Correlation between dosimetric effect and intrafraction motion during prostate treatments delivered with helical tomotherapy.

Abstract:

:The dosimetric impact of intrafraction prostate motion was investigated for helical tomotherapy treatments. Measured motion tracks were used to calculate the dosimetric impact on delivered target dose distributions. A dynamic dose calculation engine was developed to facilitate this evaluation. It was found that the D95% (minimum dose to 95% of the volume) changes in the prostate were well correlated with D95% changes in the PTV. This means that the dosimetric impact of intrafraction motion is not restricted to the periphery of the target. The amount of motion was not well correlated with the dosimetric impact (measured in target D95% changes) of motion. The relationship between motion and its dosimetric impact is complex and depends on the timing and direction of the movement. These findings have implications for motion management techniques. It appears that the use of target margins is not an effective strategy to protect the prostate from the effects of observed intrafraction motion. The complex relationship between motion and its dosimetric effect renders simple threshold-based intervention schemes inefficient. Monitoring of actual prostate motion would allow the documentation of the dosimetric impact and implementation of corrective action if needed. However, when motion management techniques are evaluated, it should be kept in mind that the dosimetric impact of observed prostate motion is small for the majority of fractions.

journal_name

Phys Med Biol

authors

Langen KM,Lu W,Ngwa W,Willoughby TR,Chauhan B,Meeks SL,Kupelian PA,Olivera G

doi

10.1088/0031-9155/53/24/005

subject

Has Abstract

pub_date

2008-12-21 00:00:00

pages

7073-86

issue

24

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(08)87108-4

journal_volume

53

pub_type

杂志文章
  • Dosimetry comparison and characterisation of an Al K ultrasoft x-ray beam from an MRC cold-cathode source.

    abstract::Ultrasoft x-rays of 0.3-5 keV have provided a unique tool for the investigation of intracellular mechanisms of radiation action in biological organisms, including mammalian cells. However, their use presents unique practical problems in dosimetry and experimental design. Detailed interpretation of the biological resul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/10/002

    authors: Hoshi M,Goodhead DT,Brenner DJ,Bance DA,Chmielewski JJ,Paciotti MA,Bradbury JN

    更新日期:1985-10-01 00:00:00

  • Fully three-dimensional positron emission tomography.

    abstract::Fully three-dimensional positron emission tomography is considered and a reconstruction algorithm derived. The reconstruction problem is formulated mathematically as a three-dimensional convolution integral of a point spread function with an unknown positron activity distribution and is solved by Fourier transform met...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/1/010

    authors: Colsher JG

    更新日期:1980-01-01 00:00:00

  • The quality of ionising radiations emitted by radionuclides incorporated into mammalian cells.

    abstract::Radionuclides which decay by electron capture accompanied by Auger electron cascades, or by beta emission are thought to be excessively damaging when incorporated into the molecular structure of mammalian cell nuclei and thereby pose a radiation hazard which is not assessable by conventional dosimetry. Survival data, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/7/003

    authors: Younis AR,Watt DE

    更新日期:1989-07-01 00:00:00

  • Sensitivity study of the microdosimetric kinetic model parameters for carbon ion radiotherapy.

    abstract::In carbon ion therapy treatment planning, the relative biological effectiveness (RBE) is accounted for by optimization of the RBE-weighted dose (biological dose). The RBE calculation methods currently applied clinically in carbon ion therapy are derived from the microdosimetric kinetic model (MKM) in Japan and the loc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aae8b4

    authors: Dahle TJ,Magro G,Ytre-Hauge KS,Stokkevåg CH,Choi K,Mairani A

    更新日期:2018-11-12 00:00:00

  • Scan-rescan and intra-observer variability of magnetic resonance imaging of carotid atherosclerosis at 1.5 T and 3.0 T.

    abstract::Carotid atherosclerosis measurements for eight subjects at baseline and 14 +/- 2 days later were examined using 1.5 T and 3.0 T magnetic resonance imaging (MRI). A single observer blinded to field strength, subject and timepoint manually segmented carotid artery wall and lumen boundaries in randomized images in five m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/23/011

    authors: Vidal A,Bureau Y,Wade T,Spence JD,Rutt BK,Fenster A,Parraga G

    更新日期:2008-12-07 00:00:00

  • A method of improving the spatial resolution of treatments that involve a multileaf collimator.

    abstract::In this paper we present a novel method of reducing the dosimetric effects of the finite leaf width of a multileaf collimator (MLC) in conformal and intensity modulated radiotherapy (IMRT). This is achieved by decomposing the required high-resolution fluence distribution into two orthogonal components, which are deliv...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/3/304

    authors: Evans PM,Partridge M

    更新日期:2000-03-01 00:00:00

  • A study of potential numerical pitfalls in GPU-based Monte Carlo dose calculation.

    abstract::The purpose of this study was to evaluate the impact of numerical errors caused by the floating point representation of real numbers in a GPU-based Monte Carlo code used for dose calculation in radiation oncology, and to identify situations where this type of error arises. The program used as a benchmark was bGPUMCD. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/13/5007

    authors: Magnoux V,Ozell B,Bonenfant É,Després P

    更新日期:2015-07-07 00:00:00

  • Methods for the inclusion of shallow marrow and adipose tissue in pathlength-based skeletal dosimetry.

    abstract::Distributions of linear pathlength measurements have been utilized in skeletal dosimetry of internally emitted short-range particles for over 30 years. This work reviews the methods for coupling these distributions to range-energy data. A revised methodology is presented for handling the insertion of the additional do...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/9/004

    authors: Jokisch DW,Rajon DA,Patton PW,Bolch WE

    更新日期:2011-05-07 00:00:00

  • A task-based quality control metric for digital mammography.

    abstract::A reader study was conducted to tune the parameters of an observer model used to predict the detectability index (dʹ ) of test objects as a task-based quality control (QC) metric for digital mammography. A simple test phantom was imaged to measure the model parameters, namely, noise power spectrum,modulation transfer ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/21/6621

    authors: Bloomquist AK,Mainprize JG,Mawdsley GE,Yaffe MJ

    更新日期:2014-11-07 00:00:00

  • Radioluminescence in biomedicine: physics, applications, and models.

    abstract::The electromagnetic spectrum contains different frequency bands useful for medical imaging and therapy. Short wavelengths (ionizing radiation) are commonly used for radiological and radionuclide imaging and for cancer radiation therapy. Intermediate wavelengths (optical radiation) are useful for more localized imaging...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/1361-6560/aaf4de

    authors: Klein JS,Sun C,Pratx G

    更新日期:2019-02-06 00:00:00

  • Image-based point spread function implementation in a fully 3D OSEM reconstruction algorithm for PET.

    abstract::The interest in positron emission tomography (PET) and particularly in hybrid integrated PET/CT systems has significantly increased in the last few years due to the improved quality of the obtained images. Nevertheless, one of the most important limits of the PET imaging technique is still its poor spatial resolution ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/14/012

    authors: Rapisarda E,Bettinardi V,Thielemans K,Gilardi MC

    更新日期:2010-07-21 00:00:00

  • Accounting for range uncertainties in the optimization of intensity modulated proton therapy.

    abstract::Treatment plans optimized for intensity modulated proton therapy (IMPT) may be sensitive to range variations. The dose distribution may deteriorate substantially when the actual range of a pencil beam does not match the assumed range. We present two treatment planning concepts for IMPT which incorporate range uncertai...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/10/009

    authors: Unkelbach J,Chan TC,Bortfeld T

    更新日期:2007-05-21 00:00:00

  • PDE-constrained LDDMM via geodesic shooting and inexact Gauss-Newton-Krylov optimization using the incremental adjoint Jacobi equations.

    abstract::The class of non-rigid registration methods proposed in the framework of PDE-constrained large deformation diffeomorphic metric mapping is a particularly interesting family of physically meaningful diffeomorphic registration methods. Inexact Gauss-Newton-Krylov optimization has shown an excellent numerical accuracy an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaf598

    authors: Hernandez M

    更新日期:2019-01-07 00:00:00

  • Diaphragm correction factors for free-air chamber standards for air kerma in x-rays.

    abstract::At present, only a correction factor for photon transmission, k(l), is systematically applied for the entrance diaphragm of free-air chamber standards for air kerma. In the present work, the Monte Carlo code PENELOPE is used to re-evaluate k(l) for the BIPM standards and new correction factors are calculated for photo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/9/009

    authors: Burns DT,Kessler C

    更新日期:2009-05-07 00:00:00

  • The measurement of silicon in a lung phantom--a comparison of two nuclear reactions for in vivo activation analysis.

    abstract::The amount of silica in the human lung may be estimated by measurement of silicon using in vivo neutron activation analysis. A pulsed, fast neutron beam, produced with a 2 MV Van de Graaff generator using the 2H + 2H reaction, was used to irradiate a Si-doped chest phantom in order to determine minimum detection limit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/38/6/004

    authors: Kacperek A,Ryde SJ,Evans CJ,Dutton J,Morgan WD,Sivyer A

    更新日期:1993-06-01 00:00:00

  • Effects of particle diameter and magnetocrystalline anisotropy on magnetic relaxation and magnetic particle imaging performance of magnetic nanoparticles.

    abstract::The dynamic magnetization of immobilized spherical single-domain magnetic nanoparticles (MNPs) with uniaxial or cubic magnetocrystalline anisotropy was studied computationally by executing simulations based on the Landau-Lifshitz-Gilbert (LLG) equation. For situations when a static magnetic field was suddenly applied ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab5b83

    authors: Zhao Z,Garraud N,Arnold DP,Rinaldi C

    更新日期:2020-01-17 00:00:00

  • Spectrum reconstruction from dose measurements as a linear inverse problem.

    abstract::There are three ways to determine the spectrum of a clinical photon beam: direct measurement, modelling the source and reconstruction from ion-chamber measurements. We focus on reconstruction because the necessary equipment is readily available and it provides independent confirmation of source models for a given mach...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/22/005

    authors: Armbruster B,Hamilton RJ,Kuehl AK

    更新日期:2004-11-21 00:00:00

  • Inverse planning for functional image-guided intensity-modulated radiation therapy.

    abstract::Radiation therapy is an image-guided process whose success critically depends on the imaging modality used for treatment planning and the level of integration of the available imaging information. In this work, we establish a dose optimization framework for incorporating metabolic information from functional imaging m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/20/301

    authors: Xing L,Cotrutz C,Hunjan S,Boyer AL,Adalsteinsson E,Spielman D

    更新日期:2002-10-21 00:00:00

  • The ArcCHECK diode array for dosimetric verification of HybridArc.

    abstract::The aim of this work is to evaluate dosimetric accuracy of a new treatment modality, HybridArc, in iPlan RT Dose 4.5 (BrainLAB, Feldkirchen, Germany) using a four-dimensional diode array (ArcCHECK, Sun Nuclear Corporation, Melbourne, USA). HybridArc is able to enhance dynamic conformal arcs with inversely planned elem...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/16/021

    authors: Petoukhova AL,van Egmond J,Eenink MG,Wiggenraad RG,van Santvoort JP

    更新日期:2011-08-21 00:00:00

  • Dielectric studies on the reaction of the intracellular matter of fish red blood cells to detergent toxicity.

    abstract::Results from dielectric studies on the freshwater fish Cyprinus carpio exposed to a sublethal concentration of sodium alkyl benzene sulphonate were compared with those from untreated control fish; recovery from the test solution was also checked. The influence of the anionic detergent on the intracellular matter of fi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/5/005

    authors: Bielinska I,Terlecki J

    更新日期:1984-05-01 00:00:00

  • Applicators for generating ultrasound-induced hyperthermia in neoplastic tumours and for use in ultrasound physiotherapy.

    abstract::Ultrasound in the low megahertz frequency range is used by physiotherapists to treat a variety of conditions. The treatments reduce swelling, reduce pain and increase movement at joints. Ultrasound is now also beginning to be used to treat malignant tumours. The tumours are heated to temperatures between 42 degrees an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/11/019

    authors: Quan KM,Shiran M,Watmough DJ

    更新日期:1989-11-01 00:00:00

  • Factors affecting in vivo measurement precision and accuracy of 109Cd K x-ray fluorescence measurements.

    abstract::109Cd K x-ray fluorescence (XRF) measurement systems from two research centres were used to measure tibia lead content in a population (n = 530) of young adults. The group mean bone lead contents (+/-SEM) determined by McMaster University (n = 214) and the University of Maryland (n = 316) were 2.80 +/- 0.51 and 2.33 +...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/9/313

    authors: McNeill FE,Stokes L,Chettle DR,Kaye WE

    更新日期:1999-09-01 00:00:00

  • A multiresolution image based approach for correction of partial volume effects in emission tomography.

    abstract::Partial volume effects (PVEs) are consequences of the limited spatial resolution in emission tomography. They lead to a loss of signal in tissues of size similar to the point spread function and induce activity spillover between regions. Although PVE can be corrected for by using algorithms that provide the correct ra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/7/016

    authors: Boussion N,Hatt M,Lamare F,Bizais Y,Turzo A,Cheze-Le Rest C,Visvikis D

    更新日期:2006-04-07 00:00:00

  • Modelling of temperature and perfusion during scalp cooling.

    abstract::Hair loss is a feared side effect of chemotherapy treatment. It may be prevented by cooling the scalp during administration of cytostatics. The supposed mechanism is that by cooling the scalp, both temperature and perfusion are diminished, affecting drug supply and drug uptake in the hair follicle. However, the effect...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/17/010

    authors: Janssen FE,Van Leeuwen GM,Van Steenhoven AA

    更新日期:2005-09-07 00:00:00

  • Numerical calculation of energy deposition by broad high-energy electron beams.

    abstract::The feasibility is demonstrated of a numerical method to calculate dose deposition by broad high-energy electron beams in homogeneous matter or in heterogeneous matter in which the heterogeneities are arranged in slabs perpendicular to the beam axis. The method is based only on the basic physical interaction processes...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/10/003

    authors: Huizenga H,Storchi PR

    更新日期:1989-10-01 00:00:00

  • A temperature-based feedback control system for electromagnetic phased-array hyperthermia: theory and simulation.

    abstract::A hybrid proportional-integral-in-time and cost-minimizing-in-space feedback control system for electromagnetic, deep regional hyperthermia is proposed. The unique features of this controller are that (1) it uses temperature, not specific absorption rate, as the criterion for selecting the relative phases and amplitud...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/5/306

    authors: Kowalski ME,Jin JM

    更新日期:2003-03-07 00:00:00

  • Use of forward projection to correct patient motion during SPECT imaging.

    abstract::We have developed an iterative method to correct axial and tangential patient motion occurring during tomographic acquisition. The method uses axial images reconstructed from the uncorrected projection images, which are then forward projected to form a basis for registering the original planar images and, in the proce...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/1/011

    authors: Lee KJ,Barber DC

    更新日期:1998-01-01 00:00:00

  • Specific absorbed fractions for a revised series of the UF/NCI pediatric reference phantoms: internal photon sources.

    abstract::Assessment of radiation absorbed dose to internal organs of the body from the intake of radionuclides or, in the medical setting through the injection of radiopharmaceuticals, is generally performed based upon reference biokinetic models or patient imaging data, respectively. Biokinetic models estimate the time course...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abc708

    authors: Schwarz BC,Godwin WJ,Wayson MB,Dewji SA,Jokisch DW,Lee C,Bolch WE

    更新日期:2020-11-03 00:00:00

  • A modified lead attenuation method to determine the fast neutron sensitivity kU of a photon dosemeter.

    abstract::Various lead attenuation techniques to determine the fast neutron sensitivity kU of a photon dosemeter are reviewed and a modified method is proposed to determine the kU value of a commercially available Geiger--Müller detector. The dependence on the 'effective' photon energy of the gamma-component of the mixed n--gam...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/24/4/005

    authors: Hough JH

    更新日期:1979-07-01 00:00:00

  • Real-time tracking of tumor motions and deformations along the leaf travel direction with the aid of a synchronized dynamic MLC leaf sequencer.

    abstract::Advanced radiotherapeutical techniques like intensity-modulated radiation therapy (IMRT) are based on an accurate knowledge of the location of the radiation target. An accurate dose delivery, therefore, requires a method to account for the inter- and intrafractional target motion and the target deformation occurring d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/22/N01

    authors: Tacke M,Nill S,Oelfke U

    更新日期:2007-11-21 00:00:00