Abstract:
:Segmentation of liver in abdominal computed tomography (CT) is an important step for radiation therapy planning of hepatocellular carcinoma. Practically, a fully automatic segmentation of liver remains challenging because of low soft tissue contrast between liver and its surrounding organs, and its highly deformable shape. The purpose of this work is to develop a novel superpixel-based and boundary sensitive convolutional neural network (SBBS-CNN) pipeline for automated liver segmentation. The entire CT images were first partitioned into superpixel regions, where nearby pixels with similar CT number were aggregated. Secondly, we converted the conventional binary segmentation into a multinomial classification by labeling the superpixels into three classes: interior liver, liver boundary, and non-liver background. By doing this, the boundary region of the liver was explicitly identified and highlighted for the subsequent classification. Thirdly, we computed an entropy-based saliency map for each CT volume, and leveraged this map to guide the sampling of image patches over the superpixels. In this way, more patches were extracted from informative regions (e.g. the liver boundary with irregular changes) and fewer patches were extracted from homogeneous regions. Finally, deep CNN pipeline was built and trained to predict the probability map of the liver boundary. We tested the proposed algorithm in a cohort of 100 patients. With 10-fold cross validation, the SBBS-CNN achieved mean Dice similarity coefficients of 97.31 ± 0.36% and average symmetric surface distance of 1.77 ± 0.49 mm. Moreover, it showed superior performance in comparison with state-of-art methods, including U-Net, pixel-based CNN, active contour, level-sets and graph-cut algorithms. SBBS-CNN provides an accurate and effective tool for automated liver segmentation. It is also envisioned that the proposed framework is directly applicable in other medical image segmentation scenarios.
journal_name
Phys Med Bioljournal_title
Physics in medicine and biologyauthors
Qin W,Wu J,Han F,Yuan Y,Zhao W,Ibragimov B,Gu J,Xing Ldoi
10.1088/1361-6560/aabd19subject
Has Abstractpub_date
2018-05-04 00:00:00pages
095017issue
9eissn
0031-9155issn
1361-6560journal_volume
63pub_type
杂志文章abstract::Remission spectroscopy in living tissues can only be performed because scattering processes induce a pronounced amount of backscattered light. New types of scattering chambers were constructed in order to investigate the angular distribution of light intensities caused by scattering events typical for living tissues. ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/34/12/012
更新日期:1989-12-01 00:00:00
abstract::Radiotherapy calculations often involve complex geometries such as interfaces between materials of vastly differing atomic number, such as lung, bone and/or air interfaces. Monte Carlo methods have been used to calculate accurately the perturbation effects of the interfaces. However, these methods can be computational...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/51/9/010
更新日期:2006-05-07 00:00:00
abstract::Two experimental investigations of the electromagnetic method to measure body composition are presented. In the first experiment, the impedance of a single-loop transmitting antenna, located at the centre of a 150 m helical receiving coil, was observed to have a sharp minimum at 2.40 MHz. The impedance of the antenna ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/40/4/011
更新日期:1995-04-01 00:00:00
abstract::The purpose of this study is the analysis of the influence of anisotropic conductivity on magnetic fields and electric potentials by means of phantom measurements. An artificial rotating current dipole was placed in the middle of an anisotropic skein arrangement in a torso phantom filled with saline solution. The sign...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/1/017
更新日期:2008-01-07 00:00:00
abstract::Energy and angular distributions of electron beams with different energies were simulated by Monte Carlo calculations. These beams were generated by the NOVAC7 system (Hitesys, Italy), a mobile electron accelerator specifically dedicated to intra-operative radiation therapy (IORT). The electron beam simulations were v...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/20/008
更新日期:2007-10-21 00:00:00
abstract::Exploiting the field response of magnetic tracers, magnetic particle imaging (MPI) allows direct, local quantification of the tracer concentration in bulk structures. Here, we investigated the use of characteristic field response functions to spatially resolve the absolute concentration of multiple nanoparticle specie...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/21/6521
更新日期:2014-11-07 00:00:00
abstract::For angiography using synchrotron radiation we measured the absorbed dose distribution in inhomogeneous phantoms with thin LiF:Mg, Cu, P, LiF:Mg, Ti thermoluminescent dosimeters (TLDs) in tissue and lung substitutes, and with Mg2SiO4:Tb TLDs in bone substitute for 33.32 keV monoenergetic photons from synchrotron radia...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/46/3/308
更新日期:2001-03-01 00:00:00
abstract::The effects of radiation damage, tumour repopulation and cell sublethal damage repair and the possibility of extracting information about the model parameters describing them are investigated in this work. Previously published data on two different cultured cell lines were analysed with the help of a tumour control pr...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/50/13/006
更新日期:2005-07-07 00:00:00
abstract::Several direct algorithms have been proposed to take into account the non-linear path of protons in the reconstruction of a proton CT (pCT) image. This paper presents a comparison between five of them, in terms of spatial resolution and relative stopping power (RSP) accuracy. Our comparison includes (1) a distance-dri...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab7d53
更新日期:2020-06-01 00:00:00
abstract::Irradiation of moving targets using a scanned ion beam can cause clinically intolerable under- and overdosages within the target volume due to the interplay effect. Several motion mitigation techniques such as gating, beam tracking and rescanning are currently investigated to overcome this restriction. To enable detai...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/8/2235
更新日期:2012-04-21 00:00:00
abstract::We experimentally investigated the SPECT recovery of I-131 activity in multiple spheres located simultaneously at different locations within a cylindrical phantom that had an elliptical cross section. The sphere volumes ranged from 209 cc down to 4.2 cc. A Prism 3000 camera and two types of parallel-hexagonal-hole col...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/3/017
更新日期:2007-02-07 00:00:00
abstract::Methods based on magnetic resonance imaging for the measurement of three-dimensional distributions of radiation dose are highly developed. However, relatively little work has been done on optical computed tomography (OCT). This paper describes a new OCT scanner based on a broad beam light source and a two-dimensional ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/46/12/309
更新日期:2001-12-01 00:00:00
abstract::Range verification is one of the most relevant tasks in ion beam therapy. In the case of carbon ion therapy, positron emission tomography (PET) is the most widely used method for this purpose, which images the [Formula: see text]-activation following nuclear interactions of the ions with the tissue nuclei. Since the p...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab17f9
更新日期:2019-05-21 00:00:00
abstract::A cost-effective method employing polysulphone, nalidixic acid, 8-methoxypsoralen and phenothiazine as UV dosimeters is presented for evaluating the UV spectrum. The exposure measured by each dosimeter is a function of the source spectrum and the spectral response of the material. Each material has a different spectra...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/42/1/005
更新日期:1997-01-01 00:00:00
abstract::For image-guided radiotherapy (IGRT) systems based on cone beam CT (CBCT) integrated into a linear accelerator, the reproducible alignment of imager to x-ray source is critical to the registration of both the x-ray-volumetric image with the megavoltage (MV) beam isocentre and image sharpness. An enhanced method of det...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/19/002
更新日期:2008-10-07 00:00:00
abstract::This study presents the first observation of shear waves induced remotely within soft tissues. It was performed through the combination of a transcranial magnetic stimulation device and a permanent magnet. A physical model based on Maxwell and Navier equations was developed. Experiments were performed on a cryogel pha...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/61/6/2582
更新日期:2016-03-21 00:00:00
abstract::Coincidence resolving time (CRT) is one of the most important physical-performance measures for positron emission tomography (PET), as reconstruction with accurate time-of-flight information enhances the lesion detectability in patient studies. Accordingly, various PET detector designs and high-performance front-end r...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aaf0bb
更新日期:2018-12-10 00:00:00
abstract::To evaluate a commercial synthetic CT (syn-CT) software for use in prostate radiotherapy. Twenty-five prostate patients underwent CT and MR simulation scans in treatment position on a 3T MR scanner. A commercially available MR protocol was used that included a T2w turbo spin-echo sequence for soft-tissue contrast and ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa5452
更新日期:2017-04-21 00:00:00
abstract::In carbon-ion radiotherapy, single-beam delivery each day in alternate directions has been common practice for efficient operation, taking advantage of the Bragg peak and the relative biological effectiveness (RBE) for uniform dose conformation to a tumor. Treatments are usually fractionated and treatment plans are ev...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/62/3/1062
更新日期:2017-02-07 00:00:00
abstract::Finite element (FE) modeling provides a useful tool to understand the mechanical behavior of complex tissues, such as cancers, in a variety of testing conditions. Although a number of numerical and analytical models for cancerous tumors are retrievable in the literature, none of these models is capable of completely d...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aae572
更新日期:2018-10-24 00:00:00
abstract::In this paper, we present simulation studies for the second-generation MRI compatible SPECT system, MRC-SPECT-II, based on an inverted compound eye (ICE) gamma camera concept. The MRC-SPECT-II system consists of a total of 1536 independent micro-pinhole-camera-elements (MCEs) distributed in a ring with an inner diamet...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aaa4fb
更新日期:2018-02-12 00:00:00
abstract::A Geiger-mode avalanche photodiode (Si-PM) is a promising photodetector for PET, especially for use in a magnetic resonance imaging (MRI) system, because it has high gain and is less sensitive to a static magnetic field. We developed a Si-PM-based depth-of-interaction (DOI) PET system for small animals. Hamamatsu 4 × ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/19/013
更新日期:2010-10-07 00:00:00
abstract::Magnetic Particle Imaging (MPI) is a novel technology, which opens new possibilities for promising biomedical applications. MPI uses magnetic fields to generate a specific response from magnetic nanoparticles (MNPs), to determine their spatial location non-invasively and without using ionizing radiation. One open chal...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/abc364
更新日期:2020-10-21 00:00:00
abstract::Abdominal organ motion may lead to considerable uncertainties in pencil-beam scanning (PBS) proton therapy of pancreatic cancer. Beam gating, where irradiation only occurs in certain breathing phases in which the gating conditions are fulfilled, may be an option to reduce the interplay effect between tumor motion and ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab1175
更新日期:2019-04-10 00:00:00
abstract::Fractional flow reserve (FFR) provides an objective physiological evaluation of stenosis severity. A technique that can measure FFR using only angiographic images would be a valuable tool in the cardiac catheterization laboratory. To perform this, the diseased blood flow can be measured with a first pass distribution ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/14/017
更新日期:2008-07-21 00:00:00
abstract::The quality of radiation therapy delivered for treating cancer patients is related to set-up errors and organ motion. Due to the margins needed to ensure adequate target coverage, many breast cancer patients have been shown to develop late side effects such as pneumonitis and cardiac damage. Breathing-adapted radiatio...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/50/19/020
更新日期:2005-10-07 00:00:00
abstract::Blood was withdrawn from the ante-cubital vein of five normal volunteers and the erythrocytes were washed and resuspended in isotonic saline. The rate of descent of the erythrocyte-saline boundary was measured every hour for a period of at least 4 h for different suspended cell concentrations. The velocity of this bou...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/30/2/002
更新日期:1985-02-01 00:00:00
abstract::A method for extracting the dark-field signal in propagation-based phase-contrast imaging is proposed. In the case of objects consisting predominantly of a single material, or several different materials with similar ratios of the real decrement to the imaginary part of the complex refractive index, the proposed metho...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/abac9d
更新日期:2020-11-17 00:00:00
abstract::The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial "tumours" were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the "tumours" were impl...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/1/007
更新日期:2007-01-07 00:00:00
abstract::Elastography, which uses ultrasound to image the tissue strain that results from an applied displacement, can display tumours and heat-ablated tissue with high contrast. However, its application to liver in vivo may be problematic due to the presence of respiratory and cardiovascular sources of displacement. The aim o...
journal_title:Physics in medicine and biology
pub_type: 临床试验,杂志文章
doi:10.1088/0031-9155/49/18/001
更新日期:2004-09-21 00:00:00