Factors affecting in vivo measurement precision and accuracy of 109Cd K x-ray fluorescence measurements.

Abstract:

:109Cd K x-ray fluorescence (XRF) measurement systems from two research centres were used to measure tibia lead content in a population (n = 530) of young adults. The group mean bone lead contents (+/-SEM) determined by McMaster University (n = 214) and the University of Maryland (n = 316) were 2.80 +/- 0.51 and 2.33 +/- 0.50 microg Pb/(g bone mineral) respectively. The mean difference of 0.47 +/- 0.71 microg Pb/(g bone mineral) was not significant. There was no evidence of a systematic difference between measurements from the two systems. Measurement uncertainties for the young adults were poorer overall than uncertainties for a population of occupationally exposed men. This was because obese subjects and women were included in the study. Regressions of precision against body mass index (BMI, defined as weight/height2) determined that uncertainties increased with BMI and were poorer for women than men. Measurement uncertainties (1sigma) were >8 microg Pb/(g bone mineral) for women with a BMI > 0.004 kg cm(-2). Poor-precision data affected population estimates of bone lead content; an inverse correlation was found between precision and bone lead content. A small number (0.4%) of individual measurements with poor uncertainties were inaccurate to within the precision. It is suggested that obese subjects, whose BMI > 0.004 kg cm(-2), should be excluded from 109Cd K XRF studies, as the measurement provides limited information and may be inaccurate.

journal_name

Phys Med Biol

authors

McNeill FE,Stokes L,Chettle DR,Kaye WE

doi

10.1088/0031-9155/44/9/313

subject

Has Abstract

pub_date

1999-09-01 00:00:00

pages

2263-73

issue

9

eissn

0031-9155

issn

1361-6560

journal_volume

44

pub_type

杂志文章
  • A dedicated phantom design for positron emission mammography performance evaluation.

    abstract::A standard protocol for performance evaluation of positron emission mammography (PEM) systems has not yet been established. In this work we propose a methodology based on the design of specific phantoms for this imaging modality with component dimensions in accordance with typical breast lesion sizes together with the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aba7d1

    authors: Torres-Urzúa LF,Alva-Sanchez H,Martinez-Davalos A,García-Pérez FO,Peruyero-Rivas RM,Rodriguez-Villafuerte M

    更新日期:2020-07-21 00:00:00

  • Applying a variable relative biological effectiveness (RBE) might affect the analysis of clinical trials comparing photon and proton therapy for prostate cancer.

    abstract::The purpose of this study was the evaluation of the impact of a variable relative biological effectiveness (RBE) compared to a constant RBE value of 1.1 in proton therapy prostate trials due to uncertainties in α/β ratio. Twenty patients receiving passive scattered proton therapy (PSPT) and fifteen patients receiving ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2144

    authors: Marteinsdottir M,Paganetti H

    更新日期:2019-06-05 00:00:00

  • Relative Patlak plot for dynamic PET parametric imaging without the need for early-time input function.

    abstract::The Patlak graphical method is widely used in parametric imaging for modeling irreversible radiotracer kinetics in dynamic PET. The net influx rate of radiotracer can be determined from the slope of the Patlak plot. The implementation of the standard Patlak method requires the knowledge of full-time input function fro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad444

    authors: Zuo Y,Qi J,Wang G

    更新日期:2018-08-10 00:00:00

  • Comment on 'egs_brachy: a versatile and fast Monte Carlo code for brachytherapy'.

    abstract::In a recent paper (Chamberland et al 2016 Phys. Med. Biol. 61 8214) develop a new Monte Carlo code called egs_brachy for brachytherapy treatments. It is based on EGSnrc, and written in the C++ programming language. In order to benchmark the egs_brachy code, the authors use it in various test case scenarios in which co...

    journal_title:Physics in medicine and biology

    pub_type: 评论,杂志文章,信件

    doi:10.1088/1361-6560/aa9ea1

    authors: Yegin G

    更新日期:2018-02-02 00:00:00

  • Fuzzy clustering-based segmented attenuation correction in whole-body PET imaging.

    abstract::Segmented attenuation correction is now a widely accepted technique to reduce noise propagation from transmission scanning in positron emission tomography (PET). In this paper, we present a new method for segmenting transmission images in whole-body scanning. This reduces the noise in the correction maps while still c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/7/310

    authors: Zaidi H,Diaz-Gomez M,Boudraa A,Slosman DO

    更新日期:2002-04-07 00:00:00

  • Optimizing the planning of intensity-modulated radiotherapy.

    abstract::A method of computing optimized intensity-modulated beam profiles has been further developed and used to generate highly conformal radiotherapy dose distributions. The features of these distributions are shown to be strongly dependent on the tuning built into the algorithm. The optimization aims to achieve a specified...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/12/007

    authors: Webb S

    更新日期:1994-12-01 00:00:00

  • Investigation of ultrasonic properties of PAG and MAGIC polymer gel dosimeters.

    abstract::Ultrasonic speed of propagation and attenuation were investigated as a function of absorbed radiation dose in PAG and MAGIC polymer gel dosimeters. Both PAG and MAGIC gel dosimeters displayed a dependence of ultrasonic parameters on absorbed dose with attenuation displaying significant changes in the dose range invest...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/24/307

    authors: Mather ML,De Deene Y,Whittaker AK,Simon GP,Rutgers R,Baldock C

    更新日期:2002-12-21 00:00:00

  • Developing a new case based computer-aided detection scheme and an adaptive cueing method to improve performance in detecting mammographic lesions.

    abstract::The purpose of this study is to evaluate a new method to improve performance of computer-aided detection (CAD) schemes of screening mammograms with two approaches. In the first approach, we developed a new case based CAD scheme using a set of optimally selected global mammographic density, texture, spiculation, and st...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5081

    authors: Tan M,Aghaei F,Wang Y,Zheng B

    更新日期:2017-01-21 00:00:00

  • Investigation of saddle trajectories for cardiac CT imaging in cone-beam geometry.

    abstract::This paper investigates cone-beam tomography for a wide class of x-ray source trajectories called saddles. In particular, a mathematical analysis of the number of intersections between a saddle and an arbitrary plane is given. This analysis demonstrates that axially truncated cone-beam projections acquired along a sad...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/11/014

    authors: Pack JD,Noo F,Kudo H

    更新日期:2004-06-07 00:00:00

  • The sliding slit test for dynamic IMRT: a useful tool for adjustment of MLC related parameters.

    abstract::For treatments with dynamic intensity modulated radiotherapy (IMRT), the adjustment of multileaf collimator (MLC) parameters affecting both the optimization algorithm and dose distributions is crucial. The main parameters characterizing the MLC are the transmission (T) and the dosimetric leaf separation (DLS). The aim...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/4/001

    authors: Chauvet I,Petitfils A,Lehobey C,Kristner JY,Brunet Y,Lembrez R,Gaboriaud G,Mazal A,Zefkili S,Rosenwald JC

    更新日期:2005-02-21 00:00:00

  • Automatic classification of dental artifact status for efficient image veracity checks: effects of image resolution and convolutional neural network depth.

    abstract::Enabling automated pipelines, image analysis and big data methodology in cancer clinics requires thorough understanding of the data. Automated quality assurance steps could improve the efficiency and robustness of these methods by verifying possible data biases. In particular, in head and neck (H&N) computed-tomograph...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab5427

    authors: Welch ML,McIntosh C,Purdie TG,Wee L,Traverso A,Dekker A,Haibe-Kains B,Jaffray DA

    更新日期:2020-01-10 00:00:00

  • Self-adaptive ultrasonic beam amplifiers: application to transcostal shock wave therapy.

    abstract::Ultrasound shock wave therapy is increasingly used for non-invasive surgery. It requires the focusing of very high pressure amplitude in precisely controlled focal spots. In transcostal therapy of the heart or the liver, the high impedance mismatch between the bones and surrounding tissues gives rise to strong aberrat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad9b5

    authors: Robin J,Simon A,Arnal B,Tanter M,Pernot M

    更新日期:2018-09-06 00:00:00

  • Range and dose verification in proton therapy using proton-induced positron emitters and recurrent neural networks (RNNs).

    abstract::Online proton range/dose verification based on measurements of proton-induced positron emitters is a promising strategy for quality assurance in proton therapy. Because of the nonlinear correlation between the dose distribution and the activity distribution of positron emitters, we aim to establish their relationship ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab3564

    authors: Liu C,Li Z,Hu W,Xing L,Peng H

    更新日期:2019-09-04 00:00:00

  • Monte Carlo verification of polymer gel dosimetry applied to radionuclide therapy: a phantom study.

    abstract::This study evaluates the dosimetric performance of the polymer gel dosimeter 'Methacrylic and Ascorbic acid in Gelatin, initiated by Copper' and its suitability for quality assurance and analysis of I-131-targeted radionuclide therapy dosimetry. Four batches of gel were manufactured in-house and sets of calibration vi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/22/017

    authors: Gear JI,Charles-Edwards E,Partridge M,Flux GD

    更新日期:2011-11-21 00:00:00

  • Influence of initial electron beam characteristics on monte carlo calculated absorbed dose distributions for linear accelerator electron beams.

    abstract::The least known parameters in a Monte Carlo simulation of a linear accelerator treatment head are often the properties of the initial electron beam directed onto the exit vacuum window. Several initial beams with different spatial fluence distributions, angular divergences and energy spectra have been transported thro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/22/308

    authors: Björk P,Knöös T,Nilsson P

    更新日期:2002-11-21 00:00:00

  • Kill painting of hypoxic tumors with multiple ion beams.

    abstract::We report on a novel method for simultaneous biological optimization of treatment plans for hypoxic tumors using multiple ion species. Our previously introduced kill painting approach, where the overall cell killing is optimized on biologically heterogeneous targets, was expanded with the capability of handling differ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aafe40

    authors: Sokol O,Krämer M,Hild S,Durante M,Scifoni E

    更新日期:2019-02-08 00:00:00

  • A revised monitor source method for practical deadtime count loss compensation in clinical planar and SPECT studies.

    abstract::The aim of the study is to verify the fundamental assumption in the monitor source method, i.e. uniform fractional count loss across the field of view (FOV), and to introduce a revised monitor source method for SPECT deadtime correction that minimally interferes with the clinical protocol. SPECT images of non-uniform ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/3/1199

    authors: Siman W,Silosky M,Kappadath SC

    更新日期:2015-02-07 00:00:00

  • Distributed three-dimensional simulation of B-mode ultrasound imaging using a first-order k-space method.

    abstract::Computational modeling is an important tool in ultrasound imaging research, but realistic three-dimensional (3D) simulations can exceed the capabilities of serial computers. This paper uses a 3D simulator based on a k-space method that incorporates relaxation absorption and nonreflecting boundary conditions. The simul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/17/007

    authors: Daoud MI,Lacefield JC

    更新日期:2009-09-07 00:00:00

  • Relative determination of W-values for alpha particles in tissue-equivalent and other gases.

    abstract::W (the average energy to form an ion pair) for 5.4 MeV 241Am alpha particles in a Rossi-type tissue-equivalent (TE) gas, argon and methane was determined to an accuracy better than 0.2% using a new automated data handling system. A vibrating reed electrometer and current digitiser were used to measure the current prod...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/24/2/005

    authors: Krieger GL,Baum JW,Varma MN,Beach JL

    更新日期:1979-03-01 00:00:00

  • The influence of metal artefacts on the range of ion beams.

    abstract::The influence of artefacts due to metal implants on the range of ion beams is investigated, using a geometrically well-defined head and pelvic phantom together with inserts from steel, titanium and tungsten. The ranges along various beam paths including artefacts were calculated from the TPS and compared to known calc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/3/007

    authors: Jäkel O,Reiss P

    更新日期:2007-02-07 00:00:00

  • Reply to comment on 'origins of the changing detector response in small megavoltage photon radiation fields'.

    abstract::Andreo and Benmakhlouf (2017 Phys. Med. Biol. 62 1518-32) have disputed a finding of Scott et al (2012 Phys. Med. Biol. 57 4461-76) that the variation with field-size of the response of small ion chambers and solid-state dosimeters in small megavoltage photon radiation fields can largely be attributed to density. Furt...

    journal_title:Physics in medicine and biology

    pub_type: 评论,杂志文章

    doi:10.1088/1361-6560/aae0e4

    authors: Fenwick JD,Georgiou G,Rowbottom CG,Underwood TSA,Kumar S

    更新日期:2018-10-03 00:00:00

  • Development and validation of RAYDOSE: a Geant4-based application for molecular radiotherapy.

    abstract::We developed and validated a Monte-Carlo-based application (RAYDOSE) to generate patient-specific 3D dose maps on the basis of pre-treatment imaging studies. A CT DICOM image is used to model patient geometry, while repeated PET scans are employed to assess radionuclide kinetics and distribution at the voxel level. In...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/8/2491

    authors: Marcatili S,Pettinato C,Daniels S,Lewis G,Edwards P,Fanti S,Spezi E

    更新日期:2013-04-21 00:00:00

  • Temperature simulations in tissue with a realistic computer generated vessel network.

    abstract::The practical use of a discrete vessel thermal model for hyperthermia treatment planning requires a number of choices with respect to the unknown part of the patient's vasculature. This work presents a study of the thermal effects of blood flow in a simple tissue geometry with a detailed artificial vessel network. The...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/4/317

    authors: Van Leeuwen GM,Kotte AN,Raaymakers BW,Lagendijk JJ

    更新日期:2000-04-01 00:00:00

  • Strategies to improve 3D whole-body PET image reconstruction.

    abstract::An algorithm is described for three-dimensional whole-body (3DWB) image reconstruction in positron emission tomography. For whole-body applications, improvements to the popular fixed-axial-acceptance-angle technique are achieved by combining axially adjacent projection data available with a long-axis data set. Time-co...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/8/013

    authors: Cutler PD,Xu M

    更新日期:1996-08-01 00:00:00

  • Aerosol particle impaction in the conducting airways.

    abstract::Modelling of inhaled particle deposition in the lungs potentially offers data relevant to assessing hazards from toxic inhaled particles, to studying mucus clearance or lung permeability by aerosol techniques, and to achieving better utilisation of drugs administered as aerosols. Analysis of published modelling studie...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/7/001

    authors: Agnew JE,Pavia D,Clarke SW

    更新日期:1984-07-01 00:00:00

  • Measurement of patient entrance surface dose rates for fluoroscopic x-ray units.

    abstract::Measurements of patient entrance surface dose rate provide valuable data for interpreting results from dose-area product studies on fluoroscopic x-ray equipment. Methods for measurement of entrance surface dose rate with backscatter and incident dose rate without backscatter have been investigated. Entrance surface do...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/5/008

    authors: Martin CJ

    更新日期:1995-05-01 00:00:00

  • A proposal concerning the absorbed dose conversion factor.

    abstract::New definitions of the absorbed dose conversion factors Clambda and CE are proposed. The absorbed dose in water is given by the product of absorbed dose conversion factor, exposure calibration factor, ionisation chamber reading, cap displacement correction factor and perturbation correction factor. At exposure calibra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/23/2/003

    authors: Shiragai A

    更新日期:1978-03-01 00:00:00

  • A framework for organ dose estimation in x-ray angiography and interventional radiology based on dose-related data in DICOM structured reports.

    abstract::Although interventional x-ray angiography (XA) procedures involve relatively high radiation doses that can lead to deterministic tissue reactions in addition to stochastic effects, convenient and accurate estimation of absorbed organ doses has traditionally been out of reach. This has mainly been due to the absence of...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/8/3063

    authors: Omar A,Bujila R,Fransson A,Andreo P,Poludniowski G

    更新日期:2016-04-21 00:00:00

  • Benchmarking GATE/Geant4 for 16O ion beam therapy.

    abstract::Oxygen ([Formula: see text]) ions are a potential alternative to carbon ions in ion beam therapy. Their enhanced linear energy transfer indicates a higher relative biological effectiveness and a reduced oxygen enhancement ratio. Due to the limited availability of [Formula: see text] ion beams, Monte Carlo (MC) transpo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa807e

    authors: Resch AF,Fuchs H,Georg D

    更新日期:2017-09-05 00:00:00

  • Gating characteristics of an Elekta radiotherapy treatment unit measured with three types of detector.

    abstract::The characteristics of an Elekta Precise treatment machine with a gating interface were investigated. Three detectors were used: a Farmer ionization chamber, a MatriXX ionization chamber array and an in-house, single pulse-measurement ionization chamber (IVC). Measurements were made of dosimetric accuracy, flatness an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/8/N02

    authors: Evans PM,Symonds-Tayler JR,Colgan R,Hugo GD,Letts N,Sandin C

    更新日期:2010-04-21 00:00:00