Design of applicators for a 27 MHz multielectrode current source interstitial hyperthermia system; impedance matching and effective power.

Abstract:

:In interstitial heating one of the main requirements for achieving a certain elevated temperature in a tumour is that the effective power per applicator (Peff), i.e. the power which is actually deposited in the tissue, is sufficiently high. In this paper this requirement is discussed for the applicators of the 27 MHz multielectrode current source (MECS) interstitial hyperthermia (IHT) system. To minimize power reflection, the applicator impedance was matched with the generator impedance by adjusting the length of the coaxial cable in between. Transmission line losses, applicator efficiency and subsequently Peff were computed for several applicator types. The actual Peff per electrode was obtained from calorimetric measurements. Experiments with RC loads, which can be seen as perfect applicators, were performed to investigate the effect of mismatching on Peff. Applicator losses were measured for clinically used applicators, both single- and dual-electrode, utilizing saline phantoms. A simple spherical tumour model, using the effective heat conductivity (keff) to account for heat transport, was used to estimate Peff for a given tumour size, implant size and applicator density. Computations of Peff of various MECS-IHT electrodes were in close agreement with the phantom measurements. Most of the initial generator power was absorbed in the transmission line (60-65%). The efficiency of the applicators was about 65%. For both single- and dual-electrode applicators the effective electrode power was found to be about 1 W. Model calculations show that Peff of 1 W is sufficient to reach a minimum tumour temperature of 43 degrees C in well perfused tumours (keff = 3 W m-1 degree C-1), using a typical implant with 2 cm electrodes and 1.5 cm spacing. Mismatching can considerably affect Peff. Both a reduction to almost zero and a two-fold increase are possible. However, because the matching theory is well understood, mismatching is not a serious problem in clinical practice and can even be used to increase Peff if necessary. We conclude that the applicator design and the impedance matching method chosen in the MECS system allow heating to temperatures in the therapeutic range with implants used in clinical practice.

journal_name

Phys Med Biol

authors

Kaatee RS,Crezee J,Kanis AP,Lagendijk JJ,Levendag PC,Visser AG

doi

10.1088/0031-9155/42/6/007

subject

Has Abstract

pub_date

1997-06-01 00:00:00

pages

1087-108

issue

6

eissn

0031-9155

issn

1361-6560

journal_volume

42

pub_type

杂志文章
  • Optimizing wavelength choice for quantitative optoacoustic imaging using the Cramer-Rao lower bound.

    abstract::Several papers have recently addressed the issue of estimating chromophore concentration in optoacoustic imaging (OAI) using multiple wavelengths. The choice of wavelengths obviously affects the accuracy and precision of the estimates. One might assume that the wavelengths that maximize the extinction coefficients of ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/23/004

    authors: Modgil D,La Riviére PJ

    更新日期:2010-12-07 00:00:00

  • Investigation of patient, tumour and treatment variables affecting residual motion for respiratory-gated radiotherapy.

    abstract::Respiratory gating can reduce the apparent respiratory motion during imaging and treatment; however, residual motion within the gating window remains. Respiratory training can improve respiratory reproducibility and, therefore, the efficacy of respiratory-gated radiotherapy. This study was conducted to determine wheth...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/20/015

    authors: George R,Ramakrishnan V,Siebers JV,Chung TD,Keall PJ

    更新日期:2006-10-21 00:00:00

  • An automated, fast and accurate registration method to link stranded seeds in permanent prostate implants.

    abstract::The geometry of a permanent prostate implant varies over time. Seeds can migrate and edema of the prostate affects the position of seeds. Seed movements directly influence dosimetry which relates to treatment quality. We present a method that tracks all individual seeds over time allowing quantification of seed moveme...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/20/N391

    authors: Westendorp H,Nuver TT,Moerland MA,Minken AW

    更新日期:2015-10-21 00:00:00

  • Concentrations of Fe, Cu and Zn in breast tissue: a synchrotron XRF study.

    abstract::An x-ray fluorescence system with a synchrotron radiation source was used to quantify the levels of iron, copper and zinc in breast tissue specimens. Healthy tissue and breast carcinomas were investigated as an aid to understanding the mechanisms of breast cancer and as a possible complementary diagnostic tool. Eighty...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/13/310

    authors: Geraki K,Farquharson MJ,Bradley DA

    更新日期:2002-07-07 00:00:00

  • Deformable and durable phantoms with controlled density of scatterers.

    abstract::We have developed deformable and durable optical tissue phantoms with a simple and well-defined microstructure including a novel combination of scatterers and a matrix material. These were developed for speckle and elastography investigations in optical coherence tomography, but should prove useful in many other field...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/13/N01

    authors: Bisaillon CE,Lamouche G,Maciejko R,Dufour M,Monchalin JP

    更新日期:2008-07-07 00:00:00

  • The use of narrowband ultrasound for characterization of tissue in a thin layer.

    abstract::Most tissue characterization methods use RF data originating from backscattering processes in the insonified tissue. Characterization of the tissue of a thin layer (e.g., an artery wall) poses problems because of the small amount of data available. The tissue layer may be so thin that there are no RF data that are not...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/10/002

    authors: Linssen FM,Hoeks AP,Brands PJ

    更新日期:1991-10-01 00:00:00

  • Meshless reconstruction technique for digital tomosynthesis.

    abstract::A novel meshless reconstruction algorithm for digital tomosynthesis (DT) is presented and assessed against experimental data. The algorithm does not require a three-dimensional grid or mesh allocation and performs a slice-by-slice reconstruction where each slice position can be chosen at runtime. The methodology is ba...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab7685

    authors: Soloviev VY,Renforth KL,Dirckx CJ,Wells SG

    更新日期:2020-04-20 00:00:00

  • A study of the impact of x-ray tube performance on angiography system imaging efficiency.

    abstract::This work compared the impact of x-ray tube performance and automatic dose rate control (ADRC) parameter selection on system imaging efficiency of two Siemens angiography systems: a Siemens Megalix x-ray tube installed on an Artis Zee system (denoted 'MEGALIX') and a newer generation Gigalix x-ray tube installed on an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abbb7a

    authors: Dehairs M,Bosmans H,Marshall NW

    更新日期:2020-11-24 00:00:00

  • Arranging optical fibres for the spatial resolution improvement of topographical images.

    abstract::Optical topography is a method for visualization of conical activity. Ways of improving the spatial resolution of the topographical image with three arrangements of optical fibres are discussed. A distribution of sensitivity is obtained from the phantom experiment, and used to reconstruct topographical images of an ac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/18/311

    authors: Yamamoto T,Maki A,Kadoya T,Tanikawa Y,Yamad Y,Okada E,Koizumi H

    更新日期:2002-09-21 00:00:00

  • Analysis on reversible/irreversible electroporation region in lung adenocarcinoma cell modelin vitrowith electric pulses delivered by needle electrodes.

    abstract::Irreversible electroporation (IRE) is a minimally invasive tumor therapy using pulsed electric field with high intensity while the important tissues such as blood vessel, bile duct, and nerve are preserved. In addition to ablation area, reversible electroporation (RE) region is also generated using needle electrodes f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abc12e

    authors: Lv Y,Tang X,Peng W,Cheng X,Chen S,Yao C

    更新日期:2020-10-14 00:00:00

  • Characterization of the electromagnetic near-field absorption in layered biological tissue in the frequency range from 30 MHz to 6,000 MHz.

    abstract::Currently, standards for the compliance testing of wireless devices are being extended to cover a wider frequency band and different usage patterns of mobile phones as well as of novel body-worn and handheld devices. As a consequence, not only the head but also strongly varying tissue distributions of the body are exp...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/19/014

    authors: Christ A,Samaras T,Klingenböck A,Kuster N

    更新日期:2006-10-07 00:00:00

  • Intensity modulated radiation therapy for oropharyngeal cancer: the sensitivity of plan objectives and constraints to set-up uncertainty.

    abstract::The goal of this study was to assess the impact of set-up uncertainty on compliance with the objectives and constraints of an intensity modulated radiation therapy protocol for early stage cancer of the oropharynx. As the convolution approach to the quantitative study of set-up uncertainties cannot accommodate either ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/15/003

    authors: Ploquin N,Song W,Lau H,Dunscombe P

    更新日期:2005-08-07 00:00:00

  • Dose-volume histogram prediction using density estimation.

    abstract::Knowledge of what dose-volume histograms can be expected for a previously unseen patient could increase consistency and quality in radiotherapy treatment planning. We propose a machine learning method that uses previous treatment plans to predict such dose-volume histograms. The key to the approach is the framing of d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/17/6923

    authors: Skarpman Munter J,Sjölund J

    更新日期:2015-09-07 00:00:00

  • Mechanical analysis of an axially symmetric cylindrical phantom with a spherical heterogeneity for MR elastography.

    abstract::Cylindrical homogenous phantoms for magnetic resonance (MR) elastography in biomedical research provide one way to validate an imaging systems performance, but the simplified geometry and boundary conditions can cloak complexity arising at tissue interfaces. In an effort to develop a more realistic gel tissue phantom ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/18/6821

    authors: Schwartz BL,Yin Z,Magin RL

    更新日期:2016-09-21 00:00:00

  • Adaptation and applications of a realistic digital phantom based on patient lung tumor trajectories.

    abstract::Digital phantoms continue to play a significant role in modeling and characterizing medical imaging. The currently available XCAT phantom incorporates both the flexibility of mathematical phantoms and the realistic nature of voxelized phantoms. This phantom generates images based on a regular breathing pattern and can...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/11/3597

    authors: Mishra P,St James S,Segars WP,Berbeco RI,Lewis JH

    更新日期:2012-06-07 00:00:00

  • PET monitoring of cancer therapy with 3He and 12C beams: a study with the GEANT4 toolkit.

    abstract::We study the spatial distributions of beta(+)-activity produced by therapeutic beams of (3)He and (12)C ions in various tissue-like materials. The calculations were performed within a Monte Carlo model for heavy-ion therapy (MCHIT) based on the GEANT4 toolkit. The contributions from positron-emitting nuclei with T(1/2...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/24/007

    authors: Pshenichnov I,Larionov A,Mishustin I,Greiner W

    更新日期:2007-12-21 00:00:00

  • Improved scatter correction using adaptive scatter kernel superposition.

    abstract::Accurate scatter correction is required to produce high-quality reconstructions of x-ray cone-beam computed tomography (CBCT) scans. This paper describes new scatter kernel superposition (SKS) algorithms for deconvolving scatter from projection data. The algorithms are designed to improve upon the conventional approac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/22/007

    authors: Sun M,Star-Lack JM

    更新日期:2010-11-21 00:00:00

  • NTCP modelling and pulmonary function tests evaluation for the prediction of radiation induced pneumonitis in non-small-cell lung cancer radiotherapy.

    abstract::This work aims to evaluate the predictive strength of the relative seriality, parallel and Lyman-Kutcher-Burman (LKB) normal tissue complication probability (NTCP) models regarding the incidence of radiation pneumonitis (RP), in a group of patients following lung cancer radiotherapy and also to examine their correlati...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/4/013

    authors: Tsougos I,Nilsson P,Theodorou K,Kjellén E,Ewers SB,Jarlman O,Lind BK,Kappas C,Mavroidis P

    更新日期:2007-02-21 00:00:00

  • A method for determining the diffusion coefficient in Fe(II/III) radiation dosimetry gels using finite elements.

    abstract::Magnetic resonance imaging (MRI) may be used to image three-dimensional dose distributions of ionizing radiation in tissue equivalent gels infused with ferrous sulphate solutions, commonly known as Fricke gels. In this technique, ferrous (Fe2+) ions are oxidized to ferric (Fe3+) ions by free radicals produced by ioniz...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/9/013

    authors: Harris PJ,Piercy A,Baldock C

    更新日期:1996-09-01 00:00:00

  • Influence of the SURLAS applicator on radiation dose distributions during simultaneous thermoradiotherapy with helical tomotherapy.

    abstract::Simultaneous thermoradiotherapy has been shown to maximize the effect of hyperthermia as a radiation sensitizer in cancer treatment. Here we follow our previous work on feasibility of thermoradiotherapy with the scanning ultrasound reflector linear array system (SURLAS) and TomoTherapy HiArt treatment system, and inve...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/10/004

    authors: Novák P,Peñagarícano JA,Nahirnyak V,Corry P,Moros EG

    更新日期:2008-05-21 00:00:00

  • Comparative study of layered and volumetric rescanning for different scanning speeds of proton beam in liver patients.

    abstract::In recent years, particle therapy has become a widely accepted form of cancer treatment and technological advances in beam delivery technology (i.e. pencil beam scanning (PBS)) have enabled the application of highly conformal dose distributions to static targets. Current research focuses on the possibilities for the t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/22/7905

    authors: Bernatowicz K,Lomax AJ,Knopf A

    更新日期:2013-11-21 00:00:00

  • Effects of pulmonary inhalation on hyperpolarized krypton-83 magnetic resonance T1 relaxation.

    abstract::The (83)Kr magnetic resonance (MR) relaxation time T(1) of krypton gas in contact with model surfaces was previously found to be highly sensitive to surface composition, surface-to-volume ratio, and surface temperature. The work presented here explored aspects of pulmonary (83)Kr T(1) relaxation measurements in excise...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/13/001

    authors: Stupic KF,Elkins ND,Pavlovskaya GE,Repine JE,Meersmann T

    更新日期:2011-07-07 00:00:00

  • On the dosimetric behaviour of photon dose calculation algorithms in the presence of simple geometric heterogeneities: comparison with Monte Carlo calculations.

    abstract::A comparative study was performed to reveal differences and relative figures of merit of seven different calculation algorithms for photon beams when applied to inhomogeneous media. The following algorithms were investigated: Varian Eclipse: the anisotropic analytical algorithm, and the pencil beam with modified Batho...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/5/011

    authors: Fogliata A,Vanetti E,Albers D,Brink C,Clivio A,Knöös T,Nicolini G,Cozzi L

    更新日期:2007-03-07 00:00:00

  • Biological dosimetry of complex ion radiation fields.

    abstract::We report on a set of cell survival experiments performed in complex field combinations of therapeutic 12C ion beams. CHO cells were exposed to the superposition of two or three fields of 12C ions arranged in a similar way to real patient treatments. Two-dimensional survival distributions were measured and compared wi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/14/302

    authors: Krämer M,Wang JF,Weyrather W

    更新日期:2003-07-21 00:00:00

  • Factors affecting the repeatability of gamma camera calibration for quantitative imaging applications using a sealed source.

    abstract::Several applications in nuclear medicine require absolute activity quantification of single photon emission computed tomography images. Obtaining a repeatable calibration factor that converts voxel values to activity units is essential for these applications. Because source preparation and measurement of the source ac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/3/1325

    authors: Anizan N,Wang H,Zhou XC,Wahl RL,Frey EC

    更新日期:2015-02-07 00:00:00

  • Optimization of a depth of interaction encoding PET block detector for a PET/MRI insert.

    abstract::Preclinical positron emission tomography, combined with magnetic resonance imaging (PET/MRI), is increasingly used as a tool to simultaneously characterize functional processes in vivo. Many emerging preclinical applications, however, are limited by PET detection sensitivity, especially when generating short imaging f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaef59

    authors: Selfridge AR,Cherry SR,Judenhofer MS

    更新日期:2018-12-06 00:00:00

  • Quantitation in SPECT using an effective model of the scattering.

    abstract::A new method for correcting simultaneously the attenuation, scatter and resolution effects in SPECT has been developed for the case of a homogeneous medium. It is based on an effective model of the scatter process. This model depends on only four parameters which are determined experimentally and remain independent of...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/4/005

    authors: Walrand SH,van Elmbt LR,Pauwels S

    更新日期:1994-04-01 00:00:00

  • On the accuracy and effectiveness of dose reconstruction for tomotherapy.

    abstract::Dose reconstruction is a process that re-creates the treatment-time dose deposited in a patient provided there is knowledge of the delivered energy fluence and the patient's anatomy at the time of treatment. A method for reconstructing dose is presented. The process starts with delivery verification, in which the inci...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/4/303

    authors: Kapatoes JM,Olivera GH,Balog JP,Keller H,Reckwerdt PJ,Mackie TR

    更新日期:2001-04-01 00:00:00

  • Quantitative imaging of coronary flows using 3D ultrafast Doppler coronary angiography.

    abstract::Coronary flow rate remains complex to assess in clinical practice using non-invasive, non-ionizing imaging tools. In this study, we introduce 3D ultrafast Doppler coronary angiography (3D UDCA), an ultrasound-based method to assess coronary blood flows in three-dimensions at high volume-rate and in one single heartbea...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8d78

    authors: Correia M,Maresca D,Goudot G,Villemain O,Bizé A,Sambin L,Tanter M,Ghaleh B,Pernot M

    更新日期:2020-06-05 00:00:00

  • Monte Carlo-based diffusion tensor tractography with a geometrically corrected voxel-centre connecting method.

    abstract::Diffusion tensor tractography (DTT) allows one to explore axonal connectivity patterns in neuronal tissue by linking local predominant diffusion directions determined by diffusion tensor imaging (DTI). The majority of existing tractography approaches use continuous coordinates for calculating single trajectories throu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/4/013

    authors: Bodammer NC,Kaufmann J,Kanowski M,Tempelmann C

    更新日期:2009-02-21 00:00:00