Counting losses in multidetector radiation counters.

Abstract:

:We examined the reasons for the reduction in response of a multidetector radiation counting system when operated at high count-rates and established a convenient method of correction which is accurate to within +/- 1% up to 0-6 X 10(5) counts per second. In its application the method uses the observed count-rates from each detector at the time of measurement and previously determined values of critical time intervals of the electronic system. The detected signals establish these intervals in which further signals occurring within them are lost from the response. These further signals can also cause the loss of the signals establishing the intervals. The correction is of particular value when high-sensitivity whole-body counters are used to measure the activity of administered isotopes in metabolic studies.

journal_name

Phys Med Biol

authors

Oxby CB,Oldroyd B,Appleby DB

doi

10.1088/0031-9155/21/1/009

subject

Has Abstract

pub_date

1976-01-01 00:00:00

pages

104-16

issue

1

eissn

0031-9155

issn

1361-6560

journal_volume

21

pub_type

杂志文章
  • Photoluminescent thermometry based on europium-activated calcium sulphide.

    abstract::A photoluminescent thermometer, based on the transient emission response of a europium-activated calcium sulphide phosphor, is described in detail. This optical thermometry system has special advantages for temperature measurements in microwave and RF fields and potential application in electromagnetically induced cli...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/27/1/011

    authors: Samulski TV,Chopping PT,Haas B

    更新日期:1982-01-01 00:00:00

  • Kill painting of hypoxic tumors with multiple ion beams.

    abstract::We report on a novel method for simultaneous biological optimization of treatment plans for hypoxic tumors using multiple ion species. Our previously introduced kill painting approach, where the overall cell killing is optimized on biologically heterogeneous targets, was expanded with the capability of handling differ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aafe40

    authors: Sokol O,Krämer M,Hild S,Durante M,Scifoni E

    更新日期:2019-02-08 00:00:00

  • A spectral approach to ultrasonic scattering from human tissue: methods, objectives and backscattering measurements.

    abstract::The dearth of information on the physical processes involved in the propagation of ultrasound in tissue and the growing need for such information are discussed. The physical nature of the ultrasonic diagnostic process in considered in terms of a wave phenomenon and the limitations and advantages of frequency spectral ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/20/5/009

    authors: Chivers RC,Hill CR

    更新日期:1975-09-01 00:00:00

  • Investigation of the performance of antiscatter grids: Monte Carlo simulation studies.

    abstract::Monte Carlo methods have been applied to the study of the performance of antiscatter grids in radiography. Photon histories for imaging with a 20 cm thick water phantom irradiated with an 80 kV x-ray spectrum were generated by Monte Carlo simulation. The scattering and absorption of the photons transmitted from the ph...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/27/6/002

    authors: Chan HP,Doi K

    更新日期:1982-06-01 00:00:00

  • Prediction of dose-volume histograms in nasopharyngeal cancer IMRT using geometric and dosimetric information.

    abstract::A method using both patient geometric and dosimetric information was proposed to predict dose-volume histograms (DVHs) of organs at risk (OARs) for a nasopharyngeal cancer (NPC) intensity-modulated radiation therapy (IMRT) plan. A total of 106 nine-field IMRT NPC plans were used in this study. Twenty-six plans were ra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab50eb

    authors: Jiao SX,Chen LX,Zhu JH,Wang ML,Liu XW

    更新日期:2019-12-05 00:00:00

  • Non-uniform depth scanning for proton therapy systems employing active energy variation.

    abstract::In proton scanning systems that employ active energy variation for depth modulation, a switch of the particle energy might typically require 1-2 s. For plans comprising many energy slices, these seconds could sum up to a non-negligible fraction of the total treatment duration. We have applied the Nyquist-Shannon sampl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/9/N01

    authors: Kang JH,Wilkens JJ,Oelfke U

    更新日期:2008-05-07 00:00:00

  • New materials for dielectric simulation of tissues.

    abstract::Two novel materials have been developed to simulate the dielectric properties of human muscle and fat at 1000 MHz. These materials, which are based on ethanediol set with gelatine, are easily made and have good mechanical properties. The complex permittivity, epsilon *, of each material was measured with an open-ended...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/12/002

    authors: Robinson MP,Richardson MJ,Green JL,Preece AW

    更新日期:1991-12-01 00:00:00

  • A promising new mechanism of ionizing radiation detection for positron emission tomography: modulation of optical properties.

    abstract::Using conventional scintillation detection, the fundamental limit in positron emission tomography (PET) time resolution is strongly dependent on the inherent temporal variances generated during the scintillation process, yielding an intrinsic physical limit for the coincidence time resolution of around 100 ps. On the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/21/7600

    authors: Tao L,Daghighian HM,Levin CS

    更新日期:2016-11-07 00:00:00

  • Evaluation of robustness of maximum likelihood cone-beam CT reconstruction with total variation regularization.

    abstract::The objective of this paper is to evaluate an iterative maximum likelihood (ML) cone-beam computed tomography (CBCT) reconstruction with total variation (TV) regularization with respect to the robustness of the algorithm due to data inconsistencies. Three different and (for clinical application) typical classes of err...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/19/5955

    authors: Stsepankou D,Arns A,Ng SK,Zygmanski P,Hesser J

    更新日期:2012-10-07 00:00:00

  • Survey of numerical electrostimulation models.

    abstract::This paper evaluates results of a survey of electrostimulation models of myelinated nerve. Participants were asked to determine thresholds of excitation for 18 cases involving different characteristics of the neuron, the stimulation waveform, and the electrode arrangement. Responses were received from 7 investigators ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/12/4346

    authors: Reilly JP

    更新日期:2016-06-21 00:00:00

  • Dual energy CT using slow kVp switching acquisition and prior image constrained compressed sensing.

    abstract::Dual energy computed tomography (DECT) is currently a subject of extensive investigation. DECT is currently implemented using either a dual source scanner with high and low kVp data acquired from separate sources or a single source scanner with both high and low kVp data acquired in an alternating manner. Both methods...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/21/005

    authors: Szczykutowicz TP,Chen GH

    更新日期:2010-11-07 00:00:00

  • Quantitative analysis of a micro array anode structured target for hard x-ray grating interferometry.

    abstract::Talbot-Lau interferometry (TLI) provides additional contrast modes for x-ray imaging that are complementary to conventional absorption radiography. TLI is particularly interesting because it is one of the few practical methods for realizing phase contrast with x-rays that is compatible with large-spot high power x-ray...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab6578

    authors: Zan G,Vine DJ,Yun W,Lewis SJY,Wang Q,Wang G

    更新日期:2020-02-04 00:00:00

  • Systematic variations in polymer gel dosimeter calibration due to container influence and deviations from water equivalence.

    abstract::There are a number of gel dosimeter calibration methods in contemporary usage. The present study is a detailed Monte Carlo investigation into the accuracy of several calibration techniques. Results show that for most arrangements the dose to gel accurately reflects the dose to water, with the most accurate method invo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/13/022

    authors: Taylor ML,Franich RD,Johnston PN,Millar RM,Trapp JV

    更新日期:2007-07-07 00:00:00

  • An analysis of the accuracy of magnetic resonance flip angle measurement methods.

    abstract::Several methods of flip angle mapping for magnetic resonance imaging have been proposed. We evaluated the accuracy of five methods of flip angle measurement in the presence of measurement noise. Our analysis was performed in a closed form by propagation of probability density functions (PDFs). The flip angle mapping m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/20/008

    authors: Morrell GR,Schabel MC

    更新日期:2010-10-21 00:00:00

  • Why should breast tumour detection go three dimensional?

    abstract::Although x-ray mammography is widely developed for breast tumour detection, it suffers from spatial superposition in its two-dimensional (2D) representation of a three-dimensional (3D) breast structure. Accordingly, 3D breast imaging, such as cone-beam computed tomography (CT), arises at the historic moment. In this p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/14/312

    authors: Chen Z,Ning R

    更新日期:2003-07-21 00:00:00

  • Improved method of in vivo respiratory-gated micro-CT imaging.

    abstract::The presence of motion artifacts is a typical problem in thoracic imaging. However, synchronizing the respiratory cycle with computed tomography (CT) image acquisition can reduce these artifacts. We currently employ a method of in vivo respiratory-gated micro-CT imaging for small laboratory animals (mice). This proced...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/17/023

    authors: Walters EB,Panda K,Bankson JA,Brown E,Cody DD

    更新日期:2004-09-07 00:00:00

  • The relevance of very low energy ions for heavy-ion therapy.

    abstract::Heavy-ion radiotherapy exploits the high biological effectiveness of localized energy deposition delivered by so-called Bragg-peak particles. Recent publications have challenged the established procedures to calculate biological effective dose distributions in treatment planning. They emphasize the importance of very ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/7/N03

    authors: Elsässer T,Gemmel A,Scholz M,Schardt D,Krämer M

    更新日期:2009-04-07 00:00:00

  • Effect of temperature on the optical properties of ex vivo human dermis and subdermis.

    abstract::The effect of temperature on the optical properties of human dermis and subdermis as a function of near-infrared wavelength has been studied between 25 degrees C and 40 degrees C. Measurements were performed ex vivo on a total of nine skin samples taken from the abdomen of three individuals. The results show a reprodu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/9/004

    authors: Laufer J,Simpson R,Kohl M,Essenpreis M,Cope M

    更新日期:1998-09-01 00:00:00

  • A comparison between the patella and the calcaneus using ultrasound velocity and attenuation as predictors of bone mineral density.

    abstract::The bone mineral density (BMD), ultrasound velocity (UV) and attenuation were examined in sixteen matched sets of human patellae and calcanei. For the sixteen calcanei, BMD was strongly correlated with all ultrasound parameters. Calcaneal UV appeared to be inferior to attenuation in the ability to predict BMD. For the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/10/008

    authors: Han SM,Davis J

    更新日期:1997-10-01 00:00:00

  • Fluence-to-dose conversion coefficients for neutrons and protons calculated using the PHITS code and ICRP/ICRU adult reference computational phantoms.

    abstract::The fluence to organ-dose and effective-dose conversion coefficients for neutrons and protons with energies up to 100 GeV was calculated using the PHITS code coupled to male and female adult reference computational phantoms, which are to be released as a common ICRP/ICRU publication. For the calculation, the radiation...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/7/009

    authors: Sato T,Endo A,Zankl M,Petoussi-Henss N,Niita K

    更新日期:2009-04-07 00:00:00

  • A 3D reconstruction algorithm for magneto-acoustic tomography with magnetic induction based on ultrasound transducer characteristics.

    abstract::In this study we present a three-dimensional (3D) reconstruction algorithm for magneto-acoustic tomography with magnetic induction (MAT-MI) based on the characteristics of the ultrasound transducer. The algorithm is investigated to solve the blur problem of the MAT-MI acoustic source image, which is caused by the ultr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/61/24/8762

    authors: Ma R,Zhou X,Zhang S,Yin T,Liu Z

    更新日期:2016-12-21 00:00:00

  • Characterization of the electromagnetic near-field absorption in layered biological tissue in the frequency range from 30 MHz to 6,000 MHz.

    abstract::Currently, standards for the compliance testing of wireless devices are being extended to cover a wider frequency band and different usage patterns of mobile phones as well as of novel body-worn and handheld devices. As a consequence, not only the head but also strongly varying tissue distributions of the body are exp...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/19/014

    authors: Christ A,Samaras T,Klingenböck A,Kuster N

    更新日期:2006-10-07 00:00:00

  • Bilinear models for inter- and intra-patient variation of the prostate.

    abstract::We propose bilinear models for capturing and effectively decoupling the expected shape variations of an organ both across the patient population and within a specific patient. Bilinear models have been successfully introduced in other areas of computer vision, but they have rarely been used in medical imaging applicat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/13/010

    authors: Jeong Y,Radke RJ,Lovelock DM

    更新日期:2010-07-07 00:00:00

  • Automated stroke lesion segmentation in non-contrast CT scans using dense multi-path contextual generative adversarial network.

    abstract::Stroke lesion volume is a key radiologic measurement in assessing prognosis of acute ischemic stroke (AIS) patients. The aim of this paper is to develop an automated segmentation method for accurately segmenting follow-up ischemic and hemorrhagic lesion from multislice non-contrast CT (NCCT) volumes of AIS patients. T...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aba166

    authors: Kuang H,Menon BK,Qiu W

    更新日期:2020-11-05 00:00:00

  • Comparison study of temporal regularization methods for fully 5D reconstruction of cardiac gated dynamic SPECT.

    abstract::Temporal regularization plays a critical role in cardiac gated dynamic SPECT reconstruction, of which the goal is to obtain an image sequence from a single acquisition which simultaneously shows both cardiac motion and tracer distribution change over the course of imaging (termed 5D). In our recent work, we explored t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/17/5523

    authors: Niu X,Yang Y,King MA

    更新日期:2012-09-07 00:00:00

  • Kinetic parameter estimation from SPECT cone-beam projection measurements.

    abstract::Kinetic parameters are commonly estimated from dynamically acquired nuclear medicine data by first reconstructing a dynamic sequence of images and subsequently fitting the parameters to time-activity curves generated from regions of interest overlaid upon the image sequence. Biased estimates can result from images rec...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/4/024

    authors: Huesman RH,Reutter BW,Zeng GL,Gullberg GT

    更新日期:1998-04-01 00:00:00

  • Coverage-based constraints for IMRT optimization.

    abstract::Radiation therapy treatment planning requires an incorporation of uncertainties in order to guarantee an adequate irradiation of the tumor volumes. In current clinical practice, uncertainties are accounted for implicitly with an expansion of the target volume according to generic margin recipes. Alternatively, it is p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa8132

    authors: Mescher H,Ulrich S,Bangert M

    更新日期:2017-09-05 00:00:00

  • Feasibility of polymer gel-based measurements of radiation isocenter accuracy in magnetic fields.

    abstract::For conventional irradiation devices, the radiation isocenter accuracy is determined by star shot measurements on films. In magnetic resonance (MR)-guided radiotherapy devices, the results of this test may be altered by the magnetic field and the need to align the radiation and imaging isocenter may require a modifica...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aac228

    authors: Dorsch S,Mann P,Lang C,Haering P,Runz A,Karger CP

    更新日期:2018-05-29 00:00:00

  • Generalised use of contrast degradation and contrast improvement factors in diagnostic radiology. Application to vanishing contrast.

    abstract::Although field area and object thickness are important parameters in comparisons of techniques for optimal reduction of scattered radiation to the image, they are in practice seldom varied. For this reason, we suggest that contrast degradation (CDF) and contrast improvement (CIF) factors be more frequently used and ap...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/7/004

    authors: Carlsson GA,Carlsson CA,Nielsen B,Persliden J

    更新日期:1986-07-01 00:00:00

  • Reducing 4DCBCT imaging time and dose: the first implementation of variable gantry speed 4DCBCT on a linear accelerator.

    abstract::Four dimensional cone beam computed tomography (4DCBCT) uses a constant gantry speed and imaging frequency that are independent of the patient's breathing rate. Using a technique called respiratory motion guided 4DCBCT (RMG-4DCBCT), we have previously demonstrated that by varying the gantry speed and imaging frequency...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/62/11/4300

    authors: O'Brien RT,Stankovic U,Sonke JJ,Keall PJ

    更新日期:2017-06-07 00:00:00