Scheduling cisplatin and radiotherapy in the treatment of squamous cell carcinomas of the head and neck: a modelling approach.

Abstract:

:The aim of the present work was to implement the kinetics of cisplatin into a previously developed tumour growth model and to simulate the combined cisplatin-radiotherapy treatment with the emphasis on time sequencing and scheduling of drug and radiation. An investigation into whether the effect of cisplatin-radiation is determined by independent cell kill or by cisplatin-produced radiosensitization was also undertaken. It was shown that cisplatin administered before radiation conferred similar tumour control to the post-radiation sequencing of the drug. The killing effect of the combined modality treatment on tumour increased with the increase in cell recruitment. Furthermore, the individual cell kill produced by the two cytotoxins led to an additive only tumour response when the treatments were given concurrently, suggesting that for a synergistic effect, cisplatin must potentiate the effect of radiation, through the radiosensitizing mechanisms addressed in the literature. It was concluded that the optimal timing of cisplatin should be close to radiation. The model showed that daily administration of cisplatin led to a 35% improvement of tumour control as compared to radiation alone, while weekly cisplatin has improved radiotherapy by only 6%.

journal_name

Phys Med Biol

authors

Marcu L,Bezak E,Olver I

doi

10.1088/0031-9155/51/15/002

subject

Has Abstract

pub_date

2006-08-07 00:00:00

pages

3625-37

issue

15

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(06)20969-2

journal_volume

51

pub_type

杂志文章
  • Comparison of build-up dose between Elekta and Varian linear accelerators for high-energy photon beams using radiochromic film and clinical implications for IMRT head and neck treatments.

    abstract::Skin toxicity has been reported for IMRT of head and neck cancer. The purpose of this study was to investigate the dose in the build-up region delivered by a 6 MV treatment plan for which important skin toxicity was observed. We also investigated if the different designs of the treatment head of an Elekta and a Varian...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/3/002

    authors: Paelinck L,De Wagter C,Van Esch A,Duthoy W,Depuydt T,De Neve W

    更新日期:2005-02-07 00:00:00

  • Evaluation of the basic properties of the BANGkit gel dosimeter.

    abstract::We evaluated the basic properties of a commercially available BANGkit gel dosimeter, which is a normoxic type of BANG gel. This gel-kit has the same composition as the BANG 3 gel, but is fully oxygenated. To exclude oxygen, oxygen scavenging ascorbic acid and copper sulfate as a catalyst are used. The properties that ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/8/017

    authors: Murakami Y,Nakashima T,Watanabe Y,Akimitsu T,Matsuura K,Kenjo M,Kaneyasu Y,Wadasaki K,Hirokawa Y,Ito K

    更新日期:2007-04-21 00:00:00

  • Image reconstruction and scan configurations enabled by optimization-based algorithms in multispectral CT.

    abstract::Optimization-based algorithms for image reconstruction in multispectral (or photon-counting) computed tomography (MCT) remains a topic of active research. The challenge of optimization-based image reconstruction in MCT stems from the inherently non-linear data model that can lead to a non-convex optimization program f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa8a4b

    authors: Chen B,Zhang Z,Sidky EY,Xia D,Pan X

    更新日期:2017-11-02 00:00:00

  • Artefacts in multi-echo T2 imaging for high-precision gel dosimetry: I. Analysis and compensation of eddy currents.

    abstract::In BANG gel dosimetry, the spin-spin relaxation rate, R2 = I/T2, is related to the radiation dose that has been delivered to the gel phantom. R2 is calculated by fitting the pixel intensities of a set of differently T2-weighted base images. In gel dosimetry for radiotherapy, an accuracy of 5% in dose and 3 mm spatiall...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/7/307

    authors: De Deene Y,De Wagter C,De Neve W,Achten E

    更新日期:2000-07-01 00:00:00

  • Use of forward projection to correct patient motion during SPECT imaging.

    abstract::We have developed an iterative method to correct axial and tangential patient motion occurring during tomographic acquisition. The method uses axial images reconstructed from the uncorrected projection images, which are then forward projected to form a basis for registering the original planar images and, in the proce...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/1/011

    authors: Lee KJ,Barber DC

    更新日期:1998-01-01 00:00:00

  • Elastic modulus imaging: some exact solutions of the compressible elastography inverse problem.

    abstract::We consider several inverse problems motivated by elastography. Given the (possibly transient) displacement field measured everywhere in an isotropic, compressible, linear elastic solid, and given density rho, determine the Lamé parameters lambda and mu. We consider several special cases of this problem: (a) for mu kn...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/6/003

    authors: Barbone PE,Oberai AA

    更新日期:2007-03-21 00:00:00

  • Modeling late rectal toxicities based on a parameterized representation of the 3D dose distribution.

    abstract::Many models exist for predicting toxicities based on dose-volume histograms (DVHs) or dose-surface histograms (DSHs). This approach has several drawbacks as firstly the reduction of the dose distribution to a histogram results in the loss of spatial information and secondly the bins of the histograms are highly correl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/7/013

    authors: Buettner F,Gulliford SL,Webb S,Partridge M

    更新日期:2011-04-07 00:00:00

  • Truncation artifact suppression in cone-beam radionuclide transmission CT using maximum likelihood techniques: evaluation with human subjects.

    abstract::Transverse image truncation can be a serious problem for human imaging using cone-beam transmission CT (CB-CT) implemented on a conventional rotating gamma camera. If this problem can be solved, CB-CT will be useful for attenuation compensation of SPECT images. This paper presents a reconstruction method to reduce or ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/3/004

    authors: Manglos SH

    更新日期:1992-03-01 00:00:00

  • A Monte Carlo-based method to estimate radiation dose from spiral CT: from phantom testing to patient-specific models.

    abstract::The purpose of this work is to develop and test a method to estimate the relative and absolute absorbed radiation dose from axial and spiral CT scans using a Monte Carlo approach. Initial testing was done in phantoms and preliminary results were obtained from a standard mathematical anthropomorphic model (MIRD V) and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/16/306

    authors: Jarry G,DeMarco JJ,Beifuss U,Cagnon CH,McNitt-Gray MF

    更新日期:2003-08-21 00:00:00

  • Exact solutions to the multiregion time-dependent bioheat equation. II: Numerical evaluation of the solutions.

    abstract::Analytic solutions to the time-dependent multiregion bioheat equation are evaluated numerically for cartesian and spherical models. Principle and alternate branch contributions to the solutions are examined. The calculations include a parametric investigation and analyses of temperature behaviour in idealised upper th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/35/7/005

    authors: Durkee JW Jr,Antich PP,Lee CE

    更新日期:1990-07-01 00:00:00

  • The distribution of trace elements Ca, Fe, Cu and Zn and the determination of copper oxidation state in breast tumour tissue using muSRXRF and muXANES.

    abstract::A micro beam synchrotron x-ray fluorescence (muSRXRF) technique has been used to determine the localization of metals in primary invasive ductal carcinoma of breast. Nine samples were examined, all of which were formalin fixed tissues arranged as micro arrays of 1.0 mm diameter and 10 microm thickness. Cu was the part...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/11/018

    authors: Farquharson MJ,Al-Ebraheem A,Falkenberg G,Leek R,Harris AL,Bradley DA

    更新日期:2008-06-07 00:00:00

  • The fast Padé transform in magnetic resonance spectroscopy for potential improvements in early cancer diagnostics.

    abstract::The convergence rates of the fast Padé transform (FPT) and the fast Fourier transform (FFT) are compared. These two estimators are used to process a time-signal encoded at 4 T by means of one-dimensional magnetic resonance spectroscopy (MRS) for healthy human brain. It is found systematically that at any level of trun...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/18/010

    authors: Belkić D,Belkić K

    更新日期:2005-09-21 00:00:00

  • End-to-end tests using alanine dosimetry in scanned proton beams.

    abstract::This paper describes end-to-end test procedures as the last fundamental step of medical commissioning before starting clinical operation of the MedAustron synchrotron-based pencil beam scanning (PBS) therapy facility with protons. One in-house homogeneous phantom and two anthropomorphic heterogeneous (head and pelvis)...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaac23

    authors: Carlino A,Gouldstone C,Kragl G,Traneus E,Marrale M,Vatnitsky S,Stock M,Palmans H

    更新日期:2018-02-26 00:00:00

  • T1 and extracellular volume fraction mapping in cardiac magnetic resonance: estimation of accuracy and precision of a novel algorithm.

    abstract::Magnetic resonance imaging is effective for non-invasive detection of myocardial diseases by extracellular volume fraction (ECV) estimation. A new methodology for T1 and ECV mapping is tested in this work, comparing results with other well-consolidated methods. The associated level of uncertainty for data was also est...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aafcca

    authors: Borrazzo C,Pacilio M,Galea N,Preziosi E,Carnì M,Francone M,Catalano C,Carbone I

    更新日期:2019-02-11 00:00:00

  • The feasibility of using poroelastographic techniques for distinguishing between normal and lymphedematous tissues in vivo.

    abstract::Lymphedema is a common condition involving an abnormal accumulation of lymphatic fluid in the interstitial space that causes swelling, most often in the arm(s) and leg(s). Lymphedema is a significant lifelong concern that can be congenital or develop following cancer treatment or cancer metastasis. Common methods of e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/21/013

    authors: Righetti R,Garra BS,Mobbs LM,Kraemer-Chant CM,Ophir J,Krouskop TA

    更新日期:2007-11-07 00:00:00

  • A comparison between track-structure, condensed-history Monte Carlo simulations and MIRD cellular S-values.

    abstract::The S-value is a standard measure in cellular dosimetry. S-values are calculated by applying analytical methods or by Monte Carlo simulation. In Monte Carlo simulation, particles are either tracked individually event-by-event or close events are condensed and processed collectively in different steps. Both of these me...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/62/5/N90

    authors: Tajik-Mansoury MA,Rajabi H,Mozdarani H

    更新日期:2017-03-07 00:00:00

  • Improving source detection and separation in a spatiotemporal Bayesian inference dipole analysis.

    abstract::Most existing spatiotemporal multi-dipole approaches for MEG/EEG source localization assume that the dipoles are active for the full time range being analysed. If the actual time range of activity of sources is significantly shorter than the time range being analysed, the detectability, localization and time-course de...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/10/004

    authors: Jun SC,George JS,Plis SM,Ranken DM,Schmidt DM,Wood CC

    更新日期:2006-05-21 00:00:00

  • Integral equations and boundary-element solution for static potential in a general piece-wise homogeneous volume conductor.

    abstract::Boundary element methods (BEM) are used for forward computation of bioelectromagnetic fields in multi-compartment volume conductor models. Most BEM approaches assume that each compartment is in contact with at most one external compartment. In this work, I present a general surface integral equation and BEM discretiza...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/22/N606

    authors: Stenroos M

    更新日期:2016-11-21 00:00:00

  • Monte Carlo and experimental evaluation of accuracy and noise properties of two scatter correction methods for SPECT.

    abstract::Scatter correction is a prerequisite for quantitative SPECT, but potentially increases noise. Monte Carlo simulations (EGS4) and physical phantom measurements were used to compare accuracy and noise properties of two scatter correction techniques: the triple-energy window (TEW), and the transmission dependent convolut...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/11/017

    authors: Narita Y,Eberl S,Iida H,Hutton BF,Braun M,Nakamura T,Bautovich G

    更新日期:1996-11-01 00:00:00

  • Radionuclides and carrier molecules for therapy.

    abstract::Although radionuclide therapy has been around for a long time, this modality of cancer treatment has been limited mainly to the use of [32P]-phosphate and [131I]-sodium iodide. The last few years, however, have seen an increased interest in this area due to new developments of radionuclides and carrier molecules that ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/41/10/004

    authors: Zweit J

    更新日期:1996-10-01 00:00:00

  • Improved precision of syndesmophyte measurement for the evaluation of ankylosing spondylitis using CT: a phantom and patient study.

    abstract::Ankylosing spondylitis is a disease characterized by abnormal bone formation (syndesmophyte) at the margins of inter-vertebral disc spaces. Syndesmophyte growth is currently typically monitored by the visual inspection of radiographs. The limitations inherent to the modality (2D projection of a 3D object) and rater (q...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/14/4683

    authors: Tan S,Yao J,Yao L,Ward MM

    更新日期:2012-07-21 00:00:00

  • 4D Monte Carlo simulation of proton beam scanning: modelling of variations in time and space to study the interplay between scanning pattern and time-dependent patient geometry.

    abstract::When dosimetric effects in time-dependent geometries are studied, usually either the results of individual three-dimensional (3D) calculations are combined or probability-based approaches are applied. These methods may become cumbersome and time-consuming if high time resolution is required or if the geometry is compl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/5/020

    authors: Paganetti H,Jiang H,Trofimov A

    更新日期:2005-03-07 00:00:00

  • Modelling of temperature and perfusion during scalp cooling.

    abstract::Hair loss is a feared side effect of chemotherapy treatment. It may be prevented by cooling the scalp during administration of cytostatics. The supposed mechanism is that by cooling the scalp, both temperature and perfusion are diminished, affecting drug supply and drug uptake in the hair follicle. However, the effect...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/17/010

    authors: Janssen FE,Van Leeuwen GM,Van Steenhoven AA

    更新日期:2005-09-07 00:00:00

  • Aerosol particle impaction in the conducting airways.

    abstract::Modelling of inhaled particle deposition in the lungs potentially offers data relevant to assessing hazards from toxic inhaled particles, to studying mucus clearance or lung permeability by aerosol techniques, and to achieving better utilisation of drugs administered as aerosols. Analysis of published modelling studie...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/7/001

    authors: Agnew JE,Pavia D,Clarke SW

    更新日期:1984-07-01 00:00:00

  • Real-time monitoring of focused ultrasound blood-brain barrier opening via subharmonic acoustic emission detection: implementation of confocal dual-frequency piezoelectric transducers.

    abstract::Burst-tone focused ultrasound exposure in the presence of microbubbles has been demonstrated to be effective at inducing temporal and local opening of the blood-brain barrier (BBB), which promises significant clinical potential to deliver therapeutic molecules into the central nervous system (CNS). Traditional contras...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/7/2926

    authors: Tsai CH,Zhang JW,Liao YY,Liu HL

    更新日期:2016-04-07 00:00:00

  • Development of advanced skin dose evaluation technique using a tetrahedral-mesh phantom in external beam radiotherapy: a Monte Carlo simulation study.

    abstract::Incorrect prediction of skin dose in external beam radiotherapy (EBR) can have normal tissue complication such as acute skin desquamation and skin necrosis. The absorbed dose of skin should be evaluated within basal layer, placed between the epidermis and dermis layers. However, current treatment planning systems (TPS...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2ef5

    authors: Cheon BW,Yoo DH,Shin WG,Choi HJ,Park HJ,Kim JI,Min CH

    更新日期:2019-08-14 00:00:00

  • Film dosimetry using a smart device camera: a feasibility study for point dose measurements.

    abstract::In this work, a methodology for using a smartphone camera, in conjunction with a light-tight box operating in reflective transmission mode, is investigated as a proof of concept for use as a film dosimetry system. An imaging system was designed to allow the camera of a smartphone to be used as a pseudo densitometer. T...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa8b36

    authors: Aland T,Jhala E,Kairn T,Trapp J

    更新日期:2017-10-03 00:00:00

  • Extension of the NCAT phantom for the investigation of intra-fraction respiratory motion in IMRT using 4D Monte Carlo.

    abstract::The purpose of this work was to create a computational platform for studying motion in intensity modulated radiotherapy (IMRT). Specifically, the non-uniform rational B-spline (NURB) cardiac and torso (NCAT) phantom was modified for use in a four-dimensional Monte Carlo (4D-MC) simulation system to investigate the eff...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/5/014

    authors: McGurk R,Seco J,Riboldi M,Wolfgang J,Segars P,Paganetti H

    更新日期:2010-03-07 00:00:00

  • Relative determination of W-values for alpha particles in tissue-equivalent and other gases.

    abstract::W (the average energy to form an ion pair) for 5.4 MeV 241Am alpha particles in a Rossi-type tissue-equivalent (TE) gas, argon and methane was determined to an accuracy better than 0.2% using a new automated data handling system. A vibrating reed electrometer and current digitiser were used to measure the current prod...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/24/2/005

    authors: Krieger GL,Baum JW,Varma MN,Beach JL

    更新日期:1979-03-01 00:00:00

  • Rigid motion correction of dual opposed planar projections in single photon imaging.

    abstract::Awake and/or freely moving small animal single photon emission imaging allows the continuous study of molecules exhibiting slow kinetics without the need to restrain or anaesthetise the animals. Estimating motion free projections in freely moving small animal planar imaging can be considered as a limited angle tomogra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa68cd

    authors: Angelis GI,Ryder WJ,Gillam JE,Boisson F,Kyme AZ,Fulton RR,Meikle SR,Kench PL

    更新日期:2017-05-21 00:00:00