Kill painting of hypoxic tumors with multiple ion beams.

Abstract:

:We report on a novel method for simultaneous biological optimization of treatment plans for hypoxic tumors using multiple ion species. Our previously introduced kill painting approach, where the overall cell killing is optimized on biologically heterogeneous targets, was expanded with the capability of handling different ion beams simultaneously. The current version (MIBO) of the research treatment planning system TRiP98 has now been augmented to handle 3D (voxel-by-voxel) target oxygenation data. We present a case of idealized geometries where this method can identify optimal combinations leading to an improved peak-to-entrance effective dose ratio. This is achieved by the redistribution of particle fluences, when the heavier ions are preferentially forwarded to hypoxic target areas, while the lighter ions deliver the remaining dose to its normoxic regions. Finally, we present an in silico skull base chordoma patient case study with a combination of 4He and 16O beams, demonstrating specific indications for its potential clinical application. In this particular case, the mean dose, received by the brainstem, was reduced by 3%-5% and by 10%-12% as compared to the pure 4He and 16O plans, respectively. The new method allows a full biological optimization of different ion beams, exploiting the capabilities of actively scanned ion beams of modern particle therapy centers. The possible experimental verification of the present approach at ion beam facilities disposing of fast ion switch is presented and discussed.

journal_name

Phys Med Biol

authors

Sokol O,Krämer M,Hild S,Durante M,Scifoni E

doi

10.1088/1361-6560/aafe40

subject

Has Abstract

pub_date

2019-02-08 00:00:00

pages

045008

issue

4

eissn

0031-9155

issn

1361-6560

journal_volume

64

pub_type

杂志文章
  • Simulation study to improve the performance of a whole-body PbF2 Cherenkov TOF-PET scanner.

    abstract::Using Cherenkov radiation in positron emission tomography (PET) has the potential to improve the time of flight (TOF) resolution and reduce the cost of detectors. In previous studies promising TOF results were achieved when lead fluoride (PbF2) crystals were used instead of a scintillator. In this work, a whole-body P...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab6f97

    authors: Consuegra D,Korpar S,Križan P,Pestotnik R,Razdevšek G,Dolenec R

    更新日期:2020-03-06 00:00:00

  • Novel adaptive beam-dependent margins for additional OAR sparing.

    abstract::Margins are employed in radiotherapy treatment planning to mitigate the dosimetric effects of geometric uncertainties for the clinical target volume (CTV). Unfortunately, whilst the use of margins can increase the probability that sufficient dose is delivered to the CTV, it can also result in delivering high dose of r...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aae658

    authors: Tsang HS,Kamerling CP,Ziegenhein P,Nill S,Oelfke U

    更新日期:2018-10-29 00:00:00

  • A model for the accurate computation of the lateral scattering of protons in water.

    abstract::A pencil beam model for the calculation of the lateral scattering in water of protons for any therapeutic energy and depth is presented. It is based on the full Molière theory, taking into account the energy loss and the effects of mixtures and compounds. Concerning the electromagnetic part, the model has no free para...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/4/N102

    authors: Bellinzona EV,Ciocca M,Embriaco A,Ferrari A,Fontana A,Mairani A,Parodi K,Rotondi A,Sala P,Tessonnier T

    更新日期:2016-02-21 00:00:00

  • Dosimetry for the MRI accelerator: the impact of a magnetic field on the response of a Farmer NE2571 ionization chamber.

    abstract::The UMC Utrecht is constructing a 1.5 T MRI scanner integrated with a linear accelerator (Lagendijk et al 2008 Radiother. Oncol. 86 25-9). The goal of this device is to facilitate soft-tissue contrast based image-guided radiotherapy, in order to escalate the dose to the tumour while sparing surrounding normal tissues....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/10/002

    authors: Meijsing I,Raaymakers BW,Raaijmakers AJ,Kok JG,Hogeweg L,Liu B,Lagendijk JJ

    更新日期:2009-05-21 00:00:00

  • A depth-encoding PET detector for high resolution PET using 1 mm SiPMs.

    abstract::A dual-ended readout PET detector based on two Hamamatsu 16 × 16 arrays of 1 × 1 mm2 SiPMs coupled to both ends of a 25 × 25 array of 0.69 × 0.69 × 20 mm3 polished LYSOs was evaluated in terms of flood histogram, energy resolution, timing resolution, and DOI resolution. The SiPM arrays have a pitch size of 1.2 mm. Eac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9fc9

    authors: Du J,Bai X,Cherry SR

    更新日期:2020-08-19 00:00:00

  • Optimization of MAGIC gel formulation for three-dimensional radiation therapy dosimetry.

    abstract::Polymer gel dosimetry aims to provide three-dimensional images of radiation therapy dose distributions in irradiated aqueous gels. The first gels required manufacture in an oxygen-free environment, but later the MAGIC formulation was introduced, which could be made in normal atmospheric conditions. Here we report our ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/10/N03

    authors: Luci JJ,Whitney HM,Gore JC

    更新日期:2007-05-21 00:00:00

  • Image reconstruction.

    abstract::We give an overview of the role of Physics in Medicine and Biology in the development of tomographic reconstruction algorithms. We focus on imaging modalities involving ionizing radiation, CT, PET and SPECT, and cover a wide spectrum of reconstruction problems, starting with classical 2D tomography in the 1970s up to ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/51/13/R09

    authors: Defrise M,Gullberg GT

    更新日期:2006-07-07 00:00:00

  • Pulse shape discrimination and classification methods for continuous depth of interaction encoding PET detectors.

    abstract::In previous work we demonstrated the potential of positron emission tomography (PET) detectors with depth-of-interaction (DOI) encoding capability based on phosphor-coated crystals. A DOI resolution of 8 mm full-width at half-maximum was obtained for 20 mm long scintillator crystals using a delayed charge integration ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/20/6571

    authors: Roncali E,Phipps JE,Marcu L,Cherry SR

    更新日期:2012-10-21 00:00:00

  • Kernel-based curve-fitting method with spatial regularization for generation of parametric images in dynamic PET.

    abstract::Due to high levels of noise in pixel-wise time-activity curves, the indirect method that generates kinetic parametric images from dynamic positron emission tomography (PET) images often results in poor parametric image quality. We have demonstrated that the quality of parametric images can be improved by denoising dyn...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abb1d8

    authors: Huang HM

    更新日期:2020-11-17 00:00:00

  • Effect of dominant features on neural network performance in the classification of mammographic lesions.

    abstract::Two different classifiers, an artificial neural network (ANN) and a hybrid system (one step rule-based method followed by an artificial neural network) have been investigated to merge computer-extracted features in the task of differentiating between malignant and benign masses. A database consisting of 65 cases (38 m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/10/315

    authors: Huo Z,Giger ML,Metz CE

    更新日期:1999-10-01 00:00:00

  • The effects of renal variation upon measurements of perfusion and leakage volume in breast tumours.

    abstract::Dynamic contrast enhanced MRI (DCE-MRI) and pharmacokinetic models have been used to measure tumour permeability (K(trans)) and leakage volume (ve) in numerous studies. The construction of pharmacokinetic models describing such tissue properties relies on defining the blood plasma concentration of contrast agent with ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/10/014

    authors: Ahearn TS,Staff RT,Redpath TW,Semple SI

    更新日期:2004-05-21 00:00:00

  • Thermoluminescent response and relative efficiency of TLD-100 exposed to low-energy x-rays.

    abstract::The dose-response of LiF:Mg,Ti (TLD-100) exposed to 15 and 35 kVp (8.0 +/- 0.1 and 8.1 +/- 0.1 keV effective energy respectively) x-rays and 60Co gamma-rays has been measured in the dose interval from (1.2-5.4) x 10(3) Gy for x-rays, and from 0.14 to 850 Gy for gamma-rays. In both cases the total TL signal and glow cu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/8/006

    authors: Gamboa-deBuen I,Buenfil AE,Ruiz CG,Rodríguez-Villafuerte M,Flores A,Brandan ME

    更新日期:1998-08-01 00:00:00

  • In vivo cerebrovascular measurement combining diffuse near-infrared absorption and correlation spectroscopies.

    abstract::We combine two near-infrared diffuse optical techniques to study variations of blood flow, haemoglobin concentration, and blood oxygen saturation in the functioning rat brain. Diffuse correlation spectroscopy (or flowmetry) monitors changes in the cerebral blood flow, without the use of the principles of tracer cleara...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/8/302

    authors: Cheung C,Culver JP,Takahashi K,Greenberg JH,Yodh AG

    更新日期:2001-08-01 00:00:00

  • Effect of inter-crystal scatter on estimation methods for random coincidences and subsequent correction.

    abstract::Random coincidences can contribute substantially to the background in positron emission tomography (PET). Several estimation methods are being used for correcting them. The goal of this study was to investigate the validity of techniques for random coincidence estimation, with various low-energy thresholds (LETs). Sim...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/9/012

    authors: Torres-Espallardo I,Rafecas M,Spanoudaki V,McElroy DP,Ziegler SI

    更新日期:2008-05-07 00:00:00

  • Modeling localized delivery of Doxorubicin to the brain following focused ultrasound enhanced blood-brain barrier permeability.

    abstract::Doxorubicin (Dox) is a well-established chemotherapeutic agent, however it has limited efficacy in treating brain malignancies due to the presence of the blood-brain barrier (BBB). Recent preclinical studies have demonstrated that focused ultrasound induced BBB disruption (BBBD) enables efficient delivery of Dox to th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/20/5987

    authors: Nhan T,Burgess A,Lilge L,Hynynen K

    更新日期:2014-10-21 00:00:00

  • The induction of hyperthermia by ultrasound; its value and associated problems: II. Scanned-plane transducer.

    abstract::A system is described in which large superficial areas of tissue may be heated using a single plane ultrasonic transducer scanned in a raster fashion. The shape of the heated area is determined by the movement of a microswitch which is activated when it strikes the rigid edge of a hole of the required shape cut in a p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/12/006

    authors: ter Haar G,Hopewell JW

    更新日期:1985-12-01 00:00:00

  • Quenching correction for volumetric scintillation dosimetry of proton beams.

    abstract::Volumetric scintillation dosimetry has the potential to provide fast, high-resolution, three-dimensional radiation dosimetry. However, scintillators exhibit a nonlinear response at the high linear energy transfer (LET) values characteristic of proton Bragg peaks. The purpose of this study was to develop a quenching co...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/2/261

    authors: Robertson D,Mirkovic D,Sahoo N,Beddar S

    更新日期:2013-01-21 00:00:00

  • Characterization of diffraction-enhanced imaging contrast in breast cancer.

    abstract::Diffraction-enhanced imaging (DEI) is a new x-ray imaging modality that has been shown to enhance contrast between normal and cancerous breast tissues. In this study, diffraction-enhanced imaging in computed tomography (DEI-CT) mode was used to quantitatively characterize the refraction contrasts of the organized stru...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/10/019

    authors: Kao T,Connor D,Dilmanian FA,Faulconer L,Liu T,Parham C,Pisano ED,Zhong Z

    更新日期:2009-05-21 00:00:00

  • A method for energy window optimization for quantitative tasks that includes the effects of model-mismatch on bias: application to Y-90 bremsstrahlung SPECT imaging.

    abstract::Quantitative Yttrium-90 ((90)Y) bremsstrahlung single photon emission computed tomography (SPECT) imaging has shown great potential to provide reliable estimates of (90)Y activity distribution for targeted radionuclide therapy dosimetry applications. One factor that potentially affects the reliability of the activity ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/12/3711

    authors: Rong X,Du Y,Frey EC

    更新日期:2012-06-21 00:00:00

  • Effects of tissue mechanical and acoustic anisotropies on the performance of a cross-correlation-based ultrasound strain imaging method.

    abstract::The anisotropic mechanical properties (mechanical anisotropy) and view-dependent ultrasonic backscattering (acoustic anisotropy) of striated muscle due to the underlying myofiber arrangement have been well documented, but whether they impact on ultrasound strain imaging (USI) techniques remains unclear. The aim of thi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa530b

    authors: Li H,Lee WN

    更新日期:2017-02-21 00:00:00

  • Radiofrequency and microwave dielectric properties of aqueous cryoprotectant agents: dimethyl sulphoxide and 2,3-butanediol.

    abstract::Earlier work on the dielectric properties of cryoprotectant agents is extended using a modified measuring cell and method of data reduction yielding results more efficiently over a temperature range from -75 to +25 degrees C at frequencies from 27 MHz to 3 GHz. Dimethyl sulphoxide and butanediol are investigated at lo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/10/011

    authors: Evans S,bin Azeman A

    更新日期:1998-10-01 00:00:00

  • An in vivo method of measurement of the mechanical properties of vascular prostheses: the mechanical properties of saphenous vein bypass grafts.

    abstract::It seems likely that long term patency of small bore vascular prostheses is dependent upon, among other things, the mechanical properties of their walls. Arteries are visco-elastic but there is no accurate method of measuring the visco-elasticity of arterial substitutes in vivo. The most successful vascular substitute...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/28/9/006

    authors: Chapman BL,Charlesworth D

    更新日期:1983-09-01 00:00:00

  • Four-dimensional Monte Carlo simulation of time-dependent geometries.

    abstract::Dynamic radiation therapy techniques require that the treatment head setup varies in time and space during dose delivery. Examples are leaf motion in intensity modulated x-ray therapy, modulator wheel rotation in conventional proton therapy and variable magnet settings in proton beam scanning. Consequently, for Monte ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/6/n03

    authors: Paganetti H

    更新日期:2004-03-21 00:00:00

  • Comments on 'Calculation of water equivalent thickness of materials of arbitrary density, elemental composition and thickness in proton beam irradiation'.

    abstract::We comment on a previous article by Zhang and Newhauser (2009 Phys. Med. Biol. 54 1383-95) which presents several approximate ways of computing the water equivalent of an arbitrary degrader. First, we present a simple exact method which depends only on the range-energy relation of water and of the degrader material. S...

    journal_title:Physics in medicine and biology

    pub_type: 评论,信件

    doi:10.1088/0031-9155/55/9/L01

    authors: Gottschalk B

    更新日期:2010-05-07 00:00:00

  • UWB pulse propagation into human tissues.

    abstract::In this paper the propagation of a UWB pulse into a layered model of the human body is studied to characterize absorption and reflection of the UWB signal due to the different body tissues. Several time behaviours for the incident UWB pulse are considered and compared with reference to the feasibility of breath and he...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/24/8689

    authors: Cavagnaro M,Pittella E,Pisa S

    更新日期:2013-12-21 00:00:00

  • Reducing 4DCBCT imaging time and dose: the first implementation of variable gantry speed 4DCBCT on a linear accelerator.

    abstract::Four dimensional cone beam computed tomography (4DCBCT) uses a constant gantry speed and imaging frequency that are independent of the patient's breathing rate. Using a technique called respiratory motion guided 4DCBCT (RMG-4DCBCT), we have previously demonstrated that by varying the gantry speed and imaging frequency...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/62/11/4300

    authors: O'Brien RT,Stankovic U,Sonke JJ,Keall PJ

    更新日期:2017-06-07 00:00:00

  • The modelling of biological systems in three dimensions using the time domain finite-difference method: I. The implementation of the model.

    abstract::A computer method has been developed which uses the time domain finite-difference (TDFD) algorithm to calculate the deposition of the electromagnetic (EM) field in three-dimensional biological models. This, the first of two papers, describes the algorithm and the computer programs developed. The method is demonstrated...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/11/006

    authors: Lau RW,Sheppard RJ

    更新日期:1986-11-01 00:00:00

  • Validation of the SimSET simulation package for modeling the Siemens Biograph mCT PET scanner.

    abstract::Monte Carlo simulation provides a valuable tool in performance assessment and optimization of system design parameters for PET scanners. SimSET is a popular Monte Carlo simulation toolkit that features fast simulation time, as well as variance reduction tools to further enhance computational efficiency. However, SimSE...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/3/N35

    authors: Poon JK,Dahlbom ML,Casey ME,Qi J,Cherry SR,Badawi RD

    更新日期:2015-02-07 00:00:00

  • Comparative efficiency of the multi-leaf collimator and variable-aperture collimator in intensity-modulated radiotherapy.

    abstract::The potential of the variable-aperture collimator (VAC) in intensity-modulated radiation therapy (IMRT) has been evaluated by comparing its performance with that of the multi-leaf collimator (MLC). This comparison used a decomposition algorithm to find the series of collimator segments that would treat a given intensi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/7/006

    authors: Anderson JW,Symonds-Tayler R,Hartmann G,Echner G,Lang C,Schlegel W,Webb S

    更新日期:2006-04-07 00:00:00

  • Image domain multi-material decomposition using single energy CT.

    abstract::Multi-material decomposition (MMD) technique decomposes the CT images into basis material images and has been promising in clinical practice for material composition quantification within the human body. MMD could be implemented using the image data acquired from spectral CT or its special case, dual-energy CT (DECT) ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab7503

    authors: Xue Y,Luo C,Jiang Y,Yang P,Hu X,Zhou Q,Wang J,Hu X,Sheng K,Niu T

    更新日期:2020-03-23 00:00:00