Comparison of manual and automatic segmentation methods for brain structures in the presence of space-occupying lesions: a multi-expert study.

Abstract:

:The purpose of this work was to characterize expert variation in segmentation of intracranial structures pertinent to radiation therapy, and to assess a registration-driven atlas-based segmentation algorithm in that context. Eight experts were recruited to segment the brainstem, optic chiasm, optic nerves, and eyes, of 20 patients who underwent therapy for large space-occupying tumors. Performance variability was assessed through three geometric measures: volume, Dice similarity coefficient, and Euclidean distance. In addition, two simulated ground truth segmentations were calculated via the simultaneous truth and performance level estimation algorithm and a novel application of probability maps. The experts and automatic system were found to generate structures of similar volume, though the experts exhibited higher variation with respect to tubular structures. No difference was found between the mean Dice similarity coefficient (DSC) of the automatic and expert delineations as a group at a 5% significance level over all cases and organs. The larger structures of the brainstem and eyes exhibited mean DSC of approximately 0.8-0.9, whereas the tubular chiasm and nerves were lower, approximately 0.4-0.5. Similarly low DSCs have been reported previously without the context of several experts and patient volumes. This study, however, provides evidence that experts are similarly challenged. The average maximum distances (maximum inside, maximum outside) from a simulated ground truth ranged from (-4.3, +5.4) mm for the automatic system to (-3.9, +7.5) mm for the experts considered as a group. Over all the structures in a rank of true positive rates at a 2 mm threshold from the simulated ground truth, the automatic system ranked second of the nine raters. This work underscores the need for large scale studies utilizing statistically robust numbers of patients and experts in evaluating quality of automatic algorithms.

journal_name

Phys Med Biol

authors

Deeley MA,Chen A,Datteri R,Noble JH,Cmelak AJ,Donnelly EF,Malcolm AW,Moretti L,Jaboin J,Niermann K,Yang ES,Yu DS,Yei F,Koyama T,Ding GX,Dawant BM

doi

10.1088/0031-9155/56/14/021

subject

Has Abstract

pub_date

2011-07-21 00:00:00

pages

4557-77

issue

14

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(11)85448-5

journal_volume

56

pub_type

杂志文章
  • Impedance magnetocardiogram.

    abstract::We have developed an impedance magnetocardiogram (IMCG) system to detect the change of magnetic field corresponding to changes in blood volume in the heart. A low magnetic field from the electrical activity of the human heart--the so-called magnetocardiogram (MCG)--can be simultaneously detected by using this system. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/2/403

    authors: Kandori A,Miyashita T,Suzuki D,Yokosawa K,Tsukada K

    更新日期:2001-02-01 00:00:00

  • Pitch dependence of longitudinal sampling and aliasing effects in multi-slice helical computed tomography (CT).

    abstract::In this work, we investigate longitudinal sampling and aliasing effects in multi-slice helical CT. We demonstrate that longitudinal aliasing can be a significant, complicated, and potentially detrimental effect in multi-slice helical CT reconstructions. Multi-slice helical CT scans are generally undersampled longitudi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/15/318

    authors: La Rivière PJ,Pan X

    更新日期:2002-08-07 00:00:00

  • K x-ray fluorescence measurements of bone lead concentration: the analysis of low-level data.

    abstract::K line x-ray fluorescence (KXRF) measurements of bone lead have emerged as a promising new biological marker of internal lead dose in epidemiological studies. Some disagreements exist, however, over the analysis of data at low levels of bone lead concentration. In this study, we performed 30 serial measurements on eac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/9/007

    authors: Kim R,Aro A,Rotnitzky A,Amarasiriwardena C,Hu H

    更新日期:1995-09-01 00:00:00

  • Measuring the acoustoelectric interaction constant using ultrasound current source density imaging.

    abstract::Ultrasound current source density imaging (UCSDI) exploits the acoustoelectric (AE) effect, an interaction between ultrasound pressure and electrical resistivity, to map electrical conduction in the heart. The conversion efficiency for UCSDI is determined by the AE interaction constant K, a fundamental property of all...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/19/5929

    authors: Li Q,Olafsson R,Ingram P,Wang Z,Witte R

    更新日期:2012-10-07 00:00:00

  • Visually interpretable deep network for diagnosis of breast masses on mammograms.

    abstract::Recently, deep learning technology has achieved various successes in medical image analysis studies including computer-aided diagnosis (CADx). However, current CADx approaches based on deep learning have a limitation in interpreting diagnostic decisions. The limited interpretability is a major challenge for practical ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaef0a

    authors: Kim ST,Lee JH,Lee H,Ro YM

    更新日期:2018-12-04 00:00:00

  • A dedicated phantom design for positron emission mammography performance evaluation.

    abstract::A standard protocol for performance evaluation of positron emission mammography (PEM) systems has not yet been established. In this work we propose a methodology based on the design of specific phantoms for this imaging modality with component dimensions in accordance with typical breast lesion sizes together with the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aba7d1

    authors: Torres-Urzúa LF,Alva-Sanchez H,Martinez-Davalos A,García-Pérez FO,Peruyero-Rivas RM,Rodriguez-Villafuerte M

    更新日期:2020-07-21 00:00:00

  • The relevance of very low energy ions for heavy-ion therapy.

    abstract::Heavy-ion radiotherapy exploits the high biological effectiveness of localized energy deposition delivered by so-called Bragg-peak particles. Recent publications have challenged the established procedures to calculate biological effective dose distributions in treatment planning. They emphasize the importance of very ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/7/N03

    authors: Elsässer T,Gemmel A,Scholz M,Schardt D,Krämer M

    更新日期:2009-04-07 00:00:00

  • Self-adaptive ultrasonic beam amplifiers: application to transcostal shock wave therapy.

    abstract::Ultrasound shock wave therapy is increasingly used for non-invasive surgery. It requires the focusing of very high pressure amplitude in precisely controlled focal spots. In transcostal therapy of the heart or the liver, the high impedance mismatch between the bones and surrounding tissues gives rise to strong aberrat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad9b5

    authors: Robin J,Simon A,Arnal B,Tanter M,Pernot M

    更新日期:2018-09-06 00:00:00

  • Site-specific volumetric analysis of lung tumour motion.

    abstract::The treatment of lung cancer with radiation therapy is hindered by respiratory motion. Real-time adjustments to compensate for this motion are hampered by mechanical system latencies and imaging-rate restrictions. To better understand tumour motion behaviour for adaptive image-guided radiation therapy of lung cancer, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/12/005

    authors: Pepin EW,Wu H,Sandison GA,Langer M,Shirato H

    更新日期:2010-06-21 00:00:00

  • Convex reformulation of biologically-based multi-criteria intensity-modulated radiation therapy optimization including fractionation effects.

    abstract::Finding fluence maps for intensity-modulated radiation therapy (IMRT) can be formulated as a multi-criteria optimization problem for which Pareto optimal treatment plans exist. To account for the dose-per-fraction effect of fractionated IMRT, it is desirable to exploit radiobiological treatment plan evaluation criteri...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/22/006

    authors: Hoffmann AL,den Hertog D,Siem AY,Kaanders JH,Huizenga H

    更新日期:2008-11-21 00:00:00

  • GGEMS-Brachy: GPU GEant4-based Monte Carlo simulation for brachytherapy applications.

    abstract::In brachytherapy, plans are routinely calculated using the AAPM TG43 formalism which considers the patient as a simple water object. An accurate modeling of the physical processes considering patient heterogeneity using Monte Carlo simulation (MCS) methods is currently too time-consuming and computationally demanding ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/13/4987

    authors: Lemaréchal Y,Bert J,Falconnet C,Després P,Valeri A,Schick U,Pradier O,Garcia MP,Boussion N,Visvikis D

    更新日期:2015-07-07 00:00:00

  • Ultraviolet phototherapy: review of options for cabin dosimetry and operation.

    abstract::Ultraviolet (UV) treatment dose is determined by the length of time that a patient spends in a phototherapy cabin. The output from UV fluorescent lamps declines with use and a method is needed to compensate for the change in irradiance and to identify and replace any lamps that fail. The decline in lamp output with ag...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/2/008

    authors: Amatiello H,Martin CJ

    更新日期:2006-01-21 00:00:00

  • Positioning of a plane-parallel ionization chamber in clinical electron beams and the impact on perturbation factors.

    abstract::Current dosimetry protocols recommend the use of plane-parallel ionization chambers for the dosimetry of clinical electron beams. The necessary perturbation corrections p(wall) and p(cav) are assumed to be unity, independent of the depth of measurement and the energy of the primary electrons. To verify these assumptio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/8/011

    authors: Zink K,Wulff J

    更新日期:2009-04-21 00:00:00

  • Correlation between dosimetric effect and intrafraction motion during prostate treatments delivered with helical tomotherapy.

    abstract::The dosimetric impact of intrafraction prostate motion was investigated for helical tomotherapy treatments. Measured motion tracks were used to calculate the dosimetric impact on delivered target dose distributions. A dynamic dose calculation engine was developed to facilitate this evaluation. It was found that the D9...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/24/005

    authors: Langen KM,Lu W,Ngwa W,Willoughby TR,Chauhan B,Meeks SL,Kupelian PA,Olivera G

    更新日期:2008-12-21 00:00:00

  • Physical modelling of electroporation in close cell-to-cell proximity environments.

    abstract::Many applications of electroporation, especially those utilizing electrofusion and in-vivo electroporation, involve cell environments that include close cell-to-cell proximity and a wide range of target cell size. It is important to understand how this kind of environment may alter optimum electroporation electrical p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/12/012

    authors: Gaynor PT,Bodger PS

    更新日期:2006-06-21 00:00:00

  • Comparative efficiency of the multi-leaf collimator and variable-aperture collimator in intensity-modulated radiotherapy.

    abstract::The potential of the variable-aperture collimator (VAC) in intensity-modulated radiation therapy (IMRT) has been evaluated by comparing its performance with that of the multi-leaf collimator (MLC). This comparison used a decomposition algorithm to find the series of collimator segments that would treat a given intensi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/7/006

    authors: Anderson JW,Symonds-Tayler R,Hartmann G,Echner G,Lang C,Schlegel W,Webb S

    更新日期:2006-04-07 00:00:00

  • Dose uncertainty in radiotherapy of patients with head and neck cancer measured by in vivo ESR/alanine dosimetry using a mouthpiece.

    abstract::In order (i) to evaluate the dose uncertainty of the mouthpiece in daily use during intensity-modulated radiotherapy of patients with head and neck cancer, and (ii) to present a system for in vivo dosimetry of the oral mucosa, we equipped the mouthpiece with alanine dosimeter probes for in vivo dosimetry. The aim was ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/5/010

    authors: Wagner D,Anton M,Vorwerk H

    更新日期:2011-03-07 00:00:00

  • Specific absorbed fractions for a revised series of the UF/NCI pediatric reference phantoms: internal photon sources.

    abstract::Assessment of radiation absorbed dose to internal organs of the body from the intake of radionuclides or, in the medical setting through the injection of radiopharmaceuticals, is generally performed based upon reference biokinetic models or patient imaging data, respectively. Biokinetic models estimate the time course...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abc708

    authors: Schwarz BC,Godwin WJ,Wayson MB,Dewji SA,Jokisch DW,Lee C,Bolch WE

    更新日期:2020-11-03 00:00:00

  • Superpixel-based and boundary-sensitive convolutional neural network for automated liver segmentation.

    abstract::Segmentation of liver in abdominal computed tomography (CT) is an important step for radiation therapy planning of hepatocellular carcinoma. Practically, a fully automatic segmentation of liver remains challenging because of low soft tissue contrast between liver and its surrounding organs, and its highly deformable s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aabd19

    authors: Qin W,Wu J,Han F,Yuan Y,Zhao W,Ibragimov B,Gu J,Xing L

    更新日期:2018-05-04 00:00:00

  • Monitoring the irradiation field of 12C and 16O SOBP beams using positron emitters produced through projectile fragmentation reactions.

    abstract::In order to effectively utilize the prominent properties of heavy ions in radiotherapy, it is important to evaluate both the position of the field irradiated with incident ions and the absorbed dose distribution in a patient's body. One of the methods for this purpose is the utilization of the positron emitters produc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/3/002

    authors: Inaniwa T,Kohno T,Tomitani T,Sato S

    更新日期:2008-02-07 00:00:00

  • Experimental validation of Monte Carlo calculations with a voxelized Rando-Alderson phantom: a study on influence parameters.

    abstract::The development and improvement of techniques for an accurate dose assessment in medical physics is an important task. In this study, we focus on the validation of Monte Carlo calculations, by comparing organ doses assessed experimentally with thermoluminescent detectors in the Rando-Alderson phantom with doses calcul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/20/018

    authors: Struelens L,Vanhavere F,Smans K

    更新日期:2008-10-21 00:00:00

  • Effect of fiducial marker localization on stereotactic target coordinate calculation in CT slices and radiographs.

    abstract::Novel methods are presented which allow the estimation of the effect of stereotactic fiducial marker localization on target localization in a stereotactic surgery planning program based on the integration of image data from various modalities. The results of simulations are presented. A method for the evaluation of th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/11/008

    authors: Lemieux L,Jagoe R

    更新日期:1994-11-01 00:00:00

  • Automated prostate segmentation in whole-body MRI scans for epidemiological studies.

    abstract::The whole prostatic volume (PV) is an important indicator for benign prostate hyperplasia. Correlating the PV with other clinical parameters in a population-based prospective cohort study (SHIP-2) requires valid prostate segmentation in a large number of whole-body MRI scans. The axial proton density fast spin echo fa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/17/5899

    authors: Habes M,Schiller T,Rosenberg C,Burchardt M,Hoffmann W

    更新日期:2013-09-07 00:00:00

  • Glandular dose in breast computed tomography with synchrotron radiation.

    abstract::The purpose of this work is to provide an evaluation of the mean glandular dose (MGD) for breast computed tomography (CT) with synchrotron radiation in an axial scanning configuration with a partial or total organ volume irradiation, for the in vivo program of breast CT ongoing at the ELETTRA facility (Trieste, Italy)...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/2/569

    authors: Mettivier G,Fedon C,Di Lillo F,Longo R,Sarno A,Tromba G,Russo P

    更新日期:2016-01-21 00:00:00

  • Automated sonographic evaluation of testicular perfusion.

    abstract::Contrast-enhanced ultrasound (US) imaging is potentially applicable to the investigation of vascular disorders of the testis. We investigated the ability of two automated computer algorithms to analyse contrast-enhanced pulse inversion US data in a rabbit model of unilateral testicular ischaemia and to correctly deter...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/14/010

    authors: Thierman JS,Clement GT,Kalish LA,O'Kane PL,Frauscher F,Paltiel HJ

    更新日期:2006-07-21 00:00:00

  • Comparison between TG-51 and TRS-398: electron contamination effect on photon beam-quality specification.

    abstract::Two dosimetry protocols based on absorbed dose to water have recently been implemented: TG-51 and TRS-398. These protocols use different beam-quality indices: %dd(10)x and TPR20,10. The effect of electron contamination in measurements of %dd(10)x has been proposed as a disadvantage of the TG-51. For actual measurement...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/1/002

    authors: Lopez Medina A,Teijeiro A,Salvador F,Medal D,Vazquez J,Salgado M,Carrion MC

    更新日期:2004-01-07 00:00:00

  • Ionization quenching in scintillators used for dosimetry of mixed particle fields.

    abstract::Ionization quenching in ion beam dosimetry is often related to the fluence- or dose-averaged linear energy transfer (LET). Both quantities are however averaged over a wide LET range and a mixed field of primary and secondary ions. We propose a novel method to correct the quenched luminescence in scintillators exposed ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab12f2

    authors: Christensen JB,Almhagen E,Stolarczyk L,Vestergaard A,Bassler N,Andersen CE

    更新日期:2019-04-29 00:00:00

  • Threshold-driven optimization for reference-based auto-planning.

    abstract::We study threshold-driven optimization methodology for automatically generating a treatment plan that is motivated by a reference DVH for IMRT treatment planning. We present a framework for threshold-driven optimization for reference-based auto-planning (TORA). Commonly used voxel-based quadratic penalties have two co...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa731

    authors: Long T,Chen M,Jiang S,Lu W

    更新日期:2018-02-08 00:00:00

  • Assessment of histotripsy-induced liquefaction with diagnostic ultrasound and magnetic resonance imaging in vitro and ex vivo.

    abstract::Histotripsy is a therapeutic ultrasound modality under development to liquefy tissue mechanically via bubble clouds. Image guidance of histotripsy requires both quantification of the bubble cloud activity and accurate delineation of the treatment zone. In this study, magnetic resonance (MR) and diagnostic ultrasound i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab143f

    authors: Anthony GJ,Bollen V,Hendley S,Antic T,Sammet S,Bader KB

    更新日期:2019-05-02 00:00:00

  • The integration of DVH-based planning aspects into a convex intensity modulated radiation therapy optimization framework.

    abstract::The formulation of intensity modulated radiation therapy (IMRT) planning aspects frequently uses the dose-volume histogram (DVH), whereas plan computations often happen in the more desirable convex IMRT optimization framework. Inspired by a recent publication of Zinchenko et al (2008 Phys. Med. Biol. 53 3231-50), this...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/12/N02

    authors: Kratt K,Scherrer A

    更新日期:2009-06-21 00:00:00