Computational fluid dynamics modelling of perfusion measurements in dynamic contrast-enhanced computed tomography: development, validation and clinical applications.

Abstract:

:Dynamic contrast-enhanced computed tomography (DCE-CT) is an imaging tool that aids in evaluating functional characteristics of tissue at different stages of disease management: diagnostic, radiation treatment planning, treatment effectiveness, and monitoring. Clinical validation of DCE-derived perfusion parameters remains an outstanding problem to address prior to perfusion imaging becoming a widespread standard as a non-invasive quantitative measurement tool. One approach to this validation process has been the development of quality assurance phantoms in order to facilitate controlled perfusion ex vivo. However, most of these systems fail to establish and accurately replicate physiologically relevant capillary permeability and exchange performance. The current work presents the first step in the development of a prospective suite of physics-based perfusion simulations based on coupled fluid flow and particle transport phenomena with the goal of enhancing the understanding of clinical contrast agent kinetics. Existing knowledge about a controllable, two-compartmental fluid exchange phantom was used to validate the computational fluid dynamics (CFD) simulation model presented herein. The sensitivity of CFD-derived contrast uptake curves to contrast injection parameters, including injection duration and flow rate, were quantified and found to be within 10% accuracy. The CFD model was employed to evaluate two commonly used clinical kinetic algorithms used to derive perfusion parameters: Fick's principle and the modified Tofts model. Neither kinetic model was able to capture the true transport phenomena it aimed to represent but if the overall contrast concentration after injection remained identical, then successive DCE-CT evaluations could be compared and could indeed reflect differences in regional tissue flow. This study sets the groundwork for future explorations in phantom development and pharmaco-kinetic modelling, as well as the development of novel contrast agents for DCE imaging.

journal_name

Phys Med Biol

authors

Peladeau-Pigeon M,Coolens C

doi

10.1088/0031-9155/58/17/6111

subject

Has Abstract

pub_date

2013-09-07 00:00:00

pages

6111-31

issue

17

eissn

0031-9155

issn

1361-6560

journal_volume

58

pub_type

杂志文章
  • A new method to reconstruct intra-fractional prostate motion in volumetric modulated arc therapy.

    abstract::Intra-fractional motion is a concern during prostate radiation therapy, as it may cause deviations between planned and delivered radiation doses. Because accurate motion information during treatment delivery is critical to address dose deviation, we developed the projection marker matching method (PM3), a novel method...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6e37

    authors: Chi Y,Rezaeian NH,Shen C,Zhou Y,Lu W,Yang M,Hannan R,Jia X

    更新日期:2017-07-07 00:00:00

  • Influence of source parameters on large-field electron beam profiles calculated using Monte Carlo methods.

    abstract::The purpose of this paper was to study the source model for a Monte Carlo simulation of electron beams from a medical linear accelerator. In a prior study, a non-divergent Gaussian source with a full-width at half-maximum (FWHM) of 0.15 cm was successful in predicting relative dose distributions for electron beams wit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/1/007

    authors: Weinberg R,Antolak JA,Starkschall G,Kudchadker RJ,White RA,Hogstrom KR

    更新日期:2009-01-07 00:00:00

  • Accurate Monte Carlo modelling of the back compartments of SPECT cameras.

    abstract::Today, new single photon emission computed tomography (SPECT) reconstruction techniques rely on accurate Monte Carlo (MC) simulations to optimize reconstructed images. However, existing MC scintillation camera models which usually include an accurate description of the collimator and crystal, lack correct implementati...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/1/006

    authors: Rault E,Staelens S,Van Holen R,De Beenhouwer J,Vandenberghe S

    更新日期:2011-01-07 00:00:00

  • An alternative to gamma histograms for ROI-based quantitative dose comparisons.

    abstract::An alternative to gamma (gamma) histograms for ROI-based quantitative comparisons of dose distributions using the gamma concept is proposed. The method provides minimum values of dose difference and distance-to-agreement such that a pre-set fraction of the region of interest passes the gamma test. Compared to standard...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/12/N03

    authors: Dvorak P

    更新日期:2009-06-21 00:00:00

  • Changes in lung tumor shape during respiration.

    abstract::Evidence that some lung tumors change shape during respiration is derived from respiratory gated CT data by statistical shape modeling and image manipulation. Some tumors behave as rigid objects while others show systematic shape changes. Two views of lung motion are presented to allow analysis of the results. In the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/4/919

    authors: Kyriakou E,McKenzie DR

    更新日期:2012-02-21 00:00:00

  • Scatter correction of cone-beam CT using a deep residual convolution neural network (DRCNN).

    abstract::Scatter correction is an essential technique to improve the image quality of cone-beam CT (CBCT). Although different scatter correction methods have been proposed in the literature, a standard solution is still being studied due to the limitations including accuracy, computation efficiency and generalization. In this ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab23a6

    authors: Jiang Y,Yang C,Yang P,Hu X,Luo C,Xue Y,Xu L,Hu X,Zhang L,Wang J,Sheng K,Niu T

    更新日期:2019-07-11 00:00:00

  • Modelling of temperature and perfusion during scalp cooling.

    abstract::Hair loss is a feared side effect of chemotherapy treatment. It may be prevented by cooling the scalp during administration of cytostatics. The supposed mechanism is that by cooling the scalp, both temperature and perfusion are diminished, affecting drug supply and drug uptake in the hair follicle. However, the effect...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/17/010

    authors: Janssen FE,Van Leeuwen GM,Van Steenhoven AA

    更新日期:2005-09-07 00:00:00

  • Influence of anisotropic compartments on magnetic field and electric potential distributions generated by artificial current dipoles inside a torso phantom.

    abstract::The purpose of this study is the analysis of the influence of anisotropic conductivity on magnetic fields and electric potentials by means of phantom measurements. An artificial rotating current dipole was placed in the middle of an anisotropic skein arrangement in a torso phantom filled with saline solution. The sign...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/1/017

    authors: Liehr M,Haueisen J

    更新日期:2008-01-07 00:00:00

  • Radioluminescence in biomedicine: physics, applications, and models.

    abstract::The electromagnetic spectrum contains different frequency bands useful for medical imaging and therapy. Short wavelengths (ionizing radiation) are commonly used for radiological and radionuclide imaging and for cancer radiation therapy. Intermediate wavelengths (optical radiation) are useful for more localized imaging...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/1361-6560/aaf4de

    authors: Klein JS,Sun C,Pratx G

    更新日期:2019-02-06 00:00:00

  • Effect of electron contamination of a 6 MV x-ray beam on near surface diode dosimetry.

    abstract::In critical organ in vivo x-ray dosimetry, the relative contaminating electron contribution to the total dose and total detector response outside the field will be different to the corresponding contributions at the central axis detector calibration position, mainly due to the effects of shielding in the linear accele...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/24/013

    authors: Edwards CR,Mountford PJ,Moloney AJ

    更新日期:2006-12-21 00:00:00

  • Detector arrangement and sampling characteristics in rotary positron-emission computed tomography.

    abstract::A rotary positron-emission computed tomography system has been proposed in which detectors are mounted unequally spaced on a ring, so as to provide fine and uniform linear sampling during a 360 degree rotation of the ring around its centre. The usefulness of a simple iterative method for searching for a suitable arran...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/26/3/011

    authors: Yamamoto M

    更新日期:1981-05-01 00:00:00

  • Measurement of calcium in sections of a human skeleton using a reactor spectrum-in vivo activation analysis technique.

    abstract::Factors influencing the precision of measuring changes in the calcium content of sections of bone, including vertebrae, using reactor neutrons for partial body in vivo activation analysis have been examined and quantified. These factors include (a) the choice of incidient neutron spectrum, (b) the uniformity of activa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/20/1/007

    authors: Boddy K,Glaros D,Robertson I

    更新日期:1975-01-01 00:00:00

  • Image-based point spread function implementation in a fully 3D OSEM reconstruction algorithm for PET.

    abstract::The interest in positron emission tomography (PET) and particularly in hybrid integrated PET/CT systems has significantly increased in the last few years due to the improved quality of the obtained images. Nevertheless, one of the most important limits of the PET imaging technique is still its poor spatial resolution ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/14/012

    authors: Rapisarda E,Bettinardi V,Thielemans K,Gilardi MC

    更新日期:2010-07-21 00:00:00

  • Towards a gold standard for quantitative coronary arteriography.

    abstract::Densitometric quantification of coronary artery stenoses in angiographic images can be problematic for two reasons: (i) the x-rays are inadequately oriented with respect to the vessel segments of interest at image acquisition; (ii) non-linear effects due for instance to beam hardening, scattered radiation and veiling ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/12/011

    authors: Doriot PA,Dorsaz PA,Dorsaz L,Bodenmann JJ

    更新日期:1997-12-01 00:00:00

  • Evaluation of multiple-sphere head models for MEG source localization.

    abstract::Magnetoencephalography (MEG) source analysis has largely relied on spherical conductor models of the head to simplify forward calculations of the brain's magnetic field. Multiple- (or overlapping, local) sphere models, where an optimal sphere is selected for each sensor, are considered an improvement over single-spher...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/17/010

    authors: Lalancette M,Quraan M,Cheyne D

    更新日期:2011-09-07 00:00:00

  • Monte Carlo correction factors for a Farmer 0.6 cm3 ion chamber dose measurement in the build-up region of the 6 MV clinical beam.

    abstract::Reference dosimetry of photon fields is a well-established subject and currently available protocols (such as the IAEA TRS-398 and AAPM TG-51) provide methods for converting the ionization chamber (IC) reading into dose to water, provided reference conditions of charged particle equilibrium (CPE) are fulfilled. But th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/6/011

    authors: Pena J,Sánchez-Doblado F,Capote R,Terrón JA,Gómez F

    更新日期:2006-03-21 00:00:00

  • DAVID--a translucent multi-wire transmission ionization chamber for in vivo verification of IMRT and conformal irradiation techniques.

    abstract::Permanent in vivo verification of IMRT photon beam profiles by a radiation detector with spatial resolution, positioned on the radiation entrance side of the patient, has not been clinically available so far. In this work we present the DAVID system, which is able to perform this quality assurance measurement while th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/5/013

    authors: Poppe B,Thieke C,Beyer D,Kollhoff R,Djouguela A,Rühmann A,Willborn KC,Harder D

    更新日期:2006-03-07 00:00:00

  • Analytical modeling of relative luminescence efficiency of Al2O3:C optically stimulated luminescence detectors exposed to high-energy heavy charged particles.

    abstract::The objective of this work is to test analytical models to calculate the luminescence efficiency of Al(2)O(3):C optically stimulated luminescence detectors (OSLDs) exposed to heavy charged particles with energies relevant to space dosimetry and particle therapy. We used the track structure model to obtain an analytica...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/2/437

    authors: Sawakuchi GO,Yukihara EG

    更新日期:2012-01-21 00:00:00

  • In vivo cerebrovascular measurement combining diffuse near-infrared absorption and correlation spectroscopies.

    abstract::We combine two near-infrared diffuse optical techniques to study variations of blood flow, haemoglobin concentration, and blood oxygen saturation in the functioning rat brain. Diffuse correlation spectroscopy (or flowmetry) monitors changes in the cerebral blood flow, without the use of the principles of tracer cleara...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/8/302

    authors: Cheung C,Culver JP,Takahashi K,Greenberg JH,Yodh AG

    更新日期:2001-08-01 00:00:00

  • Novel method to calculate pulmonary compliance images in rodents from computed tomography acquired at constant pressures.

    abstract::Our goal was to develop a method for generating high-resolution three-dimensional pulmonary compliance images in rodents from computed tomography (CT) images acquired at a series of constant pressures in ventilated animals. One rat and one mouse were used to demonstrate this technique. A pre-clinical GE flat panel CT ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/5/003

    authors: Guerrero T,Castillo R,Sanders K,Price R,Komaki R,Cody D

    更新日期:2006-03-07 00:00:00

  • A Monte Carlo-based method to estimate radiation dose from spiral CT: from phantom testing to patient-specific models.

    abstract::The purpose of this work is to develop and test a method to estimate the relative and absolute absorbed radiation dose from axial and spiral CT scans using a Monte Carlo approach. Initial testing was done in phantoms and preliminary results were obtained from a standard mathematical anthropomorphic model (MIRD V) and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/16/306

    authors: Jarry G,DeMarco JJ,Beifuss U,Cagnon CH,McNitt-Gray MF

    更新日期:2003-08-21 00:00:00

  • Multi-frequency characterization of the speed of sound and attenuation coefficient for longitudinal transmission of freshly excised human skulls.

    abstract::For medical applications of ultrasound inside the brain, it is necessary to understand the relationship between the apparent density of skull bone and its corresponding speed of sound and attenuation coefficient. Although there have been previous studies exploring this phenomenon, there is still a need to extend the m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/1/014

    authors: Pichardo S,Sin VW,Hynynen K

    更新日期:2011-01-07 00:00:00

  • Comparative study of a low-Z cone-beam computed tomography system.

    abstract::Computed tomography images have been acquired using an experimental (low atomic number (Z) insert) megavoltage cone-beam imaging system. These images have been compared with standard megavoltage and kilovoltage imaging systems. The experimental system requires a simple modification to the 4 MeV electron beam from an E...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/14/014

    authors: Roberts DA,Hansen VN,Thompson MG,Poludniowski G,Niven A,Seco J,Evans PM

    更新日期:2011-07-21 00:00:00

  • A comparison between track-structure, condensed-history Monte Carlo simulations and MIRD cellular S-values.

    abstract::The S-value is a standard measure in cellular dosimetry. S-values are calculated by applying analytical methods or by Monte Carlo simulation. In Monte Carlo simulation, particles are either tracked individually event-by-event or close events are condensed and processed collectively in different steps. Both of these me...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/62/5/N90

    authors: Tajik-Mansoury MA,Rajabi H,Mozdarani H

    更新日期:2017-03-07 00:00:00

  • Magnetorelaxometric quantification of magnetic nanoparticles in an artery model after ex vivo magnetic drug targeting.

    abstract::In magnetic drug targeting a chemotherapeutic agent is bound to coated magnetic nanoparticles, which are administered to the blood vessel system and subsequently focused by an external applied magnetic field. The optimization of intra-arterial magnetic drug targeting (MDT) requires detailed knowledge about the biodist...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/18/N03

    authors: Richter H,Wiekhorst F,Schwarz K,Lyer S,Tietze R,Alexiou Ch,Trahms L

    更新日期:2009-09-21 00:00:00

  • Obtaining breathing patterns from any sequential thoracic x-ray image set.

    abstract::A technique is presented to allow a breathing pattern to be obtained from any multi-slice CT, cone-beam or other series of sequential chest x-ray image sets. The technique requires no extra signals to be recorded and does not need specific external or internal oscillating structures to be visible in the field of view....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/16/003

    authors: Kavanagh A,Evans PM,Hansen VN,Webb S

    更新日期:2009-08-21 00:00:00

  • Depth of ionization chamber in water.

    abstract::The device developed by the authors and described here enables the user to measure the depth from the water surface to the point of measurement for a cylindrical ion chamber with a waterproof plastic cap in a water phantom, free of surface-tension error with a high precision. The device seeks vertical orientation and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/8/007

    authors: Tailor RC,Tello VM

    更新日期:1995-08-01 00:00:00

  • Influence of the surface averaging procedure of the current density in assessing compliance with the ICNIRP low-frequency basic restrictions by means of numerical techniques.

    abstract::Although the calculation of the surface average of the low-frequency current density distribution over a cross-section of 1 cm2 is required by ICNIRP guidelines, no reference averaging algorithm is indicated, neither in the ICNIRP guidelines nor in the Directive 2004/40/EC that is based on them. The lack of a general ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/15/013

    authors: Zoppetti N,Andreuccetti D

    更新日期:2009-08-07 00:00:00

  • Measurement of the mass energy-absorption coefficient of air for x-rays in the range from 3 to 60 keV.

    abstract::For the first time the absolute photon mass energy-absorption coefficient of air in the energy range of 10 to 60 keV has been measured with relative standard uncertainties below 1%, considerably smaller than those of up to 2% assumed for calculated data. For monochromatized synchrotron radiation from the electron stor...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/24/8231

    authors: Buhr H,Büermann L,Gerlach M,Krumrey M,Rabus H

    更新日期:2012-12-21 00:00:00

  • The influence of metal artefacts on the range of ion beams.

    abstract::The influence of artefacts due to metal implants on the range of ion beams is investigated, using a geometrically well-defined head and pelvic phantom together with inserts from steel, titanium and tungsten. The ranges along various beam paths including artefacts were calculated from the TPS and compared to known calc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/3/007

    authors: Jäkel O,Reiss P

    更新日期:2007-02-07 00:00:00