Effects of tissue mechanical and acoustic anisotropies on the performance of a cross-correlation-based ultrasound strain imaging method.

Abstract:

:The anisotropic mechanical properties (mechanical anisotropy) and view-dependent ultrasonic backscattering (acoustic anisotropy) of striated muscle due to the underlying myofiber arrangement have been well documented, but whether they impact on ultrasound strain imaging (USI) techniques remains unclear. The aim of this study was therefore to investigate the performance of a cross-correlation-based two-dimensional (2D) USI method in anisotropic media under controlled quasi-static compression in silico and in vitro. First, synthetic pre- and post-deformed 2D radiofrequency images of anisotropic phantoms were simulated in two scenarios to examine the individual effect of the mechanical and acoustic anisotropies on strain estimation. In the first scenario, the phantom was defined to be transversely isotropic with the scatterer amplitudes following a zero-mean Gaussian distribution, while in the second scenario, the phantom was defined to be mechanically isotropic with Gaussian distributed scatterer amplitudes correlated along the principal directions of pre-defined fibers. These two anisotropies were then jointly incorporated into the ultrasound image simulation model with additional depth-dependent attenuation. Three imaging planes-the fiber plane with the fiber direction perpendicular to the ultrasound beam (TISperp_fb), the fiber plane with the fiber direction parallel to the beam (TISpara), and the transverse fiber plane (TISperp_cfb)-were studied. The absolute relative error (ARE) of the lateral strain estimates in TISperp_fb (20.99  ±  15.65%) was much higher than that in TISperp_cfb (4.14  ±  3.17%). The ARE in TISpara was unavailable owing to the large spatial extent of false peaks. The effect of tissue anisotropy on the performance of the 2D USI was further confirmed in an in vitro porcine skeletal muscle phantom. The best in-plane strain quality was again shown in TISperp_cfb (elastographic signal-to-noise ratio, or SNRe:  >25 dB), whereas the most unreliable strain estimates were found as expected in TISpara (SNRe:  <10 dB). The strain filter explained the effect of the mechanical anisotropy and required the underlying strain to be within an optimal range for estimation. Sonographic SNR (SNRs) was found to be altered by the acoustic anisotropy and was much lower in TISpara (~10 dB) than in TISperp_fb (~50 dB) in vitro, which affected the accuracy of the strain estimation. Speckle size showed no evident impact on strain estimation but requires further examination.

journal_name

Phys Med Biol

authors

Li H,Lee WN

doi

10.1088/1361-6560/aa530b

subject

Has Abstract

pub_date

2017-02-21 00:00:00

pages

1456-1479

issue

4

eissn

0031-9155

issn

1361-6560

journal_volume

62

pub_type

杂志文章
  • A new method to reconstruct intra-fractional prostate motion in volumetric modulated arc therapy.

    abstract::Intra-fractional motion is a concern during prostate radiation therapy, as it may cause deviations between planned and delivered radiation doses. Because accurate motion information during treatment delivery is critical to address dose deviation, we developed the projection marker matching method (PM3), a novel method...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6e37

    authors: Chi Y,Rezaeian NH,Shen C,Zhou Y,Lu W,Yang M,Hannan R,Jia X

    更新日期:2017-07-07 00:00:00

  • Optimization of fluoroscopy parameters using pattern matching prediction in the real-time tumor-tracking radiotherapy system.

    abstract::In the real-time tumor-tracking radiotherapy system, fluoroscopy is used to determine the real-time position of internal fiducial markers. The pattern recognition score (PRS) ranging from 0 to 100 is computed by a template pattern matching technique in order to determine the marker position on the fluoroscopic image. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/15/011

    authors: Miyamoto N,Ishikawa M,Bengua G,Sutherland K,Suzuki R,Kimura S,Shimizu S,Onimaru R,Shirato H

    更新日期:2011-08-07 00:00:00

  • Volume-selective and spectroscopically resolved NMR investigation of diffusion and relaxation in fertilised hen eggs.

    abstract::A radiofrequency and field-gradient pulse sequence is presented permitting the non-invasive, volume-selective and spectroscopically resolved determination of incoherent transport parameters with the aid of an NMR field-gradient method. With proton NMR, diffusion or (quasi-incoherent) perfusion coefficients as low as 1...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/35/1/007

    authors: Klammler F,Kimmich R

    更新日期:1990-01-01 00:00:00

  • A neural network regression model for relative dose computation.

    abstract::This paper describes a neural network (NN) regression model for relative dose computation. The input signal of the NN model includes depths and field sizes and the output is the relative dose, for example, percentage depth dose (%DD) or tissue-air ratio (TAR) in this paper. After a functional link has been created, th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/4/307

    authors: Wu X,Zhu Y

    更新日期:2000-04-01 00:00:00

  • Scheduling cisplatin and radiotherapy in the treatment of squamous cell carcinomas of the head and neck: a modelling approach.

    abstract::The aim of the present work was to implement the kinetics of cisplatin into a previously developed tumour growth model and to simulate the combined cisplatin-radiotherapy treatment with the emphasis on time sequencing and scheduling of drug and radiation. An investigation into whether the effect of cisplatin-radiation...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/15/002

    authors: Marcu L,Bezak E,Olver I

    更新日期:2006-08-07 00:00:00

  • Real-time tracking of tumor motions and deformations along the leaf travel direction with the aid of a synchronized dynamic MLC leaf sequencer.

    abstract::Advanced radiotherapeutical techniques like intensity-modulated radiation therapy (IMRT) are based on an accurate knowledge of the location of the radiation target. An accurate dose delivery, therefore, requires a method to account for the inter- and intrafractional target motion and the target deformation occurring d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/22/N01

    authors: Tacke M,Nill S,Oelfke U

    更新日期:2007-11-21 00:00:00

  • Integral equations and boundary-element solution for static potential in a general piece-wise homogeneous volume conductor.

    abstract::Boundary element methods (BEM) are used for forward computation of bioelectromagnetic fields in multi-compartment volume conductor models. Most BEM approaches assume that each compartment is in contact with at most one external compartment. In this work, I present a general surface integral equation and BEM discretiza...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/22/N606

    authors: Stenroos M

    更新日期:2016-11-21 00:00:00

  • A multi-frequency sparse hemispherical ultrasound phased array for microbubble-mediated transcranial therapy and simultaneous cavitation mapping.

    abstract::Focused ultrasound (FUS) phased arrays show promise for non-invasive brain therapy. However, the majority of them are limited to a single transmit/receive frequency and therefore lack the versatility to expose and monitor the treatment volume. Multi-frequency arrays could offer variable transmit focal sizes under a fi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/24/8476

    authors: Deng L,O'Reilly MA,Jones RM,An R,Hynynen K

    更新日期:2016-12-21 00:00:00

  • Improvement of the prompt-gamma neutron activation facility at Brookhaven National Laboratory.

    abstract::The prompt-gamma neutron activation facility at Brookhaven National Laboratory was upgraded to improve both the precision and accuracy of its in vivo determinations of total body nitrogen. The upgrade, guided by Monte Carlo simulations, involved elongating and modifying the source collimator and its shielding, reposit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/2/009

    authors: Dilmanian FA,Lidofsky LJ,Stamatelatos I,Kamen Y,Yasumura S,Vartsky D,Pierson RN Jr,Weber DA,Moore RI,Ma R

    更新日期:1998-02-01 00:00:00

  • Algorithm and performance of a clinical IMRT beam-angle optimization system.

    abstract::This paper describes the algorithm and examines the performance of an intensity-modulated radiation therapy (IMRT) beam-angle optimization (BAO) system. In this algorithm successive sets of beam angles are selected from a set of predefined directions using a fast simulated annealing (FSA) algorithm. An IMRT beam-profi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/19/007

    authors: Djajaputra D,Wu Q,Wu Y,Mohan R

    更新日期:2003-10-07 00:00:00

  • A novel technique for measuring the low-dose envelope of pencil-beam scanning spot profiles.

    abstract::To investigate the profile measurement capabilities of an IBA-Dosimetry scintillation detector and to assess its feasibility for determining the low-intensity tails of pencil-beam scanning spots, the responses of the scintillation detector and Gafchromic EBT2 film to a 115 MeV proton spot were measured in-air at the i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/12/N171

    authors: Lin L,Ainsley CG,Mertens T,De Wilde O,Talla PT,McDonough JE

    更新日期:2013-06-21 00:00:00

  • Measurement of calcium in sections of a human skeleton using a reactor spectrum-in vivo activation analysis technique.

    abstract::Factors influencing the precision of measuring changes in the calcium content of sections of bone, including vertebrae, using reactor neutrons for partial body in vivo activation analysis have been examined and quantified. These factors include (a) the choice of incidient neutron spectrum, (b) the uniformity of activa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/20/1/007

    authors: Boddy K,Glaros D,Robertson I

    更新日期:1975-01-01 00:00:00

  • Systematic variations in polymer gel dosimeter calibration due to container influence and deviations from water equivalence.

    abstract::There are a number of gel dosimeter calibration methods in contemporary usage. The present study is a detailed Monte Carlo investigation into the accuracy of several calibration techniques. Results show that for most arrangements the dose to gel accurately reflects the dose to water, with the most accurate method invo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/13/022

    authors: Taylor ML,Franich RD,Johnston PN,Millar RM,Trapp JV

    更新日期:2007-07-07 00:00:00

  • Scattering kernels for fast neutron therapy treatment planning.

    abstract::The University of Washington (UW) Clinical Neutron Therapy System (CNTS) has been used to treat over 3300 patients. Treatment planning for these patients is currently performed using an MV x-ray model in Pinnacle® adapted to fit measurements of fast neutron output factors, wedge factors, depth-dose and lateral profile...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9a85

    authors: Moffitt GB,Wootton LS,Hårdemark B,Sandison GA,Laramore GE,Parvathaneni U,Stewart RD

    更新日期:2020-08-31 00:00:00

  • Pulsed focused ultrasound lowers interstitial fluid pressure and increases nanoparticle delivery and penetration in head and neck squamous cell carcinoma xenograft tumors.

    abstract::Nanocarriers offer a promising approach to significantly improve therapeutic delivery to solid tumors as well as limit the side effects associated with anti-cancer agents. However, their relatively large size can negatively affect their ability to efficiently penetrate into more interior tumor regions, ultimately redu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9705

    authors: Mohammadabadi A,Huynh RN,Wadajkar AS,Lapidus RG,Kim AJ,Raub CB,Frenkel V

    更新日期:2020-06-22 00:00:00

  • Convex reformulation of biologically-based multi-criteria intensity-modulated radiation therapy optimization including fractionation effects.

    abstract::Finding fluence maps for intensity-modulated radiation therapy (IMRT) can be formulated as a multi-criteria optimization problem for which Pareto optimal treatment plans exist. To account for the dose-per-fraction effect of fractionated IMRT, it is desirable to exploit radiobiological treatment plan evaluation criteri...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/22/006

    authors: Hoffmann AL,den Hertog D,Siem AY,Kaanders JH,Huizenga H

    更新日期:2008-11-21 00:00:00

  • Kinetic filtering of [(18)F]Fluorothymidine in positron emission tomography studies.

    abstract::[(18)F]Fluorothymidine (FLT) is a cell proliferation marker that undergoes predominantly hepatic metabolism and therefore shows a high level of accumulation in the liver, as well as in rapidly proliferating tumours. Furthermore, the tracer's uptake is substantial in other organs including the heart. We present a nonli...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/3/010

    authors: Gray KR,Contractor KB,Kenny LM,Al-Nahhas A,Shousha S,Stebbing J,Wasan HS,Coombes RC,Aboagye EO,Turkheimer FE,Rosso L

    更新日期:2010-02-07 00:00:00

  • The effect of temporal HU variations on the uncertainty of dose recalculations performed on MVCT images.

    abstract::Over the course of radiation therapy, a patient's anatomy may change substantially. The relatively recent addition of frequent in-room imaging to assist with patient localization has provided a database of images that may be used to recalculate dose distributions for adaptive radiotherapy purposes. The TomoTherapy Hi-...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/24/010

    authors: Pukala J,Meeks SL,Bova FJ,Langen KM

    更新日期:2011-12-21 00:00:00

  • Comparison of simultaneous and sequential SPECT imaging for discrimination tasks in assessment of cardiac defects.

    abstract::Simultaneous rest perfusion/fatty-acid metabolism studies have the potential to replace sequential rest/stress perfusion studies for the assessment of cardiac function. Simultaneous acquisition has the benefits of increased signal and lack of need for patient stress, but is complicated by cross-talk between the two ra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/22/019

    authors: Trott CM,Ouyang J,El Fakhri G

    更新日期:2010-11-21 00:00:00

  • Significance of background optical properties, time-resolved information and optode arrangement in diffuse optical imaging of term neonates.

    abstract::The significance of accurate knowledge of background optical properties and time-resolved information in reconstructing images of hemodynamic changes in the neonatal brain from diffuse optical imaging data was studied using Monte Carlo (MC) simulation. A segmented anatomical magnetic resonance (MR) image and literatur...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/3/005

    authors: Heiskala J,Hiltunen P,Nissilä I

    更新日期:2009-02-07 00:00:00

  • Characterization of optical parameters with a human forearm at the region from 1.15 to 1.52 microm using diffuse reflectance measurements.

    abstract::Time- and space-resolved diffuse reflectance measurements were used to identify the optical parameters, the reduced scattering and absorption coefficients, of bulk living tissue in the region from 1.15 to 1.52 microm. Although in this region the detector was limited in its temporal resolution, we applied a peak-time s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/11/021

    authors: Nishimura G,Kida I,Tamura M

    更新日期:2006-06-07 00:00:00

  • Arc-modulated radiation therapy based on linear models.

    abstract::This paper reports an inverse arc-modulated radiation therapy planning technique based on linear models. It is implemented with a two-step procedure. First, fluence maps for 36 fixed-gantry beams are generated using a linear model-based intensity-modulated radiation therapy (IMRT) optimization algorithm. The 2D fluenc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/13/020

    authors: Zhu X,Thongphiew D,McMahon R,Li T,Chankong V,Yin FF,Wu QJ

    更新日期:2010-07-07 00:00:00

  • Positron range in PET imaging: an alternative approach for assessing and correcting the blurring.

    abstract::Positron range impairs resolution in PET imaging, especially for high-energy emitters and for small-animal PET. De-blurring in image reconstruction is possible if the blurring distribution is known. Furthermore, the percentage of annihilation events within a given distance from the point of positron emission is releva...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/12/3931

    authors: Jødal L,Le Loirec C,Champion C

    更新日期:2012-06-21 00:00:00

  • Sensitivity of different dose scoring methods on organ-specific neutron dose calculations in proton therapy.

    abstract::Scattered doses, e.g. neutron doses in proton therapy, are of concern in radiation therapy. Although measured data are the gold standard, Monte Carlo simulations allow a more realistic consideration of patient anatomy via whole-body phantoms. When calculating neutron doses with Monte Carlo techniques, the dose can be ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/17/004

    authors: Jarlskog CZ,Paganetti H

    更新日期:2008-09-07 00:00:00

  • Feasibility study of range verification based on proton-induced acoustic signals and recurrent neural network.

    abstract::Range verification in proton therapy is a critical quality assurance task. We studied the feasibility of online range verification based on proton-induced acoustic signals, using a bidirectional long-short-term-memory recurrent neural network and various signal processing techniques. Dose distribution of 1D pencil pro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abaa5e

    authors: Yao S,Hu Z,Zhang X,Lou E,Liang Z,Wang Y,Peng H

    更新日期:2020-11-05 00:00:00

  • Automatic classification of DMSA scans using an artificial neural network.

    abstract::DMSA imaging is carried out in nuclear medicine to assess the level of functional renal tissue in patients. This study investigated the use of an artificial neural network to perform diagnostic classification of these scans. Using the radiological report as the gold standard, the network was trained to classify DMSA s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/7/1789

    authors: Wright JW,Duguid R,McKiddie F,Staff RT

    更新日期:2014-04-07 00:00:00

  • An investigation and explanation of the fall-off of x-ray tube current during an exposure.

    abstract::It was observed that the radiation output of x-ray tubes falls off exponentially during an exposure with a time constant of about 120 ms. The equilibrium value is approximately 15% lower than that at the beginning of the exposure. The clinically noticeable consequences are discrepancies in x-ray generator calibration,...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/2/004

    authors: Brezovich IA,Barnes GT

    更新日期:1980-03-01 00:00:00

  • Leuco-crystal-violet micelle gel dosimeters: I. Influence of recipe components and potential sensitizers.

    abstract::Radiochromic leuco crystal violet (LCV) micelle gel dosimeters are promising three-dimensional radiation dosimeters because of their spatial stability and suitability for optical readout. The effects of surfactant type and surfactant concentration on dose sensitivity of LCV micelle gels are tested, demonstrating that ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/12/4665

    authors: Nasr AT,Alexander K,Schreiner LJ,McAuley KB

    更新日期:2015-06-21 00:00:00

  • Measuring the acoustoelectric interaction constant using ultrasound current source density imaging.

    abstract::Ultrasound current source density imaging (UCSDI) exploits the acoustoelectric (AE) effect, an interaction between ultrasound pressure and electrical resistivity, to map electrical conduction in the heart. The conversion efficiency for UCSDI is determined by the AE interaction constant K, a fundamental property of all...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/19/5929

    authors: Li Q,Olafsson R,Ingram P,Wang Z,Witte R

    更新日期:2012-10-07 00:00:00

  • Comparison of a finite-element multigroup discrete-ordinates code with Monte Carlo for radiotherapy calculations.

    abstract::Radiotherapy calculations often involve complex geometries such as interfaces between materials of vastly differing atomic number, such as lung, bone and/or air interfaces. Monte Carlo methods have been used to calculate accurately the perturbation effects of the interfaces. However, these methods can be computational...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/9/010

    authors: Gifford KA,Horton JL,Wareing TA,Failla G,Mourtada F

    更新日期:2006-05-07 00:00:00