Extension of the NCAT phantom for the investigation of intra-fraction respiratory motion in IMRT using 4D Monte Carlo.

Abstract:

:The purpose of this work was to create a computational platform for studying motion in intensity modulated radiotherapy (IMRT). Specifically, the non-uniform rational B-spline (NURB) cardiac and torso (NCAT) phantom was modified for use in a four-dimensional Monte Carlo (4D-MC) simulation system to investigate the effect of respiratory-induced intra-fraction organ motion on IMRT dose distributions as a function of diaphragm motion, lesion size and lung density. Treatment plans for four clinical scenarios were designed: diaphragm peak-to-peak amplitude of 1 cm and 3 cm, and two lesion sizes--2 cm and 4 cm diameter placed in the lower lobe of the right lung. Lung density was changed for each phase using a conservation of mass calculation. Further, a new heterogeneous lung model was implemented and tested. Each lesion had an internal target volume (ITV) subsequently expanded by 15 mm isotropically to give the planning target volume (PTV). The PTV was prescribed to receive 72 Gy in 40 fractions. The MLC leaf sequence defined by the planning system for each patient was exported and used as input into the MC system. MC simulations using the dose planning method (DPM) code together with deformable image registration based on the NCAT deformation field were used to find a composite dose distribution for each phantom. These composite distributions were subsequently analyzed using information from the dose volume histograms (DVH). Lesion motion amplitude has the largest effect on the dose distribution. Tumor size was found to have a smaller effect and can be mitigated by ensuring the planning constraints are optimized for the tumor size. The use of a dynamic or heterogeneous lung density model over a respiratory cycle does not appear to be an important factor with a

journal_name

Phys Med Biol

authors

McGurk R,Seco J,Riboldi M,Wolfgang J,Segars P,Paganetti H

doi

10.1088/0031-9155/55/5/014

subject

Has Abstract

pub_date

2010-03-07 00:00:00

pages

1475-90

issue

5

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(10)36673-5

journal_volume

55

pub_type

杂志文章
  • Understanding the limitations of ultrasonic backscatter measurements from microbubble populations.

    abstract::Despite over ten years of in vitro investigations of ultrasound contrast agents, the level of understanding of their behaviour in ultrasound fields is limited. Several problems associated with these investigations, particular to the nature of contrast agents, are discussed. Using a commercial scanner the RF normalized...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/23/313

    authors: Sboros V,Ramnarine KV,Moran CM,Pye SD,McDicken WN

    更新日期:2002-12-07 00:00:00

  • 3D thoracoscopic ultrasound volume measurement validation in an ex vivo and in vivo porcine model of lung tumours.

    abstract::The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial "tumours" were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the "tumours" were impl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/1/007

    authors: Hornblower VD,Yu E,Fenster A,Battista JJ,Malthaner RA

    更新日期:2007-01-07 00:00:00

  • The quality of ionising radiations emitted by radionuclides incorporated into mammalian cells.

    abstract::Radionuclides which decay by electron capture accompanied by Auger electron cascades, or by beta emission are thought to be excessively damaging when incorporated into the molecular structure of mammalian cell nuclei and thereby pose a radiation hazard which is not assessable by conventional dosimetry. Survival data, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/7/003

    authors: Younis AR,Watt DE

    更新日期:1989-07-01 00:00:00

  • Molybdenum target specifications for cyclotron production of 99mTc based on patient dose estimates.

    abstract::In response to the recognized fragility of reactor-produced (99)Mo supply, direct production of (99m)Tc via (100)Mo(p,2n)(99m)Tc reaction using medical cyclotrons has been investigated. However, due to the existence of other Molybdenum (Mo) isotopes in the target, in parallel with (99m)Tc, other technetium (Tc) radioa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/2/542

    authors: Hou X,Tanguay J,Buckley K,Schaffer P,Bénard F,Ruth TJ,Celler A

    更新日期:2016-01-21 00:00:00

  • A spectral approach to ultrasonic scattering from human tissue: methods, objectives and backscattering measurements.

    abstract::The dearth of information on the physical processes involved in the propagation of ultrasound in tissue and the growing need for such information are discussed. The physical nature of the ultrasonic diagnostic process in considered in terms of a wave phenomenon and the limitations and advantages of frequency spectral ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/20/5/009

    authors: Chivers RC,Hill CR

    更新日期:1975-09-01 00:00:00

  • Evaluation of inverse methods and head models for EEG source localization using a human skull phantom.

    abstract::We used a real-skull phantom head to investigate the performances of representative methods for EEG source localization when considering various head models. We describe several experiments using a montage with current sources located at multiple positions and orientations inside a human skull filled with a conductive...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/1/306

    authors: Baillet S,Riera JJ,Marin G,Mangin JF,Aubert J,Garnero L

    更新日期:2001-01-01 00:00:00

  • Comparison of recent codes of practice for high-energy photon dosimetry.

    abstract::Absorbed dose values were determined under the reference conditions in a phantom irradiated by high-energy photon beams with quality varying between 60Co gamma rays and 25 MV X-rays, using four commonly employed types of ionisation chamber. The ionisation chamber readings were converted to absorbed dose values applyin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/4/006

    authors: Mijnheer BJ,Wittkämper FW

    更新日期:1986-04-01 00:00:00

  • The influence of penetrating radiation on collimator performance.

    abstract::Geometric and penetration responses of a multihole focusing collimator to a point source have been determined using a digital computer and a ray tracing technique. Results are presented as point and line spread functions for collimated rays and penetrating rays, and as plane sensitivities and modulation transfer funct...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/26/1/011

    authors: Jahns MJ

    更新日期:1981-01-01 00:00:00

  • Comment on 'egs_brachy: a versatile and fast Monte Carlo code for brachytherapy'.

    abstract::In a recent paper (Chamberland et al 2016 Phys. Med. Biol. 61 8214) develop a new Monte Carlo code called egs_brachy for brachytherapy treatments. It is based on EGSnrc, and written in the C++ programming language. In order to benchmark the egs_brachy code, the authors use it in various test case scenarios in which co...

    journal_title:Physics in medicine and biology

    pub_type: 评论,杂志文章,信件

    doi:10.1088/1361-6560/aa9ea1

    authors: Yegin G

    更新日期:2018-02-02 00:00:00

  • The importance of radiometer angular response for ultraviolet phototherapy dosimetry.

    abstract::The influence of the angular response of radiometer probes on measurements of irradiance in ultraviolet phototherapy has been studied. Irradiance measurements were made using nine ultraviolet (UV) radiometers employed by phototherapy centres in Scotland and Northern Ireland, and compared with measurements made using t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/4/003

    authors: Martin CJ,Currie GD,Pye SD

    更新日期:1999-04-01 00:00:00

  • Neutron scattering cross sections and partial kerma values for oxygen, nitrogen and calcium at 18 less than En less than 60 MeV.

    abstract::Recent measurements of differential elastic and inelastic neutron scattering from oxygen, nitrogen and calcium at 18 less than En less than 26 MeV are presented and analysed in terms of the optical model. These data, together with earlier measurements of scattering and total cross sections, are used to construct model...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/33/3/001

    authors: Islam MS,Finlay RW,Petler JS,Rapaport J,Alarcon R,Wierzbicki J

    更新日期:1988-03-01 00:00:00

  • Optimizing spectral CT parameters for material classification tasks.

    abstract::In this work, we propose a framework for optimizing spectral CT imaging parameters and hardware design with regard to material classification tasks. Compared with conventional CT, many more parameters must be considered when designing spectral CT systems and protocols. These choices will impact material classification...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/12/4599

    authors: Rigie DS,La Rivière PJ

    更新日期:2016-06-21 00:00:00

  • Automatic bladder segmentation on CBCT for multiple plan ART of bladder cancer using a patient-specific bladder model.

    abstract::In multiple plan adaptive radiotherapy (ART) strategies of bladder cancer, a library of plans corresponding to different bladder volumes is created based on images acquired in early treatment sessions. Subsequently, the plan for the smallest PTV safely covering the bladder on cone-beam CT (CBCT) is selected as the pla...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/12/3945

    authors: Chai X,van Herk M,Betgen A,Hulshof M,Bel A

    更新日期:2012-06-21 00:00:00

  • Quantitative evaluation of myocardial function by a volume-normalized map generated from relative blood flow.

    abstract::Our study aimed to quantitatively evaluate blood flow in the left ventricle (LV) of apical hypertrophic cardiomyopathy (APH) by combining wall thickness obtained from cardiac magnetic resonance imaging (MRI) and myocardial perfusion from single-photon emission computed tomography (SPECT). In this study, we considered ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/14/019

    authors: Fukami T,Sato H,Wu J,Lwin TT,Yuasa T,Kawano S,Iida K,Akatsuka T,Hontani H,Takeda T,Tamura M,Yokota H

    更新日期:2007-07-21 00:00:00

  • Modulated photon radiotherapy (XMRT): an algorithm for the simultaneous optimization of photon beamlet energy and intensity in external beam radiotherapy (EBRT) planning.

    abstract::This is a proof of principle study on an algorithm for optimizing external beam radiotherapy in terms of both photon beamlet energy and fluence. This simultaneous beamlet energy and fluence optimization is denoted modulated photon radiotherapy (XMRT). XMRT is compared with single-energy intensity modulated radiotherap...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/4/1476

    authors: McGeachy P,Villarreal-Barajas JE,Zinchenko Y,Khan R

    更新日期:2016-02-21 00:00:00

  • Correlation between dosimetric effect and intrafraction motion during prostate treatments delivered with helical tomotherapy.

    abstract::The dosimetric impact of intrafraction prostate motion was investigated for helical tomotherapy treatments. Measured motion tracks were used to calculate the dosimetric impact on delivered target dose distributions. A dynamic dose calculation engine was developed to facilitate this evaluation. It was found that the D9...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/24/005

    authors: Langen KM,Lu W,Ngwa W,Willoughby TR,Chauhan B,Meeks SL,Kupelian PA,Olivera G

    更新日期:2008-12-21 00:00:00

  • Generalised use of contrast degradation and contrast improvement factors in diagnostic radiology. Application to vanishing contrast.

    abstract::Although field area and object thickness are important parameters in comparisons of techniques for optimal reduction of scattered radiation to the image, they are in practice seldom varied. For this reason, we suggest that contrast degradation (CDF) and contrast improvement (CIF) factors be more frequently used and ap...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/7/004

    authors: Carlsson GA,Carlsson CA,Nielsen B,Persliden J

    更新日期:1986-07-01 00:00:00

  • Regional compensation for statistical maximum likelihood reconstruction error of PET image pixels.

    abstract::In positron emission tomography (PET), there is an increasing interest in studying not only the regional mean tracer concentration, but its variation arising from local differences in physiology, the tissue heterogeneity. However, in reconstructed images this physiological variation is shadowed by a large reconstructi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/14/4849

    authors: Forma J,Niemi JA,Ruotsalainen U

    更新日期:2013-07-21 00:00:00

  • Monte Carlo study of x-ray detection configurations for benchtop x-ray fluorescence computed tomography of gold nanoparticle-loaded objects.

    abstract::Over the last decade, the performance of benchtop x-ray fluorescence computed tomography (XFCT) systems has been significantly enhanced through hardware and software optimizations. Recent studies have indicated the need of energy-resolving pixelated/array detectors in the x-ray detection component to further improve t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9774

    authors: Moktan H,Ahmed MF,Jayarathna S,Deng L,Cho SH

    更新日期:2020-08-31 00:00:00

  • Filter materials for dose reduction in screen-film radiography.

    abstract::A computer program was developed to calculate both integral absorbed dose in a water phantom and entrance exposure, for the imaging of iodine contrast with x-ray intensifying screens. The effect of filtration of the x-ray beam on integral absorbed dose and entrance exposure was studied for 27 different filter material...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/6/001

    authors: Koedooder K,Venema HW

    更新日期:1986-06-01 00:00:00

  • The effect of temporal HU variations on the uncertainty of dose recalculations performed on MVCT images.

    abstract::Over the course of radiation therapy, a patient's anatomy may change substantially. The relatively recent addition of frequent in-room imaging to assist with patient localization has provided a database of images that may be used to recalculate dose distributions for adaptive radiotherapy purposes. The TomoTherapy Hi-...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/24/010

    authors: Pukala J,Meeks SL,Bova FJ,Langen KM

    更新日期:2011-12-21 00:00:00

  • Comparison of two respiration monitoring systems for 4D imaging with a Siemens CT using a new dynamic breathing phantom.

    abstract::Four-dimensional computed tomography (4D-CT) requires breathing information from the patient, and for this, several systems are available. Testing of these systems, under realistic conditions, requires a phantom with a moving target and an expandable outer contour. An anthropomorphic phantom was developed to simulate ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/9/N131

    authors: Vásquez AC,Runz A,Echner G,Sroka-Perez G,Karger CP

    更新日期:2012-05-07 00:00:00

  • New materials for dielectric simulation of tissues.

    abstract::Two novel materials have been developed to simulate the dielectric properties of human muscle and fat at 1000 MHz. These materials, which are based on ethanediol set with gelatine, are easily made and have good mechanical properties. The complex permittivity, epsilon *, of each material was measured with an open-ended...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/12/002

    authors: Robinson MP,Richardson MJ,Green JL,Preece AW

    更新日期:1991-12-01 00:00:00

  • The use of gel dosimetry for verification of electron and photon treatment plans in carcinoma of the scalp.

    abstract::In recent years there has been a large amount of research into the potential use of radiation sensitive gels for three-dimensional verification of clinical radiotherapy doses. In this paper we report the use of a MAGIC gel dosimeter (Fong et al 2001 Phys. Med. Biol. 46 3105) for the verification of a specific patient'...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/9/003

    authors: Trapp JV,Partridge M,Hansen VN,Childs P,Bedford J,Warrington AP,Leach MO,Webb S

    更新日期:2004-05-07 00:00:00

  • The effective attenuation coefficient of soft tissue in the presence of Compton scattering from bone: experiments on models.

    abstract::Calibration methods are investigated for the determination of bone density by the Compton scattering method. The scattered radiation from materials of different densities and dimensions is measured for this purpose. A function for the dependence of the intensity on these parameters is derived and compared with the exp...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/4/009

    authors: Leichter I,Weinreb A,Hazan G

    更新日期:1980-07-01 00:00:00

  • Segmentation of dynamic PET images with kinetic spectral clustering.

    abstract::Segmentation is often required for the analysis of dynamic positron emission tomography (PET) images. However, noise and low spatial resolution make it a difficult task and several supervised and unsupervised methods have been proposed in the literature to perform the segmentation based on semi-automatic clustering of...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/19/6931

    authors: Mouysset S,Zbib H,Stute S,Girault JM,Charara J,Noailles J,Chalon S,Buvat I,Tauber C

    更新日期:2013-10-07 00:00:00

  • The impact of calibration phantom errors on dual-energy digital mammography.

    abstract::Microcalcification is one of the earliest and main indicators of breast cancer. Because dual-energy digital mammography could suppress the contrast between the adipose and glandular tissues of the breast, it is considered a promising technique that will improve the detection of microcalcification. In dual-energy digit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/22/004

    authors: Mou X,Chen X,Sun L,Yu H,Ji Z,Zhang L

    更新日期:2008-11-21 00:00:00

  • Effective dose conversion coefficient for gamma ray exposure from an overhead plume.

    abstract::The external radiation exposure from an overhead plume containing gamma emitting radionuclides can contribute substantial dose to the ground receptor during normal operations as well as accidental release conditions of nuclear facilities. In order to estimate the effective dose conversion coefficients (DCCs) directly,...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2c92

    authors: Dey R,Patni HK,Deo Singh K,Kulkarni MS,Anand S

    更新日期:2019-08-01 00:00:00

  • Elastography--the movement begins.

    abstract::The advent of real-time ultrasound in the 1970s, together with a growing interest in tissue characterization, led to a number of investigators using the nature of tissue motion to distinguish healthy from diseased tissue. Our group at the (then) Ultrasonics Institute demonstrated the use of phase methods for detecting...

    journal_title:Physics in medicine and biology

    pub_type: 历史文章,杂志文章

    doi:10.1088/0031-9155/45/6/301

    authors: Wilson LS,Robinson DE,Dadd MJ

    更新日期:2000-06-01 00:00:00

  • Response, thermal regulatory threshold and thermal breakdown threshold of restrained RF-exposed mice at 905 MHz.

    abstract::The objective of this study was the determination of the thermal regulatory and the thermal breakdown thresholds for in-tube restrained B6C3F1 and NMRI mice exposed to radiofrequency electromagnetic fields at 905 MHz. Different levels of the whole-body averaged specific absorption rate (SAR = 0, 2, 5, 7.2, 10, 12.6 an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/21/017

    authors: Ebert S,Eom SJ,Schuderer J,Apostel U,Tillmann T,Dasenbrock C,Kuster N

    更新日期:2005-11-07 00:00:00