Determining clinical photon beam spectra from measured depth dose with the Cimmino algorithm.

Abstract:

:A method to determine the spectrum of a clinical photon beam from measured depth-dose data is described. At shallow depths, where the range of Compton-generated electrons increases rapidly with photon energy, the depth dose provides the information to discriminate the spectral contributions. To minimize the influence of contaminating electrons, small (6 x 6 cm2) fields were used. The measured depth dose is represented as a linear combination of basis functions, namely the depth doses of monoenergetic photon beams derived by Monte Carlo simulations. The weights of the basis functions were obtained with the Cimmino feasibility algorithm, which examines in each iteration the discrepancy between predicted and measured depth dose. For 6 and 15 MV photon beams of a clinical accelerator, the depth dose obtained from the derived spectral weights was within about 1% of the measured depth dose at all depths. Because the problem is ill conditioned, solutions for the spectrum can fluctuate with energy. Physically realistic smooth spectra for these photon beams appeared when a small margin (about +/- 1%) was attributed to the measured depth dose. The maximum energy of both derived spectra agreed with the measured energy of the electrons striking the target to within 1 MeV. The use of a feasibility method on minimally relaxed constraints provides realistic spectra quickly and interactively.

journal_name

Phys Med Biol

authors

Bloch P,Altschuler MD,Bjärngard BE,Kassaee A,McDonough J

doi

10.1088/0031-9155/45/1/312

subject

Has Abstract

pub_date

2000-01-01 00:00:00

pages

171-83

issue

1

eissn

0031-9155

issn

1361-6560

journal_volume

45

pub_type

杂志文章
  • Optimizing robot motion for robotic ultrasound-guided radiation therapy.

    abstract::An important aspect of robotic radiation therapy is active compensation of target motion. Recently, ultrasound has been proposed to obtain real-time volumetric images of abdominal organ motion. One approach to realize flexible probe placement throughout the treatment fraction is based on a robotic arm holding the ultr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab3bfb

    authors: Schlüter M,Fürweger C,Schlaefer A

    更新日期:2019-10-04 00:00:00

  • Hybrid scatter correction applied to quantitative holmium-166 SPECT.

    abstract::Ho-166 is a combined beta-gamma emitter of which the betas can be used therapeutically. From the 81 keV gammas of Ho-166, SPECT images can be obtained, which give opportunities to guide Ho-166 therapy. Accurate reconstruction of Ho-166 images is currently hampered by photopeak-scatter in the patient, down-scatter in t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/19/004

    authors: de Wit TC,Xiao J,Nijsen JF,van het Schip FD,Staelens SG,van Rijk PP,Beekman FJ

    更新日期:2006-10-07 00:00:00

  • Conical beam geometry intensity-modulated radiation therapy.

    abstract::Most commonly in radiation therapy, treatments are delivered in a co-planar geometry. Numerous advantages have been reported of adding non-coplanar beams to the treatment plan. The aim of this study was to compare current state-of-the-art VMAT and CyberKnife treatment plans to that of a novel linac design developed at...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab246f

    authors: Schüler E,Wang L,Loo BW,Maxim PG

    更新日期:2019-06-20 00:00:00

  • Improving source detection and separation in a spatiotemporal Bayesian inference dipole analysis.

    abstract::Most existing spatiotemporal multi-dipole approaches for MEG/EEG source localization assume that the dipoles are active for the full time range being analysed. If the actual time range of activity of sources is significantly shorter than the time range being analysed, the detectability, localization and time-course de...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/10/004

    authors: Jun SC,George JS,Plis SM,Ranken DM,Schmidt DM,Wood CC

    更新日期:2006-05-21 00:00:00

  • A convolution-subtraction scatter correction method for 3D PET.

    abstract::3D acquisition and reconstruction in positron emission tomography (PET) produce data with improved signal-to-noise ratios compared with conventional 2D slice-oriented methods. However, the sensitivity increase is accompanied by an increase in the number of scattered photons and random coincidences detected. This paper...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/3/009

    authors: Bailey DL,Meikle SR

    更新日期:1994-03-01 00:00:00

  • Iterative reconstruction of SiPM light response functions in a square-shaped compact gamma camera.

    abstract::Compact gamma cameras with a square-shaped monolithic scintillator crystal and an array of silicon photomultipliers (SiPMs) are actively being developed for applications in areas such as small animal imaging, cancer diagnostics and radiotracer guided surgery. Statistical methods of position reconstruction, which are p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6029

    authors: Morozov A,Alves F,Marcos J,Martins R,Pereira L,Solovov V,Chepel V

    更新日期:2017-05-07 00:00:00

  • High resolution propagation-based imaging system for in vivo dynamic computed tomography of lungs in small animals.

    abstract::We have developed an x-ray imaging system for in vivo four-dimensional computed tomography (4DCT) of small animals for pre-clinical lung investigations. Our customized laboratory facility is capable of high resolution in vivo imaging at high frame rates. Characterization using phantoms demonstrate a spatial resolution...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aab8d2

    authors: Preissner M,Murrie RP,Pinar I,Werdiger F,Carnibella RP,Zosky GR,Fouras A,Dubsky S

    更新日期:2018-04-20 00:00:00

  • On the surviving fraction in irradiated multicellular tumour spheroids: calculation of overall radiosensitivity parameters, influence of hypoxia and volume effects.

    abstract::We model the heterogeneous response to radiation of multicellular tumour spheroids assuming position- and volume-dependent radiosensitivity. We propose a method to calculate the overall radiosensitivity parameters to obtain the surviving fraction of tumours. A mathematical model of a spherical tumour with a hypoxic co...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/8/005

    authors: Horas JA,Olguin OR,Rizzotto MG

    更新日期:2005-04-21 00:00:00

  • Development and evaluation of a deep learning based artificial intelligence for automatic identification of gold fiducial markers in an MRI-only prostate radiotherapy workflow.

    abstract::Identification of prostate gold fiducial markers in magnetic resonance imaging (MRI) images is challenging when CT images are not available, due to misclassifications from intra-prostatic calcifications. It is also a time consuming task and automated identification methods have been suggested as an improvement for bot...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abb0f9

    authors: Gustafsson CJ,Swärd J,Adalbjörnsson SI,Jakobsson A,Olsson LE

    更新日期:2020-11-12 00:00:00

  • Adaptation and applications of a realistic digital phantom based on patient lung tumor trajectories.

    abstract::Digital phantoms continue to play a significant role in modeling and characterizing medical imaging. The currently available XCAT phantom incorporates both the flexibility of mathematical phantoms and the realistic nature of voxelized phantoms. This phantom generates images based on a regular breathing pattern and can...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/11/3597

    authors: Mishra P,St James S,Segars WP,Berbeco RI,Lewis JH

    更新日期:2012-06-07 00:00:00

  • Super-resolution reconstruction of 4D-CT lung data via patch-based low-rank matrix reconstruction.

    abstract::Lung 4D computed tomography (4D-CT), which is a time-resolved CT data acquisition, performs an important role in explicitly including respiratory motion in treatment planning and delivery. However, the radiation dose is usually reduced at the expense of inter-slice spatial resolution to minimize radiation-related heal...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa8a48

    authors: Fang S,Wang H,Liu Y,Zhang M,Yang W,Feng Q,Chen W,Zhang Y

    更新日期:2017-10-03 00:00:00

  • A study of potential numerical pitfalls in GPU-based Monte Carlo dose calculation.

    abstract::The purpose of this study was to evaluate the impact of numerical errors caused by the floating point representation of real numbers in a GPU-based Monte Carlo code used for dose calculation in radiation oncology, and to identify situations where this type of error arises. The program used as a benchmark was bGPUMCD. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/13/5007

    authors: Magnoux V,Ozell B,Bonenfant É,Després P

    更新日期:2015-07-07 00:00:00

  • Experimental determination of pCo perturbation factors for plane-parallel chambers.

    abstract::For plane-parallel chambers used in electron dosimetry, modern dosimetry protocols recommend a cross-calibration against a calibrated cylindrical chamber. The rationale for this is the unacceptably large (up to 3-4%) chamber-to-chamber variations of the perturbation factors (pwall)Co, which have been reported for plan...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,多中心研究

    doi:10.1088/0031-9155/52/23/026

    authors: Kapsch RP,Bruggmoser G,Christ G,Dohm OS,Hartmann GH,Schüle E

    更新日期:2007-12-07 00:00:00

  • Modeling late rectal toxicities based on a parameterized representation of the 3D dose distribution.

    abstract::Many models exist for predicting toxicities based on dose-volume histograms (DVHs) or dose-surface histograms (DSHs). This approach has several drawbacks as firstly the reduction of the dose distribution to a histogram results in the loss of spatial information and secondly the bins of the histograms are highly correl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/7/013

    authors: Buettner F,Gulliford SL,Webb S,Partridge M

    更新日期:2011-04-07 00:00:00

  • Hysteresis heating for the treatment of tumours.

    abstract::A method is described whereby, utilising a biocompatible magnetic glass-ceramic material, effective hysteresis heating in living tissue was accomplished. Initial experiments on mice showed that a significant heating effect can be obtained in the ceramic-impregnated regions. An analysis is also given for the projected ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/5/001

    authors: Borrelli NF,Luderer AA,Panzarino JN

    更新日期:1984-05-01 00:00:00

  • A Monte Carlo investigation of dual-energy-window scatter correction for volume-of-interest quantification in 99Tcm SPECT.

    abstract::Using Monte Carlo simulation of 99Tcm single-photon-emission computed tomography (SPECT), we investigate the effects of tissue-background activity, tumour location, patient size, uncertainty of energy windows, and definition of tumour region on the accuracy of quantification. The dual-energy-window method of correctio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/1/015

    authors: Luo JQ,Koral KF,Ljungberg M,Floyd CE Jr,Jaszczak RJ

    更新日期:1995-01-01 00:00:00

  • Evaluation of inverse methods and head models for EEG source localization using a human skull phantom.

    abstract::We used a real-skull phantom head to investigate the performances of representative methods for EEG source localization when considering various head models. We describe several experiments using a montage with current sources located at multiple positions and orientations inside a human skull filled with a conductive...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/1/306

    authors: Baillet S,Riera JJ,Marin G,Mangin JF,Aubert J,Garnero L

    更新日期:2001-01-01 00:00:00

  • A promising new mechanism of ionizing radiation detection for positron emission tomography: modulation of optical properties.

    abstract::Using conventional scintillation detection, the fundamental limit in positron emission tomography (PET) time resolution is strongly dependent on the inherent temporal variances generated during the scintillation process, yielding an intrinsic physical limit for the coincidence time resolution of around 100 ps. On the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/21/7600

    authors: Tao L,Daghighian HM,Levin CS

    更新日期:2016-11-07 00:00:00

  • Near real-time automated dose restoration in IMPT to compensate for daily tissue density variations in prostate cancer.

    abstract::Proton therapy is very sensitive to daily density changes along the pencil beam paths. The purpose of this study is to develop and evaluate an automated method for adaptation of IMPT plans to compensate for these daily tissue density variations. A two-step restoration method for 'densities-of-the-day' was created: (1)...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5c12

    authors: Jagt T,Breedveld S,van de Water S,Heijmen B,Hoogeman M

    更新日期:2017-06-07 00:00:00

  • Fuzzy clustering-based segmented attenuation correction in whole-body PET imaging.

    abstract::Segmented attenuation correction is now a widely accepted technique to reduce noise propagation from transmission scanning in positron emission tomography (PET). In this paper, we present a new method for segmenting transmission images in whole-body scanning. This reduces the noise in the correction maps while still c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/7/310

    authors: Zaidi H,Diaz-Gomez M,Boudraa A,Slosman DO

    更新日期:2002-04-07 00:00:00

  • Introducing the Jacobian-volume-histogram of deforming organs: application to parotid shrinkage evaluation.

    abstract::The Jacobian of the deformation field of elastic registration between images taken during radiotherapy is a measure of inter-fraction local deformation. The histogram of the Jacobian values (Jac) within an organ was introduced (JVH-Jacobian-volume-histogram) and first applied in quantifying parotid shrinkage. MVCTs of...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/11/008

    authors: Fiorino C,Maggiulli E,Broggi S,Liberini S,Cattaneo GM,Dell'oca I,Faggiano E,Di Muzio N,Calandrino R,Rizzo G

    更新日期:2011-06-07 00:00:00

  • Investigation of the performance of antiscatter grids: Monte Carlo simulation studies.

    abstract::Monte Carlo methods have been applied to the study of the performance of antiscatter grids in radiography. Photon histories for imaging with a 20 cm thick water phantom irradiated with an 80 kV x-ray spectrum were generated by Monte Carlo simulation. The scattering and absorption of the photons transmitted from the ph...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/27/6/002

    authors: Chan HP,Doi K

    更新日期:1982-06-01 00:00:00

  • Modeling silicon diode energy response factors for use in therapeutic photon beams.

    abstract::Silicon diodes have good spatial resolution, which makes them advantageous over ionization chambers for dosimetry in fields with high dose gradients. However, silicon diodes overrespond to low-energy photons, that are more abundant in scatter which increase with large fields and larger depths. We present a cavity-theo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/20/007

    authors: Eklund K,Ahnesjö A

    更新日期:2009-10-21 00:00:00

  • On the impact of longitudinal breathing motion randomness for tomotherapy delivery.

    abstract::The purpose of this study is to explain the unplanned longitudinal dose modulations that appear in helical tomotherapy (HT) dose distributions in the presence of irregular patient breathing. This explanation is developed by the use of longitudinal (1D) simulations of mock and surrogate data and tested with a fully 4D ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/18/001

    authors: Kissick MW,Flynn RT,Westerly DC,Hoban PW,Mo X,Soisson ET,McCall KC,Mackie TR,Jeraj R

    更新日期:2008-09-21 00:00:00

  • Design and performance of the micro-dose calibrator.

    abstract::A new class of dose calibrator called a micro-dose calibrator, designed to measure radioactivity rates in the range between 1 kBq up to 370 kBq, has been designed and an 8 NaI(Tl)/photo multiplier tube (PMT) module prototype built to evaluate its performance. The design of the micro-dose calibrator is based on the con...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aadb3b

    authors: Adler S,Choyke P

    更新日期:2018-09-10 00:00:00

  • A small animal holding fixture system with positional reproducibility for longitudinal multimodal imaging.

    abstract::This study presents a combined small animal holding fixture system, termed a 'bridge capsule', which provides for small animal re-fixation with positional reproducibility. This system comprises separate holding fixtures for the head and lower body and a connecting part to a gas anesthesia system. A mouse is fixed in p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/14/011

    authors: Kokuryo D,Kimura Y,Obata T,Yamaya T,Kawamura K,Zhang MR,Kanno I,Aoki I

    更新日期:2010-07-21 00:00:00

  • Exploiting flow to control the in vitro spatiotemporal distribution of microbubble-seeded acoustic cavitation activity in ultrasound therapy.

    abstract::Focused ultrasound and microbubbles have been extensively used to generate therapeutic bioeffects. Despite encouraging in vivo results, there remains poor control of the magnitude and spatial distribution of these bioeffects due to the limited ability of conventional pulse shapes and sequences to control cavitation dy...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/22/6941

    authors: Pouliopoulos AN,Bonaccorsi S,Choi JJ

    更新日期:2014-11-21 00:00:00

  • Beam data measurements for dynamic wedges on Varian 600C (6 MV) and 2100C (6 and 10 MV) linear accelerators.

    abstract::The measurement of beam data for dynamic wedge dosimetry requires the integration of radiation dose at points across the radiation field during the dose delivery. The different measurement techniques required when using a linear diode array to measure beam profiles and when using ionization chambers to measure depth d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/3/005

    authors: Bidmead AM,Garton AJ,Childs PJ

    更新日期:1995-03-01 00:00:00

  • Optimization of attenuation correction for positron emission tomography studies of thorax and pelvis using count-based transmission scans.

    abstract::The quality of thorax and pelvis transmission scans and therefore of attenuation correction in PET depends on patient thickness and transmission rod source strength. The purpose of the present study was to assess the feasibility of using count-based transmission scans, thereby guaranteeing more consistent image qualit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/4/n01

    authors: Boellaard R,van Lingen A,van Balen SC,Lammertsma AA

    更新日期:2004-02-21 00:00:00

  • In vivo dosimetry in the urethra using alanine/ESR during (192)Ir HDR brachytherapy of prostate cancer--a phantom study.

    abstract::A phantom study for dosimetry in the urethra using alanine/ESR during (192)Ir HDR brachytherapy of prostate cancer is presented. The measurement method of the secondary standard of the Physikalisch-Technische Bundesanstalt had to be slightly modified in order to be able to measure inside a Foley catheter. The absorbed...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/9/022

    authors: Anton M,Wagner D,Selbach HJ,Hackel T,Hermann RM,Hess CF,Vorwerk H

    更新日期:2009-05-07 00:00:00