Validation of the SimSET simulation package for modeling the Siemens Biograph mCT PET scanner.

Abstract:

:Monte Carlo simulation provides a valuable tool in performance assessment and optimization of system design parameters for PET scanners. SimSET is a popular Monte Carlo simulation toolkit that features fast simulation time, as well as variance reduction tools to further enhance computational efficiency. However, SimSET has lacked the ability to simulate block detectors until its most recent release. Our goal is to validate new features of SimSET by developing a simulation model of the Siemens Biograph mCT PET scanner and comparing the results to a simulation model developed in the GATE simulation suite and to experimental results. We used the NEMA NU-2 2007 scatter fraction, count rates, and spatial resolution protocols to validate the SimSET simulation model and its new features. The SimSET model overestimated the experimental results of the count rate tests by 11-23% and the spatial resolution test by 13-28%, which is comparable to previous validation studies of other PET scanners in the literature. The difference between the SimSET and GATE simulation was approximately 4-8% for the count rate test and approximately 3-11% for the spatial resolution test. In terms of computational time, SimSET performed simulations approximately 11 times faster than GATE simulations. The new block detector model in SimSET offers a fast and reasonably accurate simulation toolkit for PET imaging applications.

journal_name

Phys Med Biol

authors

Poon JK,Dahlbom ML,Casey ME,Qi J,Cherry SR,Badawi RD

doi

10.1088/0031-9155/60/3/N35

subject

Has Abstract

pub_date

2015-02-07 00:00:00

pages

N35-45

issue

3

eissn

0031-9155

issn

1361-6560

journal_volume

60

pub_type

杂志文章
  • Investigation of the sag in linac secondary collimator and MLC carriage during arc deliveries.

    abstract::In modern radiotherapy, it is vitally important to monitor the performance of all linac components including the collimation system. In this study, a simple measurement method and accurate algorithm are introduced for investigation of the secondary and tertiary collimator sag during radiotherapy arc treatments. The me...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/12/N209

    authors: Rowshanfarzad P,Sabet M,O'Connor DJ,Greer PB

    更新日期:2012-06-21 00:00:00

  • Development of a globally optimised model of the cerebral arteries.

    abstract::The cerebral arteries are difficult to reproduce from first principles, featuring interwoven territories, and intricate layers of grey and white matter with differing metabolic demand. The aim of this study was to identify the ideal configuration of arteries required to sustain an entire brain hemisphere based on mini...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2479

    authors: Keelan J,Chung EML,Hague JP

    更新日期:2019-06-21 00:00:00

  • An integrated quality assurance phantom for frameless single-isocenter multitarget stereotactic radiosurgery.

    abstract::Brain stereotactic radiosurgery (SRS) treatments require multiple quality assurance (QA) procedures to ensure accurate and precise treatment delivery. As single-isocenter multitarget SRS treatments become more popular, the quantification of off-axis accuracy of the linear accelerator is crucial. In this study, a novel...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8534

    authors: Capaldi DPI,Skinner LB,Dubrowski P,Yu AS

    更新日期:2020-06-10 00:00:00

  • Significance of background optical properties, time-resolved information and optode arrangement in diffuse optical imaging of term neonates.

    abstract::The significance of accurate knowledge of background optical properties and time-resolved information in reconstructing images of hemodynamic changes in the neonatal brain from diffuse optical imaging data was studied using Monte Carlo (MC) simulation. A segmented anatomical magnetic resonance (MR) image and literatur...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/3/005

    authors: Heiskala J,Hiltunen P,Nissilä I

    更新日期:2009-02-07 00:00:00

  • An absorptiometry method for the determination of arterial blood concentration of injected iodinated contrast agent.

    abstract::A single photon absorptiometry method to measure the arterial concentration of injected iodinated contrast agent was developed. A prototype absorptiometry unit was built which consists of either a square or circular cross section acrylic (polymethylmethacrylate) cuvette connected to an arterial catheter at one end and...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/9/002

    authors: Yeung WT,Lee TY,Del Maestro RF,Kozak R,Bennett JD,Brown T

    更新日期:1992-09-01 00:00:00

  • Fast and exact Hessian computation for a class of nonlinear functions used in radiation therapy treatment planning.

    abstract::In nonlinear optimisation, using exact Hessian computations (full-Newton) hold superior convergence properties over quasi-Newton methods or gradient-based methods. However, for medium-scale problems, computing the Hessian can be computationally expensive and thus time-consuming. For solvers dedicated to a specific pro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab1e17

    authors: van Haveren R,Breedveld S

    更新日期:2019-08-14 00:00:00

  • 2D convolution kernels of ionization chambers used for photon-beam dosimetry in magnetic fields: the advantage of small over large chamber dimensions.

    abstract::This study aims at developing an optimization strategy for photon-beam dosimetry in magnetic fields using ionization chambers. Similar to the familiar case in the absence of a magnetic field, detectors should be selected under the criterion that their measured 2D signal profiles M(x,y) approximate the absorbed dose to...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aab50c

    authors: Looe HK,Delfs B,Poppinga D,Harder D,Poppe B

    更新日期:2018-03-29 00:00:00

  • A limited-angle CT reconstruction method based on anisotropic TV minimization.

    abstract::This paper presents a compressed sensing (CS)-inspired reconstruction method for limited-angle computed tomography (CT). Currently, CS-inspired CT reconstructions are often performed by minimizing the total variation (TV) of a CT image subject to data consistency. A key to obtaining high image quality is to optimize t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/7/2119

    authors: Chen Z,Jin X,Li L,Wang G

    更新日期:2013-04-07 00:00:00

  • MR-based keyhole SPECT for small animal imaging.

    abstract::The rationale for multi-modality imaging is to integrate the strengths of different imaging technologies while reducing the shortcomings of an individual modality. The work presented here proposes a limited-field-of-view (LFOV) SPECT reconstruction technique that can be implemented on a multi-modality MR/SPECT system ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/3/010

    authors: Lee KS,Roeck WW,Gullberg GT,Nalcioglu O

    更新日期:2011-02-07 00:00:00

  • Design of applicators for a 27 MHz multielectrode current source interstitial hyperthermia system; impedance matching and effective power.

    abstract::In interstitial heating one of the main requirements for achieving a certain elevated temperature in a tumour is that the effective power per applicator (Peff), i.e. the power which is actually deposited in the tissue, is sufficiently high. In this paper this requirement is discussed for the applicators of the 27 MHz ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/6/007

    authors: Kaatee RS,Crezee J,Kanis AP,Lagendijk JJ,Levendag PC,Visser AG

    更新日期:1997-06-01 00:00:00

  • CyberArc: a non-coplanar-arc optimization algorithm for CyberKnife.

    abstract::The goal of this study is to demonstrate the feasibility of a novel non-coplanar-arc optimization algorithm (CyberArc). This method aims to reduce the delivery time of conventional CyberKnife treatments by allowing for continuous beam delivery. CyberArc uses a 4 step optimization strategy, in which nodes, beams, and c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6f92

    authors: Kearney V,Cheung JP,McGuinness C,Solberg TD

    更新日期:2017-06-26 00:00:00

  • Electron depth-dose dependence on energy spectral quality.

    abstract::Electron depth-dose curves and spectra have been measured from an experimental accelerator on which both energy and spectral shape could be varied independently. The measurements were made at nominal energies of 6 and 12 MeV, with the energy spread (FWHM) varied from 1.7% to over 10% of average energy. Changes in dept...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/28/12/005

    authors: Johnsen SW,LaRiviere PD,Tanabe E

    更新日期:1983-12-01 00:00:00

  • A set cover approach to fast beam orientation optimization in intensity modulated radiation therapy for total marrow irradiation.

    abstract::The beam orientation optimization (BOO) problem in intensity modulated radiation therapy (IMRT) treatment planning is a nonlinear problem, and existing methods to obtain solutions to the BOO problem are time consuming due to the complex nature of the objective function and size of the solution space. These issues beco...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/17/014

    authors: Lee CH,Aleman DM,Sharpe MB

    更新日期:2011-09-07 00:00:00

  • Infrared and visible thermoluminescence signals of Tm-doped CaF2 measured by a semiconductor photodiode.

    abstract::A silicon semiconductor photodiode was used to measure the TL-signal of TLD-300 (CaF2:Tm) detectors irradiated with 60Co gamma rays and 226Ra alpha particles. The applied dose values varied from 0.12 to 14.3 Gy for gamma rays and from about 50 to 300 Gy for alpha particles. Because of the infrared sensitivity of the p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/33/12/006

    authors: Meissner P,Jacob M,Rassow J

    更新日期:1988-12-01 00:00:00

  • Accuracy of Monte Carlo photon transport simulation in characterizing brachytherapy dosimeter energy-response artefacts.

    abstract::Practical dosimeters in brachytherapy, such as thermoluminescent dosimeters (TLD) and diodes, are usually calibrated against low-energy megavoltage beams. To measure absolute dose rate near a brachytherapy source, it is necessary to establish the energy response of the detector relative to that of the calibration ener...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/6/004

    authors: Das RK,Li Z,Perera H,Williamson JF

    更新日期:1996-06-01 00:00:00

  • Measurement of total body nitrogen and oxygen by irradiation with cyclotron neutrons and 'delayed' gamma ray counting.

    abstract::Measurement of total body nitrogen is assuming increasing importance in the nutritional evaluation of seriously ill patients. Nitrogen has been previously measured either by counting (i) the annihilation radiation from 13N immediately after neutron irradiation with 14 MeV neutrons or (ii) the 'prompt' gamma rays from ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/4/008

    authors: Spinks TJ,Goode AW,Ranicar AS,Steere E

    更新日期:1984-04-01 00:00:00

  • A method for energy window optimization for quantitative tasks that includes the effects of model-mismatch on bias: application to Y-90 bremsstrahlung SPECT imaging.

    abstract::Quantitative Yttrium-90 ((90)Y) bremsstrahlung single photon emission computed tomography (SPECT) imaging has shown great potential to provide reliable estimates of (90)Y activity distribution for targeted radionuclide therapy dosimetry applications. One factor that potentially affects the reliability of the activity ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/12/3711

    authors: Rong X,Du Y,Frey EC

    更新日期:2012-06-21 00:00:00

  • Effects of bone- and air-tissue inhomogeneities on the dose distributions of the Leksell Gamma Knife calculated with PENELOPE.

    abstract::Monte Carlo simulation with PENELOPE (version 2003) is applied to calculate Leksell Gamma Knife dose distributions for heterogeneous phantoms. The usual spherical water phantom is modified with a spherical bone shell simulating the skull and an air-filled cube simulating the frontal or maxillary sinuses. Different sim...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/23/018

    authors: Al-Dweri FM,Rojas EL,Lallena AM

    更新日期:2005-12-07 00:00:00

  • Experimental characterization of lateral profiles of scanned proton and carbon ion pencil beams for improved beam models in ion therapy treatment planning.

    abstract::Scanned ion pencil beams carry a low-dose envelope which can extend up to several centimeters from the individual beam central axis. Depending on the energy and species of the beam, this halo consists mainly of secondary particles produced by nuclear interactions in the target or of particles undergoing multiple Coulo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/24/009

    authors: Schwaab J,Brons S,Fieres J,Parodi K

    更新日期:2011-12-21 00:00:00

  • Variation of the dielectric properties of tissues with age: the effect on the values of SAR in children when exposed to walkie-talkie devices.

    abstract::In vitro dielectric properties of ageing porcine tissues were measured in the frequency range of 50 MHz-20 GHz, and the total combined uncertainties of the measurements were assessed. The results show statistically significant reduction with age in both permittivity and conductivity of 10 out of 15 measured tissues. A...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/2/004

    authors: Peyman A,Gabriel C,Grant EH,Vermeeren G,Martens L

    更新日期:2009-01-21 00:00:00

  • Strategies to improve 3D whole-body PET image reconstruction.

    abstract::An algorithm is described for three-dimensional whole-body (3DWB) image reconstruction in positron emission tomography. For whole-body applications, improvements to the popular fixed-axial-acceptance-angle technique are achieved by combining axially adjacent projection data available with a long-axis data set. Time-co...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/8/013

    authors: Cutler PD,Xu M

    更新日期:1996-08-01 00:00:00

  • Geometrically undistorted MRI in the presence of field inhomogeneities using compressed sensing accelerated broadband 3D phase encoded turbo spin-echo imaging.

    abstract::In this study, we explore the potential of compressed sensing (CS) accelerated broadband 3D phase-encoded turbo spin-echo (3D-PE-TSE) for the purpose of geometrically undistorted imaging in the presence of field inhomogeneities. To achieve this goal 3D-PE-SE and 3D-PE-TSE sequences with broadband rf pulses and dedicat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/2/615

    authors: van Gorp JS,Bakker CJ,Bouwman JG,Smink J,Zijlstra F,Seevinck PR

    更新日期:2015-01-21 00:00:00

  • Proton beam monitor chamber calibration.

    abstract::The first goal of this paper is to clarify the reference conditions for the reference dosimetry of clinical proton beams. A clear distinction is made between proton beam delivery systems which should be calibrated with a spread-out Bragg peak field and those that should be calibrated with a (pseudo-)monoenergetic prot...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/17/4961

    authors: Gomà C,Lorentini S,Meer D,Safai S

    更新日期:2014-09-07 00:00:00

  • Image quality improvements of electronic portal imaging devices by multi-level gain calibration and temperature correction.

    abstract::Amorphous silicon (aSi:H) flat panel detectors are prevalent in radiotherapy for megavoltage imaging tasks. Any clinical and dosimetrical application requires a well-defined dose response of the system to achieve meaningful results. Due to radiation damages, panels deteriorate and the linearity of pixel response to do...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/18/6429

    authors: Huber S,Mooslechner M,Mitterlechner B,Weichenberger H,Serpa M,Sedlmayer F,Deutschmann H

    更新日期:2013-09-21 00:00:00

  • Monte Carlo calculations of the energy response of lithium dosemeters to high energy electrons (less than 30 MeV).

    abstract::Monte Carlo calculations of the energy response of LiF dosemeters have been carried out to help resolve the discrepancy between the measurements of Holt, Edelstein and Clark (1975) and those of Paliwal and Almond (1975) and others. It is concluded that the assumptions used by Holt et al. are largely responsible. They ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/22/5/003

    authors: O'Brien K

    更新日期:1977-09-01 00:00:00

  • The influence of a clear layer on near-infrared spectrophotometry measurements using a liquid neonatal head phantom.

    abstract::It is difficult to test near-infrared spectrophotometry instruments in vivo. Therefore we constructed a liquid phantom which mimics the neonatal head. It consists of a spherical 3.5 mm thick layer of silicone rubber simulating skin and bone and a 0.5 mm thick clear layer of polypropylene imitating cerebrospinal fluid....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/7/313

    authors: Wolf M,Keel M,Dietz V,von Siebenthal K,Bucher HU,Baenziger O

    更新日期:1999-07-01 00:00:00

  • Comparison of SAR and induced current densities in adults and children exposed to electromagnetic fields from electronic article surveillance devices.

    abstract::Electronic article surveillance (EAS) devices are widely used in most stores as anti-theft systems. In this work, the compliance with international guidelines in the human exposure to these devices is analysed by using the finite-difference time-domain (FDTD) method. Two sets of high resolution numerical phantoms of d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/4/009

    authors: Martínez-Búrdalo M,Sanchis A,Martín A,Villar R

    更新日期:2010-02-21 00:00:00

  • Investigation of patient, tumour and treatment variables affecting residual motion for respiratory-gated radiotherapy.

    abstract::Respiratory gating can reduce the apparent respiratory motion during imaging and treatment; however, residual motion within the gating window remains. Respiratory training can improve respiratory reproducibility and, therefore, the efficacy of respiratory-gated radiotherapy. This study was conducted to determine wheth...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/20/015

    authors: George R,Ramakrishnan V,Siebers JV,Chung TD,Keall PJ

    更新日期:2006-10-21 00:00:00

  • Understanding radionuclide production in gas target systems: the effect of adsorption on the target body.

    abstract::Gas target systems have been used for decades on cyclotrons to produce radionuclides for medical imaging. However, the activity recovered from such targets is often lower than its theoretically predicted value. Past research has suggested that nuclide interactions with the walls of the target body may play a key role ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aadf7b

    authors: Zacchia NA,Buckley KR,Martinez GM,Ruth TJ,Martinez DM,Hoehr C

    更新日期:2018-09-28 00:00:00

  • Dead time correction and counting statistics for positron tomography.

    abstract::A correction for loss of events due to dead time in dynamic positron emission tomography (PET) is presented. The model employs a paralysing dead time to describe the behaviour of a tomograph over the range of event rates normally encountered in patient studies (up to 200 000 events/s per detector layer). The Donner 28...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/5/002

    authors: Mazoyer BM,Roos MS,Huesman RH

    更新日期:1985-05-01 00:00:00