Strategies to improve 3D whole-body PET image reconstruction.

Abstract:

:An algorithm is described for three-dimensional whole-body (3DWB) image reconstruction in positron emission tomography. For whole-body applications, improvements to the popular fixed-axial-acceptance-angle technique are achieved by combining axially adjacent projection data available with a long-axis data set. Time-consuming reprojection of unmeasured oblique lines of response is reduced or eliminated by axial overlap of bed positions, while pixel variance and reconstructed axial resolution are made more uniform by the overlap. Improvements in noise and resolution uniformity are accompanied by gains in reconstruction efficiency, and may be optimized against increased acquisition-time due to overlapping acquisition segments and reduced axial coverage. An 11-detector-ring overlap improves axial uniformity in coronal images of a long, uniform cylinder from 23% to 8% with uniform axial resolution. Associated with a 37% improvement in reconstruction time is a 34% reduction in axial coverage for four bed positions. A smaller degree of overlap is found to provide the best trade-off between image uniformity, total scan duration, and reconstruction time because of a proportionally greater reduction in reprojected lines of response. Using a sample optimization scheme, we find a three-ring overlap is best for a 60 cm axial field of view and a five-ring overlap for an 80 cm axial field of view.

journal_name

Phys Med Biol

authors

Cutler PD,Xu M

doi

10.1088/0031-9155/41/8/013

subject

Has Abstract

pub_date

1996-08-01 00:00:00

pages

1453-67

issue

8

eissn

0031-9155

issn

1361-6560

journal_volume

41

pub_type

杂志文章
  • The GSF family of voxel phantoms.

    abstract::Voxel phantoms are human models based on computed tomographic or magnetic resonance images obtained from high-resolution scans of a single individual. They consist of a huge number of volume elements (voxels) and are at the moment the most precise representation of the human anatomy. The purpose of this paper is to in...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/47/1/307

    authors: Petoussi-Henss N,Zanki M,Fill U,Regulla D

    更新日期:2002-01-07 00:00:00

  • On the dosimetric behaviour of photon dose calculation algorithms in the presence of simple geometric heterogeneities: comparison with Monte Carlo calculations.

    abstract::A comparative study was performed to reveal differences and relative figures of merit of seven different calculation algorithms for photon beams when applied to inhomogeneous media. The following algorithms were investigated: Varian Eclipse: the anisotropic analytical algorithm, and the pencil beam with modified Batho...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/5/011

    authors: Fogliata A,Vanetti E,Albers D,Brink C,Clivio A,Knöös T,Nicolini G,Cozzi L

    更新日期:2007-03-07 00:00:00

  • High-energy radiation monitoring based on radio-fluorogenic co-polymerization. I: Small volume in situ probe.

    abstract::A method of radiation dosimetry is described which is based on the radiation-induced initiation of polymerization of a bulk monomer (e.g. methyl methacrylate) containing a small concentration (about 100 ppm) of a compound which is non-fluorescent but which becomes highly fluorescent when it is incorporated into a grow...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/10/015

    authors: Warman JM,de Haas MP,Luthjens LH

    更新日期:2009-05-21 00:00:00

  • Elastography--the movement begins.

    abstract::The advent of real-time ultrasound in the 1970s, together with a growing interest in tissue characterization, led to a number of investigators using the nature of tissue motion to distinguish healthy from diseased tissue. Our group at the (then) Ultrasonics Institute demonstrated the use of phase methods for detecting...

    journal_title:Physics in medicine and biology

    pub_type: 历史文章,杂志文章

    doi:10.1088/0031-9155/45/6/301

    authors: Wilson LS,Robinson DE,Dadd MJ

    更新日期:2000-06-01 00:00:00

  • A multi-scale framework with unsupervised joint training of convolutional neural networks for pulmonary deformable image registration.

    abstract::To achieve accurate and fast deformable image registration (DIR) for pulmonary CT, we proposed a Multi-scale DIR framework with unsupervised Joint training of Convolutional Neural Network (MJ-CNN). MJ-CNN contains three models at multi-scale levels for a coarse-to-fine DIR to avoid being trapped in a local minimum. It...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab5da0

    authors: Jiang Z,Yin FF,Ge Y,Ren L

    更新日期:2020-01-13 00:00:00

  • Radiance and particle fluence.

    abstract::The concepts of radiance and fluence are fundamental to the description of a radiation field. The International Commission on Radiological Units and Measurements (ICRU) has defined fluence in terms of the number of the radiation particles crossing a small sampling sphere. A second definition has been proposed in which...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/6/011

    authors: Papiez L,Battista JJ

    更新日期:1994-06-01 00:00:00

  • Metal artifact reduction method based on a constrained beam-hardening estimator for polychromatic x-ray CT.

    abstract::Beam hardening is inevitable due to the polychromatic X-ray spectrum and energy-dependent attenuation coefficients of materials, leading to the underestimation of artifacts arising from projection data, especially on metal regions. State-of-the-art research on beam-hardening artifacts is based on a numerical method th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abe026

    authors: Hur J,Kim D,Shin YG,Lee H

    更新日期:2021-01-26 00:00:00

  • An investigation of factors affecting the accuracy of in vivo measurements of skin pigments by reflectance spectrophotometry.

    abstract::Factors affecting the accuracy of the in vivo measurement of cutaneous pigments and blood oxygenation by reflectance spectrophotometry have been examined. It was found that stray light, the amounts of haemoglobin and melanin, and the level of blood oxygenation all contributed to the measured reflectance and had to be ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/35/9/009

    authors: Hajizadeh-Saffar M,Feather JW,Dawson JB

    更新日期:1990-09-01 00:00:00

  • Temporal backward projection of optoacoustic pressure transients using fourier transform methods.

    abstract::In medical imaging different techniques have been developed to gain information from inside a tissue. Optoacoustics is a method to generate tomography pictures of tissue using Q-switched laser pulses. Due to thermal and pressure confinement, a short light pulse generates a pressure distribution inside tissue, which mi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/7/309

    authors: Köstli KP,Frenz M,Bebie H,Weber HP

    更新日期:2001-07-01 00:00:00

  • A revised monitor source method for practical deadtime count loss compensation in clinical planar and SPECT studies.

    abstract::The aim of the study is to verify the fundamental assumption in the monitor source method, i.e. uniform fractional count loss across the field of view (FOV), and to introduce a revised monitor source method for SPECT deadtime correction that minimally interferes with the clinical protocol. SPECT images of non-uniform ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/3/1199

    authors: Siman W,Silosky M,Kappadath SC

    更新日期:2015-02-07 00:00:00

  • SAR calculations in an anatomically realistic model of the head for mobile communication transceivers at 900 MHz and 1.8 GHz.

    abstract::A new mathematical model of the head has been constructed from a set of serial MRI slices from one subject. Finite-difference time-domain (FDTD) calculations of the specific energy absorption rate (SAR) have been performed on this model with a 2 mm resolution for a generic mobile communication transceiver represented ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/10/003

    authors: Dimbylow PJ,Mann SM

    更新日期:1994-10-01 00:00:00

  • Comparison between TG-51 and TRS-398: electron contamination effect on photon beam-quality specification.

    abstract::Two dosimetry protocols based on absorbed dose to water have recently been implemented: TG-51 and TRS-398. These protocols use different beam-quality indices: %dd(10)x and TPR20,10. The effect of electron contamination in measurements of %dd(10)x has been proposed as a disadvantage of the TG-51. For actual measurement...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/1/002

    authors: Lopez Medina A,Teijeiro A,Salvador F,Medal D,Vazquez J,Salgado M,Carrion MC

    更新日期:2004-01-07 00:00:00

  • Optimizing wavelength choice for quantitative optoacoustic imaging using the Cramer-Rao lower bound.

    abstract::Several papers have recently addressed the issue of estimating chromophore concentration in optoacoustic imaging (OAI) using multiple wavelengths. The choice of wavelengths obviously affects the accuracy and precision of the estimates. One might assume that the wavelengths that maximize the extinction coefficients of ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/23/004

    authors: Modgil D,La Riviére PJ

    更新日期:2010-12-07 00:00:00

  • T1 and extracellular volume fraction mapping in cardiac magnetic resonance: estimation of accuracy and precision of a novel algorithm.

    abstract::Magnetic resonance imaging is effective for non-invasive detection of myocardial diseases by extracellular volume fraction (ECV) estimation. A new methodology for T1 and ECV mapping is tested in this work, comparing results with other well-consolidated methods. The associated level of uncertainty for data was also est...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aafcca

    authors: Borrazzo C,Pacilio M,Galea N,Preziosi E,Carnì M,Francone M,Catalano C,Carbone I

    更新日期:2019-02-11 00:00:00

  • SiPM signal readout for inter-crystal scatter event identification in PET detectors.

    abstract::In positron emission tomography (PET) with pixelated detectors, a significant number of annihilation photons interact with scintillation crystals through single or multiple Compton scattering events. When these partial energy depositions occur across multiple crystal elements, we call them inter-crystal scatter (ICS) ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aba8b4

    authors: Park H,Lee JS

    更新日期:2020-10-21 00:00:00

  • Physical mechanisms of gas and perfluoron retinopexy and sub-retinal fluid displacement.

    abstract::Injection of gas into the eye, followed by face-down positioning, is a common protocol for the reseating of the retina in posterior and superior retinal tears and breaks. The physical mechanism by which injected gas helps reattach retinal flaps is often ascribed to the 'buoyancy' force of the injected gas bubble. The ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/13/015

    authors: Foster WJ,Chou T

    更新日期:2004-07-07 00:00:00

  • The feasibility of estimating and imaging the mechanical behavior of poroelastic materials using axial strain elastography.

    abstract::In this paper, we have investigated the feasibility of imaging the mechanical behavior of poroelastic materials using axial strain elastography. Cylindrical samples obtained from poroelastic materials having different elastic and permeability properties were subjected to a constant compression force (a classical creep...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/11/020

    authors: Righetti R,Righetti M,Ophir J,Krouskop TA

    更新日期:2007-06-07 00:00:00

  • Measurement of effective detective quantum efficiency for a photon counting scanning mammography system and comparison with two flat panel full-field digital mammography systems.

    abstract::Effective detective quantum efficiency (eDQE) describes the resolution and noise properties of an imaging system along with scatter and primary transmission, all measured under clinically appropriate conditions. Effective dose efficiency (eDE) is the eDQE normalised to mean glandular dose and has been proposed as a us...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa307

    authors: Wood TJ,Moore CS,Saunderson JR,Beavis AW

    更新日期:2018-01-16 00:00:00

  • Online prediction of respiratory motion: multidimensional processing with low-dimensional feature learning.

    abstract::Accurate real-time prediction of respiratory motion is desirable for effective motion management in radiotherapy for lung tumor targets. Recently, nonparametric methods have been developed and their efficacy in predicting one-dimensional respiratory-type motion has been demonstrated. To exploit the correlation among v...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/11/002

    authors: Ruan D,Keall P

    更新日期:2010-06-07 00:00:00

  • Reducing 4DCBCT imaging time and dose: the first implementation of variable gantry speed 4DCBCT on a linear accelerator.

    abstract::Four dimensional cone beam computed tomography (4DCBCT) uses a constant gantry speed and imaging frequency that are independent of the patient's breathing rate. Using a technique called respiratory motion guided 4DCBCT (RMG-4DCBCT), we have previously demonstrated that by varying the gantry speed and imaging frequency...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/62/11/4300

    authors: O'Brien RT,Stankovic U,Sonke JJ,Keall PJ

    更新日期:2017-06-07 00:00:00

  • Implementation of pencil kernel and depth penetration algorithms for treatment planning of proton beams.

    abstract::The implementation of two algorithms for calculating dose distributions for radiation therapy treatment planning of intermediate energy proton beams is described. A pencil kernel algorithm and a depth penetration algorithm have been incorporated into a commercial three dimensional treatment planning system (Helax-TMS,...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/1/302

    authors: Russell KR,Isacsson U,Saxner M,Ahnesjö A,Montelius A,Grusell E,Dahlgren CV,Lorin S,Glimelius B

    更新日期:2000-01-01 00:00:00

  • An edge-on charge-transfer design for energy-resolved x-ray detection.

    abstract::As an x-ray beam goes through the human body, it will collect important information via interaction with tissues. Since this interaction is energy-sensitive, the state-of-the-art spectral CT technologies provide higher quality images of biological tissues with x-ray energy information (or spectral information). With e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/11/4183

    authors: Shi Z,Yang H,Cong W,Wang G

    更新日期:2016-06-07 00:00:00

  • Single patient convolutional neural networks for real-time MR reconstruction: a proof of concept application in lung tumor segmentation for adaptive radiotherapy.

    abstract::Investigate 3D (spatial and temporal) convolutional neural networks (CNNs) for real-time on-the-fly magnetic resonance imaging (MRI) reconstruction. In particular, we investigated the applicability of training CNNs on a patient-by-patient basis for the purpose of lung tumor segmentation. Data were acquired with our 3 ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab408e

    authors: Dietz B,Yun J,Yip E,Gabos Z,Fallone BG,Wachowicz K

    更新日期:2019-09-23 00:00:00

  • Precise measurement of cerebral blood flow in newborn piglets from the bolus passage of indocyanine green.

    abstract::Indocyanine green (ICG) is a near-infrared dye that has the potential to be used as a tracer for the minimally invasive measurement of cerebral blood flow (CBF). In order to examine the technique, the arterial and cerebral concentrations of ICG were measured in newborn piglets during the bolus passage of ICG at normoc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/8/312

    authors: Springett R,Sakata Y,Delpy DT

    更新日期:2001-08-01 00:00:00

  • Monte Carlo simulations of a nozzle for the treatment of ocular tumours with high-energy proton beams.

    abstract::By the end of 2002, 33 398 patients worldwide had been treated with proton radiotherapy, 10 829 for eye diseases. The dose prediction algorithms used today for ocular proton therapy treatment planning rely on parameterizations of measured proton dose distributions, i.e., broad-beam and pencil-beam techniques, whose pr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/22/002

    authors: Newhauser W,Koch N,Hummel S,Ziegler M,Titt U

    更新日期:2005-11-21 00:00:00

  • The observation and analysis of cancer deaths among classified radiation workers.

    abstract::The extent to which occupational radiation exposure contributes to cancer mortality is an influence on future world energy policy. It is also a factor in deciding the level of expenditure to reduce radiation levels experienced by workers. Here we discuss some of the difficulties in analysing the situation and presen...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/21/6/001

    authors: Reissland JA,Kay P,Dolphin GW

    更新日期:1976-11-01 00:00:00

  • Multi-isotope SPECT imaging of the 225Ac decay chain: feasibility studies.

    abstract::Effective use of the [Formula: see text] decay chain in targeted internal radioimmunotherapy requires the retention of both [Formula: see text] and progeny isotopes at the target site. Imaging-based pharmacokinetic tests of these pharmaceuticals must therefore separately yet simultaneously image multiple isotopes that...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6a99

    authors: Robertson AKH,Ramogida CF,Rodríguez-Rodríguez C,Blinder S,Kunz P,Sossi V,Schaffer P

    更新日期:2017-06-07 00:00:00

  • Counting losses in multidetector radiation counters.

    abstract::We examined the reasons for the reduction in response of a multidetector radiation counting system when operated at high count-rates and established a convenient method of correction which is accurate to within +/- 1% up to 0-6 X 10(5) counts per second. In its application the method uses the observed count-rates from...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/21/1/009

    authors: Oxby CB,Oldroyd B,Appleby DB

    更新日期:1976-01-01 00:00:00

  • Photon detection efficiency of laboratory-based x-ray phase contrast imaging techniques for mammography: a Monte Carlo study.

    abstract::An important challenge in real-world biomedical applications of x-ray phase contrast imaging (XPCI) techniques is the efficient use of the photon flux generated by an incoherent and polychromatic x-ray source. This efficiency can directly influence dose and exposure time and ideally should not affect the superior cont...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa7a92

    authors: Saghamanesh S,Aghamiri SM,Kamali-Asl A,Yashiro W

    更新日期:2017-09-01 00:00:00

  • Monte Carlo and experimental evaluation of accuracy and noise properties of two scatter correction methods for SPECT.

    abstract::Scatter correction is a prerequisite for quantitative SPECT, but potentially increases noise. Monte Carlo simulations (EGS4) and physical phantom measurements were used to compare accuracy and noise properties of two scatter correction techniques: the triple-energy window (TEW), and the transmission dependent convolut...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/11/017

    authors: Narita Y,Eberl S,Iida H,Hutton BF,Braun M,Nakamura T,Bautovich G

    更新日期:1996-11-01 00:00:00