Monte Carlo generated mammograms: development and validation.

Abstract:

:We have developed a model using Monte Carlo methods to simulate x-ray mammography. All possible physical processes of interaction of x-rays with matter have been taken into account. A simplified geometry of the mammographic apparatus has been considered along with a software phantom of compressed breast. The phantom may contain inhomogeneities of various compositions and sizes. We have used this model to produce Monte Carlo mammograms under realistic conditions. The validation of the simulation includes both the modelling of physical processes and the production of Monte Carlo mammograms. The first part is accomplished by the demonstration of the coincidence between Monte Carlo and theoretical data, whereas the second is accomplished by the comparison of real mammograms, taken from irradiation of a simplified breast phantom that we have constructed, and Monte Carlo mammograms taken from simulation of the above phantom under the corresponding exposure conditions. The limitations of the model as well as the future use of Monte Carlo mammograms are discussed.

journal_name

Phys Med Biol

authors

Spyrou G,Tzanakos G,Bakas A,Panayiotakis G

doi

10.1088/0031-9155/43/11/012

subject

Has Abstract

pub_date

1998-11-01 00:00:00

pages

3341-57

issue

11

eissn

0031-9155

issn

1361-6560

journal_volume

43

pub_type

杂志文章
  • Estimation of percentage body fat by dual-energy x-ray absorptiometry: evaluation by in vivo human elemental composition.

    abstract::Dual-energy x-ray absorptiometry (DXA) is widely applied for estimating body fat. The percentage of body mass as fat (%fat) is predicted from a DXA-estimated R(ST) value defined as the ratio of soft tissue attenuation at two photon energies (e.g., 40 keV and 70 keV). Theoretically, the R(ST) concept depends on the mas...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/9/013

    authors: Wang Z,Heymsfield SB,Chen Z,Zhu S,Pierson RN

    更新日期:2010-05-07 00:00:00

  • Calculation of radiation exposures from patients to whom radioactive materials have been administered.

    abstract::Spreadsheet templates which calculate cumulative exposures to other persons from patients to whom radioactive materials have been administered have been developed by the authors. Calculations can be based on any specified single-, bi- or tri-exponential whole-body clearance rate and a diurnal (or any other periodic) c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/3/003

    authors: Cormack J,Shearer J

    更新日期:1998-03-01 00:00:00

  • Monte Carlo- versus pencil-beam-/collapsed-cone-dose calculation in a heterogeneous multi-layer phantom.

    abstract::The aim of this work was to evaluate the accuracy of dose predicted in heterogeneous media by a pencil beam (PB), a collapsed cone (CC) and a Monte Carlo (MC) algorithm. For this purpose, a simple multi-layer phantom composed of Styrofoam and white polystyrene was irradiated with 10 x 10 cm2 as well as 20 x 20 cm2 ope...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/5/010

    authors: Krieger T,Sauer OA

    更新日期:2005-03-07 00:00:00

  • Deep learning on mammary glands distribution for architectural distortion detection in digital breast tomosynthesis.

    abstract::Computer aided detection (CADe) for breast lesion can provide an important reference for radiologists in breast cancer screening. Architectural distortion (AD) is a type of breast lesion that is difficult to detect. A majority of CADe methods focus on detecting the radial pattern, which is a main characteristic of typ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab98d0

    authors: Li Y,He Z,Lu Y,Ma X,Guo Y,Xie Z,Xu Z,Chen W,Chen H

    更新日期:2020-06-02 00:00:00

  • Benchmarking GATE/Geant4 for 16O ion beam therapy.

    abstract::Oxygen ([Formula: see text]) ions are a potential alternative to carbon ions in ion beam therapy. Their enhanced linear energy transfer indicates a higher relative biological effectiveness and a reduced oxygen enhancement ratio. Due to the limited availability of [Formula: see text] ion beams, Monte Carlo (MC) transpo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa807e

    authors: Resch AF,Fuchs H,Georg D

    更新日期:2017-09-05 00:00:00

  • Optimisation of field flatness and depth-dose for therapy electron beams.

    abstract::Curves relating beam energy, scattering foil thickness, central-axis depth-dose, and beam flatness have been generated using data taken on a Siemens 200A betatron. The curve set allows a single combination of tungsten foil thickness and electron beam energy to be chosen that will provide the optimum depth-dose distrib...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/26/3/007

    authors: Marbach JR,Almond PR

    更新日期:1981-05-01 00:00:00

  • Comments on 'Calculation of water equivalent thickness of materials of arbitrary density, elemental composition and thickness in proton beam irradiation'.

    abstract::We comment on a previous article by Zhang and Newhauser (2009 Phys. Med. Biol. 54 1383-95) which presents several approximate ways of computing the water equivalent of an arbitrary degrader. First, we present a simple exact method which depends only on the range-energy relation of water and of the degrader material. S...

    journal_title:Physics in medicine and biology

    pub_type: 评论,信件

    doi:10.1088/0031-9155/55/9/L01

    authors: Gottschalk B

    更新日期:2010-05-07 00:00:00

  • Post-processing noise removal algorithm for magnetic resonance imaging based on edge detection and wavelet analysis.

    abstract::A post-processing noise suppression technique for biomedical MRI images is presented. The described procedure recovers both sharp edges and smooth surfaces from a given noisy MRI image; it does not blur the edges and does not introduce spikes or other artefacts. The fine details of the image are also preserved. The pr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/13/310

    authors: Placidi G,Alecci M,Sotgiu A

    更新日期:2003-07-07 00:00:00

  • An FDK-like cone-beam SPECT reconstruction algorithm for non-uniform attenuated projections acquired using a circular trajectory.

    abstract::In this paper, Novikov's inversion formula of the attenuated two-dimensional (2D) Radon transform is applied to the reconstruction of attenuated fan-beam projections acquired with equal detector spacing and of attenuated cone-beam projections acquired with a flat planar detector and circular trajectory. The derivation...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/10/010

    authors: Huang Q,Zeng GL,You J,Gullberg GT

    更新日期:2005-05-21 00:00:00

  • The use of gel dosimetry for verification of electron and photon treatment plans in carcinoma of the scalp.

    abstract::In recent years there has been a large amount of research into the potential use of radiation sensitive gels for three-dimensional verification of clinical radiotherapy doses. In this paper we report the use of a MAGIC gel dosimeter (Fong et al 2001 Phys. Med. Biol. 46 3105) for the verification of a specific patient'...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/9/003

    authors: Trapp JV,Partridge M,Hansen VN,Childs P,Bedford J,Warrington AP,Leach MO,Webb S

    更新日期:2004-05-07 00:00:00

  • The relevance of very low energy ions for heavy-ion therapy.

    abstract::Heavy-ion radiotherapy exploits the high biological effectiveness of localized energy deposition delivered by so-called Bragg-peak particles. Recent publications have challenged the established procedures to calculate biological effective dose distributions in treatment planning. They emphasize the importance of very ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/7/N03

    authors: Elsässer T,Gemmel A,Scholz M,Schardt D,Krämer M

    更新日期:2009-04-07 00:00:00

  • A double-tuned (1)H/(23)Na dual resonator system for tissue sodium concentration measurements in the rat brain via Na-MRI.

    abstract::A method for quantifying the tissue sodium concentration (TSC) in the rat brain from ²³Na-MR images was developed. TSC is known to change in a variety of common human diseases and holds considerable potential to contribute to their study; however, its accurate measurement in small laboratory animals has been hindered ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/24/019

    authors: Wetterling F,Tabbert M,Junge S,Gallagher L,Macrae IM,Fagan AJ

    更新日期:2010-12-21 00:00:00

  • Variability among polysulphone calibration curves.

    abstract::Within an epidemiological study regarding the correlation between skin pathologies and personal ultraviolet (UV) exposure due to solar radiation, 14 field campaigns using polysulphone (PS) dosemeters were carried out at three different Italian sites (urban, semi-rural and rural) in every season of the year. A polysulp...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/17/019

    authors: Casale GR,Borra M,Colosimo A,Colucci M,Militello A,Siani AM,Sisto R

    更新日期:2006-09-07 00:00:00

  • Single-shot K-edge subtraction x-ray discrete computed tomography with a polychromatic source and the Pixie-III detector.

    abstract::K-edge subtraction (KES) imaging is a technique able to map a specific element such as e.g. a contrast agent within the tissues, by exploiting the sharp rise of its absorption coefficient at the K-edge energy. Whereas mainly explored at synchrotron radiation sources, the energy discrimination properties of modern x-ra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab7105

    authors: Brun F,Di Trapani V,Albers J,Sacco P,Dreossi D,Brombal L,Rigon L,Longo R,Mittone A,Dullin C,Bravin A,Delogu P

    更新日期:2020-03-06 00:00:00

  • Experimental determination of pCo perturbation factors for plane-parallel chambers.

    abstract::For plane-parallel chambers used in electron dosimetry, modern dosimetry protocols recommend a cross-calibration against a calibrated cylindrical chamber. The rationale for this is the unacceptably large (up to 3-4%) chamber-to-chamber variations of the perturbation factors (pwall)Co, which have been reported for plan...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,多中心研究

    doi:10.1088/0031-9155/52/23/026

    authors: Kapsch RP,Bruggmoser G,Christ G,Dohm OS,Hartmann GH,Schüle E

    更新日期:2007-12-07 00:00:00

  • A fast and sensitive TLD method for measurement of energy and homogeneity of electron beams using transmitted radiation through lead.

    abstract::A simple and fast, but sensitive TLD method for the measurement of energy and homogeneity of therapeutically used electron beams has been developed and tested. This method is based on the fact that when small thicknesses of high-Z absorbers such as lead are interposed in the high-energy electron beams, the transmitted...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/9/005

    authors: Pradhan AS,Quast U,Sharma PK

    更新日期:1994-09-01 00:00:00

  • Novel adaptive beam-dependent margins for additional OAR sparing.

    abstract::Margins are employed in radiotherapy treatment planning to mitigate the dosimetric effects of geometric uncertainties for the clinical target volume (CTV). Unfortunately, whilst the use of margins can increase the probability that sufficient dose is delivered to the CTV, it can also result in delivering high dose of r...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aae658

    authors: Tsang HS,Kamerling CP,Ziegenhein P,Nill S,Oelfke U

    更新日期:2018-10-29 00:00:00

  • Comment on 'the use of the Henyey-Greenstein phase function in Monte Carlo simulations in biomedical optics'.

    abstract::In this letter the authors highlight the presence of an error appearing in the discussion of the note 'The use of the Henyey-Greenstein phase function in Monte Carlo simulations in biomedical optics' previously published by them (Binzoni et al 2006 Phys. Med. Biol. 51 N313). In the light of this error, the discussion ...

    journal_title:Physics in medicine and biology

    pub_type: 评论,信件

    doi:10.1088/0031-9155/51/22/L01

    authors: Binzoni T,Leung TS,Gandjbakhche AH,Rüfenacht D,Delpy DT

    更新日期:2006-11-21 00:00:00

  • The quality of ionising radiations emitted by radionuclides incorporated into mammalian cells.

    abstract::Radionuclides which decay by electron capture accompanied by Auger electron cascades, or by beta emission are thought to be excessively damaging when incorporated into the molecular structure of mammalian cell nuclei and thereby pose a radiation hazard which is not assessable by conventional dosimetry. Survival data, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/7/003

    authors: Younis AR,Watt DE

    更新日期:1989-07-01 00:00:00

  • Modeling localized delivery of Doxorubicin to the brain following focused ultrasound enhanced blood-brain barrier permeability.

    abstract::Doxorubicin (Dox) is a well-established chemotherapeutic agent, however it has limited efficacy in treating brain malignancies due to the presence of the blood-brain barrier (BBB). Recent preclinical studies have demonstrated that focused ultrasound induced BBB disruption (BBBD) enables efficient delivery of Dox to th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/20/5987

    authors: Nhan T,Burgess A,Lilge L,Hynynen K

    更新日期:2014-10-21 00:00:00

  • Correction-less dosimetry of nonstandard photon fields: a new criterion to determine the usability of radiation detectors.

    abstract::In the IAEA-AAPM dosimetry formalism, detector measurements in general nonstandard conditions are corrected using the factor k(f(clin),f(msr))(Q(clin),Q(msr)). This factor needs to be evaluated on a case-by-case basis which is difficult to accomplish in practice. The present paper aims to provide a method that allows ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/17/4973

    authors: Kamio Y,Bouchard H

    更新日期:2014-09-07 00:00:00

  • Beam angle selection incorporation of anatomical heterogeneities for pencil beam scanning charged-particle therapy.

    abstract::In charged particle therapy with pencil beam scanning (PBS), localization of the dose in the Bragg peak makes dose distributions sensitive to lateral tissue heterogeneities. The sensitivity of a PBS plan to lateral tissue heterogeneities can be reduced by selecting appropriate beam angles. The purpose of this study is...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/61/24/8664

    authors: Toramatsu C,Inaniwa T

    更新日期:2016-12-21 00:00:00

  • An experimental evaluation of the Agility MLC for motion-compensated VMAT delivery.

    abstract::An algorithm for dynamic multileaf-collimator (dMLC) tracking of a target performing a known a priori, rigid-body motion during volumetric modulated arc therapy (VMAT), has been experimentally validated and applied to investigate the potential of the Agility (Elekta AB, Stockholm, Sweden) multileaf-collimator (MLC) fo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/13/4643

    authors: Davies GA,Clowes P,Bedford JL,Evans PM,Webb S,Poludniowski G

    更新日期:2013-07-07 00:00:00

  • FPGA-based distributed coincidence processor for high count-rate online PET coincidence data acquisition.

    abstract::For PET online data acquisition, a centralized coincidence processor (CCP) with a single-thread data processing has been used to select coincidence events for many PET scanners. CCP has the advantage of highly integrated circuit, compact connection between detector front-end and system electronics, and centralized con...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abde85

    authors: Cheng X,Hu K,Yang D,Shao Y

    更新日期:2021-01-21 00:00:00

  • The influence of metal artefacts on the range of ion beams.

    abstract::The influence of artefacts due to metal implants on the range of ion beams is investigated, using a geometrically well-defined head and pelvic phantom together with inserts from steel, titanium and tungsten. The ranges along various beam paths including artefacts were calculated from the TPS and compared to known calc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/3/007

    authors: Jäkel O,Reiss P

    更新日期:2007-02-07 00:00:00

  • Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol.

    abstract::The UK and European protocols for mammographic dosimetry use conversion factors that relate incident air kerma to the mean glandular dose (MGD) within the breast. The conversion factors currently used were obtained by computer simulation of a model breast with a composition of 50% adipose and 50% glandular tissues by ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/11/308

    authors: Dance DR,Skinner CL,Young KC,Beckett JR,Kotre CJ

    更新日期:2000-11-01 00:00:00

  • The MLC tongue-and-groove effect on IMRT dose distributions.

    abstract::We have investigated the tongue-and-groove effect on the IMRT dose distributions for a Varian MLC. We have compared the dose distributions calculated using the intensity maps with and without the tongue-and-groove effect. Our results showed that, for one intensity-modulated treatment field, the maximum tongue-and-groo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/4/310

    authors: Deng J,Pawlicki T,Chen Y,Li J,Jiang SB,Ma CM

    更新日期:2001-04-01 00:00:00

  • The radiation dose from a proposed measurement of arsenic and selenium in human skin.

    abstract::Dose measurements following 10 min irradiations with a portable x-ray fluorescence spectrometer composed of a miniature x-ray tube and a silicon PiN diode detector were performed using thermoluminescent dosimeters consisting of LiF:Mg,Ti chips of 3 mm diameter and 0.4 mm thickness. The table-top setup of the spectrome...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/18/015

    authors: Gherase MR,Mader JE,Fleming DE

    更新日期:2010-09-21 00:00:00

  • An alternative to gamma histograms for ROI-based quantitative dose comparisons.

    abstract::An alternative to gamma (gamma) histograms for ROI-based quantitative comparisons of dose distributions using the gamma concept is proposed. The method provides minimum values of dose difference and distance-to-agreement such that a pre-set fraction of the region of interest passes the gamma test. Compared to standard...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/12/N03

    authors: Dvorak P

    更新日期:2009-06-21 00:00:00

  • Optimization of image quality and dose for Varian aS500 electronic portal imaging devices (EPIDs).

    abstract::This study was carried out to investigate whether the electronic portal imaging (EPI) acquisition process could be optimized, and as a result tolerance and action levels be set for the PIPSPro QC-3V phantom image quality assessment. The aim of the optimization process was to reduce the dose delivered to the patient wh...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/23/006

    authors: McGarry CK,Grattan MW,Cosgrove VP

    更新日期:2007-12-07 00:00:00