The transformation method for the MIRD absorbed fraction as applied to various physiques.

Abstract:

:A transformation method was investigated for applying the MIRD absorbed fraction to internal dose calculations for an individual. The transformation method consists of two parts, transformation of the target organ mass, and of the distance between source and target organs. The variation of the specific absorbed fraction with distance in the human body was approximated with the traditional exponential form. To examine the transformation method, experiments were carried out for cobalt-60 gamma rays, using LiF-TLD, with the thyroid and ovaries as source organs. The transformed values of the MIRD absorbed fractions agreed well with the experimental values. Some results obtained from the MIRD values by these transformation methods were also compared with those for younger age groups calculated by Snyder.

journal_name

Phys Med Biol

authors

Yamaguchi H,Kato Y,Shiragai A

doi

10.1088/0031-9155/20/4/006

subject

Has Abstract

pub_date

1975-07-01 00:00:00

pages

593-601

issue

4

eissn

0031-9155

issn

1361-6560

journal_volume

20

pub_type

杂志文章
  • Mass-energy absorption coefficient and backscatter factor ratios for kilovoltage x-ray beams.

    abstract::For low-energy (up to 150 kV) x-rays, the ratio of mass-energy absorption coefficients for water to air, (mu(en)/rho)w.air, and the backscatter factor B are used in the conversion of air kerma, measured free-in-air, to water kerma on the surface of a water phantom. For clinical radiotherapy, similar conversion factors...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/1/011

    authors: Ma CM,Seuntjens JP

    更新日期:1999-01-01 00:00:00

  • Lateral variations of radiobiological properties of therapeutic fields of 1H, 4He, 12C and 16O ions studied with Geant4 and microdosimetric kinetic model.

    abstract::As known, in cancer therapy with ion beams the relative biological effectiveness (RBE) of ions changes in the course of their propagation in tissues. Such changes are caused not only by increasing the linear energy transfer (LET) of beam particles with the penetration depth towards the Bragg peak, but also by nuclear ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa75b2

    authors: Dewey S,Burigo L,Pshenichnov I,Mishustin I,Bleicher M

    更新日期:2017-06-27 00:00:00

  • Image domain multi-material decomposition using single energy CT.

    abstract::Multi-material decomposition (MMD) technique decomposes the CT images into basis material images and has been promising in clinical practice for material composition quantification within the human body. MMD could be implemented using the image data acquired from spectral CT or its special case, dual-energy CT (DECT) ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab7503

    authors: Xue Y,Luo C,Jiang Y,Yang P,Hu X,Zhou Q,Wang J,Hu X,Sheng K,Niu T

    更新日期:2020-03-23 00:00:00

  • The ArcCHECK diode array for dosimetric verification of HybridArc.

    abstract::The aim of this work is to evaluate dosimetric accuracy of a new treatment modality, HybridArc, in iPlan RT Dose 4.5 (BrainLAB, Feldkirchen, Germany) using a four-dimensional diode array (ArcCHECK, Sun Nuclear Corporation, Melbourne, USA). HybridArc is able to enhance dynamic conformal arcs with inversely planned elem...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/16/021

    authors: Petoukhova AL,van Egmond J,Eenink MG,Wiggenraad RG,van Santvoort JP

    更新日期:2011-08-21 00:00:00

  • Simulated lesion, human observer performance comparison between thin-section dedicated breast CT images versus computed thick-section simulated projection images of the breast.

    abstract::The objective of this study was to compare the lesion detection performance of human observers between thin-section computed tomography images of the breast, with thick-section (>40 mm) simulated projection images of the breast. Three radiologists and six physicists each executed a two alterative force choice (2AFC) s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/8/3347

    authors: Chen L,Boone JM,Abbey CK,Hargreaves J,Bateni C,Lindfors KK,Yang K,Nosratieh A,Hernandez A,Gazi P

    更新日期:2015-04-21 00:00:00

  • Dosimetric and workflow evaluation of first commercial synthetic CT software for clinical use in pelvis.

    abstract::To evaluate a commercial synthetic CT (syn-CT) software for use in prostate radiotherapy. Twenty-five prostate patients underwent CT and MR simulation scans in treatment position on a 3T MR scanner. A commercially available MR protocol was used that included a T2w turbo spin-echo sequence for soft-tissue contrast and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5452

    authors: Tyagi N,Fontenla S,Zhang J,Cloutier M,Kadbi M,Mechalakos J,Zelefsky M,Deasy J,Hunt M

    更新日期:2017-04-21 00:00:00

  • Dual energy CT using slow kVp switching acquisition and prior image constrained compressed sensing.

    abstract::Dual energy computed tomography (DECT) is currently a subject of extensive investigation. DECT is currently implemented using either a dual source scanner with high and low kVp data acquired from separate sources or a single source scanner with both high and low kVp data acquired in an alternating manner. Both methods...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/21/005

    authors: Szczykutowicz TP,Chen GH

    更新日期:2010-11-07 00:00:00

  • Calculation of absorbed dose distributions from dynamic wedges.

    abstract::In radiotherapy with photon beams, the use of dynamic wedges, which are obtained by the movement of one of the jaws, offers an increasing flexibility relative to the traditional use of metal wedges. But it is a disadvantage for the measurement of absorbed dose distributions, because the absorbed dose at each measureme...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/6/009

    authors: Storchi P,Woudstra E,Verlinde P,Johansson KA,Samuelsson A

    更新日期:1998-06-01 00:00:00

  • SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubes.

    abstract::A software program, SpekCalc, is presented for the calculation of x-ray spectra from tungsten anode x-ray tubes. SpekCalc was designed primarily for use in a medical physics context, for both research and education purposes, but may also be of interest to those working with x-ray tubes in industry. Noteworthy is the p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/19/N01

    authors: Poludniowski G,Landry G,DeBlois F,Evans PM,Verhaegen F

    更新日期:2009-10-07 00:00:00

  • Modelling infrared temperature measurements: implications for laser irradiation and cryogen cooling studies.

    abstract::The use of thermographic techniques has increased as infrared detector technology has evolved and improved. For laser-tissue interactions, thermal cameras have been used to monitor the thermal response of tissue to pulsed and continuous wave irradiation. It is important to note that the temperature indicated by the th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/2/319

    authors: Choi B,Pearce JA,Welch AJ

    更新日期:2000-02-01 00:00:00

  • Rank-shaping regularization of exponential spectral analysis for application to functional parametric mapping.

    abstract::Compartmental models are widely used for the mathematical modelling of dynamic studies acquired with positron emission tomography (PET). The numerical problem involves the estimation of a sum of decaying real exponentials convolved with an input function. In exponential spectral analysis (SA), the nonlinear estimation...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/23/002

    authors: Turkheimer FE,Hinz R,Gunn RN,Aston JA,Gunn SR,Cunningham VJ

    更新日期:2003-12-07 00:00:00

  • SAR calculations in an anatomically realistic model of the head for mobile communication transceivers at 900 MHz and 1.8 GHz.

    abstract::A new mathematical model of the head has been constructed from a set of serial MRI slices from one subject. Finite-difference time-domain (FDTD) calculations of the specific energy absorption rate (SAR) have been performed on this model with a 2 mm resolution for a generic mobile communication transceiver represented ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/10/003

    authors: Dimbylow PJ,Mann SM

    更新日期:1994-10-01 00:00:00

  • Evaluation of the reproducibility of lung motion probability distribution function (PDF) using dynamic MRI.

    abstract::Treatment planning based on probability distribution function (PDF) of patient geometries has been shown a potential off-line strategy to incorporate organ motion, but the application of such approach highly depends upon the reproducibility of the PDF. In this paper, we investigated the dependences of the PDF reproduc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/2/004

    authors: Cai J,Read PW,Altes TA,Molloy JA,Brookeman JR,Sheng K

    更新日期:2007-01-21 00:00:00

  • Block matching 3D random noise filtering for absorption optical projection tomography.

    abstract::Absorption and emission optical projection tomography (OPT), alternatively referred to as optical computed tomography (optical-CT) and optical-emission computed tomography (optical-ECT), are recently developed three-dimensional imaging techniques with value for developmental biology and ex vivo gene expression studies...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/18/009

    authors: Fumene Feruglio P,Vinegoni C,Gros J,Sbarbati A,Weissleder R

    更新日期:2010-09-21 00:00:00

  • A neural network regression model for relative dose computation.

    abstract::This paper describes a neural network (NN) regression model for relative dose computation. The input signal of the NN model includes depths and field sizes and the output is the relative dose, for example, percentage depth dose (%DD) or tissue-air ratio (TAR) in this paper. After a functional link has been created, th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/4/307

    authors: Wu X,Zhu Y

    更新日期:2000-04-01 00:00:00

  • Scan-rescan and intra-observer variability of magnetic resonance imaging of carotid atherosclerosis at 1.5 T and 3.0 T.

    abstract::Carotid atherosclerosis measurements for eight subjects at baseline and 14 +/- 2 days later were examined using 1.5 T and 3.0 T magnetic resonance imaging (MRI). A single observer blinded to field strength, subject and timepoint manually segmented carotid artery wall and lumen boundaries in randomized images in five m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/23/011

    authors: Vidal A,Bureau Y,Wade T,Spence JD,Rutt BK,Fenster A,Parraga G

    更新日期:2008-12-07 00:00:00

  • A diffusion theory model of spatially resolved fluorescence from depth-dependent fluorophore concentrations.

    abstract::A photon diffusion model has been developed to calculate the steady-state spatially resolved fluorescence from pencil beam excitation in layered tissue. The model allows the calculation of both the excitation reflectance and the fluorescence escape for an arbitrary continuous depth distribution of tissue optical prope...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/2/307

    authors: Hyde DE,Farrell TJ,Patterson MS,Wilson BC

    更新日期:2001-02-01 00:00:00

  • The modulation transfer function of an optical coherence tomography imaging system in turbid media.

    abstract::In this paper we describe measurements of the contrast transfer function, modulation transfer function and point-spread function of an optical coherence tomography (OCT) imaging system through scattering layers having a dimension-less scattering depth over the range 0.2-6.9. The results were found to be insensitive to...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/9/014

    authors: Woolliams PD,Tomlins PH

    更新日期:2011-05-07 00:00:00

  • Linear dimension reduction of sequences of medical images: I. Optimal inner products.

    abstract::A general theory is presented for minimizing noise in linear dimension reduction of sequences of medical images when the factors and the covariance matrix and mean of the noise are given. A dimension reduction is optimal when all diagonal elements in the covariance matrix of the noise in the signal (factor) space are ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/11/010

    authors: Hermansen F,Lammertsma AA

    更新日期:1995-11-01 00:00:00

  • Skin dose in chest wall radiotherapy with bolus: a Monte Carlo study.

    abstract::Monte Carlo simulations are used to investigate skin dose resulting from chest wall radiotherapy with bolus. A simple model of a female thorax is developed, which includes a 2 mm-thick skin layer. Two representative 6 MV source models are considered: a tangents source model consisting of a parallel opposed pair of med...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab95dc

    authors: Oliver PAK,Monajemi TT

    更新日期:2020-08-11 00:00:00

  • On MEG forward modelling using multipolar expansions.

    abstract::Magnetoencephalography (MEG) is a non-invasive functional imaging modality based on the measurement of the external magnetic field produced by neural current sources within the brain. The reconstruction of the underlying sources is a severely ill-posed inverse problem typically tackled using either low-dimensional par...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/4/301

    authors: Jerbi K,Mosher JC,Baillet S,Leahy RM

    更新日期:2002-02-21 00:00:00

  • Real-time motion-adaptive-optimization (MAO) in TomoTherapy.

    abstract::IMRT delivery follows a planned leaf sequence, which is optimized before treatment delivery. However, it is hard to model real-time variations, such as respiration, in the planning procedure. In this paper, we propose a negative feedback system of IMRT delivery that incorporates real-time optimization to account for i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/14/003

    authors: Lu W,Chen M,Ruchala KJ,Chen Q,Langen KM,Kupelian PA,Olivera GH

    更新日期:2009-07-21 00:00:00

  • CT reconstruction algorithm for a dental panoramic x-ray unit.

    abstract::A variable Jacobian and weighted backprojection algorithm, used for medical CT, was adapted to perform CT reconstructions on data obtained with a dental panoramic x-ray unit. A detector array, fitted to the unit for the purpose of acquiring digital panoramic radiographs, was used to collect the data. Compensations wer...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/12/001

    authors: Lee MD,Waggener RG,McDavid WD,Dove SB,Welander U,Tronje G

    更新日期:1992-12-01 00:00:00

  • Assessment of organ-specific neutron equivalent doses in proton therapy using computational whole-body age-dependent voxel phantoms.

    abstract::Proton beams used for radiotherapy will produce neutrons when interacting with matter. The purpose of this study was to quantify the equivalent dose to tissue due to secondary neutrons in pediatric and adult patients treated by proton therapy for brain lesions. Assessment of the equivalent dose to organs away from the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/3/012

    authors: Zacharatou Jarlskog C,Lee C,Bolch WE,Xu XG,Paganetti H

    更新日期:2008-02-07 00:00:00

  • Optimization of image quality and dose for Varian aS500 electronic portal imaging devices (EPIDs).

    abstract::This study was carried out to investigate whether the electronic portal imaging (EPI) acquisition process could be optimized, and as a result tolerance and action levels be set for the PIPSPro QC-3V phantom image quality assessment. The aim of the optimization process was to reduce the dose delivered to the patient wh...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/23/006

    authors: McGarry CK,Grattan MW,Cosgrove VP

    更新日期:2007-12-07 00:00:00

  • Determination of fractional flow reserve (FFR) based on scaling laws: a simulation study.

    abstract::Fractional flow reserve (FFR) provides an objective physiological evaluation of stenosis severity. A technique that can measure FFR using only angiographic images would be a valuable tool in the cardiac catheterization laboratory. To perform this, the diseased blood flow can be measured with a first pass distribution ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/14/017

    authors: Wong JT,Molloi S

    更新日期:2008-07-21 00:00:00

  • The modelling of biological systems in three dimensions using the time domain finite-difference method: I. The implementation of the model.

    abstract::A computer method has been developed which uses the time domain finite-difference (TDFD) algorithm to calculate the deposition of the electromagnetic (EM) field in three-dimensional biological models. This, the first of two papers, describes the algorithm and the computer programs developed. The method is demonstrated...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/11/006

    authors: Lau RW,Sheppard RJ

    更新日期:1986-11-01 00:00:00

  • Characterization of a preclinical PET insert in a 7 Tesla MRI scanner: beyond NEMA testing.

    abstract::This study evaluates the performance of the Bruker positron emission tomograph (PET) insert combined with a BioSpec 70/30 USR magnetic resonance imaging (MRI) scanner using the manufacturer acceptance protocol and the NEMA NU 4-2008 for small animal PET. The PET insert is made of 3 rings of 8 monolithic LYSO crystals ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aba08c

    authors: Gsell W,Molinos C,Correcher C,Belderbos S,Wouters J,Junge S,Heidenreich M,Vande Velde G,Rezaei A,Nuyts J,Cawthorne C,Cleeren F,Nannan L,Deroose CM,Himmelreich U,González Martínez AJ

    更新日期:2020-06-26 00:00:00

  • Ultraviolet phototherapy: review of options for cabin dosimetry and operation.

    abstract::Ultraviolet (UV) treatment dose is determined by the length of time that a patient spends in a phototherapy cabin. The output from UV fluorescent lamps declines with use and a method is needed to compensate for the change in irradiance and to identify and replace any lamps that fail. The decline in lamp output with ag...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/2/008

    authors: Amatiello H,Martin CJ

    更新日期:2006-01-21 00:00:00

  • Evaluation of a novel triple-channel radiochromic film analysis procedure using EBT2.

    abstract::A novel approach to read out radiochromic film was introduced recently by the manufacturer of GafChromic film. In this study, the performance of this triple-channel film dosimetry method was compared against the conventional single-red-channel film dosimetry procedure, with and without inclusion of a pre-irradiation (...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/13/4353

    authors: van Hoof SJ,Granton PV,Landry G,Podesta M,Verhaegen F

    更新日期:2012-07-07 00:00:00