A comparison between the patella and the calcaneus using ultrasound velocity and attenuation as predictors of bone mineral density.

Abstract:

:The bone mineral density (BMD), ultrasound velocity (UV) and attenuation were examined in sixteen matched sets of human patellae and calcanei. For the sixteen calcanei, BMD was strongly correlated with all ultrasound parameters. Calcaneal UV appeared to be inferior to attenuation in the ability to predict BMD. For the sixteen patellae, the average UV was found to be greater in the superior/inferior direction than in the anterior/posterior and medial/lateral directions. It was found that patella BMD was significantly correlated with each of three directional ultrasound velocities. The relationship between BMD and ultrasound attenuation parameters was not significant in the patella. A comparative study of the two different bone sets demonstrated that the BMDs of the patella and calcaneus were significantly correlated with each other. Ultrasound velocity of calcaneus, measured in the medial/lateral direction, was not significantly associated with any of three directional ultrasound velocities in the patella. Similarly, ultrasound attenuation parameters of calcaneus were not significantly correlated with those of patella. The present study also demonstrated evidence that when predicting BMDs at their respective sites using ultrasound, the calcaneus appeared to be superior to the patella.

journal_name

Phys Med Biol

authors

Han SM,Davis J

doi

10.1088/0031-9155/42/10/008

subject

Has Abstract

pub_date

1997-10-01 00:00:00

pages

1947-55

issue

10

eissn

0031-9155

issn

1361-6560

journal_volume

42

pub_type

杂志文章
  • Design, construction and use of a large-sample field-cycled PEDRI imager.

    abstract::The design, construction and use of a large-scale field-cycled proton-electron double-resonance imaging (FC-PEDRI) imager is described. The imager is based on a whole-body sized, vertical field, 59 mT permanent magnet. Field cycling is accomplished by the field compensation method, and uses a secondary, resistive magn...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/7/008

    authors: Lurie DJ,Foster MA,Yeung D,Hutchison JM

    更新日期:1998-07-01 00:00:00

  • Simultaneous minimization of leaf travel distance and tongue-and-groove effect for segmental intensity-modulated radiation therapy.

    abstract::This paper introduces a method to simultaneously minimize the leaf travel distance and the tongue-and-groove effect for IMRT leaf sequences to be delivered in segmental mode. The basic idea is to add a large enough number of openings through cutting or splitting existing openings for those leaf pairs with openings few...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/23/009

    authors: Dai J,Que W

    更新日期:2004-12-07 00:00:00

  • Optimisation of the imaging and dosimetric characteristics of an electronic portal imaging device employing plastic scintillating fibres using Monte Carlo simulations.

    abstract::A Monte Carlo model of a novel electronic portal imaging device (EPID) has been developed using Geant4 and its performance for imaging and dosimetry applications in radiotherapy has been characterised. The EPID geometry is based on a physical prototype under ongoing investigation and comprises an array of plastic scin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/22/6827

    authors: Blake SJ,McNamara AL,Vial P,Holloway L,Kuncic Z

    更新日期:2014-11-21 00:00:00

  • Volumetric CT with sparse detector arrays (and application to Si-strip photon counters).

    abstract::Novel x-ray medical imaging sensors, such as photon counting detectors (PCDs) and large area CCD and CMOS cameras can involve irregular and/or sparse sampling of the detector plane. Application of such detectors to CT involves undersampling that is markedly different from the commonly considered case of sparse angular...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/1/90

    authors: Sisniega A,Zbijewski W,Stayman JW,Xu J,Taguchi K,Fredenberg E,Lundqvist M,Siewerdsen JH

    更新日期:2016-01-07 00:00:00

  • Percentile-specific computational phantoms constructed from ICRP mesh-type reference computational phantoms (MRCPs).

    abstract::Recently, the Task Group 103 of the International Commission on Radiological Protection (ICRP) has developed new mesh-type reference computational phantoms (MRCPs) for adult male and female. When compared to the current voxel-type reference computational phantoms in ICRP Publication 110, the MRCPs have several advanta...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aafcdb

    authors: Lee H,Yeom YS,Nguyen TT,Choi C,Han H,Shin B,Zhang X,Kim CH,Chung BS,Zankl M

    更新日期:2019-02-05 00:00:00

  • The Monte Carlo calculation of integral radiation dose in xeromammography.

    abstract::A Monte Carlo computer program has been developed for the computation of integral radiation dose to the breast in xeromammography. The results are given in terms of the integral dose per unit area of the breast per unit incident exposure. The calculations have been made for monoenergetic incident photons and the resul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/1/003

    authors: Dance DR

    更新日期:1980-01-01 00:00:00

  • Fluence-to-dose conversion coefficients for neutrons and protons calculated using the PHITS code and ICRP/ICRU adult reference computational phantoms.

    abstract::The fluence to organ-dose and effective-dose conversion coefficients for neutrons and protons with energies up to 100 GeV was calculated using the PHITS code coupled to male and female adult reference computational phantoms, which are to be released as a common ICRP/ICRU publication. For the calculation, the radiation...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/7/009

    authors: Sato T,Endo A,Zankl M,Petoussi-Henss N,Niita K

    更新日期:2009-04-07 00:00:00

  • Improving SAR estimations in MRI using subject-specific models.

    abstract::To monitor and strategically control energy deposition in magnetic resonance imaging (MRI), measured as a specific absorption rate (SAR), numerical methods using generic human models have been employed to estimate worst-case values. Radiofrequency (RF) sequences are therefore often designed conservatively with large s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/24/8153

    authors: Jin J,Liu F,Weber E,Crozier S

    更新日期:2012-12-21 00:00:00

  • Radiobiological aspects of supralinear photographic emulsions.

    abstract::Nuclear emulsions of the Ilford K series, exposed to X-rays from 15 to 150 kVp and systematically underdeveloped, exhibit supralinear blackness--exposure curves ranging from 1- to 4-hit in character, and whose shape is the same at all excitation voltages. Processing can be so adjusted that the curve shape is well repr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/23/6/007

    authors: Katz R,Pennington EC

    更新日期:1978-11-01 00:00:00

  • Monte Carlo calculation of VMAT and helical tomotherapy dose distributions for lung stereotactic treatments with intra-fraction motion.

    abstract::The aim of this study is to calculate realistic dose distributions that include the continuous deformation of organs and continuous motion of machine using 4D Monte Carlo methods for both volumetric modulated arc therapy and helical tomotherapy treatments. As part of a previous study, we presented a method to perform ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/9/2807

    authors: Belec J,Clark BG

    更新日期:2013-05-07 00:00:00

  • CT reconstruction algorithm for a dental panoramic x-ray unit.

    abstract::A variable Jacobian and weighted backprojection algorithm, used for medical CT, was adapted to perform CT reconstructions on data obtained with a dental panoramic x-ray unit. A detector array, fitted to the unit for the purpose of acquiring digital panoramic radiographs, was used to collect the data. Compensations wer...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/12/001

    authors: Lee MD,Waggener RG,McDavid WD,Dove SB,Welander U,Tronje G

    更新日期:1992-12-01 00:00:00

  • Evaluation of a shock wave induced cavitation activity both in vitro and in vivo.

    abstract::This study evaluated the cavitation activity induced by shock wave (SW) pulses, both in vitro and in vivo, based on the area measurements of echogenic regions observed in B-mode ultrasound images. Residual cavitation bubble clouds induced by SW pulses were detected as echogenic regions in B-mode images. The temporal e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/19/014

    authors: Tu J,Matula TJ,Bailey MR,Crum LA

    更新日期:2007-10-07 00:00:00

  • Ionization chamber correction factors for MR-linacs.

    abstract::Previously, readings of air-filled ionization chambers have been described as being influenced by magnetic fields. To use these chambers for dosimetry in magnetic resonance guided radiotherapy (MRgRT), this effect must be taken into account by introducing a correction factor k B. The purpose of this study is to system...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aac4f2

    authors: Pojtinger S,Dohm OS,Kapsch RP,Thorwarth D

    更新日期:2018-06-07 00:00:00

  • Energy and spatial distribution of multiple order Compton scatter in SPECT: a Monte Carlo investigation.

    abstract::Energy and spatial projection distributions were simulated for gamma camera imaging of multiple order Compton scattered photons. SPECT imaging of a line source of radioactivity located in a water filled cylindrical phantom was modelled using Monte Carlo techniques. Photon trajectories were followed from emission to de...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/10/005

    authors: Floyd CE,Jaszczak RJ,Harris CC,Coleman RE

    更新日期:1984-10-01 00:00:00

  • Applicators for generating ultrasound-induced hyperthermia in neoplastic tumours and for use in ultrasound physiotherapy.

    abstract::Ultrasound in the low megahertz frequency range is used by physiotherapists to treat a variety of conditions. The treatments reduce swelling, reduce pain and increase movement at joints. Ultrasound is now also beginning to be used to treat malignant tumours. The tumours are heated to temperatures between 42 degrees an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/11/019

    authors: Quan KM,Shiran M,Watmough DJ

    更新日期:1989-11-01 00:00:00

  • Dose effect of guidewire position in intravascular brachytherapy.

    abstract::It has been reported that the dose effects of metallic guidewires are significant in intravascular brachytherapy (IVBT) using a beta source. The purpose of this work is to investigate the dependence of these dose effects on guidewire position. The EGS4 Monte Carlo codes were used to perform the dose calculations for t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/10/309

    authors: Shih R,Hsu WL,Li XA

    更新日期:2002-05-21 00:00:00

  • Multiline 3D beamforming using micro-beamformed datasets for pediatric transesophageal echocardiography.

    abstract::Until now, no matrix transducer has been realized for 3D transesophageal echocardiography (TEE) in pediatric patients. In 3D TEE with a matrix transducer, the biggest challenges are to connect a large number of elements to a standard ultrasound system, and to achieve a high volume rate (>200 Hz). To address these issu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aab45e

    authors: Bera D,Raghunathan SB,Chen C,Chen Z,Pertijs MAP,Verweij MD,Daeichin V,Vos HJ,van der Steen AFW,de Jong N,Bosch JG

    更新日期:2018-03-29 00:00:00

  • A finite element method for the determination of the relative response of ionization chambers in MR-linacs: simulation and experimental validation up to 1.5 T.

    abstract::In magnetic resonance (MR) guided radiotherapy, the magnetic field-dependent change in the dose response of ionization chambers is typically included by means of a correction factor [Formula: see text]. This factor can be determined experimentally or calculated by means of Monte Carlo (MC) simulations. To date, a smal...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2837

    authors: Pojtinger S,Kapsch RP,Dohm OS,Thorwarth D

    更新日期:2019-07-04 00:00:00

  • Influence of initial electron beam characteristics on monte carlo calculated absorbed dose distributions for linear accelerator electron beams.

    abstract::The least known parameters in a Monte Carlo simulation of a linear accelerator treatment head are often the properties of the initial electron beam directed onto the exit vacuum window. Several initial beams with different spatial fluence distributions, angular divergences and energy spectra have been transported thro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/22/308

    authors: Björk P,Knöös T,Nilsson P

    更新日期:2002-11-21 00:00:00

  • Development and evaluation of a deep learning based artificial intelligence for automatic identification of gold fiducial markers in an MRI-only prostate radiotherapy workflow.

    abstract::Identification of prostate gold fiducial markers in magnetic resonance imaging (MRI) images is challenging when CT images are not available, due to misclassifications from intra-prostatic calcifications. It is also a time consuming task and automated identification methods have been suggested as an improvement for bot...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abb0f9

    authors: Gustafsson CJ,Swärd J,Adalbjörnsson SI,Jakobsson A,Olsson LE

    更新日期:2020-11-12 00:00:00

  • The physics of red cell sedimentation.

    abstract::Blood was withdrawn from the ante-cubital vein of five normal volunteers and the erythrocytes were washed and resuspended in isotonic saline. The rate of descent of the erythrocyte-saline boundary was measured every hour for a period of at least 4 h for different suspended cell concentrations. The velocity of this bou...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/2/002

    authors: Smallwood RH,Tindale WB,Trowbridge EA

    更新日期:1985-02-01 00:00:00

  • Self-adaptive ultrasonic beam amplifiers: application to transcostal shock wave therapy.

    abstract::Ultrasound shock wave therapy is increasingly used for non-invasive surgery. It requires the focusing of very high pressure amplitude in precisely controlled focal spots. In transcostal therapy of the heart or the liver, the high impedance mismatch between the bones and surrounding tissues gives rise to strong aberrat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad9b5

    authors: Robin J,Simon A,Arnal B,Tanter M,Pernot M

    更新日期:2018-09-06 00:00:00

  • Commissioning of pencil beam and Monte Carlo dose engines for non-isocentric treatments in scanned proton beam therapy.

    abstract::This work describes the dosimetric commissioning of the treatment planning system (TPS) RayStation v6.1 from RaySearch Laboratories (Stockholm, Sweden) for a synchrotron-based scanned proton beam delivery with isocentric and non-isocentric setups at MedAustron. Focus was on the comparison of the pencil beam (PBv4.1) a...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab3557

    authors: Carlino A,Böhlen T,Vatnitsky S,Grevillot L,Osorio J,Dreindl R,Palmans H,Stock M,Kragl G

    更新日期:2019-08-28 00:00:00

  • Report of the IPSM working party on low- and medium-energy x-ray dosimetry. Institute of Physical Sciences in Medicine.

    abstract::New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the IAEA in 1987. These are not considered to possess sufficient support from other s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/8/001

    authors:

    更新日期:1991-08-01 00:00:00

  • Analytical modeling of relative luminescence efficiency of Al2O3:C optically stimulated luminescence detectors exposed to high-energy heavy charged particles.

    abstract::The objective of this work is to test analytical models to calculate the luminescence efficiency of Al(2)O(3):C optically stimulated luminescence detectors (OSLDs) exposed to heavy charged particles with energies relevant to space dosimetry and particle therapy. We used the track structure model to obtain an analytica...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/2/437

    authors: Sawakuchi GO,Yukihara EG

    更新日期:2012-01-21 00:00:00

  • Evaluation of quantitative planar 90Y bremsstrahlung whole-body imaging.

    abstract::With high-dose administration of (90)Y labeled antibodies, it is possible to image (90)Y without an admixture of (111)In. We have earlier shown that it is possible to perform quantitative (90)Y bremsstrahlung SPECT for dosimetry purposes with reasonable accuracy. However, whole-body (WB) activity quantification with t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/19/014

    authors: Minarik D,Ljungberg M,Segars P,Gleisner KS

    更新日期:2009-10-07 00:00:00

  • Proton beam monitor chamber calibration.

    abstract::The first goal of this paper is to clarify the reference conditions for the reference dosimetry of clinical proton beams. A clear distinction is made between proton beam delivery systems which should be calibrated with a spread-out Bragg peak field and those that should be calibrated with a (pseudo-)monoenergetic prot...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/17/4961

    authors: Gomà C,Lorentini S,Meer D,Safai S

    更新日期:2014-09-07 00:00:00

  • Towards clinical application: prompt gamma imaging of passively scattered proton fields with a knife-edge slit camera.

    abstract::Prompt γ-ray imaging with a knife-edge shaped slit camera provides the possibility of verifying proton beam range in tumor therapy. Dedicated experiments regarding the characterization of the camera system have been performed previously. Now, we aim at implementing the prototype into clinical application of monitoring...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/22/7881

    authors: Priegnitz M,Barczyk S,Nenoff L,Golnik C,Keitz I,Werner T,Mein S,Smeets J,Vander Stappen F,Janssens G,Hotoiu L,Fiedler F,Prieels D,Enghardt W,Pausch G,Richter C

    更新日期:2016-11-21 00:00:00

  • Preliminary evaluation of biomechanical modeling of lung deflation during minimally invasive surgery using pneumothorax computed tomography scans.

    abstract::During minimally invasive surgery (MIS) for lung tumor resection, the localization of tumors or nodules relies on visual inspection of the deflated lung on intra-procedural video. For patients with tumors or nodules located deeper in the lung, this localization is not possible without prior invasive marking techniques...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abb6ba

    authors: Lesage AJ,Rajaram R,Tam AL,Rigaud BS,Brock KK,Rice DC,Cazoulat G

    更新日期:2020-09-09 00:00:00

  • FDTD calculations of the whole-body averaged SAR in an anatomically realistic voxel model of the human body from 1 MHz to 1 GHz.

    abstract::This paper presents finite-difference time-domain (FDTD) calculations of the whole-body averaged SAR in an anatomically realistic voxel model of the human body. This model, NORMAN, consists of approximately 9 million voxels, of 2 mm dimension in the adult phantom, segmented into 37 tissue types. SAR values are present...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/3/003

    authors: Dimbylow PJ

    更新日期:1997-03-01 00:00:00