Dosimetric consequences of tumour motion due to respiration for a scanned proton beam.

Abstract:

:A method for simulating spot-scanned delivery to a moving tumour was developed which uses patient-specific image and plan data. The magnitude of interplay effects was investigated for two patient cases under different fractionation and respiratory motion variation scenarios. The use of volumetric rescanning for motion mitigation was also investigated. For different beam arrangements, interplay effects lead to severely distorted dose distributions for a single fraction delivery. Baseline shift variations for single fraction delivery reduced the dose to the clinical target volume (CTV) by up to 14.1 Gy. Fractionated delivery significantly reduced interplay effects; however, local overdosage of 12.3% compared to the statically delivered dose remained for breathing period variations. Variations of the tumour baseline position and respiratory period were found to have the largest influence on target inhomogeneity; these effects were reduced with fractionation. Volumetric rescanning improved the dose homogeneity. For the CTV, underdosage was improved by up to 34% in the CTV and overdosage to the lung was reduced by 6%. Our results confirm that rescanning potentially increases the dose homogeneity; however, it might not sufficiently compensate motion-induced dose distortions. Other motion mitigation techniques may be required to additionally treat lung tumours with scanned proton beams.

journal_name

Phys Med Biol

authors

Kraus KM,Heath E,Oelfke U

doi

10.1088/0031-9155/56/20/003

subject

Has Abstract

pub_date

2011-10-21 00:00:00

pages

6563-81

issue

20

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(11)92900-5

journal_volume

56

pub_type

杂志文章
  • Clinical ultraviolet dosimetry with a CCD monochromator array spectroradiometer.

    abstract::Single monochromator charge-coupled device (CCD) array spectroradiometers have the advantage of ease of use and speed compared with double grating instruments. Their inherently inferior stray-light rejection, however, can critically affect their accuracy in phototherapy and research-related dosimetry applications. Thi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/18/026

    authors: Coleman A,Sarkany R,Walker S

    更新日期:2008-09-21 00:00:00

  • Fast and exact Hessian computation for a class of nonlinear functions used in radiation therapy treatment planning.

    abstract::In nonlinear optimisation, using exact Hessian computations (full-Newton) hold superior convergence properties over quasi-Newton methods or gradient-based methods. However, for medium-scale problems, computing the Hessian can be computationally expensive and thus time-consuming. For solvers dedicated to a specific pro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab1e17

    authors: van Haveren R,Breedveld S

    更新日期:2019-08-14 00:00:00

  • The energy response of a T.P.A. Mk-II ionization chamber using GEANT4 Monte Carlo simulation.

    abstract::The low energy model of the GEANT4 Monte Carlo toolkit was used to simulate the energy response of a T.P.A. Mk-II ionization chamber under a variety of different conditions. The sample position resulting in the maximum response along the axial direction of the chamber was obtained. The parameters of the simulation wer...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/13/012

    authors: Seneviratne MD,Reinhard MI,Baldock C

    更新日期:2007-07-07 00:00:00

  • An analysis of beam parameters on proton-acoustic waves through an analytic approach.

    abstract::It has been reported that acoustic waves are generated when a high-energy pulsed proton beam is deposited in a small volume within tissue. One possible application of proton-induced acoustics is to get real-time feedback for intra-treatment adjustments by monitoring such acoustic waves. A high spatial resolution in ul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa642c

    authors: Kipergil EA,Erkol H,Kaya S,Gulsen G,Unlu MB

    更新日期:2017-06-21 00:00:00

  • Ultrasound scattering from spherical tumours.

    abstract::The interaction of biomedical ultrasound with spherical tumours in the human body is investigated using analytic methods which predict the angular distribution of the ultrasound scattered by the tumour. Both the tumour and the surrounding tissue are considered to be lossy elastic media, which support shear-wave modes ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/11/001

    authors: Hinders MK,Collins JJ,Collins MM,Fang TM,Sandri GV

    更新日期:1992-11-01 00:00:00

  • Enhancement of subharmonic emission from encapsulated microbubbles by using a chirp excitation technique.

    abstract::Subharmonic contrast imaging promises to improve ultrasound-imaging quality by taking advantage of an increased contrast to tissue signal. However, acoustic pressures beyond the subharmonic generation threshold using common ultrasound pulses may induce significant contrast microbubble destruction. In this work, a chir...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/18/005

    authors: Zhang D,Gong Y,Gong X,Liu Z,Tan K,Zheng H

    更新日期:2007-09-21 00:00:00

  • Monte Carlo modelling of electron beams from medical accelerators.

    abstract::Monte Carlo simulation of radiation transport is considered to be one of the most accurate methods of radiation therapy dose calculation. With the rapid development of computer technology, Monte Carlo based treatment planning for radiation therapy is becoming practical. A basic requirement for Monte Carlo treatment pl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/44/12/201

    authors: Ma CM,Jiang SB

    更新日期:1999-12-01 00:00:00

  • Numerical model of heat transfer in the human eye with consideration of fluid dynamics of the aqueous humour.

    abstract::In this work we present a new 3D numerical model for heat transfer in the human eye, which takes into account the aqueous humour flow in the anterior chamber. We show that consideration of this phenomenon in the calculations alters the temperature distribution on the corneal and lens surfaces, without, however, notice...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/19/003

    authors: Karampatzakis A,Samaras T

    更新日期:2010-10-07 00:00:00

  • Accurate Monte Carlo calculations of the combined attenuation and build-up factors, for energies (20-1500 keV) and distances (0-10 cm) relevant in brachytherapy.

    abstract::The combined build-up and attenuation factor, B exp (-mu r), of point isotropic photon sources in a water medium has been calculated using the Monte Carlo method, for energies (20-1500 keV) and distances (1-10 cm) relevant in brachytherapy. For the transport of photons and electrons, up-to-date and self-consistent tot...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/6/005

    authors: Angelopoulos A,Perris A,Sakellariou K,Sakelliou L,Sarigiannis K,Zarris G

    更新日期:1991-06-01 00:00:00

  • Pre- and post-natal exposure of children to EMF generated by domestic induction cookers.

    abstract::Induction cookers are a type of cooking appliance that uses an intermediate-frequency magnetic field to heat the cooking vessel. The magnetic flux density produced by an induction cooker during operation was measured according to the EN 62233 standard, and the measured values were below the limits set in the standard....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/19/001

    authors: Kos B,Valič B,Miklavčič D,Kotnik T,Gajšek P

    更新日期:2011-10-07 00:00:00

  • The quality of ionising radiations emitted by radionuclides incorporated into mammalian cells.

    abstract::Radionuclides which decay by electron capture accompanied by Auger electron cascades, or by beta emission are thought to be excessively damaging when incorporated into the molecular structure of mammalian cell nuclei and thereby pose a radiation hazard which is not assessable by conventional dosimetry. Survival data, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/7/003

    authors: Younis AR,Watt DE

    更新日期:1989-07-01 00:00:00

  • Residual motion compensation in ECG-gated interventional cardiac vasculature reconstruction.

    abstract::Three-dimensional reconstruction of cardiac vasculature from angiographic C-arm CT (rotational angiography) data is a major challenge. Motion artefacts corrupt image quality, reducing usability for diagnosis and guidance. Many state-of-the-art approaches depend on retrospective ECG-gating of projection data for image ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/11/3717

    authors: Schwemmer C,Rohkohl C,Lauritsch G,Müller K,Hornegger J

    更新日期:2013-06-07 00:00:00

  • Simulated lesion, human observer performance comparison between thin-section dedicated breast CT images versus computed thick-section simulated projection images of the breast.

    abstract::The objective of this study was to compare the lesion detection performance of human observers between thin-section computed tomography images of the breast, with thick-section (>40 mm) simulated projection images of the breast. Three radiologists and six physicists each executed a two alterative force choice (2AFC) s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/8/3347

    authors: Chen L,Boone JM,Abbey CK,Hargreaves J,Bateni C,Lindfors KK,Yang K,Nosratieh A,Hernandez A,Gazi P

    更新日期:2015-04-21 00:00:00

  • Comparison of Geant4 multiple Coulomb scattering models with theory for radiotherapy protons.

    abstract::Usually, Monte Carlo models are validated against experimental data. However, models of multiple Coulomb scattering (MCS) in the Gaussian approximation are exceptional in that we have theories which are probably more accurate than the experiments which have, so far, been done to test them. In problems directly sensiti...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6ce3

    authors: Makarova A,Gottschalk B,Sauerwein W

    更新日期:2017-07-06 00:00:00

  • Learning image based surrogate relevance criterion for atlas selection in segmentation.

    abstract::Picking geometrically relevant atlases from the whole training set is crucial to multi-atlas based image segmentation, especially with extensive data of heterogeneous quality in the Big Data era. Unfortunately, there is very limited understanding of how currently used image similarity criteria reveal geometric relevan...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/11/4223

    authors: Zhao T,Ruan D

    更新日期:2016-06-07 00:00:00

  • Reconstructing NMR images from projections under inhomogeneous magnetic field and non-linear field gradients.

    abstract::Both inhomogeneity in the main magnetic field and non-linearity in the gradient fields introduce errors in NMR images reconstructed from projections. It is found that the image artefacts caused by these two sources are separable. The inhomogeneous main field blurs the image while the nonlinear gradients distort the im...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/28/8/005

    authors: Lai CM

    更新日期:1983-08-01 00:00:00

  • Radioisotopic purity and imaging properties of cyclotron-produced 99mTc using direct 100Mo(p,2n) reaction.

    abstract::Evaluation of the radioisotopic purity of technetium-99m (99mTc) produced in GBq amounts by proton bombardment of enriched molibdenum-100 (100Mo) metallic targets at low proton energies (i.e. within 15-20 MeV) is conducted. This energy range was chosen since it is easily achievable by many conventional medical cyclotr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aadc88

    authors: Uzunov NM,Melendez-Alafort L,Bello M,Cicoria G,Zagni F,De Nardo L,Selva A,Mou L,Rossi-Alvarez C,Pupillo G,Di Domenico G,Uccelli L,Boschi A,Groppi F,Salvini A,Taibi A,Duatti A,Martini P,Pasquali M,Loriggiola M,Mare

    更新日期:2018-09-19 00:00:00

  • On the correction, perturbation and modification of small field detectors in relative dosimetry.

    abstract::The purpose of this study was to derive a complete set of correction and perturbation factors for output factors (OF) and dose profiles. Modern small field detectors were investigated including a plastic scintillator (Exradin W1, SI), a liquid ionization chamber (microLion 31018, PTW), an unshielded diode (Exradin D1V...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/19/5937

    authors: Papaconstadopoulos P,Tessier F,Seuntjens J

    更新日期:2014-10-07 00:00:00

  • Investigation of detection limits for diffuse optical tomography systems: II. Analysis of slab and cup geometry for breast imaging.

    abstract::Using a statistical (chi-square) test on simulated data and a realistic noise model derived from the system's hardware we study the performance of diffuse optical tomography systems for fluorescence imaging. We compare the predicted smallest size of detectable lesions at various positions in slab and cup geometry and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/2/016

    authors: Ziegler R,Brendel B,Rinneberg H,Nielsen T

    更新日期:2009-01-21 00:00:00

  • Evaluation of radiochromic gel dosimetry and polymer gel dosimetry in a clinical dose verification.

    abstract::A quantitative comparison of two full three-dimensional (3D) gel dosimetry techniques was assessed in a clinical setting: radiochromic gel dosimetry with an in-house developed optical laser CT scanner and polymer gel dosimetry with magnetic resonance imaging (MRI). To benchmark both gel dosimeters, they were exposed t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/18/6241

    authors: Vandecasteele J,De Deene Y

    更新日期:2013-09-21 00:00:00

  • On the total system error of a robotic radiosurgery system: phantom measurements, clinical evaluation and long-term analysis.

    abstract::The total system error (TSE) of a CyberKnife® system was measured using two phantom-based methods and one patient-based method. The standard radiochromic film (RCF) end-to-end (E2E) test using an anthropomorphic head and neck phantom and isocentric treatment delivery was used with the 6Dskull, Fiducial and Xsight® spi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad516

    authors: Pantelis E,Moutsatsos A,Antypas C,Zoros E,Pantelakos P,Lekas L,Romanelli P,Zourari K,Hourdakis CJ

    更新日期:2018-08-20 00:00:00

  • Global point signature for shape analysis of carpal bones.

    abstract::We present a method based on spectral theory for the shape analysis of carpal bones of the human wrist. We represent the cortical surface of the carpal bone in a coordinate system based on the eigensystem of the two-dimensional Helmholtz equation. We employ a metric--global point signature (GPS)--that exploits the sca...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/4/961

    authors: Chaudhari AJ,Leahy RM,Wise BL,Lane NE,Badawi RD,Joshi AA

    更新日期:2014-02-21 00:00:00

  • Population and patient-specific target margins for 4D adaptive radiotherapy to account for intra- and inter-fraction variation in lung tumour position.

    abstract::In this work, five 4D image-guidance strategies (two population, an offline adaptive and two online strategies) were evaluated that compensated for both inter- and intra-fraction variability such as changes to the baseline tumour position and respiratory pattern. None of the strategies required active motion compensat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/1/017

    authors: Hugo GD,Yan D,Liang J

    更新日期:2007-01-07 00:00:00

  • Comparison of a finite-element multigroup discrete-ordinates code with Monte Carlo for radiotherapy calculations.

    abstract::Radiotherapy calculations often involve complex geometries such as interfaces between materials of vastly differing atomic number, such as lung, bone and/or air interfaces. Monte Carlo methods have been used to calculate accurately the perturbation effects of the interfaces. However, these methods can be computational...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/9/010

    authors: Gifford KA,Horton JL,Wareing TA,Failla G,Mourtada F

    更新日期:2006-05-07 00:00:00

  • Leuco-crystal-violet micelle gel dosimeters: I. Influence of recipe components and potential sensitizers.

    abstract::Radiochromic leuco crystal violet (LCV) micelle gel dosimeters are promising three-dimensional radiation dosimeters because of their spatial stability and suitability for optical readout. The effects of surfactant type and surfactant concentration on dose sensitivity of LCV micelle gels are tested, demonstrating that ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/12/4665

    authors: Nasr AT,Alexander K,Schreiner LJ,McAuley KB

    更新日期:2015-06-21 00:00:00

  • Planning 4D intensity-modulated arc therapy for tumor tracking with a multileaf collimator.

    abstract::This study introduces a practical four-dimensional (4D) planning scheme of IMAT using 4D computed tomography (4D CT) for planning tumor tracking with dynamic multileaf beam collimation. We assume that patients can breathe regularly, i.e. the same way as during 4D CT with an unchanged period and amplitude, and that the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa56b7

    authors: Niu Y,Betzel GT,Yang X,Gui M,Parke WC,Yi B,Yu CX

    更新日期:2017-02-21 00:00:00

  • Novel method to calculate pulmonary compliance images in rodents from computed tomography acquired at constant pressures.

    abstract::Our goal was to develop a method for generating high-resolution three-dimensional pulmonary compliance images in rodents from computed tomography (CT) images acquired at a series of constant pressures in ventilated animals. One rat and one mouse were used to demonstrate this technique. A pre-clinical GE flat panel CT ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/5/003

    authors: Guerrero T,Castillo R,Sanders K,Price R,Komaki R,Cody D

    更新日期:2006-03-07 00:00:00

  • A hybrid scatter correction for 3D PET based on an estimation of the distribution of unscattered coincidences: implementation on the ECAT EXACT HR+.

    abstract::We implemented a hybrid scatter-correction method for 3D PET that combines two scatter-correction methods in a complementary way. The implemented scheme uses a method based on the discrimination of the energy of events (the estimation of trues method (ETM)) and an auxiliary method (the single scatter simulation method...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/9/310

    authors: Ferreira NC,Trébossen R,Lartizien C,Brulon V,Merceron P,Bendriem B

    更新日期:2002-05-07 00:00:00

  • On the accuracy and effectiveness of dose reconstruction for tomotherapy.

    abstract::Dose reconstruction is a process that re-creates the treatment-time dose deposited in a patient provided there is knowledge of the delivered energy fluence and the patient's anatomy at the time of treatment. A method for reconstructing dose is presented. The process starts with delivery verification, in which the inci...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/4/303

    authors: Kapatoes JM,Olivera GH,Balog JP,Keller H,Reckwerdt PJ,Mackie TR

    更新日期:2001-04-01 00:00:00

  • Dose conversion coefficients for CT examinations of adults with automatic tube current modulation.

    abstract::Automatic tube current modulation (TCM) is used in modern CT devices. This is implemented in the numerical calculation of dose conversion coefficients for CT examinations. For four models of adults, the female and male reference models of ICRP and ICRU and a lighter and a heavier female model, dose conversion coeffici...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/20/013

    authors: Schlattl H,Zankl M,Becker J,Hoeschen C

    更新日期:2010-10-21 00:00:00