Abstract:
:An alternative to gamma (gamma) histograms for ROI-based quantitative comparisons of dose distributions using the gamma concept is proposed. The method provides minimum values of dose difference and distance-to-agreement such that a pre-set fraction of the region of interest passes the gamma test. Compared to standard gamma histograms, the method provides more information in terms of pass rate per gamma calculation. This is achieved at negligible additional calculation cost and without loss of accuracy. The presented method is proposed as a useful and complementary alternative to standard gamma histograms, increasing both the quantity and quality of information for use in acceptance or rejection decisions.
journal_name
Phys Med Bioljournal_title
Physics in medicine and biologyauthors
Dvorak Pdoi
10.1088/0031-9155/54/12/N03subject
Has Abstractpub_date
2009-06-21 00:00:00pages
N247-54issue
12eissn
0031-9155issn
1361-6560pii
S0031-9155(09)02192-7journal_volume
54pub_type
杂志文章abstract::In order to analyse the respective roles of ion concentration and fractional volume of the interstitial compartment as determinants of the impedance, Z, of renal medullary tissue, a model was needed in which both these factors could be varied independently. An array of blood cell suspensions ions in saline (different ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/35/11/011
更新日期:1990-11-01 00:00:00
abstract::Many models exist for predicting toxicities based on dose-volume histograms (DVHs) or dose-surface histograms (DSHs). This approach has several drawbacks as firstly the reduction of the dose distribution to a histogram results in the loss of spatial information and secondly the bins of the histograms are highly correl...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/7/013
更新日期:2011-04-07 00:00:00
abstract::Grating interferometry is advantageous over conventional x-ray absorption imaging because it enables the detection of samples constituted by low atomic number elements (low-Z materials). Therefore, it has a potential application in biological science and medical diagnostics. The grating interferometry has some critica...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/61/23/8266
更新日期:2016-12-07 00:00:00
abstract::All radiation therapy treatment planning relies on accurate dose calculation. Uncertainties in dosimetric prediction can significantly degrade an otherwise optimal plan. In this work, we introduce a robust optimization method which handles dosimetric errors and warrants for high-quality IMRT plans. Unlike other dose e...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/11/010
更新日期:2009-06-07 00:00:00
abstract::The purpose of this study was to derive a complete set of correction and perturbation factors for output factors (OF) and dose profiles. Modern small field detectors were investigated including a plastic scintillator (Exradin W1, SI), a liquid ionization chamber (microLion 31018, PTW), an unshielded diode (Exradin D1V...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/19/5937
更新日期:2014-10-07 00:00:00
abstract::A number of radiation-therapy-related uses based on a commercially available spreadsheet program have been developed at our facility. The graphics and display capabilities inherent in these spreadsheet programs allow for concise visual results. The spreadsheets are used as an independent check for several types of rad...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/40/6/007
更新日期:1995-06-01 00:00:00
abstract::It was observed that the radiation output of x-ray tubes falls off exponentially during an exposure with a time constant of about 120 ms. The equilibrium value is approximately 15% lower than that at the beginning of the exposure. The clinically noticeable consequences are discrepancies in x-ray generator calibration,...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/25/2/004
更新日期:1980-03-01 00:00:00
abstract::This paper describes a neural network (NN) regression model for relative dose computation. The input signal of the NN model includes depths and field sizes and the output is the relative dose, for example, percentage depth dose (%DD) or tissue-air ratio (TAR) in this paper. After a functional link has been created, th...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/45/4/307
更新日期:2000-04-01 00:00:00
abstract::While megavoltage cone-beam computed tomography (CBCT) using an electronic portal imaging device (EPID) provides many advantages over kilovoltage (kV) CBCT, clinical adoption is limited by its high doses. Multi-layer imager (MLI) EPIDs increase DQE(0) while maintaining high resolution. However, even well-designed, hig...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aaa160
更新日期:2018-01-30 00:00:00
abstract::Noise equivalent count rate (NECR) and image noise are two different but related metrics that have been used to predict and assess image quality, respectively. The aim of this study is to investigate, using patient studies, the relationships between injected dose (ID), body mass index (BMI) and scanner type on NECR an...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/16/013
更新日期:2011-08-21 00:00:00
abstract::Accurate scatter compensation in SPECT can be performed by modelling the scatter response function during the reconstruction process. This method is called reconstruction-based scatter compensation (RBSC). It has been shown that RBSC has a number of advantages over other methods of compensating for scatter, but using ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/43/4/014
更新日期:1998-04-01 00:00:00
abstract::For treatments with dynamic intensity modulated radiotherapy (IMRT), the adjustment of multileaf collimator (MLC) parameters affecting both the optimization algorithm and dose distributions is crucial. The main parameters characterizing the MLC are the transmission (T) and the dosimetric leaf separation (DLS). The aim...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/50/4/001
更新日期:2005-02-21 00:00:00
abstract::We report on a radiographic measurement of an ex vivo human knee using a grating-based phase-contrast imaging setup and a medical x-ray tube at a tube voltage of 70 kV. The measurement has been carried out using a Talbot-Lau setup that is suitable to achieve a high visibility in the energy regime of medical imaging. I...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa7721
更新日期:2017-08-01 00:00:00
abstract::In radiation therapy, a plan is robust if the calculated and the delivered dose are in agreement, even in the case of different uncertainties. The current practice is to use safety margins, expanding the clinical target volume sufficiently enough to account for treatment uncertainties. This, however, might not be idea...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/14/011
更新日期:2011-07-21 00:00:00
abstract::The spatial resolution of 2D detector arrays equipped with ionization chambers or diodes, used for the dose verification of IMRT treatment plans, is limited by the size of the single detector and the centre-to-centre distance between the detectors. Optimization criteria with regard to these parameters have been develo...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/10/019
更新日期:2007-05-21 00:00:00
abstract::This paper introduces a novel compartmental model describing the excretion of 18F-fluoro-deoxyglucose (FDG) in the renal system and a numerical method based on the maximum likelihood for its reduction. This approach accounts for variations in FDG concentration due to water re-absorption in renal tubules and the increa...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/10/2469
更新日期:2014-05-21 00:00:00
abstract::The beam orientation optimization (BOO) problem in intensity modulated radiation therapy (IMRT) treatment planning is a nonlinear problem, and existing methods to obtain solutions to the BOO problem are time consuming due to the complex nature of the objective function and size of the solution space. These issues beco...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/17/014
更新日期:2011-09-07 00:00:00
abstract::The dynamic collimation system (DCS) can be combined with pencil beam scanning proton therapy to deliver highly conformal treatment plans with unique collimation at each energy layer. This energy layer-specific collimation is accomplished through the synchronized motion of four trimmer blades that intercept the proton...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab416d
更新日期:2019-10-21 00:00:00
abstract::A phantom study for dosimetry in the urethra using alanine/ESR during (192)Ir HDR brachytherapy of prostate cancer is presented. The measurement method of the secondary standard of the Physikalisch-Technische Bundesanstalt had to be slightly modified in order to be able to measure inside a Foley catheter. The absorbed...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/9/022
更新日期:2009-05-07 00:00:00
abstract::This study introduces a practical four-dimensional (4D) planning scheme of IMAT using 4D computed tomography (4D CT) for planning tumor tracking with dynamic multileaf beam collimation. We assume that patients can breathe regularly, i.e. the same way as during 4D CT with an unchanged period and amplitude, and that the...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa56b7
更新日期:2017-02-21 00:00:00
abstract::Transcranial direct current stimulation (tDCS) is a neuromodulation scheme where a small current is delivered to the brain via two electrodes attached to the scalp. The electrode design is an important topic, not only as regards efficacy, but also from a safety perspective, as tDCS may be related to skin lesions that ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/61/24/8825
更新日期:2016-12-21 00:00:00
abstract::In carbon-ion radiotherapy, single-beam delivery each day in alternate directions has been common practice for efficient operation, taking advantage of the Bragg peak and the relative biological effectiveness (RBE) for uniform dose conformation to a tumor. Treatments are usually fractionated and treatment plans are ev...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/62/3/1062
更新日期:2017-02-07 00:00:00
abstract::In this study, the quantitative accuracy of different attenuation correction strategies presently available for the High Resolution Research Tomograph (HRRT) was investigated. These attenuation correction methods differ in reconstruction and processing (segmentation) algorithms used for generating a micro-image from m...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/1/007
更新日期:2008-01-07 00:00:00
abstract::A comprehensive set of measurements and calculations has been conducted to investigate the accuracy of the Dose Planning Method (DPM) Monte Carlo code for electron beam dose calculations in heterogeneous media. Measurements were made using 10 MeV and 50 MeV minimally scattered, uncollimated electron beams from a racet...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/47/11/301
更新日期:2002-06-07 00:00:00
abstract::This paper evaluates the performance of two large-area position-sensitive solid-state photomultipliers (PS-SSPM) for use in small animal PET detector designs. Both PS-SSPM device designs are 1 cm² in area, the first being a 2 × 2 tiled array of 5 mm × 5 mm PS-SSPMs and the second being a 10 mm × 10 mm continuous PS-SS...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/24/8119
更新日期:2012-12-21 00:00:00
abstract::In a previous paper, we described quality assurance procedures for Hi-Art helical tomotherapy machines. Here, we develop further some ideas discussed briefly in that paper. Simple helically generated dose distributions are modelled, and relationships between these dose distributions and underlying characteristics of H...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/50/7/013
更新日期:2005-04-07 00:00:00
abstract::The purpose of this work was to characterize expert variation in segmentation of intracranial structures pertinent to radiation therapy, and to assess a registration-driven atlas-based segmentation algorithm in that context. Eight experts were recruited to segment the brainstem, optic chiasm, optic nerves, and eyes, o...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/14/021
更新日期:2011-07-21 00:00:00
abstract::A theoretical analysis and numerical solutions are presented for viscosity-dominated flow through a uniform, highly distensible tube with a slit-shaped cross section undergoing peristalsis. At flow rates below an intrinsic upper limit to the peristaltic carrying capacity of the tube, provided that there is always at l...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/32/7/002
更新日期:1987-07-01 00:00:00
abstract::A hybrid proportional-integral-in-time and cost-minimizing-in-space feedback control system for electromagnetic, deep regional hyperthermia is proposed. The unique features of this controller are that (1) it uses temperature, not specific absorption rate, as the criterion for selecting the relative phases and amplitud...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/48/5/306
更新日期:2003-03-07 00:00:00
abstract::The development of alpha-emitting radiopharmaceuticals using 211At requires quantitative determination of the time-dependent nature of the 211At biodistribution. However, imaging-based methods for acquiring this information with 211At have not found wide-spread use because of its low abundance of decay emissions suita...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aaaa95
更新日期:2018-02-21 00:00:00