Neutron scattering cross sections and partial kerma values for oxygen, nitrogen and calcium at 18 less than En less than 60 MeV.

Abstract:

:Recent measurements of differential elastic and inelastic neutron scattering from oxygen, nitrogen and calcium at 18 less than En less than 26 MeV are presented and analysed in terms of the optical model. These data, together with earlier measurements of scattering and total cross sections, are used to construct model potentials that may be used to calculate various quantities of interest in neutron dosimetry in an energy region (20-60 MeV) where very few cross section data are available. The heavy-ion-recoil contribution to kerma is obtained directly from the data at each energy. The value of proton inelastic scattering data for validating potential models at high energy is discussed.

journal_name

Phys Med Biol

authors

Islam MS,Finlay RW,Petler JS,Rapaport J,Alarcon R,Wierzbicki J

doi

10.1088/0031-9155/33/3/001

subject

Has Abstract

pub_date

1988-03-01 00:00:00

pages

315-28

issue

3

eissn

0031-9155

issn

1361-6560

journal_volume

33

pub_type

杂志文章
  • Estimation of renal scintigraphy parameters using a linear piecewise-continuous model.

    abstract::Instead of performing a numerical deconvolution, we propose to use a linear piecewise-continuous model of the renal impulse response function for parametric fitting of renal scintigraphy data, to obtain clinically useful renal parameters. The strengths of the present model are its simplicity and speed of computation, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/12/402

    authors: Zhang JL,Zhang L,Koh TS,Shuter B

    更新日期:2003-06-21 00:00:00

  • The inverse problem of a Gaussian convolution and its application to the finite size of the measurement chambers/detectors in photon and proton dosimetry.

    abstract::A Gaussian convolution kernel K is deduced as a Green's function of a Lie operator series. The deconvolution of a Gaussian kernel is developed by the inverse Green's function K(-1). A practical application is the deconvolution of measured profiles Dm(x) of photons and protons with finite detector size to determine the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/6/302

    authors: Ulmer W,Kaissl W

    更新日期:2003-03-21 00:00:00

  • Review on the characteristics of radiation detectors for dosimetry and imaging.

    abstract::The enormous advances in the understanding of human anatomy, physiology and pathology in recent decades have led to ever-improving methods of disease prevention, diagnosis and treatment. Many of these achievements have been enabled, at least in part, by advances in ionizing radiation detectors. Radiology has been tran...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/59/20/R303

    authors: Seco J,Clasie B,Partridge M

    更新日期:2014-10-21 00:00:00

  • Feasibility study of range verification based on proton-induced acoustic signals and recurrent neural network.

    abstract::Range verification in proton therapy is a critical quality assurance task. We studied the feasibility of online range verification based on proton-induced acoustic signals, using a bidirectional long-short-term-memory recurrent neural network and various signal processing techniques. Dose distribution of 1D pencil pro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abaa5e

    authors: Yao S,Hu Z,Zhang X,Lou E,Liang Z,Wang Y,Peng H

    更新日期:2020-11-05 00:00:00

  • Algorithm-enabled exploration of image-quality potential of cone-beam CT in image-guided radiation therapy.

    abstract::Kilo-voltage (KV) cone-beam computed tomography (CBCT) unit mounted onto a linear accelerator treatment system, often referred to as on-board imager (OBI), plays an increasingly important role in image-guided radiation therapy. While the FDK algorithm is currently used for reconstructing images from clinical OBI data,...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/12/4601

    authors: Han X,Pearson E,Pelizzari C,Al-Hallaq H,Sidky EY,Bian J,Pan X

    更新日期:2015-06-21 00:00:00

  • 4D cone beam CT-based dose assessment for SBRT lung cancer treatment.

    abstract::The purpose of this research is to develop a 4DCBCT-based dose assessment method for calculating actual delivered dose for patients with significant respiratory motion or anatomical changes during the course of SBRT. To address the limitation of 4DCT-based dose assessment, we propose to calculate the delivered dose us...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/2/554

    authors: Cai W,Dhou S,Cifter F,Myronakis M,Hurwitz MH,Williams CL,Berbeco RI,Seco J,Lewis JH

    更新日期:2016-01-21 00:00:00

  • Evolutionary pruning of transfer learned deep convolutional neural network for breast cancer diagnosis in digital breast tomosynthesis.

    abstract::Deep learning models are highly parameterized, resulting in difficulty in inference and transfer learning for image recognition tasks. In this work, we propose a layered pathway evolution method to compress a deep convolutional neural network (DCNN) for classification of masses in digital breast tomosynthesis (DBT). T...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aabb5b

    authors: Samala RK,Chan HP,Hadjiiski LM,Helvie MA,Richter C,Cha K

    更新日期:2018-05-01 00:00:00

  • Computer-aided diagnosis of lung cancer: the effect of training data sets on classification accuracy of lung nodules.

    abstract::This study aims to develop a computer-aided diagnosis (CADx) scheme for classification between malignant and benign lung nodules, and also assess whether CADx performance changes in detecting nodules associated with early and advanced stage lung cancer. The study involves 243 biopsy-confirmed pulmonary nodules. Among ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa610

    authors: Gong J,Liu JY,Sun XW,Zheng B,Nie SD

    更新日期:2018-02-05 00:00:00

  • 1D dynamic beam modulation: methods to counteract inertia effects.

    abstract::Dynamic modulation can be affected by inaccuracies when the required acceleration is larger than the highest allowed by the mechanical characteristics of the whole apparatus. In this study, inertia effects have been investigated with regard to the single absorber 1D modulation, analysing primarily how the acceleration...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/11/401

    authors: Corletto D,Broggi S,Fiorino C,Mangili P,Calandrino R,Lev A,Gennari D,Rudello F

    更新日期:1999-11-01 00:00:00

  • Is it necessary to plan with safety margins for actively scanned proton therapy?

    abstract::In radiation therapy, a plan is robust if the calculated and the delivered dose are in agreement, even in the case of different uncertainties. The current practice is to use safety margins, expanding the clinical target volume sufficiently enough to account for treatment uncertainties. This, however, might not be idea...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/14/011

    authors: Albertini F,Hug EB,Lomax AJ

    更新日期:2011-07-21 00:00:00

  • Monte Carlo optimization of a microbeam collimator design for use on the small animal radiation research platform (SARRP).

    abstract::Microbeam radiation therapy (MRT) is a pre-clinical, spatially-fractionated treatment modality noted for its ability to achieve a large differential response between normal and tumoral tissues. In the present study, TOPAS Monte Carlo (MC) simulations were used to optimize the design of a compact, affordable multi-slit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad7e2

    authors: Esplen NM,Chergui L,Johnstone CD,Bazalova-Carter M

    更新日期:2018-08-29 00:00:00

  • Identifying critical human subpopulations by age groups: radioactivity and the lung.

    abstract::This work studies the effect of age on lung dose commitments arising from the inhalation of an atmosphere containing radionuclides of varying half-lives and physical sizes. This dependence is significant in many cases, approaching a ratio of 2 in several instances when the maximum dose at a given age is compared with ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/27/4/005

    authors: Crawford DJ

    更新日期:1982-04-01 00:00:00

  • A model for the accurate computation of the lateral scattering of protons in water.

    abstract::A pencil beam model for the calculation of the lateral scattering in water of protons for any therapeutic energy and depth is presented. It is based on the full Molière theory, taking into account the energy loss and the effects of mixtures and compounds. Concerning the electromagnetic part, the model has no free para...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/4/N102

    authors: Bellinzona EV,Ciocca M,Embriaco A,Ferrari A,Fontana A,Mairani A,Parodi K,Rotondi A,Sala P,Tessonnier T

    更新日期:2016-02-21 00:00:00

  • Use of an amorphous silicon electronic portal imaging device for multileaf collimator quality control and calibration.

    abstract::Multileaf collimator (MLC) calibration and quality control is a time-consuming procedure typically involving the processing, scanning and analysis of films to measure leaf and collimator positions. Faster and more reliable calibration procedures are required for these tasks, especially with the introduction of intensi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/7/003

    authors: Baker SJ,Budgell GJ,MacKay RI

    更新日期:2005-04-07 00:00:00

  • Response, thermal regulatory threshold and thermal breakdown threshold of restrained RF-exposed mice at 905 MHz.

    abstract::The objective of this study was the determination of the thermal regulatory and the thermal breakdown thresholds for in-tube restrained B6C3F1 and NMRI mice exposed to radiofrequency electromagnetic fields at 905 MHz. Different levels of the whole-body averaged specific absorption rate (SAR = 0, 2, 5, 7.2, 10, 12.6 an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/21/017

    authors: Ebert S,Eom SJ,Schuderer J,Apostel U,Tillmann T,Dasenbrock C,Kuster N

    更新日期:2005-11-07 00:00:00

  • Applying a new maximum local asymmetry feature analysis method to improve near-term breast cancer risk prediction.

    abstract::Quantitative assessment of mammographic asymmetry has been investigated for breast cancer risk prediction. A new asymmetry feature extraction method was proposed in this study to enhance the risk prediction accuracy of near-term breast cancer. Breast areas in each pair of bilateral mammographic images were divided int...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aae452

    authors: Yan S,Zhang L,Song C

    更新日期:2018-10-17 00:00:00

  • The unique determination of the primary current by MEG and EEG.

    abstract::In this paper, we use a more realistic head model with ovoid geometry for approximation of a human head. By inverting the Geselowitz equation, some analytic results on the inverse MEG problem are presented in homogenous ovoid geometry. On one hand, some information about the components of primary current is shown by t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/21/012

    authors: Peng L,Cheng J,Jin L

    更新日期:2006-11-07 00:00:00

  • The exponential edge-gradient effect in x-ray computed tomography.

    abstract::The exponential edge-gradient effect must arise in any x-ray transmission CT scanner whenever long sharp edges of high contrast are encountered. The effect is non-linear and is due to the interaction of the exponential law of x-ray attenuation and the finite width of the scanning beam in the x-y plane. The error induc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/26/3/010

    authors: Joseph PM,Spital RD

    更新日期:1981-05-01 00:00:00

  • A phantom for the testing and calibration of near infra-red spectrometers.

    abstract::This note describes a simple phantom which can be used to check the long term stability and accuracy of relative attenuation measurements made by near infra-red (NIR) spectrometers. The phantom has been calibrated, and the results of the calibration are shown to agree with theoretical predictions of the relative atten...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/9/015

    authors: Firbank M,Delpy DT

    更新日期:1994-09-01 00:00:00

  • Development and validation of a BEAMnrc component module for accurate Monte Carlo modelling of the Varian dynamic Millennium multileaf collimator.

    abstract::A new component module (CM), designated DYNVMLC, was developed to fully model the geometry of the Varian Millennium 120 leaf collimator using the BEAMnrc Monte Carlo code. The model includes details such as the leaf driving screw hole, support railing groove and leaf tips. Further modifications also allow sampling of ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/24/004

    authors: Heath E,Seuntjens J

    更新日期:2003-12-21 00:00:00

  • Mechanical analysis of an axially symmetric cylindrical phantom with a spherical heterogeneity for MR elastography.

    abstract::Cylindrical homogenous phantoms for magnetic resonance (MR) elastography in biomedical research provide one way to validate an imaging systems performance, but the simplified geometry and boundary conditions can cloak complexity arising at tissue interfaces. In an effort to develop a more realistic gel tissue phantom ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/18/6821

    authors: Schwartz BL,Yin Z,Magin RL

    更新日期:2016-09-21 00:00:00

  • The role of trapped bubbles in kidney stone detection with the color Doppler ultrasound twinkling artifact.

    abstract::The color Doppler ultrasound twinkling artifact, which highlights kidney stones with rapidly changing color, has the potential to improve stone detection; however, its inconsistent appearance has limited its clinical utility. Recently, it was proposed stable crevice bubbles on the kidney stone surface cause twinkling;...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa9a2f

    authors: Simon JC,Sapozhnikov OA,Kreider W,Breshock M,Williams JC,Bailey MR

    更新日期:2018-01-09 00:00:00

  • Development and comparison of computer methods for organ motion correction in scintigraphy.

    abstract::The process of organ motion correction in scintigraphy is analysed in the frequency domain. The sequence of the chi- and gamma- coordinates registered during scintigraphic recording is converted to a frequency spectrum by a discrete Fourier transform. In the frequency domain motion correction is performed by linear fi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/20/3/010

    authors: Schmidlin P

    更新日期:1975-05-01 00:00:00

  • Measurement of image contrast using diffraction enhanced imaging.

    abstract::Refraction contrast of simple objects obtained using diffraction enhanced imaging (DEI) was studied and compared to conventional radiographic contrast. Lucite cylinders and nylon wires were imaged using monochromatic synchrotron radiation at the National Synchrotron Light Source (http://nslsweb. nsls.bnl.gov/nsls/Defa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/3/304

    authors: Kiss MZ,Sayers DE,Zhong Z

    更新日期:2003-02-07 00:00:00

  • Energy and spatial distribution of multiple order Compton scatter in SPECT: a Monte Carlo investigation.

    abstract::Energy and spatial projection distributions were simulated for gamma camera imaging of multiple order Compton scattered photons. SPECT imaging of a line source of radioactivity located in a water filled cylindrical phantom was modelled using Monte Carlo techniques. Photon trajectories were followed from emission to de...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/10/005

    authors: Floyd CE,Jaszczak RJ,Harris CC,Coleman RE

    更新日期:1984-10-01 00:00:00

  • Magnetorelaxometric quantification of magnetic nanoparticles in an artery model after ex vivo magnetic drug targeting.

    abstract::In magnetic drug targeting a chemotherapeutic agent is bound to coated magnetic nanoparticles, which are administered to the blood vessel system and subsequently focused by an external applied magnetic field. The optimization of intra-arterial magnetic drug targeting (MDT) requires detailed knowledge about the biodist...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/18/N03

    authors: Richter H,Wiekhorst F,Schwarz K,Lyer S,Tietze R,Alexiou Ch,Trahms L

    更新日期:2009-09-21 00:00:00

  • An age-dependent series of eye models for radiation dosimetry.

    abstract::Several studies have been appeared, up to now, that indicate the effect of accurate simulation on dose received by different substructures of the eye, irradiated by external beams of short-range radiation such as electron. Different representations of the eye have consequently been introduced. Their accuracies depend ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2059

    authors: Vejdani-Noghreiyan A,Ebrahimi-Khankook A

    更新日期:2019-07-02 00:00:00

  • A Monte Carlo study of the variation of electron fluence in water from a 6 MV photon beam outside of the field.

    abstract::Existing studies have suggested some debate on whether the quality of radiation that delivers dose outside of the primary field of a radiotherapy photon beam can be considered the same as that inside the primary field. We used a Monte Carlo approach to simulate the electron fluence differential in energy inside a wate...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/12/015

    authors: Kirkby C,Field C,MacKenzie M,Syme A,Fallone BG

    更新日期:2007-06-21 00:00:00

  • Minimizing the magnetic field effect in MR-linac specific QA-tests: the use of electron dense materials.

    abstract::To address the quality assurance (QA) of a MR-linac which is an MRI combined with a linear accelerator (linac), the traditional linac QA-tests need to be redesigned, since the presence of the static magnetic field in the MR-linac alters the electron trajectory. The latter causes the asymmetry in the dose kernel which ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/3/N50

    authors: van Zijp HM,van Asselen B,Wolthaus JW,Kok JM,de Vries JH,Ishakoglu K,Beld E,Lagendijk JJ,Raaymakers BW

    更新日期:2016-02-07 00:00:00

  • Plane wave versus focused transmissions for contrast enhanced ultrasound imaging: the role of parameter settings and the effects of flow rate on contrast measurements.

    abstract::Contrast enhanced ultrasound (CEUS) and dynamic contrast enhanced ultrasound (DCE-US) can be used to provide information about the vasculature aiding diagnosis and monitoring of a number of pathologies including cancer. In the development of a CEUS imaging system, there are many choices to be made, such as whether to ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab13f2

    authors: Moghimirad E,Bamber J,Harris E

    更新日期:2019-04-23 00:00:00