Reply to comment on 'origins of the changing detector response in small megavoltage photon radiation fields'.

Abstract:

:Andreo and Benmakhlouf (2017 Phys. Med. Biol. 62 1518-32) have disputed a finding of Scott et al (2012 Phys. Med. Biol. 57 4461-76) that the variation with field-size of the response of small ion chambers and solid-state dosimeters in small megavoltage photon radiation fields can largely be attributed to density. Further evidence for this finding was provided by Fenwick et al (2018 Phys. Med. Biol. 63 125003), but Andreo and Benmakhlouf (2018 Phys. Med. Biol. 63 125003) have now challenged the methodology used in that study. Specifically, Andreo and Benmakhlouf suggest that mass stopping-powers of fictitious materials used in Monte Carlo radiation transport calculations should be adjusted with material density according to the polarization effect, as if the materials were real and created by compressing other real materials. In this reply, we observe that fictitious materials are not real, and therefore their densities, mass stopping-powers and microscopic radiation interaction cross-sections can be freely and independently chosen to provide the clearest answers to the questions being studied. And we note that the key role played by density in small field detector response was further confirmed by our group back in 2013, using fictitious materials in which mass stopping-powers were adjusted with density, as preferred by Andreo and Benmakhlouf, as well as being held fixed, with very similar results being obtained in both circumstances (Underwood et al 2013a Med. Phys. 40 082102).

journal_name

Phys Med Biol

authors

Fenwick JD,Georgiou G,Rowbottom CG,Underwood TSA,Kumar S

doi

10.1088/1361-6560/aae0e4

subject

Has Abstract

pub_date

2018-10-03 00:00:00

pages

198002

issue

19

eissn

0031-9155

issn

1361-6560

journal_volume

63

pub_type

评论,杂志文章
  • Direct 4D reconstruction of parametric images incorporating anato-functional joint entropy.

    abstract::We developed an anatomy-guided 4D closed-form algorithm to directly reconstruct parametric images from projection data for (nearly) irreversible tracers. Conventional methods consist of individually reconstructing 2D/3D PET data, followed by graphical analysis on the sequence of reconstructed image frames. The propose...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/15/005

    authors: Tang J,Kuwabara H,Wong DF,Rahmim A

    更新日期:2010-08-07 00:00:00

  • The influence of a clear layer on near-infrared spectrophotometry measurements using a liquid neonatal head phantom.

    abstract::It is difficult to test near-infrared spectrophotometry instruments in vivo. Therefore we constructed a liquid phantom which mimics the neonatal head. It consists of a spherical 3.5 mm thick layer of silicone rubber simulating skin and bone and a 0.5 mm thick clear layer of polypropylene imitating cerebrospinal fluid....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/7/313

    authors: Wolf M,Keel M,Dietz V,von Siebenthal K,Bucher HU,Baenziger O

    更新日期:1999-07-01 00:00:00

  • Automatic system for measuring dose-area product (DAP) in ROI fluoroscopy.

    abstract::A computerized system for monitoring dose-area product (DAP) has been developed for region of interest (ROI) fluoroscopy in which patient exposure is reduced using an x-ray attenuating filter with an aperture. The system includes an IBM compatible computer which is connected through an IEEE-488 interface to an electro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/4/001

    authors: Kezerashvili M,Bednarek DR,Rudin S

    更新日期:1997-04-01 00:00:00

  • Treatment time reduction for large thermal lesions by using a multiple 1D ultrasound phased array system.

    abstract::To generate large thermal lesions in ultrasound thermal therapy, cooling intermissions are usually introduced during the treatment to prevent near-field heating, which leads to a long treatment time. A possible strategy to shorten the total treatment time is to eliminate the cooling intermissions. In this study, the t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/9/307

    authors: Liu HL,Chen YY,Yen JY,Lin WL

    更新日期:2003-05-07 00:00:00

  • Elastography--the movement begins.

    abstract::The advent of real-time ultrasound in the 1970s, together with a growing interest in tissue characterization, led to a number of investigators using the nature of tissue motion to distinguish healthy from diseased tissue. Our group at the (then) Ultrasonics Institute demonstrated the use of phase methods for detecting...

    journal_title:Physics in medicine and biology

    pub_type: 历史文章,杂志文章

    doi:10.1088/0031-9155/45/6/301

    authors: Wilson LS,Robinson DE,Dadd MJ

    更新日期:2000-06-01 00:00:00

  • Optical properties of porcine skin dermis between 900 nm and 1500 nm.

    abstract::The weak absorption of shortwave infrared light by skin tissues between 700 and 1500 nm offers an important window for diagnosis by optical means. The strong scattering of shortwave infrared light by the skin, however, presents a challenge to the modelling of light propagation through the skin and the understanding of...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/1/312

    authors: Du Y,Hu XH,Cariveau M,Ma X,Kalmus GW,Lu JQ

    更新日期:2001-01-01 00:00:00

  • PETSIM: Monte Carlo simulation of all sensitivity and resolution parameters of cylindrical positron imaging systems.

    abstract::Monte Carlo simulation techniques are applied to track the annihilation photons from positron decay, and store the photon histories. Reasonably realistic models of the isotope distribution in the brain and heart during typical PET studies, as well as the traditional phantoms used for measuring PET scanner performance ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/3/017

    authors: Thompson CJ,Moreno-Cantu J,Picard Y

    更新日期:1992-03-01 00:00:00

  • Long-length tomosynthesis and 3D-2D registration for intraoperative assessment of spine instrumentation.

    abstract:PURPOSE:A system for long-length intraoperative imaging is reported based on longitudinal motion of an O-arm gantry featuring a multi-slot collimator. We assess the utility of long-length tomosynthesis and the geometric accuracy of 3D image registration for surgical guidance and evaluation of long spinal constructs. M...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abde96

    authors: Zhang X,Uneri A,Wu P,Ketcha MD,Jones C,Huang Y,Lo SL,Helm PA,Siewerdsen JH

    更新日期:2021-01-21 00:00:00

  • Reconstructing uniformly attenuated rotating slant-hole SPECT projection data using the DBH method.

    abstract::This work applies a previously developed analytical algorithm to the reconstruction problem in a rotating multi-segment slant-hole (RMSSH) SPECT system. The RMSSH collimator has greater detection efficiency than the parallel-hole collimator with comparable spatial resolution at the expense of limited common volume-of-...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/13/024

    authors: Huang Q,Xu J,Tsui BM,Gullberg GT

    更新日期:2009-07-07 00:00:00

  • A novel approach with dual-sampling convolutional neural network for ultrasound image classification of breast tumors.

    abstract::Breast cancer is one of the leading causes of female cancer deaths. Early diagnosis with prophylactic may improve the patients' prognosis. So far ultrasound (US) imaging is a popular method in breast cancer diagnosis. However, its accuracy is bounded to traditional handcrafted feature methods and expertise. A novel me...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abc5c7

    authors: Xie J,Song X,Zhang W,Dong Q,Wang Y,Li F,Wan C

    更新日期:2020-10-29 00:00:00

  • A study of potential numerical pitfalls in GPU-based Monte Carlo dose calculation.

    abstract::The purpose of this study was to evaluate the impact of numerical errors caused by the floating point representation of real numbers in a GPU-based Monte Carlo code used for dose calculation in radiation oncology, and to identify situations where this type of error arises. The program used as a benchmark was bGPUMCD. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/13/5007

    authors: Magnoux V,Ozell B,Bonenfant É,Després P

    更新日期:2015-07-07 00:00:00

  • A determination by an analysis of X-ray attenuation in aluminium of the intesity distribution at its point of origin in a thick tungsten target of bremsstrahlung excited by constant potentials of 60-140 kV.

    abstract::A recently described, computer aided method of attenuation analysis has been applied to free-air chamber measurements of the attenuation by up to 30mm A1 of the exposure rate of a narrow beam of X-radiation excited at a thick W target in a Be window tube by constant potentials of 60, 80, 100, 120 and 140 kV. It has ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/22/2/001

    authors: Soole BW

    更新日期:1977-03-01 00:00:00

  • Influence of sulphuric acid contaminants on Fricke dosimetry.

    abstract::The sulphuric acid used for the preparation of the Fricke dosimeter solution may contain trace impurities that can affect the yield of ferric ions. Two methods, pre-irradiation or oxidation with hydrogen peroxide, have been proposed to reduce the influence of these impurities. Fricke users sometimes omit this treatmen...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/9/403

    authors: Palm A,Mattsson O

    更新日期:2000-09-01 00:00:00

  • Hysteresis heating for the treatment of tumours.

    abstract::A method is described whereby, utilising a biocompatible magnetic glass-ceramic material, effective hysteresis heating in living tissue was accomplished. Initial experiments on mice showed that a significant heating effect can be obtained in the ceramic-impregnated regions. An analysis is also given for the projected ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/5/001

    authors: Borrelli NF,Luderer AA,Panzarino JN

    更新日期:1984-05-01 00:00:00

  • Effect of blood perfusion on the ablation of liver parenchyma with high-intensity focused ultrasound.

    abstract::This paper discusses the effect of blood perfusion on the ablation of rat liver tissue with high-intensity focused ultrasound (HIFU). For this study a practical method has been developed, in which the liver blood flow can be reduced by ligation of the hepatic artery and portal vein. During the treatment the rat liver ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/38/11/011

    authors: Chen L,ter Haar G,Hill CR,Dworkin M,Carnochan P,Young H,Bensted JP

    更新日期:1993-11-01 00:00:00

  • Robust fluence map optimization via alternating direction method of multipliers with empirical parameter optimization.

    abstract::For the treatment planning during intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT), beam fluence maps can be first optimized via fluence map optimization (FMO) under the given dose prescriptions and constraints to conformally deliver the radiation dose to the targets while sparin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/7/2838

    authors: Gao H

    更新日期:2016-04-07 00:00:00

  • Plane wave versus focused transmissions for contrast enhanced ultrasound imaging: the role of parameter settings and the effects of flow rate on contrast measurements.

    abstract::Contrast enhanced ultrasound (CEUS) and dynamic contrast enhanced ultrasound (DCE-US) can be used to provide information about the vasculature aiding diagnosis and monitoring of a number of pathologies including cancer. In the development of a CEUS imaging system, there are many choices to be made, such as whether to ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab13f2

    authors: Moghimirad E,Bamber J,Harris E

    更新日期:2019-04-23 00:00:00

  • Segmentation and classification of thyroid follicular neoplasm using cascaded convolutional neural network.

    abstract::In this paper, we present a segmentation and classification method for thyroid follicular neoplasms based on a combination of the prior-based level set method and deep convolutional neural network. The proposed method aims to discriminate thyroid follicular adenoma (TFA) and follicular thyroid carcinoma (FTC) in ultra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abc6f2

    authors: Yang B,Yan M,Yan Z,Zhu C,Xu D,Dong F

    更新日期:2020-11-02 00:00:00

  • First experimental evidence of the feasibility of multi-color magnetic particle imaging.

    abstract::Magnetic particle imaging is a new approach to visualizing magnetic nanoparticles. It is capable of 3D real-time in vivo imaging of particles injected into the blood stream and is a candidate for medical imaging applications. To date, only one particle type has been imaged at a time, however, the ability to separate s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/5/1775

    authors: Rahmer J,Halkola A,Gleich B,Schmale I,Borgert J

    更新日期:2015-03-07 00:00:00

  • Simultaneous Tc-99m/I-123 dual-radionuclide myocardial perfusion/innervation imaging using Siemens IQ-SPECT with SMARTZOOM collimator.

    abstract::Simultaneous dual-radionuclide myocardial perfusion/innervation SPECT imaging can provide important information about the mismatch between scar tissue and denervated regions. The Siemens IQ-SPECT system developed for cardiac imaging uses a multifocal SMARTZOOM collimator to achieve a four-fold sensitivity for the card...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/11/2813

    authors: Du Y,Bhattacharya M,Frey EC

    更新日期:2014-06-07 00:00:00

  • A novel single-ended readout depth-of-interaction PET detector fabricated using sub-surface laser engraving.

    abstract::We propose a novel scintillation detector design for positron emission tomography (PET), which has depth of interaction (DOI) capability and uses a single-ended readout scheme. The DOI detector contains a pair of crystal bars segmented using sub-surface laser engraving (SSLE). The two crystal bars are optically couple...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/18/6635

    authors: Uchida H,Sakai T,Yamauchi H,Hakamata K,Shimizu K,Yamashita T

    更新日期:2016-09-21 00:00:00

  • Electromagnetic redesign of the HYPERcollar applicator: toward improved deep local head-and-neck hyperthermia.

    abstract::Accumulating evidence shows that hyperthermia improves head-and-neck cancer treatment. Over the last decade, we introduced a radiofrequency applicator, named HYPERcollar, which enables local heating also of deep locations in this region. Based on clinical experience, we redesigned the HYPERcollar for improved comfort,...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/17/5997

    authors: Togni P,Rijnen Z,Numan WC,Verhaart RF,Bakker JF,van Rhoon GC,Paulides MM

    更新日期:2013-09-07 00:00:00

  • Three-dimensional optical tomography of the premature infant brain.

    abstract::For the first time, three-dimensional images of the newborn infant brain have been generated using measurements of transmitted light. A 32-channel time-resolved imaging system was employed, and data were acquired using custom-made helmets which couple source fibres and detector bundles to the infant head. Images have ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/23/303

    authors: Hebden JC,Gibson A,Yusof RM,Everdell N,Hillman EM,Delpy DT,Arridge SR,Austin T,Meek JH,Wyatt JS

    更新日期:2002-12-07 00:00:00

  • Thermoluminescent response and relative efficiency of TLD-100 exposed to low-energy x-rays.

    abstract::The dose-response of LiF:Mg,Ti (TLD-100) exposed to 15 and 35 kVp (8.0 +/- 0.1 and 8.1 +/- 0.1 keV effective energy respectively) x-rays and 60Co gamma-rays has been measured in the dose interval from (1.2-5.4) x 10(3) Gy for x-rays, and from 0.14 to 850 Gy for gamma-rays. In both cases the total TL signal and glow cu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/8/006

    authors: Gamboa-deBuen I,Buenfil AE,Ruiz CG,Rodríguez-Villafuerte M,Flores A,Brandan ME

    更新日期:1998-08-01 00:00:00

  • Specific absorbed fractions for a revised series of the UF/NCI pediatric reference phantoms: internal photon sources.

    abstract::Assessment of radiation absorbed dose to internal organs of the body from the intake of radionuclides or, in the medical setting through the injection of radiopharmaceuticals, is generally performed based upon reference biokinetic models or patient imaging data, respectively. Biokinetic models estimate the time course...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abc708

    authors: Schwarz BC,Godwin WJ,Wayson MB,Dewji SA,Jokisch DW,Lee C,Bolch WE

    更新日期:2020-11-03 00:00:00

  • Dosimetry for the MRI accelerator: the impact of a magnetic field on the response of a Farmer NE2571 ionization chamber.

    abstract::The UMC Utrecht is constructing a 1.5 T MRI scanner integrated with a linear accelerator (Lagendijk et al 2008 Radiother. Oncol. 86 25-9). The goal of this device is to facilitate soft-tissue contrast based image-guided radiotherapy, in order to escalate the dose to the tumour while sparing surrounding normal tissues....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/10/002

    authors: Meijsing I,Raaymakers BW,Raaijmakers AJ,Kok JG,Hogeweg L,Liu B,Lagendijk JJ

    更新日期:2009-05-21 00:00:00

  • Monte Carlo-based evaluation of S-values in mouse models for positron-emitting radionuclides.

    abstract::In addition to being a powerful clinical tool, Positron emission tomography (PET) is also used in small laboratory animal research to visualize and track certain molecular processes associated with diseases such as cancer, heart disease and neurological disorders in living small animal models of disease. However, dosi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/1/169

    authors: Xie T,Zaidi H

    更新日期:2013-01-07 00:00:00

  • Optical-coherence tomography of a dense tissue: statistics of attenuation and backscattering.

    abstract::This paper addresses fundamental issues that underlie the interpretation of images acquired from turbid tissues by optical-coherence tomography (OCT). The attenuation and backscattering properties of freshly excised rat arteries and their dependence on the focusing and collection optics of the OCT system were measured...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/10/013

    authors: Schmitt JM,Knüttel A,Yadlowsky M,Eckhaus MA

    更新日期:1994-10-01 00:00:00

  • An investigation into the vector ellipticity of extremely low frequency magnetic fields from appliances in UK homes.

    abstract::Elliptically polarized magnetic fields induce higher currents in the body compared with their plane polarized counterparts. This investigation examines the degree of vector ellipticity of extremely low frequency magnetic fields (ELF-MFs) in the home, with regard to the adverse health effects reportedly associated with...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/13/016

    authors: Ainsbury EA,Conein E,Henshaw DL

    更新日期:2005-07-07 00:00:00

  • Potential for reducing the numbers of SiPM readout surfaces of laser-processed X'tal cube PET detectors.

    abstract::We are developing a three-dimensional (3D) position-sensitive detector with isotropic spatial resolution, the X'tal cube. Originally, our design consisted of a crystal block for which all six surfaces were covered with arrays of multi-pixel photon counters (MPPCs). In this paper, we examined the feasibility of reducin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/5/1361

    authors: Hirano Y,Inadama N,Yoshida E,Nishikido F,Murayama H,Watanabe M,Yamaya T

    更新日期:2013-03-07 00:00:00