generating symmetric field isodoses. Symmetric...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/39/1/004
更新日期:1994-01-01 00:00:00
abstract::Detectors used for positron emission tomography (PET) provide fast, randomly distributed signals that need to be digitized for further processing. One possibility is to sample the signals at the peak initiated by a trigger from a constant fraction discriminator (CFD). For PET detectors, simultaneous acquisition of man...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/50/1/003
更新日期:2005-01-07 00:00:00
abstract::The dosimetrical characteristics of a new miniature multileaf collimator (ModuLeaf MLC, MRC Systems GmbH, Heidelberg, Germany) attached to the accessory holder of a Siemens accelerator with 6 MV x-rays (PRIMUS, Siemens OCS, Concord, California, USA) have been investigated. In particular, those parameters which are imp...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/47/12/402
更新日期:2002-06-21 00:00:00
abstract::It is a challenging problem to resolve and identify drug (or non-specific fluorophore) distribution throughout the whole body of small animals in vivo. In this article, an algorithm of unmixing multispectral fluorescence tomography (MFT) images based on independent component analysis (ICA) is proposed to solve this pr...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/17/5025
更新日期:2014-09-07 00:00:00
abstract::The combined build-up and attenuation factor, B exp (-mu r), of point isotropic photon sources in a water medium has been calculated using the Monte Carlo method, for energies (20-1500 keV) and distances (1-10 cm) relevant in brachytherapy. For the transport of photons and electrons, up-to-date and self-consistent tot...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/36/6/005
更新日期:1991-06-01 00:00:00
abstract::In positron emission tomography (PET), there is an increasing interest in studying not only the regional mean tracer concentration, but its variation arising from local differences in physiology, the tissue heterogeneity. However, in reconstructed images this physiological variation is shadowed by a large reconstructi...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/14/4849
更新日期:2013-07-21 00:00:00
abstract::Kilo-voltage (KV) cone-beam computed tomography (CBCT) unit mounted onto a linear accelerator treatment system, often referred to as on-board imager (OBI), plays an increasingly important role in image-guided radiation therapy. While the FDK algorithm is currently used for reconstructing images from clinical OBI data,...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/12/4601
更新日期:2015-06-21 00:00:00
abstract::Generally, the inverse planning of radiation therapy consists mainly of the fluence optimization. The beam angle optimization (BAO) in intensity-modulated radiation therapy (IMRT) consists of selecting appropriate radiation incidence directions and may influence the quality of the IMRT plans, both to enhance better or...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/9/2939
更新日期:2013-05-07 00:00:00
abstract::Diffuse optical tomography is an imaging technique whereby spatial maps of absorption and scattering coefficients are derived from the characteristics of multiply scattered light transmitted through the object. The system described here used four intensity-modulated light sources and measurements of the intensity and ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/40/10/011
更新日期:1995-10-01 00:00:00