A method of improving the spatial resolution of treatments that involve a multileaf collimator.

Abstract:

:In this paper we present a novel method of reducing the dosimetric effects of the finite leaf width of a multileaf collimator (MLC) in conformal and intensity modulated radiotherapy (IMRT). This is achieved by decomposing the required high-resolution fluence distribution into two orthogonal components, which are delivered with two leaf sweeps with head-twists differing by 90 degrees. Before the decomposition stage, a filter is applied to the required beam to force it to have a constant gradient in the two delivery directions. The component deliveries were found to be very spiky in nature, resulting in very inefficient delivery with the scanning leaves of our MLC. This method was evaluated using film dosimetry of four idealized beams: a 45 degree edge, a circle, a hemispherical intensity modulated beam (IMB) and a sine-like IMB. The measurements showed that this method had significantly reduced the effects of the 1 cm leaf width of our MLC at the 50% isodose level, but there was significant overdosage at the edge of the field and immediately inside the held edge. This method shows promise but further work is required before it may find clinical utility.

journal_name

Phys Med Biol

authors

Evans PM,Partridge M

doi

10.1088/0031-9155/45/3/304

subject

Has Abstract

pub_date

2000-03-01 00:00:00

pages

609-22

issue

3

eissn

0031-9155

issn

1361-6560

journal_volume

45

pub_type

杂志文章
  • A novel microbubble construct for intracardiac or intravascular MR manometry: a theoretical study.

    abstract::It has been demonstrated that gas-filled microbubble contrast agents, based on their volume changes, can serve as pressure probes in an MR field. It was recently reported that such an MR-based pressure measurement with microbubbles at 1.5 T must make use of microbubbles that have a volumetric magnetic susceptibility d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/20/001

    authors: Dharmakumar R,Plewes DB,Wright GA

    更新日期:2005-10-21 00:00:00

  • Local hydrogen clearance as a method for the measurement of capillary blood flow.

    abstract::A hydrogen clearance technique for the measurement of capillary blood flow in skeletal muscle (both resting and working) and the beating heart in experimental animals is described. Various methods for introducing the hydrogen into the region of measurement are compared, together with the appropriate methods for evalua...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/10/005

    authors: Harrison DK,Kessler M

    更新日期:1989-10-01 00:00:00

  • Laboratory prototype for experimental validation of MR-guided radiofrequency head and neck hyperthermia.

    abstract::Clinical studies have established a strong benefit from adjuvant mild hyperthermia (HT) to radio- and chemotherapy for many tumor sites, including the head and neck (H&N). The recently developed HYPERcollar allows the application of local radiofrequency HT to tumors in the entire H&N. Treatment quality is optimized us...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/9/2139

    authors: Paulides MM,Bakker JF,Hofstetter LW,Numan WC,Pellicer R,Fiveland EW,Tarasek M,Houston GC,van Rhoon GC,Yeo DT,Kotek G

    更新日期:2014-05-07 00:00:00

  • The integration of DVH-based planning aspects into a convex intensity modulated radiation therapy optimization framework.

    abstract::The formulation of intensity modulated radiation therapy (IMRT) planning aspects frequently uses the dose-volume histogram (DVH), whereas plan computations often happen in the more desirable convex IMRT optimization framework. Inspired by a recent publication of Zinchenko et al (2008 Phys. Med. Biol. 53 3231-50), this...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/12/N02

    authors: Kratt K,Scherrer A

    更新日期:2009-06-21 00:00:00

  • Wavelet-packet-based texture analysis for differentiation between benign and malignant liver tumours in ultrasound images.

    abstract::The purpose of this study was to apply a novel method of multiscale echo texture analysis for distinguishing benign (hemangiomas) from malignant (hepatocellular carcinomas (HCCs) and metastases) focal liver lesions in B-mode ultrasound images. In this method, regions of interest (ROIs) extracted from within the lesion...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/22/008

    authors: Yoshida H,Casalino DD,Keserci B,Coskun A,Ozturk O,Savranlar A

    更新日期:2003-11-21 00:00:00

  • Full-field speckle interferometry for non-contact photoacoustic tomography.

    abstract::A full-field speckle interferometry method for non-contact and prospectively high speed Photoacoustic Tomography is introduced and evaluated as proof of concept. Thermoelastic pressure induced changes of the objects topography are acquired in a repetitive mode without any physical contact to the object. In order to ob...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/10/4045

    authors: Horstmann J,Spahr H,Buj C,Münter M,Brinkmann R

    更新日期:2015-05-21 00:00:00

  • Comparison of build-up dose between Elekta and Varian linear accelerators for high-energy photon beams using radiochromic film and clinical implications for IMRT head and neck treatments.

    abstract::Skin toxicity has been reported for IMRT of head and neck cancer. The purpose of this study was to investigate the dose in the build-up region delivered by a 6 MV treatment plan for which important skin toxicity was observed. We also investigated if the different designs of the treatment head of an Elekta and a Varian...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/3/002

    authors: Paelinck L,De Wagter C,Van Esch A,Duthoy W,Depuydt T,De Neve W

    更新日期:2005-02-07 00:00:00

  • Coronary CT angiography (cCTA): automated registration of coronary arterial trees from multiple phases.

    abstract::Coronary computed tomography angiography (cCTA) is a commonly used imaging modality for the evaluation of coronary artery disease. cCTA is generally reconstructed in multiple cardiac phases because different coronary arteries may be better visualized in some phases than in others due to the periodic cardiac motion. We...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/16/4661

    authors: Hadjiiski L,Zhou C,Chan HP,Chughtai A,Agarwal P,Kuriakose J,Kazerooni E,Wei J,Patel S

    更新日期:2014-08-21 00:00:00

  • Adaptive anisotropic diffusion filtering of Monte Carlo dose distributions.

    abstract::The Monte Carlo method is the most accurate method for radiotherapy dose calculations, if used correctly. However, any Monte Carlo dose calculation is burdened with statistical noise. In this paper, denoising of Monte Carlo dose distributions with a three-dimensional adaptive anisotropic diffusion method was investiga...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/17/303

    authors: Miao B,Jeraj R,Bao S,Mackie TR

    更新日期:2003-09-07 00:00:00

  • Improved precision of syndesmophyte measurement for the evaluation of ankylosing spondylitis using CT: a phantom and patient study.

    abstract::Ankylosing spondylitis is a disease characterized by abnormal bone formation (syndesmophyte) at the margins of inter-vertebral disc spaces. Syndesmophyte growth is currently typically monitored by the visual inspection of radiographs. The limitations inherent to the modality (2D projection of a 3D object) and rater (q...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/14/4683

    authors: Tan S,Yao J,Yao L,Ward MM

    更新日期:2012-07-21 00:00:00

  • Counting losses in multidetector radiation counters.

    abstract::We examined the reasons for the reduction in response of a multidetector radiation counting system when operated at high count-rates and established a convenient method of correction which is accurate to within +/- 1% up to 0-6 X 10(5) counts per second. In its application the method uses the observed count-rates from...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/21/1/009

    authors: Oxby CB,Oldroyd B,Appleby DB

    更新日期:1976-01-01 00:00:00

  • Pulsed focused ultrasound lowers interstitial fluid pressure and increases nanoparticle delivery and penetration in head and neck squamous cell carcinoma xenograft tumors.

    abstract::Nanocarriers offer a promising approach to significantly improve therapeutic delivery to solid tumors as well as limit the side effects associated with anti-cancer agents. However, their relatively large size can negatively affect their ability to efficiently penetrate into more interior tumor regions, ultimately redu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9705

    authors: Mohammadabadi A,Huynh RN,Wadajkar AS,Lapidus RG,Kim AJ,Raub CB,Frenkel V

    更新日期:2020-06-22 00:00:00

  • Physical characteristics of the ECAT EXACT3D positron tomograph.

    abstract::The 'EXACT3D' positron tomograph, which is now in routine clinical research use, was developed with the aim of achieving unprecedented sensitivity, high spatial and temporal resolution and simplicity of design using proven detector technology. It consists of six rings of standard detector blocks (CTI/Siemens EXACT HR+...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/9/313

    authors: Spinks TJ,Jones T,Bloomfield PM,Bailey DL,Miller M,Hogg D,Jones WF,Vaigneur K,Reed J,Young J,Newport D,Moyers C,Casey ME,Nutt R

    更新日期:2000-09-01 00:00:00

  • A Monte Carlo evaluation of RapidArc dose calculations for oropharynx radiotherapy.

    abstract::RapidArc, recently released by Varian Medical Systems, is a novel extension of IMRT in which an optimized 3D dose distribution may be delivered in a single gantry rotation of 360 degrees or less. The purpose of this study was to investigate the accuracy of the analytical anisotropic algorithm (AAA), the sole algorithm...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/24/011

    authors: Gagne IM,Ansbacher W,Zavgorodni S,Popescu C,Beckham WA

    更新日期:2008-12-21 00:00:00

  • Design, construction and use of a large-sample field-cycled PEDRI imager.

    abstract::The design, construction and use of a large-scale field-cycled proton-electron double-resonance imaging (FC-PEDRI) imager is described. The imager is based on a whole-body sized, vertical field, 59 mT permanent magnet. Field cycling is accomplished by the field compensation method, and uses a secondary, resistive magn...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/7/008

    authors: Lurie DJ,Foster MA,Yeung D,Hutchison JM

    更新日期:1998-07-01 00:00:00

  • Three-dimensional optical tomography of the premature infant brain.

    abstract::For the first time, three-dimensional images of the newborn infant brain have been generated using measurements of transmitted light. A 32-channel time-resolved imaging system was employed, and data were acquired using custom-made helmets which couple source fibres and detector bundles to the infant head. Images have ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/23/303

    authors: Hebden JC,Gibson A,Yusof RM,Everdell N,Hillman EM,Delpy DT,Arridge SR,Austin T,Meek JH,Wyatt JS

    更新日期:2002-12-07 00:00:00

  • Motion correction of respiratory-gated PET images using deep learning based image registration framework.

    abstract::Artifacts caused by patient breathing and movement during PET data acquisition affect image quality. Respiratory gating is commonly used to gate the list-mode PET data into multiple bins over a respiratory cycle. Non-rigid registration of respiratory-gated PET images can reduce motion artifacts and preserve count stat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8688

    authors: Li T,Zhang M,Qi W,Asma E,Qi J

    更新日期:2020-07-30 00:00:00

  • Scatter correction of cone-beam CT using a deep residual convolution neural network (DRCNN).

    abstract::Scatter correction is an essential technique to improve the image quality of cone-beam CT (CBCT). Although different scatter correction methods have been proposed in the literature, a standard solution is still being studied due to the limitations including accuracy, computation efficiency and generalization. In this ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab23a6

    authors: Jiang Y,Yang C,Yang P,Hu X,Luo C,Xue Y,Xu L,Hu X,Zhang L,Wang J,Sheng K,Niu T

    更新日期:2019-07-11 00:00:00

  • Changes in optical properties of ex vivo rat prostate due to heating.

    abstract::This study examines the effectiveness of a single, first-order Arrhenius process in accurately modelling the thermally induced changes in the optical properties, particularly the reduced scattering coefficient, mu(s)', and the absorption coefficient, mu(a), of ex vivo rat prostate. Recent work has shown that mu(s)' ca...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/5/319

    authors: Skinner MG,Everts S,Reid AD,Vitkin IA,Lilge L,Sherar MD

    更新日期:2000-05-01 00:00:00

  • Cascaded systems analysis of anatomic noise in digital mammography and dual-energy digital mammography.

    abstract::In x-ray based imaging of the breast, contrast between fibroglandular (Fg) tissue and adipose (Ad) tissue is a source of anatomic noise. The goal of this work was to validate by simulation and experiment a mathematical framework for modelling the Fg component of anatomic noise in digital mammograpy (DM) and dual-energ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab3fcd

    authors: Tanguay J,Lalonde R,Bjarnason TA,Yang CJ

    更新日期:2019-10-23 00:00:00

  • FBP-Net for direct reconstruction of dynamic PET images.

    abstract::Dynamic positron emission tomography (PET) imaging can provide information about metabolic changes over time, used for kinetic analysis and auxiliary diagnosis. Existing deep learning-based reconstruction methods have too many trainable parameters and poor generalization, and require mass data to train the neural netw...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abc09d

    authors: Wang B,Liu H

    更新日期:2020-10-13 00:00:00

  • 4D image reconstruction for emission tomography.

    abstract::An overview of the theory of 4D image reconstruction for emission tomography is given along with a review of the current state of the art, covering both positron emission tomography and single photon emission computed tomography (SPECT). By viewing 4D image reconstruction as a matter of either linear or non-linear par...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/59/22/R371

    authors: Reader AJ,Verhaeghe J

    更新日期:2014-11-21 00:00:00

  • Deep learning networks on chronic liver disease assessment with fine-tuning of shear wave elastography image sequences.

    abstract::Chronic liver disease (CLD) is currently one of the major causes of death worldwide. If not treated, it may lead to cirrhosis, hepatic carcinoma and death. Ultrasound (US) shear wave elastography (SWE) is a relatively new, popular, non-invasive technique among radiologists. Although many studies have been published va...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abae06

    authors: Kagadis GC,Drazinos P,Gatos I,Tsantis S,Papadimitroulas P,Spiliopoulos S,Karnabatidis D,Theotokas I,Zoumpoulis P,Hazle JD

    更新日期:2020-11-05 00:00:00

  • Performance measurements of a high-spatial-resolution YAP camera.

    abstract::Physical properties of a position-sensitive camera for the analysis of biodistributions of gamma- and beta-emitting radiopharmaceuticals in small animals have been studied, in order to achieve optimal operating conditions. The camera consisted of a highly segmented yttrium-aluminate perovskite (YAP) scintillator, coup...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/3/n01

    authors: Uzunov N,Bello M,Boccaccio P,Moschini G,Baldazzi G,Bollini D,de Notaristefani F,Mazzi U,Riondato M

    更新日期:2005-02-07 00:00:00

  • Treatment plan modification using voxel-based weighting factors/dose prescription.

    abstract::Under various clinical situations, it is desirable to modify the original treatment plan to better suit the clinical goals. In this work, a method to help physicians modify treatment plans based on their clinical preferences is proposed. The method uses a weighted quadratic dose objective function. The commonly used o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/15/315

    authors: Wu C,Olivera GH,Jeraj R,Keller H,Mackie TR

    更新日期:2003-08-07 00:00:00

  • An experimental evaluation of the Agility MLC for motion-compensated VMAT delivery.

    abstract::An algorithm for dynamic multileaf-collimator (dMLC) tracking of a target performing a known a priori, rigid-body motion during volumetric modulated arc therapy (VMAT), has been experimentally validated and applied to investigate the potential of the Agility (Elekta AB, Stockholm, Sweden) multileaf-collimator (MLC) fo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/13/4643

    authors: Davies GA,Clowes P,Bedford JL,Evans PM,Webb S,Poludniowski G

    更新日期:2013-07-07 00:00:00

  • Correlation between human and model observer performance for discrimination task in CT.

    abstract::Although physical metrics can objectively characterize computed tomography (CT) image quality, quantitative approaches to predict human observer performance are more accurate and clinically relevant. This study compared a modified channelized Hotelling model observer (CHO) with human observers in a shape discriminatio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/13/3389

    authors: Zhang Y,Leng S,Yu L,Carter RE,McCollough CH

    更新日期:2014-07-07 00:00:00

  • Spectrum reconstruction from dose measurements as a linear inverse problem.

    abstract::There are three ways to determine the spectrum of a clinical photon beam: direct measurement, modelling the source and reconstruction from ion-chamber measurements. We focus on reconstruction because the necessary equipment is readily available and it provides independent confirmation of source models for a given mach...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/22/005

    authors: Armbruster B,Hamilton RJ,Kuehl AK

    更新日期:2004-11-21 00:00:00

  • Rotational IMRT delivery using a digital linear accelerator in very high dose rate 'burst mode'.

    abstract::Recently, there has been a resurgence of interest in arc-based IMRT, through the use of 'conventional' multileaf collimator (MLC) systems that can treat large tumor volumes in a single, or very few pass(es) of the gantry. Here we present a novel 'burst mode' modulated arc delivery approach, wherein 2000 monitor units ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/7/002

    authors: Salter BJ,Sarkar V,Wang B,Shukla H,Szegedi M,Rassiah-Szegedi P

    更新日期:2011-04-07 00:00:00

  • Optimization of fluoroscopy parameters using pattern matching prediction in the real-time tumor-tracking radiotherapy system.

    abstract::In the real-time tumor-tracking radiotherapy system, fluoroscopy is used to determine the real-time position of internal fiducial markers. The pattern recognition score (PRS) ranging from 0 to 100 is computed by a template pattern matching technique in order to determine the marker position on the fluoroscopic image. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/15/011

    authors: Miyamoto N,Ishikawa M,Bengua G,Sutherland K,Suzuki R,Kimura S,Shimizu S,Onimaru R,Shirato H

    更新日期:2011-08-07 00:00:00