Sensitivity study of the microdosimetric kinetic model parameters for carbon ion radiotherapy.

Abstract:

:In carbon ion therapy treatment planning, the relative biological effectiveness (RBE) is accounted for by optimization of the RBE-weighted dose (biological dose). The RBE calculation methods currently applied clinically in carbon ion therapy are derived from the microdosimetric kinetic model (MKM) in Japan and the local effect model (LEM) in Europe. The input parameters of these models are based on fit to experimental data subjected to uncertainties. We therefore performed a sensitivity study of the MKM input parameters, i.e. the domain radius (r d ), the nucleus radius (R n ) and the parameters of the linear quadratic (LQ) model (α x and β). The study was performed with the FLUKA Monte Carlo code, using spread out Bragg peak (SOBP) scenarios in water and a biological dose distribution in a clinical patient case. Comparisons were done between biological doses estimated applying the MKM with parameters based on HSG cells, and with HSG parameters varied separately by  ±{5, 25, 50}%. Comparisons were also done between parameter sets from different cell lines (HSG, V79, CHO and T1), as well as versions of the LEM. Of the parameters, r d had the largest impact on the biological dose distribution, especially on the absolute dose values. Increasing this parameter by 25% decreased the biological dose level at the center of a 3 Gy(RBE) SOBP by 14%. Variations in R n only influenced the biological dose distribution towards the particle range, and variations in α x resulted in minor changes in the biological dose, with an increasing impact towards the particle range. β had the overall smallest influence on the SOBPs, but the impact could become more pronounced if alternative (LET dependent) implementations are used. The resulting percentage change in the SOBPs was generally less than the percentage change in the parameters. The patient case showed similar effects as with the SOBPs in water, and parameter variations had similar impact on the biological dose when using the clinical MKM and the general MKM. The clinical LEM calculated the highest biological doses to both tumor and surrounding healthy tissues, with a median target dose (D 50%) of 40.5 Gy(RBE), while the MKM with HSG and V79 parameters resulted in a D 50% of 34.2 and 36.9 Gy(RBE), respectively. In all, the observed change in biological dose distribution due to parameter variations demonstrates the importance of accurate input parameters when applying the MKM in treatment planning.

journal_name

Phys Med Biol

authors

Dahle TJ,Magro G,Ytre-Hauge KS,Stokkevåg CH,Choi K,Mairani A

doi

10.1088/1361-6560/aae8b4

subject

Has Abstract

pub_date

2018-11-12 00:00:00

pages

225016

issue

22

eissn

0031-9155

issn

1361-6560

journal_volume

63

pub_type

杂志文章
  • An analysis of breast motion using high-frequency, dense surface points captured by an optical sensor during radiotherapy treatment delivery.

    abstract::Patient motion is an important factor affecting the quality of external beam radiotherapy in breast patients. We analyse the motion of a dense set of surface points on breast patients throughout their treatment schedule to assess the magnitude and stability of motion, in particular, with respect to breast volume. We u...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/21/005

    authors: Price GJ,Sharrock PJ,Marchant TE,Parkhurst JM,Burton D,Jain P,Price P,Moore CJ

    更新日期:2009-11-07 00:00:00

  • Building an open-source simulation platform of acoustic radiation force-based breast elastography.

    abstract::Ultrasound-based elastography including strain elastography, acoustic radiation force impulse (ARFI) imaging, point shear wave elastography and supersonic shear imaging (SSI) have been used to differentiate breast tumors among other clinical applications. The objective of this study is to extend a previously published...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa58c9

    authors: Wang Y,Peng B,Jiang J

    更新日期:2017-03-07 00:00:00

  • Wavelet-packet-based texture analysis for differentiation between benign and malignant liver tumours in ultrasound images.

    abstract::The purpose of this study was to apply a novel method of multiscale echo texture analysis for distinguishing benign (hemangiomas) from malignant (hepatocellular carcinomas (HCCs) and metastases) focal liver lesions in B-mode ultrasound images. In this method, regions of interest (ROIs) extracted from within the lesion...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/22/008

    authors: Yoshida H,Casalino DD,Keserci B,Coskun A,Ozturk O,Savranlar A

    更新日期:2003-11-21 00:00:00

  • The use of narrowband ultrasound for characterization of tissue in a thin layer.

    abstract::Most tissue characterization methods use RF data originating from backscattering processes in the insonified tissue. Characterization of the tissue of a thin layer (e.g., an artery wall) poses problems because of the small amount of data available. The tissue layer may be so thin that there are no RF data that are not...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/10/002

    authors: Linssen FM,Hoeks AP,Brands PJ

    更新日期:1991-10-01 00:00:00

  • Reconstructing uniformly attenuated rotating slant-hole SPECT projection data using the DBH method.

    abstract::This work applies a previously developed analytical algorithm to the reconstruction problem in a rotating multi-segment slant-hole (RMSSH) SPECT system. The RMSSH collimator has greater detection efficiency than the parallel-hole collimator with comparable spatial resolution at the expense of limited common volume-of-...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/13/024

    authors: Huang Q,Xu J,Tsui BM,Gullberg GT

    更新日期:2009-07-07 00:00:00

  • An expression for backscatter factors for orthovoltage x-rays.

    abstract::Backscatter factors for orthovoltage x-ray beams are fitted with the expression BSF = 1 + ms/(s + n), where s is field size and m and n are adjustable parameters. The accuracy is better than 0.5%. Good results were also obtained for Cs-137 gamma rays at depth 0.12 cm and Co-60 gamma rays at depth 0.5 cm using the same...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/5/021

    authors: Xiao Y,Bjärngard B

    更新日期:1998-05-01 00:00:00

  • Response, thermal regulatory threshold and thermal breakdown threshold of restrained RF-exposed mice at 905 MHz.

    abstract::The objective of this study was the determination of the thermal regulatory and the thermal breakdown thresholds for in-tube restrained B6C3F1 and NMRI mice exposed to radiofrequency electromagnetic fields at 905 MHz. Different levels of the whole-body averaged specific absorption rate (SAR = 0, 2, 5, 7.2, 10, 12.6 an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/21/017

    authors: Ebert S,Eom SJ,Schuderer J,Apostel U,Tillmann T,Dasenbrock C,Kuster N

    更新日期:2005-11-07 00:00:00

  • Two-dimensional and quasi-three-dimensional dosimetry of hadron and photon beams with the Magic Cube and the Pixel Ionization Chamber.

    abstract::Two detectors for fast two-dimensional (2D) and quasi-three-dimensional (quasi-3D) verification of the dose delivered by radiotherapy beams have been developed at University and Istituto Nazionale di Fisica Nucleare (INFN) of Torino. The Magic Cube is a stack of strip-segmented ionization chambers interleaved with wat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/16/017

    authors: Cirio R,Garelli E,Schulte R,Amerio S,Boriano A,Bourhaleb F,Coutrakon G,Donetti M,Giordanengo S,Koss P,Madon E,Marchetto F,Nastasi U,Peroni C,Santuari D,Sardo A,Scielzo G,Stasi M,Trevisiol E

    更新日期:2004-08-21 00:00:00

  • Alanine dosimetry in strong magnetic fields: use as a transfer standard in MRI-guided radiotherapy.

    abstract::Reference dosimetry in the presence of a strong magnetic field is challenging. Ionisation chambers have shown to be strongly affected by magnetic fields. There is a need for robust and stable detectors in MRI-guided radiotherapy (MRIgRT). This study investigates the behaviour of the alanine dosimeter in magnetic field...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8148

    authors: Billas I,Bouchard H,Oelfke U,Shipley D,Gouldstone C,Duane S

    更新日期:2020-06-03 00:00:00

  • Systematic investigation of the signal properties of polycrystalline HgI2 detectors under mammographic, radiographic, fluoroscopic and radiotherapy irradiation conditions.

    abstract::The signal properties of polycrystalline mercuric iodide (HgI2) film detectors, under irradiation conditions relevant to mammographic, radiographic, fluoroscopic and radiotherapy x-ray imaging, are reported. Each film detector consists of an approximately 230 to approximately 460 microm thick layer of HgI2 (fabricated...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/12/012

    authors: Su Z,Antonuk LE,El-Mohri Y,Hu L,Du H,Sawant A,Li Y,Wang Y,Yamamoto J,Zhao Q

    更新日期:2005-06-21 00:00:00

  • Breast composition measurements using retrospective standard mammogram form (SMF).

    abstract::The standard mammogram form (SMF) representation of an x-ray mammogram is a standardized, quantitative representation of the breast from which the volume of non-fat tissue and breast density can be easily estimated, both of which are of significant interest in determining breast cancer risk. Previous theoretical analy...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/11/001

    authors: Highnam R,Pan X,Warren R,Jeffreys M,Davey Smith G,Brady M

    更新日期:2006-06-07 00:00:00

  • Self-adaptive ultrasonic beam amplifiers: application to transcostal shock wave therapy.

    abstract::Ultrasound shock wave therapy is increasingly used for non-invasive surgery. It requires the focusing of very high pressure amplitude in precisely controlled focal spots. In transcostal therapy of the heart or the liver, the high impedance mismatch between the bones and surrounding tissues gives rise to strong aberrat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad9b5

    authors: Robin J,Simon A,Arnal B,Tanter M,Pernot M

    更新日期:2018-09-06 00:00:00

  • Phase contrast image guidance for synchrotron microbeam radiotherapy.

    abstract::Recent image guidance developments for preclinical synchrotron microbeam radiotherapy represent a necessary step for future clinical translation of the technique. Image quality can be further improved using x-ray phase contrast, which is readily available at synchrotron facilities. We here describe a methodology for p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/16/5942

    authors: Pelliccia D,Crosbie JC,Larkin KG

    更新日期:2016-08-21 00:00:00

  • Monitoring of airborne contamination during the handling of technetium-99m and radioiodine.

    abstract::Measurements have been made using an air sampler to measure airborne radioactivity produced during the routine handling of large activities of technetium-99m, iodine-125 and iodine-131. The results indicate that 99Tcm can be safely handled in environments without direct exhaust of the ventilated air but that 125I and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/6/005

    authors: Eadie AS,Horton PW,Hilditch TE

    更新日期:1980-11-01 00:00:00

  • Automatic bladder segmentation on CBCT for multiple plan ART of bladder cancer using a patient-specific bladder model.

    abstract::In multiple plan adaptive radiotherapy (ART) strategies of bladder cancer, a library of plans corresponding to different bladder volumes is created based on images acquired in early treatment sessions. Subsequently, the plan for the smallest PTV safely covering the bladder on cone-beam CT (CBCT) is selected as the pla...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/12/3945

    authors: Chai X,van Herk M,Betgen A,Hulshof M,Bel A

    更新日期:2012-06-21 00:00:00

  • Effect of microscopic modeling of skin in electrical and thermal analysis of transcranial direct current stimulation.

    abstract::Transcranial direct current stimulation (tDCS) is a neuromodulation scheme where a small current is delivered to the brain via two electrodes attached to the scalp. The electrode design is an important topic, not only as regards efficacy, but also from a safety perspective, as tDCS may be related to skin lesions that ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/61/24/8825

    authors: Gomez-Tames J,Sugiyama Y,Laakso I,Tanaka S,Koyama S,Sadato N,Hirata A

    更新日期:2016-12-21 00:00:00

  • A novel technique for measuring the low-dose envelope of pencil-beam scanning spot profiles.

    abstract::To investigate the profile measurement capabilities of an IBA-Dosimetry scintillation detector and to assess its feasibility for determining the low-intensity tails of pencil-beam scanning spots, the responses of the scintillation detector and Gafchromic EBT2 film to a 115 MeV proton spot were measured in-air at the i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/12/N171

    authors: Lin L,Ainsley CG,Mertens T,De Wilde O,Talla PT,McDonough JE

    更新日期:2013-06-21 00:00:00

  • The effect of energy and source location on gamma camera intrinsic and extrinsic spatial resolution: an experimental and Monte Carlo study.

    abstract::Quantification of nuclear medicine image data is a prerequisite for personalized absorbed dose calculations and quantitative biodistribution studies. The spatial response of a detector is a governing factor affecting the accuracy of image quantification, and the aim of this work was to model this impact. To simulate s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/6/013

    authors: Holstensson M,Partridge M,Buckley SE,Flux GD

    更新日期:2010-03-21 00:00:00

  • Controlled E-field gradient coils for MRI.

    abstract::Peripheral neural stimulation is a major problem in current gradient coil designs. Induced current problems in patients relate directly to gradient strength and modulation frequency. Present designs of gradient coil tend to limit ultra-high-speed imaging methods such as echo-planar imaging (EPI) and echo-volumar imagi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/7/001

    authors: Mansfield P,Haywood B

    更新日期:2008-04-07 00:00:00

  • A depth-encoding PET detector for high resolution PET using 1 mm SiPMs.

    abstract::A dual-ended readout PET detector based on two Hamamatsu 16 × 16 arrays of 1 × 1 mm2 SiPMs coupled to both ends of a 25 × 25 array of 0.69 × 0.69 × 20 mm3 polished LYSOs was evaluated in terms of flood histogram, energy resolution, timing resolution, and DOI resolution. The SiPM arrays have a pitch size of 1.2 mm. Eac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9fc9

    authors: Du J,Bai X,Cherry SR

    更新日期:2020-08-19 00:00:00

  • An estimation of noise levels in HMPAO RCBF SPECT images using simulation and phantom data; comparison with results obtained from repeated normal controls.

    abstract::The purpose of this work was to determine noise levels in HMPAO RCBF SPECT images. Eight simulated images of a uniform sphere of activity were made at each of three different count levels. Three images of the Amersham brain phantom were obtained at each of three count levels, roughly corresponding to the simulation le...

    journal_title:Physics in medicine and biology

    pub_type: 临床试验,杂志文章

    doi:10.1088/0031-9155/39/5/006

    authors: Houston AS,Kemp PM,Griffiths PT,MacLeod MA

    更新日期:1994-05-01 00:00:00

  • Sub-100 ps coincidence time resolution for positron emission tomography with LSO:Ce codoped with Ca.

    abstract::The coincidence time resolution (CTR) becomes a key parameter of 511 keV gamma detection in time of flight positron emission tomography (TOF-PET). This is because additional information obtained through timing leads to a better noise suppression and therefore a better signal to noise ratio in the reconstructed image. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/12/4635

    authors: Nemallapudi MV,Gundacker S,Lecoq P,Auffray E,Ferri A,Gola A,Piemonte C

    更新日期:2015-06-21 00:00:00

  • Neutron scattering cross sections and partial kerma values for oxygen, nitrogen and calcium at 18 less than En less than 60 MeV.

    abstract::Recent measurements of differential elastic and inelastic neutron scattering from oxygen, nitrogen and calcium at 18 less than En less than 26 MeV are presented and analysed in terms of the optical model. These data, together with earlier measurements of scattering and total cross sections, are used to construct model...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/33/3/001

    authors: Islam MS,Finlay RW,Petler JS,Rapaport J,Alarcon R,Wierzbicki J

    更新日期:1988-03-01 00:00:00

  • A double-tuned (1)H/(23)Na dual resonator system for tissue sodium concentration measurements in the rat brain via Na-MRI.

    abstract::A method for quantifying the tissue sodium concentration (TSC) in the rat brain from ²³Na-MR images was developed. TSC is known to change in a variety of common human diseases and holds considerable potential to contribute to their study; however, its accurate measurement in small laboratory animals has been hindered ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/24/019

    authors: Wetterling F,Tabbert M,Junge S,Gallagher L,Macrae IM,Fagan AJ

    更新日期:2010-12-21 00:00:00

  • Dielectric characteristics of packed human erythrocytes with haemoglobins F, AA, AS and SS.

    abstract::The radiofrequency dielectric behaviour of packed human erythrocytes has been investigated in normal haemoglobins F and AA and also abnormal haemoglobins homozygous SS and heterozygous AS. Dielectric measurements were made in tightly packed blood cells at an average room temperature of 26.5 +/- 0.5 degrees C in the fr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/28/4/002

    authors: Laogun AA,Ajayi NO,Okafor LO,Osamo NO

    更新日期:1983-04-01 00:00:00

  • High resolution bone mineral densitometry with a gamma camera.

    abstract::A technique is described by which the regional distribution of bone mineral can be determined in bone samples from small animals. The technique employs an Anger camera interfaced to a medical computer. High resolution (less than 1 mm) imaging is possible by producing magnified images of the bone samples. Regional dens...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/1/003

    authors: LeBlanc A,Evans H,Jhingran S,Johnson P

    更新日期:1984-01-01 00:00:00

  • Accurate helical cone-beam CT reconstruction with redundant data.

    abstract::We present a new image reconstruction algorithm for helical cone-beam computed tomography (CT). This algorithm is designed for data collected at or near maximum pitch, and provides a theoretically exact and stable reconstruction while beneficially using all measured data. The main operations involved are a differentia...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/15/001

    authors: Schöndube H,Stierstorfer K,Noo F

    更新日期:2009-08-07 00:00:00

  • Optimization of MAGIC gel formulation for three-dimensional radiation therapy dosimetry.

    abstract::Polymer gel dosimetry aims to provide three-dimensional images of radiation therapy dose distributions in irradiated aqueous gels. The first gels required manufacture in an oxygen-free environment, but later the MAGIC formulation was introduced, which could be made in normal atmospheric conditions. Here we report our ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/10/N03

    authors: Luci JJ,Whitney HM,Gore JC

    更新日期:2007-05-21 00:00:00

  • On the use of an analytic source model for dose calculations in precision image-guided small animal radiotherapy.

    abstract::Precision image-guided small animal radiotherapy is rapidly advancing through the use of dedicated micro-irradiation devices. However, precise modeling of these devices in model-based dose-calculation algorithms such as Monte Carlo (MC) simulations continue to present challenges due to a combination of very small beam...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/10/3377

    authors: Granton PV,Verhaegen F

    更新日期:2013-05-21 00:00:00

  • A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging.

    abstract::A dedicated small-animal x-ray micro computed tomography (micro-CT) system has been developed to screen laboratory small animals such as mice and rats. The micro-CT system consists of an indirect-detection flat-panel x-ray detector with a field-of-view of 120 x 120 mm2, a microfocus x-ray source, a rotational subject ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/24/014

    authors: Lee SC,Kim HK,Chun IK,Cho MH,Lee SY,Cho MH

    更新日期:2003-12-21 00:00:00