Optimization of fluoroscopy parameters using pattern matching prediction in the real-time tumor-tracking radiotherapy system.

Abstract:

:In the real-time tumor-tracking radiotherapy system, fluoroscopy is used to determine the real-time position of internal fiducial markers. The pattern recognition score (PRS) ranging from 0 to 100 is computed by a template pattern matching technique in order to determine the marker position on the fluoroscopic image. The PRS depends on the quality of the fluoroscopic image. However, the fluoroscopy parameters such as tube voltage, current and exposure duration are selected manually and empirically in the clinical situation. This may result in an unnecessary imaging dose from the fluoroscopy or loss of the marker because of too much or insufficient x-ray exposure. In this study, a novel optimization method is proposed in order to minimize the fluoroscopic dose while keeping the image quality usable for marker tracking. The PRS can be predicted in a region where the marker appears to move in the fluoroscopic image by the proposed method. The predicted PRS can be utilized to judge whether the marker can be tracked with accuracy. In this paper, experiments were performed to show the feasibility of the PRS prediction method under various conditions. The predicted PRS showed good agreement with the measured PRS. The root mean square error between the predicted PRS and the measured PRS was within 1.44. An experiment using a motion controller and an anthropomorphic chest phantom was also performed in order to imitate a clinical fluoroscopy situation. The result shows that the proposed prediction method is expected to be applicable in a real clinical situation.

journal_name

Phys Med Biol

authors

Miyamoto N,Ishikawa M,Bengua G,Sutherland K,Suzuki R,Kimura S,Shimizu S,Onimaru R,Shirato H

doi

10.1088/0031-9155/56/15/011

subject

Has Abstract

pub_date

2011-08-07 00:00:00

pages

4803-13

issue

15

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(11)87555-X

journal_volume

56

pub_type

杂志文章
  • Aperture modulated arc therapy.

    abstract::We show that it is possible to translate an intensity modulated radiation therapy (IMRT) treatment plan and deliver it as a single arc. This technique is referred to in this paper as aperture modulation arc therapy (AMAT). During this arc, the MLC leaves do not conform to the projection of the target PTV and the machi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/10/307

    authors: Crooks SM,Wu X,Takita C,Watzich M,Xing L

    更新日期:2003-05-21 00:00:00

  • SAR calculations in an anatomically realistic model of the head for mobile communication transceivers at 900 MHz and 1.8 GHz.

    abstract::A new mathematical model of the head has been constructed from a set of serial MRI slices from one subject. Finite-difference time-domain (FDTD) calculations of the specific energy absorption rate (SAR) have been performed on this model with a 2 mm resolution for a generic mobile communication transceiver represented ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/10/003

    authors: Dimbylow PJ,Mann SM

    更新日期:1994-10-01 00:00:00

  • Monte Carlo generated mammograms: development and validation.

    abstract::We have developed a model using Monte Carlo methods to simulate x-ray mammography. All possible physical processes of interaction of x-rays with matter have been taken into account. A simplified geometry of the mammographic apparatus has been considered along with a software phantom of compressed breast. The phantom m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/11/012

    authors: Spyrou G,Tzanakos G,Bakas A,Panayiotakis G

    更新日期:1998-11-01 00:00:00

  • Monte Carlo- versus pencil-beam-/collapsed-cone-dose calculation in a heterogeneous multi-layer phantom.

    abstract::The aim of this work was to evaluate the accuracy of dose predicted in heterogeneous media by a pencil beam (PB), a collapsed cone (CC) and a Monte Carlo (MC) algorithm. For this purpose, a simple multi-layer phantom composed of Styrofoam and white polystyrene was irradiated with 10 x 10 cm2 as well as 20 x 20 cm2 ope...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/5/010

    authors: Krieger T,Sauer OA

    更新日期:2005-03-07 00:00:00

  • The influence of metal artefacts on the range of ion beams.

    abstract::The influence of artefacts due to metal implants on the range of ion beams is investigated, using a geometrically well-defined head and pelvic phantom together with inserts from steel, titanium and tungsten. The ranges along various beam paths including artefacts were calculated from the TPS and compared to known calc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/3/007

    authors: Jäkel O,Reiss P

    更新日期:2007-02-07 00:00:00

  • High intensity focused ultrasound for the treatment of rat tumours.

    abstract::Discrete implanted liver tumours in the rat have been exposed to arrays of 1.7 MHz ultrasound lesions. Focal peak intensities in the range 1.4-3.5 k Wcm-2 were used for an exposure time of 10 s. It has been demonstrated that where the whole tumour volume was exposed to the focused ultrasound beam, no evidence of tumou...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/11/009

    authors: ter Haar G,Rivens I,Chen L,Riddler S

    更新日期:1991-11-01 00:00:00

  • Use of an amorphous silicon EPID for measuring MLC calibration at varying gantry angle.

    abstract::Amorphous silicon electronic portal imaging devices (EPIDs) are used to perform routine quality control (QC) checks on the multileaf collimators (MLCs) at this centre. Presently, these checks are performed at gantry angle 0 degrees and are considered to be valid for all other angles. Since therapeutic procedures regul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/2/013

    authors: Clarke MF,Budgell GJ

    更新日期:2008-01-21 00:00:00

  • A robust approach to IMRT optimization.

    abstract::Managing uncertainty is a major challenge in radiation therapy treatment planning, including uncertainty induced by intrafraction motion, which is particularly important for tumours in the thorax and abdomen. Common methods to account for motion are to introduce a margin or to convolve the static dose distribution wit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/10/014

    authors: Chan TC,Bortfeld T,Tsitsiklis JN

    更新日期:2006-05-21 00:00:00

  • An age-dependent series of eye models for radiation dosimetry.

    abstract::Several studies have been appeared, up to now, that indicate the effect of accurate simulation on dose received by different substructures of the eye, irradiated by external beams of short-range radiation such as electron. Different representations of the eye have consequently been introduced. Their accuracies depend ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2059

    authors: Vejdani-Noghreiyan A,Ebrahimi-Khankook A

    更新日期:2019-07-02 00:00:00

  • A potential method for in vivo range verification in proton therapy treatment.

    abstract::Proton therapy potentially offers excellent dose conformality and reduction in integral dose. The superior dose distribution is, however, much more sensitive to the radiological depth along the beam path than for photon fields. Variations in this depth due to inaccurate planning calculation, setup uncertainty, respira...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/5/016

    authors: Lu HM

    更新日期:2008-03-07 00:00:00

  • STIR: software for tomographic image reconstruction release 2.

    abstract::We present a new version of STIR (Software for Tomographic Image Reconstruction), an open source object-oriented library implemented in C++ for 3D positron emission tomography reconstruction. This library has been designed such that it can be used for many algorithms and scanner geometries, while being portable to var...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/4/867

    authors: Thielemans K,Tsoumpas C,Mustafovic S,Beisel T,Aguiar P,Dikaios N,Jacobson MW

    更新日期:2012-02-21 00:00:00

  • Navigated non-contact fluorescence tomography.

    abstract::A non-contact approach for diffuse optical tomography (DOT) has been developed for on-demand image updates using surgical navigation technology. A stereoscopic optical tracker provides real-time localization of reflective spheres mounted to a laser diode and near-infrared camera. Standard camera calibration is combine...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab1f33

    authors: Daly MJ,Wilson BC,Irish JC,Jaffray DA

    更新日期:2019-07-05 00:00:00

  • Low-dose 4D cardiac imaging in small animals using dual source micro-CT.

    abstract::Micro-CT is widely used in preclinical studies, generating substantial interest in extending its capabilities in functional imaging applications such as blood perfusion and cardiac function. However, imaging cardiac structure and function in mice is challenging due to their small size and rapid heart rate. To overcome...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa9b45

    authors: Holbrook M,Clark DP,Badea CT

    更新日期:2018-01-09 00:00:00

  • Effect of dominant features on neural network performance in the classification of mammographic lesions.

    abstract::Two different classifiers, an artificial neural network (ANN) and a hybrid system (one step rule-based method followed by an artificial neural network) have been investigated to merge computer-extracted features in the task of differentiating between malignant and benign masses. A database consisting of 65 cases (38 m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/10/315

    authors: Huo Z,Giger ML,Metz CE

    更新日期:1999-10-01 00:00:00

  • First in-beam PET measurement of beta+ radioactivity induced by hard photon beams.

    abstract::In this note, we present the first experimental results of in-beam PET measurements during high energy photon phantom irradiation. An inhomogeneous phantom was irradiated with pulsed 34 MV bremsstrahlung. The measurements have been conducted with a dedicated double head positron camera. A high material contrast could ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/20/N01

    authors: Kluge T,Möckel D,Pawelke J,Enghardt W

    更新日期:2007-10-21 00:00:00

  • Non-uniform depth scanning for proton therapy systems employing active energy variation.

    abstract::In proton scanning systems that employ active energy variation for depth modulation, a switch of the particle energy might typically require 1-2 s. For plans comprising many energy slices, these seconds could sum up to a non-negligible fraction of the total treatment duration. We have applied the Nyquist-Shannon sampl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/9/N01

    authors: Kang JH,Wilkens JJ,Oelfke U

    更新日期:2008-05-07 00:00:00

  • Diagnostic imaging over the last 50 years: research and development in medical imaging science and technology.

    abstract::Over the last 50 years, diagnostic imaging has grown from a state of infancy to a high level of maturity. Many new imaging modalities have been developed. However, modern medical imaging includes not only image production but also image processing, computer-aided diagnosis (CAD), image recording and storage, and image...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/51/13/R02

    authors: Doi K

    更新日期:2006-07-07 00:00:00

  • Effect of inter-crystal scatter on estimation methods for random coincidences and subsequent correction.

    abstract::Random coincidences can contribute substantially to the background in positron emission tomography (PET). Several estimation methods are being used for correcting them. The goal of this study was to investigate the validity of techniques for random coincidence estimation, with various low-energy thresholds (LETs). Sim...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/9/012

    authors: Torres-Espallardo I,Rafecas M,Spanoudaki V,McElroy DP,Ziegler SI

    更新日期:2008-05-07 00:00:00

  • Improved dose-calculation accuracy in proton treatment planning using a simplified Monte Carlo method verified with three-dimensional measurements in an anthropomorphic phantom.

    abstract::Treatment planning for proton tumor therapy requires a fast and accurate dose-calculation method. We have implemented a simplified Monte Carlo (SMC) method in the treatment planning system of the National Cancer Center Hospital East for the double-scattering beam delivery scheme. The SMC method takes into account the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/12/018

    authors: Hotta K,Kohno R,Takada Y,Hara Y,Tansho R,Himukai T,Kameoka S,Matsuura T,Nishio T,Ogino T

    更新日期:2010-06-21 00:00:00

  • Prototyping a large field size IORT applicator for a mobile linear accelerator.

    abstract::The treatment of large tumors such as sarcomas with intra-operative radiotherapy using a Mobetron is often complicated because of the limited field size of the primary collimator and the available applicators (max Ø100 mm). To circumvent this limitation a prototype rectangular applicator of 80 x 150 mm(2) was designed...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/8/006

    authors: Janssen RW,Faddegon BA,Dries WJ

    更新日期:2008-04-21 00:00:00

  • 4D digital tomosynthesis image reconstruction using brute force-based adaptive total variation (BF-ATV) in a prototype LINAC system.

    abstract::Respiratory-correlated cone-beam CT (CBCT) not only inhibits rapid scanning due to the slow speed of the LINAC head gantry rotation, but its implementation for routine patient imaging is impractical because of the high radiation dose delivered during the process. Digital tomosynthesis (DTS) is a potentially faster tec...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab0d50

    authors: Choi S,Lee S,Kang YN,Hsieh SS,Kim HJ

    更新日期:2019-05-02 00:00:00

  • Determining clinical photon beam spectra from measured depth dose with the Cimmino algorithm.

    abstract::A method to determine the spectrum of a clinical photon beam from measured depth-dose data is described. At shallow depths, where the range of Compton-generated electrons increases rapidly with photon energy, the depth dose provides the information to discriminate the spectral contributions. To minimize the influence ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/1/312

    authors: Bloch P,Altschuler MD,Bjärngard BE,Kassaee A,McDonough J

    更新日期:2000-01-01 00:00:00

  • Improving single-event proton CT by removing nuclear interaction events within the energy/range detector.

    abstract::Data filtering is crucial for accurate relative stopping power (RSP) reconstruction in proton CT (pCT). In this work, we assess different filters and their performance for the US pCT collaboration prototype pCT system in Monte Carlo (MC) simulations. The potential of using the recently proposed [Formula: see text]-E f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2671

    authors: Volz L,Piersimoni P,Johnson RP,Bashkirov VA,Schulte RW,Seco J

    更新日期:2019-08-01 00:00:00

  • Automated prostate segmentation in whole-body MRI scans for epidemiological studies.

    abstract::The whole prostatic volume (PV) is an important indicator for benign prostate hyperplasia. Correlating the PV with other clinical parameters in a population-based prospective cohort study (SHIP-2) requires valid prostate segmentation in a large number of whole-body MRI scans. The axial proton density fast spin echo fa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/17/5899

    authors: Habes M,Schiller T,Rosenberg C,Burchardt M,Hoffmann W

    更新日期:2013-09-07 00:00:00

  • Suitability of EBT3 GafChromic film for quality assurance in MR-guided radiotherapy at 0.35 T with and without real-time MR imaging.

    abstract::The 0.35 T 60Co MRIdian system (ViewRay Inc., Mountain View) has been in clinical use in our institution since May 2016. For quality assurance (QA) of dose delivery and end-to-end testing for this machine, a reliable dosimeter is required. However, it is possible that a magnetic field may cause perturbations to dosime...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad58d

    authors: Barten DLJ,Hoffmans D,Palacios MA,Heukelom S,van Battum LJ

    更新日期:2018-08-20 00:00:00

  • Influence of the SURLAS applicator on radiation dose distributions during simultaneous thermoradiotherapy with helical tomotherapy.

    abstract::Simultaneous thermoradiotherapy has been shown to maximize the effect of hyperthermia as a radiation sensitizer in cancer treatment. Here we follow our previous work on feasibility of thermoradiotherapy with the scanning ultrasound reflector linear array system (SURLAS) and TomoTherapy HiArt treatment system, and inve...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/10/004

    authors: Novák P,Peñagarícano JA,Nahirnyak V,Corry P,Moros EG

    更新日期:2008-05-21 00:00:00

  • Assessment of the accuracy of an MCNPX-based Monte Carlo simulation model for predicting three-dimensional absorbed dose distributions.

    abstract::In recent years, the Monte Carlo method has been used in a large number of research studies in radiation therapy. For applications such as treatment planning, it is essential to validate the dosimetric accuracy of the Monte Carlo simulations in heterogeneous media. The AAPM Report no 105 addresses issues concerning cl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/16/016

    authors: Titt U,Sahoo N,Ding X,Zheng Y,Newhauser WD,Zhu XR,Polf JC,Gillin MT,Mohan R

    更新日期:2008-08-21 00:00:00

  • Improved accuracy of markerless motion tracking on bone suppression images: preliminary study for image-guided radiation therapy (IGRT).

    abstract::The bone suppression technique based on advanced image processing can suppress the conspicuity of bones on chest radiographs, creating soft tissue images obtained by the dual-energy subtraction technique. This study was performed to evaluate the usefulness of bone suppression image processing in image-guided radiation...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/10/n209

    authors: Tanaka R,Sanada S,Sakuta K,Kawashima H

    更新日期:2015-05-21 00:00:00

  • In vivo evaluation of a new system for 3D computerized angiography.

    abstract::A new system has been designed and built to validate the concept of 3D computerized angiography (CA). This system can acquire a set of 2D digital subtracted angiography images while rotating around a patient and then, using these images, reconstruct a 3D representation of the opacified vasculature. The design principl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/3/020

    authors: Saint-Félix D,Trousset Y,Picard C,Ponchut C,Roméas R,Rougée A

    更新日期:1994-03-01 00:00:00

  • An analytical algorithm for skew-slit collimator SPECT with uniform attenuation correction.

    abstract::To replace the conventional pinhole (normal cone-beam) collimator, a novel skew-slit collimator was previously proposed and a Novikov-type algorithm developed to reconstruct images using the skew-slit geometry. The goal of this paper is to develop a reconstruction algorithm that has better noise control than the Novik...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/23/018

    authors: Tang Q,Zeng GL,Huang Q

    更新日期:2006-12-07 00:00:00