Electron depth-dose dependence on energy spectral quality.

Abstract:

:Electron depth-dose curves and spectra have been measured from an experimental accelerator on which both energy and spectral shape could be varied independently. The measurements were made at nominal energies of 6 and 12 MeV, with the energy spread (FWHM) varied from 1.7% to over 10% of average energy. Changes in depth-dose fall-off characteristics correlated only weakly with the width of the accelerator's spectrum. The use of a single accelerator and experiment set-up eliminated the differences that have complicated previous comparisons of beams of different spectral quality, which have been based upon data from different accelerator designs.

journal_name

Phys Med Biol

authors

Johnsen SW,LaRiviere PD,Tanabe E

doi

10.1088/0031-9155/28/12/005

subject

Has Abstract

pub_date

1983-12-01 00:00:00

pages

1401-7

issue

12

eissn

0031-9155

issn

1361-6560

journal_volume

28

pub_type

杂志文章
  • Accounting for range uncertainties in the optimization of intensity modulated proton therapy.

    abstract::Treatment plans optimized for intensity modulated proton therapy (IMPT) may be sensitive to range variations. The dose distribution may deteriorate substantially when the actual range of a pencil beam does not match the assumed range. We present two treatment planning concepts for IMPT which incorporate range uncertai...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/10/009

    authors: Unkelbach J,Chan TC,Bortfeld T

    更新日期:2007-05-21 00:00:00

  • Dosimetry for the MRI accelerator: the impact of a magnetic field on the response of a Farmer NE2571 ionization chamber.

    abstract::The UMC Utrecht is constructing a 1.5 T MRI scanner integrated with a linear accelerator (Lagendijk et al 2008 Radiother. Oncol. 86 25-9). The goal of this device is to facilitate soft-tissue contrast based image-guided radiotherapy, in order to escalate the dose to the tumour while sparing surrounding normal tissues....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/10/002

    authors: Meijsing I,Raaymakers BW,Raaijmakers AJ,Kok JG,Hogeweg L,Liu B,Lagendijk JJ

    更新日期:2009-05-21 00:00:00

  • Should image rotation be addressed during routine cone-beam CT quality assurance?

    abstract::The purpose of this study is to investigate whether quality assurance (QA) for cone-beam computed tomography (CBCT) image rotation is necessary in order to ensure the accuracy of CBCT based image-guided radiation therapy (IGRT) and adaptive radiotherapy (ART). Misregistration of angular coordinates during CBCT acquisi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/4/1059

    authors: Ayan AS,Lin H,Yeager C,Deville C,McDonough J,Zhu TC,Anderson N,Bar Ad V,Lu HM,Both S

    更新日期:2013-02-21 00:00:00

  • Characterization of a preclinical PET insert in a 7 Tesla MRI scanner: beyond NEMA testing.

    abstract::This study evaluates the performance of the Bruker positron emission tomograph (PET) insert combined with a BioSpec 70/30 USR magnetic resonance imaging (MRI) scanner using the manufacturer acceptance protocol and the NEMA NU 4-2008 for small animal PET. The PET insert is made of 3 rings of 8 monolithic LYSO crystals ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aba08c

    authors: Gsell W,Molinos C,Correcher C,Belderbos S,Wouters J,Junge S,Heidenreich M,Vande Velde G,Rezaei A,Nuyts J,Cawthorne C,Cleeren F,Nannan L,Deroose CM,Himmelreich U,González Martínez AJ

    更新日期:2020-06-26 00:00:00

  • The induction of hyperthermia by ultrasound; its value and associated problems: II. Scanned-plane transducer.

    abstract::A system is described in which large superficial areas of tissue may be heated using a single plane ultrasonic transducer scanned in a raster fashion. The shape of the heated area is determined by the movement of a microswitch which is activated when it strikes the rigid edge of a hole of the required shape cut in a p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/12/006

    authors: ter Haar G,Hopewell JW

    更新日期:1985-12-01 00:00:00

  • Simultaneous EEG-fMRI: evaluating the effect of the cabling configuration on the gradient artefact.

    abstract::EEG recordings made in combined EEG-fMRI studies are corrupted by gradient artefacts (GAs) resulting from the interaction of the EEG system with the time-varying magnetic field gradients used in MRI. The dominant contribution to the GA arises from interaction with the leads of the EEG cap and the human head, but artef...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/12/N241

    authors: Chowdhury ME,Mullinger KJ,Bowtell R

    更新日期:2015-06-21 00:00:00

  • ICRP Publication 116--the first ICRP/ICRU application of the male and female adult reference computational phantoms.

    abstract::ICRP Publication 116 on 'Conversion coefficients for radiological protection quantities for external radiation exposures', provides fluence-to-dose conversion coefficients for organ-absorbed doses and effective dose for various types of external exposures (ICRP 2010 ICRP Publication 116). The publication supersedes th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/18/5209

    authors: Petoussi-Henss N,Bolch WE,Eckerman KF,Endo A,Hertel N,Hunt J,Menzel HG,Pelliccioni M,Schlattl H,Zankl M

    更新日期:2014-09-21 00:00:00

  • Optimization of attenuation correction for positron emission tomography studies of thorax and pelvis using count-based transmission scans.

    abstract::The quality of thorax and pelvis transmission scans and therefore of attenuation correction in PET depends on patient thickness and transmission rod source strength. The purpose of the present study was to assess the feasibility of using count-based transmission scans, thereby guaranteeing more consistent image qualit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/4/n01

    authors: Boellaard R,van Lingen A,van Balen SC,Lammertsma AA

    更新日期:2004-02-21 00:00:00

  • The replacement correction factors for cylindrical chambers in high-energy photon beams.

    abstract::The values of the replacement correction factors (P(repl), or in the IAEA's notation p(dis)p(cav)) used for cylindrical chambers in high-energy photon beams represent one of the most significant differences between the AAPM and the IAEA dosimetry protocols. In a previous study (Wang L L W and Rogers D W O 2008 Med. Ph...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/6/014

    authors: Wang LL,Rogers DW

    更新日期:2009-03-21 00:00:00

  • Scheduling cisplatin and radiotherapy in the treatment of squamous cell carcinomas of the head and neck: a modelling approach.

    abstract::The aim of the present work was to implement the kinetics of cisplatin into a previously developed tumour growth model and to simulate the combined cisplatin-radiotherapy treatment with the emphasis on time sequencing and scheduling of drug and radiation. An investigation into whether the effect of cisplatin-radiation...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/15/002

    authors: Marcu L,Bezak E,Olver I

    更新日期:2006-08-07 00:00:00

  • Dosimetric accuracy of planning and delivering small proton therapy fields.

    abstract::A detailed Monte Carlo model of a proton therapy treatment head was commissioned to simulate the delivery of small field proton treatments. Small fields are challenging in the planning and quality assurance process because of aperture scattering and dosimetric disequilibrium. Four patients with small fields used in al...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/24/003

    authors: Bednarz B,Daartz J,Paganetti H

    更新日期:2010-12-21 00:00:00

  • Segmentation of dynamic PET images with kinetic spectral clustering.

    abstract::Segmentation is often required for the analysis of dynamic positron emission tomography (PET) images. However, noise and low spatial resolution make it a difficult task and several supervised and unsupervised methods have been proposed in the literature to perform the segmentation based on semi-automatic clustering of...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/19/6931

    authors: Mouysset S,Zbib H,Stute S,Girault JM,Charara J,Noailles J,Chalon S,Buvat I,Tauber C

    更新日期:2013-10-07 00:00:00

  • Improving SAR estimations in MRI using subject-specific models.

    abstract::To monitor and strategically control energy deposition in magnetic resonance imaging (MRI), measured as a specific absorption rate (SAR), numerical methods using generic human models have been employed to estimate worst-case values. Radiofrequency (RF) sequences are therefore often designed conservatively with large s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/24/8153

    authors: Jin J,Liu F,Weber E,Crozier S

    更新日期:2012-12-21 00:00:00

  • Resolving fluorophores by unmixing multispectral fluorescence tomography with independent component analysis.

    abstract::It is a challenging problem to resolve and identify drug (or non-specific fluorophore) distribution throughout the whole body of small animals in vivo. In this article, an algorithm of unmixing multispectral fluorescence tomography (MFT) images based on independent component analysis (ICA) is proposed to solve this pr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/17/5025

    authors: Pu H,Zhang G,He W,Liu F,Guang H,Zhang Y,Bai J,Luo J

    更新日期:2014-09-07 00:00:00

  • Radiofrequency and microwave dielectric properties of aqueous cryoprotectant agents: dimethyl sulphoxide and 2,3-butanediol.

    abstract::Earlier work on the dielectric properties of cryoprotectant agents is extended using a modified measuring cell and method of data reduction yielding results more efficiently over a temperature range from -75 to +25 degrees C at frequencies from 27 MHz to 3 GHz. Dimethyl sulphoxide and butanediol are investigated at lo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/10/011

    authors: Evans S,bin Azeman A

    更新日期:1998-10-01 00:00:00

  • Image-guidance for surgical procedures.

    abstract::Contemporary imaging modalities can now provide the surgeon with high quality three- and four-dimensional images depicting not only normal anatomy and pathology, but also vascularity and function. A key component of image-guided surgery (IGS) is the ability to register multi-modal pre-operative images to each other an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/51/14/R01

    authors: Peters TM

    更新日期:2006-07-21 00:00:00

  • Spectrum reconstruction from dose measurements as a linear inverse problem.

    abstract::There are three ways to determine the spectrum of a clinical photon beam: direct measurement, modelling the source and reconstruction from ion-chamber measurements. We focus on reconstruction because the necessary equipment is readily available and it provides independent confirmation of source models for a given mach...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/22/005

    authors: Armbruster B,Hamilton RJ,Kuehl AK

    更新日期:2004-11-21 00:00:00

  • Magnetorelaxometric quantification of magnetic nanoparticles in an artery model after ex vivo magnetic drug targeting.

    abstract::In magnetic drug targeting a chemotherapeutic agent is bound to coated magnetic nanoparticles, which are administered to the blood vessel system and subsequently focused by an external applied magnetic field. The optimization of intra-arterial magnetic drug targeting (MDT) requires detailed knowledge about the biodist...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/18/N03

    authors: Richter H,Wiekhorst F,Schwarz K,Lyer S,Tietze R,Alexiou Ch,Trahms L

    更新日期:2009-09-21 00:00:00

  • Late rectal bleeding after 3D-CRT for prostate cancer: development of a neural-network-based predictive model.

    abstract::The aim of this study was to develop a model exploiting artificial neural networks (ANNs) to correlate dosimetric and clinical variables with late rectal bleeding in prostate cancer patients undergoing radical radiotherapy and to compare the ANN results with those of a standard logistic regression (LR) analysis. 718 m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/5/1399

    authors: Tomatis S,Rancati T,Fiorino C,Vavassori V,Fellin G,Cagna E,Mauro FA,Girelli G,Monti A,Baccolini M,Naldi G,Bianchi C,Menegotti L,Pasquino M,Stasi M,Valdagni R

    更新日期:2012-03-07 00:00:00

  • Optimization-based image reconstruction with artifact reduction in C-arm CBCT.

    abstract::We investigate an optimization-based reconstruction, with an emphasis on image-artifact reduction, from data collected in C-arm cone-beam computed tomography (CBCT) employed in image-guided interventional procedures. In the study, an image to be reconstructed is formulated as a solution to a convex optimization progra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/20/7300

    authors: Xia D,Langan DA,Solomon SB,Zhang Z,Chen B,Lai H,Sidky EY,Pan X

    更新日期:2016-10-21 00:00:00

  • A method for determining the diffusion coefficient in Fe(II/III) radiation dosimetry gels using finite elements.

    abstract::Magnetic resonance imaging (MRI) may be used to image three-dimensional dose distributions of ionizing radiation in tissue equivalent gels infused with ferrous sulphate solutions, commonly known as Fricke gels. In this technique, ferrous (Fe2+) ions are oxidized to ferric (Fe3+) ions by free radicals produced by ioniz...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/9/013

    authors: Harris PJ,Piercy A,Baldock C

    更新日期:1996-09-01 00:00:00

  • Monte Carlo simulation to evaluate the contamination in an energy modulated carbon ion beam for hadron therapy delivered by cyclotron.

    abstract::Protons and carbon ion beams for hadron therapy can be delivered by cyclotrons with a fixed energy. In order to treat patients, an energy degrader along the beam line will be used to match the particle range with the target depth. Fragmentation reactions of carbon ions inside the degrader material could introduce a sm...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/21/010

    authors: Morone MC,Calabretta L,Cuttone G,Fiorini F

    更新日期:2008-11-07 00:00:00

  • The Hug-Kellerer equation as the universal cell survival curve.

    abstract::The Hug-Kellerer (H-K) equation is one of the earliest proposed radiation cell survival curves. We examine this equation in view of the recent perceived need for a universal cell survival curve which would be applicable to single radiation fractions at high doses. We derive relationships between the three parameters o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/10/N01

    authors: Ekstrand KE

    更新日期:2010-05-21 00:00:00

  • A proposal concerning the absorbed dose conversion factor.

    abstract::New definitions of the absorbed dose conversion factors Clambda and CE are proposed. The absorbed dose in water is given by the product of absorbed dose conversion factor, exposure calibration factor, ionisation chamber reading, cap displacement correction factor and perturbation correction factor. At exposure calibra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/23/2/003

    authors: Shiragai A

    更新日期:1978-03-01 00:00:00

  • Comparison of Geant4 multiple Coulomb scattering models with theory for radiotherapy protons.

    abstract::Usually, Monte Carlo models are validated against experimental data. However, models of multiple Coulomb scattering (MCS) in the Gaussian approximation are exceptional in that we have theories which are probably more accurate than the experiments which have, so far, been done to test them. In problems directly sensiti...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6ce3

    authors: Makarova A,Gottschalk B,Sauerwein W

    更新日期:2017-07-06 00:00:00

  • The use of customized spreadsheets in radiation therapy.

    abstract::A number of radiation-therapy-related uses based on a commercially available spreadsheet program have been developed at our facility. The graphics and display capabilities inherent in these spreadsheet programs allow for concise visual results. The spreadsheets are used as an independent check for several types of rad...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/6/007

    authors: Balog JP,Sibata CH,Podgorsak MB,Shin KH

    更新日期:1995-06-01 00:00:00

  • Investigation of patient, tumour and treatment variables affecting residual motion for respiratory-gated radiotherapy.

    abstract::Respiratory gating can reduce the apparent respiratory motion during imaging and treatment; however, residual motion within the gating window remains. Respiratory training can improve respiratory reproducibility and, therefore, the efficacy of respiratory-gated radiotherapy. This study was conducted to determine wheth...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/20/015

    authors: George R,Ramakrishnan V,Siebers JV,Chung TD,Keall PJ

    更新日期:2006-10-21 00:00:00

  • Radiation binary targeted therapy for HER-2 positive breast cancers: assumptions, theoretical assessment and future directions.

    abstract::A novel radiation targeted therapy is investigated for HER-2 positive breast cancers. The proposed concept combines two known approaches, but never used together for the treatment of advanced, relapsed or metastasized HER-2 positive breast cancers. The proposed radiation binary targeted concept is based on the anti HE...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/6/001

    authors: Mundy DW,Harb W,Jevremovic T

    更新日期:2006-03-21 00:00:00

  • Monte Carlo generated mammograms: development and validation.

    abstract::We have developed a model using Monte Carlo methods to simulate x-ray mammography. All possible physical processes of interaction of x-rays with matter have been taken into account. A simplified geometry of the mammographic apparatus has been considered along with a software phantom of compressed breast. The phantom m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/11/012

    authors: Spyrou G,Tzanakos G,Bakas A,Panayiotakis G

    更新日期:1998-11-01 00:00:00

  • Relative determination of W-values for alpha particles in tissue-equivalent and other gases.

    abstract::W (the average energy to form an ion pair) for 5.4 MeV 241Am alpha particles in a Rossi-type tissue-equivalent (TE) gas, argon and methane was determined to an accuracy better than 0.2% using a new automated data handling system. A vibrating reed electrometer and current digitiser were used to measure the current prod...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/24/2/005

    authors: Krieger GL,Baum JW,Varma MN,Beach JL

    更新日期:1979-03-01 00:00:00