Abstract:
:Current dosimetry protocols recommend the use of plane-parallel ionization chambers for the dosimetry of clinical electron beams. The necessary perturbation corrections p(wall) and p(cav) are assumed to be unity, independent of the depth of measurement and the energy of the primary electrons. To verify these assumptions detailed Monte Carlo studies of a Roos chamber in clinical electron beams with energies in the range of 6-21 MeV are performed at different depths in water and analyzed in terms of Spencer-Attix cavity theory. Separate simulations for the perturbation corrections p(wall) and p(cav) indicate quite different properties of both correction factors with depth. Dose as well as fluence calculations show a nearly depth-independent wall correction factor for a shift of the Roos chamber Deltaz = -0.017 cm toward the focus. This value is in good agreement with the positioning recommendation given in all dosimetry protocols. Regarding the fluence perturbation p(cav) the simulation of the electron fluence inside the air cavity in comparison to water unambiguously reveals an in-scattering of low energy electrons, despite the fact, that the cavity is 'well guarded'. For depths beyond the reference depth z(ref) this effect is superimposed by an increased loss of primary electrons from the beam resulting in p(cav) > 1. This effect is largest for low electron energies but present for all electron energies involved in this study. Based on the different depth dependences of p(wall) and p(cav) it is possible to choose a chamber shift Deltaz in a way to minimize the depth dependence of the overall perturbation factor p. For the Roos chamber this shift is Deltaz = -0.04 cm independent of electron energy.
journal_name
Phys Med Bioljournal_title
Physics in medicine and biologyauthors
Zink K,Wulff Jdoi
10.1088/0031-9155/54/8/011subject
Has Abstractpub_date
2009-04-21 00:00:00pages
2421-35issue
8eissn
0031-9155issn
1361-6560pii
S0031-9155(09)90534-6journal_volume
54pub_type
杂志文章abstract::Does the posture of a patient have an effect on the organ and tissue absorbed doses caused by x-ray examinations? This study aims to find the answer to this question, based on Monte Carlo (MC) simulations of commonly performed x-ray examinations using adult phantoms modelled to represent humans in standing as well as ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/15/014
更新日期:2010-08-07 00:00:00
abstract::Recently, there has been an increased interest in flattening-filter-free (FFF) linear accelerators. Removal of the filter results in available dose rates up to 24 Gy min(-1) (for nominal energy 10 MV in depth of maximum dose, a source-surface distance of 100 cm and a field size of 10×10 cm2). To guarantee accurate rel...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/9/2819
更新日期:2012-05-07 00:00:00
abstract::A technique is described for examining the mode of operation of radiation detectors and estimating the losses and gains caused by random summing effects in spectra acquired at high counting rates. The technique is applied to estimating the errors caused by random summing when measuring the amounts of carbon and nitrog...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/34/8/010
更新日期:1989-08-01 00:00:00
abstract::Dynamic radiation therapy techniques require that the treatment head setup varies in time and space during dose delivery. Examples are leaf motion in intensity modulated x-ray therapy, modulator wheel rotation in conventional proton therapy and variable magnet settings in proton beam scanning. Consequently, for Monte ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/49/6/n03
更新日期:2004-03-21 00:00:00
abstract::Compressed sensing (CS) aims to recover images from fewer measurements than that governed by the Nyquist sampling theorem. Most CS methods use analytical predefined sparsifying domains such as total variation, wavelets, curvelets, and finite transforms to perform this task. In this study, we evaluated the use of dicti...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/15/5853
更新日期:2015-08-07 00:00:00
abstract::Ankylosing spondylitis is a disease characterized by abnormal bone formation (syndesmophyte) at the margins of inter-vertebral disc spaces. Syndesmophyte growth is currently typically monitored by the visual inspection of radiographs. The limitations inherent to the modality (2D projection of a 3D object) and rater (q...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/14/4683
更新日期:2012-07-21 00:00:00
abstract::The 'EXACT3D' positron tomograph, which is now in routine clinical research use, was developed with the aim of achieving unprecedented sensitivity, high spatial and temporal resolution and simplicity of design using proven detector technology. It consists of six rings of standard detector blocks (CTI/Siemens EXACT HR+...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/45/9/313
更新日期:2000-09-01 00:00:00
abstract::This paper presents a computerized method for the selection of an irregular region of interest (ROI) in broadband ultrasound attenuation (BUA) images. A region growing algorithm searches an initial region in the posterior part of the calcaneus until the pixel with the lowest attenuation value is found; this is the sta...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/47/2/310
更新日期:2002-01-21 00:00:00
abstract::Sparse phased array ultrasound transducers with millimetre length scale elements have previously been proposed for generating hyperthermia but not for imaging. Numerical simulation with a pseudospectral solver was used to investigate: (a) how the position of the maximum pressure in the focal region changed with elemen...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aace07
更新日期:2018-07-16 00:00:00
abstract::Online proton range/dose verification based on measurements of proton-induced positron emitters is a promising strategy for quality assurance in proton therapy. Because of the nonlinear correlation between the dose distribution and the activity distribution of positron emitters, we aim to establish their relationship ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab3564
更新日期:2019-09-04 00:00:00
abstract::Range verification is one of the most relevant tasks in ion beam therapy. In the case of carbon ion therapy, positron emission tomography (PET) is the most widely used method for this purpose, which images the [Formula: see text]-activation following nuclear interactions of the ions with the tissue nuclei. Since the p...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab17f9
更新日期:2019-05-21 00:00:00
abstract::A transformation method was investigated for applying the MIRD absorbed fraction to internal dose calculations for an individual. The transformation method consists of two parts, transformation of the target organ mass, and of the distance between source and target organs. The variation of the specific absorbed fracti...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/20/4/006
更新日期:1975-07-01 00:00:00
abstract::This paper evaluates the performance of two large-area position-sensitive solid-state photomultipliers (PS-SSPM) for use in small animal PET detector designs. Both PS-SSPM device designs are 1 cm² in area, the first being a 2 × 2 tiled array of 5 mm × 5 mm PS-SSPMs and the second being a 10 mm × 10 mm continuous PS-SS...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/24/8119
更新日期:2012-12-21 00:00:00
abstract::In this work, we investigate longitudinal sampling and aliasing effects in multi-slice helical CT. We demonstrate that longitudinal aliasing can be a significant, complicated, and potentially detrimental effect in multi-slice helical CT reconstructions. Multi-slice helical CT scans are generally undersampled longitudi...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/47/15/318
更新日期:2002-08-07 00:00:00
abstract::Tumour histological grade has prognostic implications in breast cancer. Tumour features in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and T2-weighted (T2W) imaging can provide related and complementary information in the analysis of breast lesions to improve MRI-based histological status prediction...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab3fd3
更新日期:2019-10-23 00:00:00
abstract::The goals of this study were (1) to characterize the optical artefacts affecting measurement accuracy in a volumetric liquid scintillator detector, and (2) to develop methods to correct for these artefacts. The optical artefacts addressed were photon scattering, refraction, camera perspective, vignetting, lens distort...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/1/23
更新日期:2014-01-06 00:00:00
abstract::Using Cherenkov radiation in positron emission tomography (PET) has the potential to improve the time of flight (TOF) resolution and reduce the cost of detectors. In previous studies promising TOF results were achieved when lead fluoride (PbF2) crystals were used instead of a scintillator. In this work, a whole-body P...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab6f97
更新日期:2020-03-06 00:00:00
abstract::The reference levels for testing compliance of human exposure with radio-frequency (RF) safety limits have been derived from very simplified models of the human. In order to validate these findings for anatomical models, we investigated the absorption characteristics for various anatomies ranging from 6 year old child...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/4/004
更新日期:2009-02-21 00:00:00
abstract::Experimental radiobiological investigations of fast neutron beams involve irradiation of thin cell layers. The irradiation of cells is done either in free air or with a material such as graphite, TE plastic or bone-equivalent plastic covering the cells. This paper discusses the computed dose distributions in LET at sh...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/24/5/007
更新日期:1979-09-01 00:00:00
abstract::W (the average energy to form an ion pair) for 5.4 MeV 241Am alpha particles in a Rossi-type tissue-equivalent (TE) gas, argon and methane was determined to an accuracy better than 0.2% using a new automated data handling system. A vibrating reed electrometer and current digitiser were used to measure the current prod...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/24/2/005
更新日期:1979-03-01 00:00:00
abstract::This paper presents a compressed sensing (CS)-inspired reconstruction method for limited-angle computed tomography (CT). Currently, CS-inspired CT reconstructions are often performed by minimizing the total variation (TV) of a CT image subject to data consistency. A key to obtaining high image quality is to optimize t...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/7/2119
更新日期:2013-04-07 00:00:00
abstract::Recent measurements of differential elastic and inelastic neutron scattering from oxygen, nitrogen and calcium at 18 less than En less than 26 MeV are presented and analysed in terms of the optical model. These data, together with earlier measurements of scattering and total cross sections, are used to construct model...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/33/3/001
更新日期:1988-03-01 00:00:00
abstract::During image-guided cancer radiation treatment, three-dimensional (3D) tumor volumetric information is important for treatment success. However, it is typically not feasible to image a patient's 3D tumor continuously in real time during treatment due to concern over excessive patient radiation dose. We present a new i...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa56b2
更新日期:2017-02-21 00:00:00
abstract::This paper describes an accurate and time-efficient method for the determination of total body potassium via a combination of measurements in the Birmingham whole body counter and the use of the Monte Carlo n-particle (MCNP) simulation code. In developing this method, MCNP has also been used to derive values for some ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/51/17/009
更新日期:2006-09-07 00:00:00
abstract::Monte Carlo calculations of the energy response of LiF dosemeters have been carried out to help resolve the discrepancy between the measurements of Holt, Edelstein and Clark (1975) and those of Paliwal and Almond (1975) and others. It is concluded that the assumptions used by Holt et al. are largely responsible. They ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/22/5/003
更新日期:1977-09-01 00:00:00
abstract::Delivery of pencil beam scanning (PBS) requires the on-line measurement of several beam parameters. If the measurement is outside of specified tolerances and a binary threshold algorithm is used, the beam will be paused. Given instrumentation and statistical noise such a system can lead to many pauses which could incr...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/61/1/400
更新日期:2016-01-07 00:00:00
abstract::In recent years, particle therapy has become a widely accepted form of cancer treatment and technological advances in beam delivery technology (i.e. pencil beam scanning (PBS)) have enabled the application of highly conformal dose distributions to static targets. Current research focuses on the possibilities for the t...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/22/7905
更新日期:2013-11-21 00:00:00
abstract::The combined build-up and attenuation factor, B exp (-mu r), of point isotropic photon sources in a water medium has been calculated using the Monte Carlo method, for energies (20-1500 keV) and distances (1-10 cm) relevant in brachytherapy. For the transport of photons and electrons, up-to-date and self-consistent tot...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/36/6/005
更新日期:1991-06-01 00:00:00
abstract::A method for quantifying the tissue sodium concentration (TSC) in the rat brain from ²³Na-MR images was developed. TSC is known to change in a variety of common human diseases and holds considerable potential to contribute to their study; however, its accurate measurement in small laboratory animals has been hindered ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/24/019
更新日期:2010-12-21 00:00:00
abstract::Measurements of lung nodule volume with multi-detector computed tomography (MDCT) have been shown to be more accurate and precise compared to conventional lower dimensional measurements. Quantifying the size of lesions is potentially more difficult when the object-to-background contrast is low as with lesions in the l...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/2/671
更新日期:2015-01-21 00:00:00