The quality of ionising radiations emitted by radionuclides incorporated into mammalian cells.

Abstract:

:Radionuclides which decay by electron capture accompanied by Auger electron cascades, or by beta emission are thought to be excessively damaging when incorporated into the molecular structure of mammalian cell nuclei and thereby pose a radiation hazard which is not assessable by conventional dosimetry. Survival data, from the literature, for 125I, 77Br, 3H and 131I have been re-analysed to extract cross sections for inactivation, by the slowing down charged particle fluence, as these are absolute specifications of the radiation quality. When comparison is made with results similarly expressed for external irradiation with heavy particle and photon beams, the qualities of the low-energy emitters 125I, 77Br and 3H are found to approach those for heavy particles. An explanation for the damage mechanism is sought in a recently developed model for radiation action. The results are consistent with the interpretation that electron damage is caused predominantly at the end of the tracks, and the actual incorporation simply ensures that the slowing down fluence of low-energy tracks interacts preferentially in the vicinity of the radiosensitive sites. The absolute biological effectiveness of these radiations can be expressed quantitatively in terms of the model parameters.

journal_name

Phys Med Biol

authors

Younis AR,Watt DE

doi

10.1088/0031-9155/34/7/003

subject

Has Abstract

pub_date

1989-07-01 00:00:00

pages

821-34

issue

7

eissn

0031-9155

issn

1361-6560

journal_volume

34

pub_type

杂志文章
  • Task-based measures of image quality and their relation to radiation dose and patient risk.

    abstract::The theory of task-based assessment of image quality is reviewed in the context of imaging with ionizing radiation, and objective figures of merit (FOMs) for image quality are summarized. The variation of the FOMs with the task, the observer and especially with the mean number of photons recorded in the image is discu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/60/2/R1

    authors: Barrett HH,Myers KJ,Hoeschen C,Kupinski MA,Little MP

    更新日期:2015-01-21 00:00:00

  • A unified analysis of FBP-based algorithms in helical cone-beam and circular cone- and fan-beam scans.

    abstract::A circular scanning trajectory is and will likely remain a popular choice of trajectory in computed tomography (CT) imaging because it is easy to implement and control. Filtered-backprojection (FBP)-based algorithms have been developed previously for approximate and exact reconstruction of the entire image or a region...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/18/011

    authors: Pan X,Xia D,Zou Y,Yu L

    更新日期:2004-09-21 00:00:00

  • Physical characterization and performance comparison of active- and passive-pixel CMOS detectors for mammography.

    abstract::We investigated the physical characteristics of two complementary metal oxide semiconductor (CMOS) mammography detectors. The detectors featured 14-bit image acquisition, 50 microm detector element (del) size and an active area of 5 cm x 5 cm. One detector was a passive-pixel sensor (PPS) with signal amplification per...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/6/022

    authors: Elbakri IA,McIntosh BJ,Rickey DW

    更新日期:2009-03-21 00:00:00

  • Proof-of-concept delivery of intensity modulated arc therapy on the Elekta Unity 1.5 T MR-linac.

    abstract::In this work we present the first delivery of intensity modulated arc therapy on the Elekta Unity 1.5 T MR-linac. The machine's current IMRT based control system was modified suitably to enable dynamic delivery of radiation, for the purpose of exploring MRI-guided radiation therapy adaptation modes in a research setti...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abd66d

    authors: Kontaxis C,Woodhead PL,Bol GH,Lagendijk JJW,Raaymakers BW

    更新日期:2020-12-23 00:00:00

  • Single and multiple cross sections for ionizing processes of biological molecules by protons and alpha-particle impact: a classical Monte Carlo approach.

    abstract::A classical trajectory model has been used to predict total cross sections of single and double ionizing processes (including capture processes) for several ion-biological molecule collisional systems in the intermediate and high energy range. In this work, the systems studied are water, adenine or cytosine targets io...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/4/N03

    authors: Abbas I,Champion C,Zarour B,Lasri B,Hanssen J

    更新日期:2008-02-21 00:00:00

  • The fast Padé transform in magnetic resonance spectroscopy for potential improvements in early cancer diagnostics.

    abstract::The convergence rates of the fast Padé transform (FPT) and the fast Fourier transform (FFT) are compared. These two estimators are used to process a time-signal encoded at 4 T by means of one-dimensional magnetic resonance spectroscopy (MRS) for healthy human brain. It is found systematically that at any level of trun...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/18/010

    authors: Belkić D,Belkić K

    更新日期:2005-09-21 00:00:00

  • Quantitative analysis of bony birth canal for periacetabular osteotomy patient by template fitting.

    abstract::Periacetabular osteotomy (PAO) is a joint preservation procedure for developmental dysplasia of the hip. Such a procedure requires osteotomy of the medial wall of the acetabulum, which may cause the narrow of the bony birth canal and increase the risk of complications during the childbirth process in the future. Using...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abcb22

    authors: Shao L,Li H,Liu X,Wang Y,Shi L,Ai D,Fan J,Song H,Zhang H,Yang J

    更新日期:2021-01-22 00:00:00

  • Exploration and application of phenomenological RBE models for proton therapy.

    abstract::The relative biological effectiveness (RBE) of protons varies with multiple physical and biological factors. Phenomenological RBE models have been developed to include such factors in the estimation of a variable RBE, in contrast to the clinically applied constant RBE of 1.1. In this study, eleven published phenomenol...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad9db

    authors: Rørvik E,Fjæra LF,Dahle TJ,Dale JE,Engeseth GM,Stokkevåg CH,Thörnqvist S,Ytre-Hauge KS

    更新日期:2018-09-13 00:00:00

  • An investigation and explanation of the fall-off of x-ray tube current during an exposure.

    abstract::It was observed that the radiation output of x-ray tubes falls off exponentially during an exposure with a time constant of about 120 ms. The equilibrium value is approximately 15% lower than that at the beginning of the exposure. The clinically noticeable consequences are discrepancies in x-ray generator calibration,...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/2/004

    authors: Brezovich IA,Barnes GT

    更新日期:1980-03-01 00:00:00

  • Scheduling cisplatin and radiotherapy in the treatment of squamous cell carcinomas of the head and neck: a modelling approach.

    abstract::The aim of the present work was to implement the kinetics of cisplatin into a previously developed tumour growth model and to simulate the combined cisplatin-radiotherapy treatment with the emphasis on time sequencing and scheduling of drug and radiation. An investigation into whether the effect of cisplatin-radiation...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/15/002

    authors: Marcu L,Bezak E,Olver I

    更新日期:2006-08-07 00:00:00

  • Beveled fiber-optic probe couples a ball lens for improving depth-resolved fluorescence measurements of layered tissue: Monte Carlo simulations.

    abstract::In this study, we evaluate the feasibility of designing a beveled fiber-optic probe coupled with a ball lens for improving depth-resolved fluorescence measurements of epithelial tissue using Monte Carlo (MC) simulations. The results show that by using the probe configuration with a beveled tip collection fiber and a f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/4/008

    authors: Jaillon F,Zheng W,Huang Z

    更新日期:2008-02-21 00:00:00

  • The energy response of a T.P.A. Mk-II ionization chamber using GEANT4 Monte Carlo simulation.

    abstract::The low energy model of the GEANT4 Monte Carlo toolkit was used to simulate the energy response of a T.P.A. Mk-II ionization chamber under a variety of different conditions. The sample position resulting in the maximum response along the axial direction of the chamber was obtained. The parameters of the simulation wer...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/13/012

    authors: Seneviratne MD,Reinhard MI,Baldock C

    更新日期:2007-07-07 00:00:00

  • Determination of some parameters for pion radiobiology studies.

    abstract::An experimental investigation of the central axis depth-dose and stopping rate distribution of the SIN biomedical pion beam is reported. The pion stopping rate in a thin disc of tissue-equivalent plastic was determined using a counter telescope. The dose rate at the position of this dic 'target' was measured using a s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/22/3/007

    authors: Nordell B,Baarli J,Sullivan AH,Zielczynski M

    更新日期:1977-05-01 00:00:00

  • Characterization of a single LSO crystal layer high resolution research tomograph.

    abstract::The purpose of this study was to determine the performance of a single lutetium oxy-orthosilicate (LSO) crystal layer High Resolution Research Tomograph (HRRT) positron emission tomography (PET) scanner. The HRRT is a high resolution PET scanner designed for human brain and small animal imaging. The scanner consists o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/4/302

    authors: Boellaard R,Buijs F,de Jong HW,Lenox M,Gremillion T,Lammertsma AA

    更新日期:2003-02-21 00:00:00

  • Respiratory liver motion estimation and its effect on scanned proton beam therapy.

    abstract::Proton therapy with active scanning beam delivery has significant advantages compared to conventional radiotherapy. However, so far only static targets have been treated in this way, since moving targets potentially lead to interplay effects. For 4D treatment planning, information on the target motion is needed to cal...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/7/1779

    authors: Zhang Y,Boye D,Tanner C,Lomax AJ,Knopf A

    更新日期:2012-04-07 00:00:00

  • Counting losses in multidetector radiation counters.

    abstract::We examined the reasons for the reduction in response of a multidetector radiation counting system when operated at high count-rates and established a convenient method of correction which is accurate to within +/- 1% up to 0-6 X 10(5) counts per second. In its application the method uses the observed count-rates from...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/21/1/009

    authors: Oxby CB,Oldroyd B,Appleby DB

    更新日期:1976-01-01 00:00:00

  • Super-resolution reconstruction of 4D-CT lung data via patch-based low-rank matrix reconstruction.

    abstract::Lung 4D computed tomography (4D-CT), which is a time-resolved CT data acquisition, performs an important role in explicitly including respiratory motion in treatment planning and delivery. However, the radiation dose is usually reduced at the expense of inter-slice spatial resolution to minimize radiation-related heal...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa8a48

    authors: Fang S,Wang H,Liu Y,Zhang M,Yang W,Feng Q,Chen W,Zhang Y

    更新日期:2017-10-03 00:00:00

  • Phase contrast image guidance for synchrotron microbeam radiotherapy.

    abstract::Recent image guidance developments for preclinical synchrotron microbeam radiotherapy represent a necessary step for future clinical translation of the technique. Image quality can be further improved using x-ray phase contrast, which is readily available at synchrotron facilities. We here describe a methodology for p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/16/5942

    authors: Pelliccia D,Crosbie JC,Larkin KG

    更新日期:2016-08-21 00:00:00

  • Single spectrum three-material decomposition with grating-based x-ray phase-contrast CT.

    abstract::Grating-based x-ray phase-contrast imaging provides three simultaneous image channels originating from a single image acquisition. While the phase signal provides direct access to the electron density in tomography, there is additional information on sub-resolutional structural information which is called dark-field s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9704

    authors: Braig EM,Pfeiffer D,Willner M,Sellerer T,Taphorn K,Petrich C,Scholz J,Petzold L,Birnbacher L,Dierolf M,Pfeiffer F,Herzen J

    更新日期:2020-09-18 00:00:00

  • Prediction of lung tumor motion using nonlinear autoregressive model with exogenous input.

    abstract::The present note addresses the development of a lung tumor position predictor to be used in dynamic tumor tracking radiotherapy, abbreviated as DTT-RT. As there exists 50-500 ms positioning lag in the control of the multi-leaf collimator (MLC) of commercial medical linear accelerators, prediction of future lung tumor ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab49ea

    authors: Jiang K,Fujii F,Shiinoki T

    更新日期:2019-10-31 00:00:00

  • The physics of red cell sedimentation.

    abstract::Blood was withdrawn from the ante-cubital vein of five normal volunteers and the erythrocytes were washed and resuspended in isotonic saline. The rate of descent of the erythrocyte-saline boundary was measured every hour for a period of at least 4 h for different suspended cell concentrations. The velocity of this bou...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/2/002

    authors: Smallwood RH,Tindale WB,Trowbridge EA

    更新日期:1985-02-01 00:00:00

  • Correlation between human and model observer performance for discrimination task in CT.

    abstract::Although physical metrics can objectively characterize computed tomography (CT) image quality, quantitative approaches to predict human observer performance are more accurate and clinically relevant. This study compared a modified channelized Hotelling model observer (CHO) with human observers in a shape discriminatio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/13/3389

    authors: Zhang Y,Leng S,Yu L,Carter RE,McCollough CH

    更新日期:2014-07-07 00:00:00

  • Measurement of patient entrance surface dose rates for fluoroscopic x-ray units.

    abstract::Measurements of patient entrance surface dose rate provide valuable data for interpreting results from dose-area product studies on fluoroscopic x-ray equipment. Methods for measurement of entrance surface dose rate with backscatter and incident dose rate without backscatter have been investigated. Entrance surface do...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/5/008

    authors: Martin CJ

    更新日期:1995-05-01 00:00:00

  • Analysis on reversible/irreversible electroporation region in lung adenocarcinoma cell modelin vitrowith electric pulses delivered by needle electrodes.

    abstract::Irreversible electroporation (IRE) is a minimally invasive tumor therapy using pulsed electric field with high intensity while the important tissues such as blood vessel, bile duct, and nerve are preserved. In addition to ablation area, reversible electroporation (RE) region is also generated using needle electrodes f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abc12e

    authors: Lv Y,Tang X,Peng W,Cheng X,Chen S,Yao C

    更新日期:2020-10-14 00:00:00

  • Evaluation of a novel triple-channel radiochromic film analysis procedure using EBT2.

    abstract::A novel approach to read out radiochromic film was introduced recently by the manufacturer of GafChromic film. In this study, the performance of this triple-channel film dosimetry method was compared against the conventional single-red-channel film dosimetry procedure, with and without inclusion of a pre-irradiation (...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/13/4353

    authors: van Hoof SJ,Granton PV,Landry G,Podesta M,Verhaegen F

    更新日期:2012-07-07 00:00:00

  • Tumour oxygen dynamics measured simultaneously by near-infrared spectroscopy and 19F magnetic resonance imaging in rats.

    abstract::Simultaneous near-infrared spectroscopy (NIRS) and magnetic resonance imaging (MRI) were used to investigate the correlation between tumour vascular oxygenation and tissue oxygen tension dynamics in rat breast 13762NF tumours with respect to hyperoxic gas breathing. NIRS directly detected global variations in the oxyg...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/1/004

    authors: Xia M,Kodibagkar V,Liu H,Mason RP

    更新日期:2006-01-07 00:00:00

  • Head scatter modelling for irregular field shaping and beam intensity modulation.

    abstract::Scattered radiation from within the treatment head can contribute significant dose to all parts of a radiotherapy treatment field. A multileaf collimator may be used to create an arbitrarily shaped field, and may also be used, under dynamic control, to modulate the beam intensity over the field. This method of intensi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/9/006

    authors: Hounsell AR,Wilkinson JM

    更新日期:1997-09-01 00:00:00

  • Electron depth-dose dependence on energy spectral quality.

    abstract::Electron depth-dose curves and spectra have been measured from an experimental accelerator on which both energy and spectral shape could be varied independently. The measurements were made at nominal energies of 6 and 12 MeV, with the energy spread (FWHM) varied from 1.7% to over 10% of average energy. Changes in dept...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/28/12/005

    authors: Johnsen SW,LaRiviere PD,Tanabe E

    更新日期:1983-12-01 00:00:00

  • X-ray beam filtration, dosimetry phantom size and CT patient dose conversion factors.

    abstract::We examine how the choice of CT x-ray beam filtration and phantom size influences patient dose (D) to computed tomography dose index (CTDI) conversion factors (i.e. D/CTDI). The ratio of head to body phantom CTDI(w) for a defined scan technique is alpha, and the ratio of organ dose when the body filter is changed to t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/2/014

    authors: Huda W,Sterzik A,Tipnis S

    更新日期:2010-01-21 00:00:00

  • Markerless positional verification using template matching and triangulation of kV images acquired during irradiation for lung tumors treated in breath-hold.

    abstract::Lung tumors treated in breath-hold are subject to inter- and intra-breath-hold variations, which makes tumor position monitoring during each breath-hold important. A markerless technique is desirable, but limited tumor visibility on kV images makes this challenging. We evaluated if template matching  +  triangulation ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aac1a9

    authors: Hazelaar C,Dahele M,Mostafavi H,van der Weide L,Slotman B,Verbakel W

    更新日期:2018-05-29 00:00:00