Modelling infrared temperature measurements: implications for laser irradiation and cryogen cooling studies.

Abstract:

:The use of thermographic techniques has increased as infrared detector technology has evolved and improved. For laser-tissue interactions, thermal cameras have been used to monitor the thermal response of tissue to pulsed and continuous wave irradiation. It is important to note that the temperature indicated by the thermal camera may not be equal to the actual surface temperature. It is crucial to understand the limitations of using thermal cameras to measure temperature during laser irradiation of tissue. The goal of this study was to demonstrate the potential difference between measured and actual surface temperatures in a quantitative fashion using a ID finite difference model. Three ablation models and one cryogen spray cooling simulation were adapted from the literature, and predictions of radiometric temperature measurements were calculated. In general, (a) steep superficial temperature gradients, with a surface peak, resulted in an underestimation of the actual surface temperature, (b) steep superficial temperature gradients, with a subsurface peak, resulted in an overestimation, and (c) small gradients led to a relatively accurate temperature estimate.

journal_name

Phys Med Biol

authors

Choi B,Pearce JA,Welch AJ

doi

10.1088/0031-9155/45/2/319

subject

Has Abstract

pub_date

2000-02-01 00:00:00

pages

541-57

issue

2

eissn

0031-9155

issn

1361-6560

journal_volume

45

pub_type

杂志文章
  • Development of a fast Monte Carlo dose calculation system for online adaptive radiation therapy quality assurance.

    abstract::Online adaptive radiation therapy (ART) based on real-time magnetic resonance imaging represents a paradigm-changing treatment scheme. However, conventional quality assurance (QA) methods based on phantom measurements are not feasible with the patient on the treatment couch. The purpose of this work is to develop a fa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6e38

    authors: Wang Y,Mazur TR,Park JC,Yang D,Mutic S,Li HH

    更新日期:2017-06-21 00:00:00

  • A new method to reconstruct intra-fractional prostate motion in volumetric modulated arc therapy.

    abstract::Intra-fractional motion is a concern during prostate radiation therapy, as it may cause deviations between planned and delivered radiation doses. Because accurate motion information during treatment delivery is critical to address dose deviation, we developed the projection marker matching method (PM3), a novel method...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6e37

    authors: Chi Y,Rezaeian NH,Shen C,Zhou Y,Lu W,Yang M,Hannan R,Jia X

    更新日期:2017-07-07 00:00:00

  • Reply to Comment: 'A novel method for fast and robust estimation of fluorescence decay dynamics using constrained least-square deconvolution with Laguerre expansion'.

    abstract::In this response we underscore that the instrumentation described in the original publication (Liu et al 2012 Phys. Med. Biol. 57 843-65) was based on pulse-sampling technique, while the comment by Zhang et al is based on the assumption that a time-correlated single photon counting (TCSPC) instrumentation was used. Th...

    journal_title:Physics in medicine and biology

    pub_type: 评论,杂志文章

    doi:10.1088/1361-6560/aa5231

    authors: Ma D,Liu J,Qi J,Marcu L

    更新日期:2017-02-21 00:00:00

  • W value measurements for protons in tissue-equivalent gas and its constituent gases.

    abstract::Values of W (the mean energy required to create an ion pair when a charged particle is stopped in a gas) are needed in radiation dosimetry to convert ionisation chamber current readings to absorbed dose. For neutron dosimetry the most important W values are those for protons, and this paper describes absolute measurem...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/11/003

    authors: Thomas DJ,Burke M

    更新日期:1985-11-01 00:00:00

  • SNR and noise measurements for medical imaging: I. A practical approach based on statistical decision theory.

    abstract::A method of measuring the image quality of medical imaging equipment is considered within the framework of statistical decision theory. In this approach, images are regarded as random vectors and image quality is defined in the context of the image information available for performing a specified detection or discrimi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/38/1/006

    authors: Tapiovaara MJ,Wagner RF

    更新日期:1993-01-01 00:00:00

  • Exploiting flow to control the in vitro spatiotemporal distribution of microbubble-seeded acoustic cavitation activity in ultrasound therapy.

    abstract::Focused ultrasound and microbubbles have been extensively used to generate therapeutic bioeffects. Despite encouraging in vivo results, there remains poor control of the magnitude and spatial distribution of these bioeffects due to the limited ability of conventional pulse shapes and sequences to control cavitation dy...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/22/6941

    authors: Pouliopoulos AN,Bonaccorsi S,Choi JJ

    更新日期:2014-11-21 00:00:00

  • Organ and effective doses in newborn patients during helical multislice computed tomography examination.

    abstract::In this study, two computational phantoms of the newborn patient were used to assess individual organ doses and effective doses delivered during head, chest, abdomen, pelvis, and torso examinations using the Siemens SOMATOM Sensation 16 helical multi-slice computed tomography (MSCT) scanner. The stylized phantom used ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/20/005

    authors: Staton RJ,Lee C,Lee C,Williams MD,Hintenlang DE,Arreola MM,Williams JL,Bolch WE

    更新日期:2006-10-21 00:00:00

  • Development and comparison of computer methods for organ motion correction in scintigraphy.

    abstract::The process of organ motion correction in scintigraphy is analysed in the frequency domain. The sequence of the chi- and gamma- coordinates registered during scintigraphic recording is converted to a frequency spectrum by a discrete Fourier transform. In the frequency domain motion correction is performed by linear fi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/20/3/010

    authors: Schmidlin P

    更新日期:1975-05-01 00:00:00

  • Low density contrast agents for x-ray phase contrast imaging: the use of ambient air for x-ray angiography of excised murine liver tissue.

    abstract::We report a new preparative method for providing contrast through reduction in electron density that is uniquely suited for propagation-based differential x-ray phase contrast imaging. The method, which results in an air or fluid filled vasculature, makes possible visualization of the smallest microvessels, roughly do...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/23/017

    authors: Laperle CM,Hamilton TJ,Wintermeyer P,Walker EJ,Shi D,Anastasio MA,Derdak Z,Wands JR,Diebold G,Rose-Petruck C

    更新日期:2008-12-07 00:00:00

  • Dynamic beam modulation by using a single computer-controlled absorber.

    abstract::The authors have developed an apparatus able to generate ID intensity-modulated beams, using only one moving absorber within the irradiation field. A procedure for deriving optimized absorber-speed profiles in order to produce the desired fluence/dose profiles has been suggested. Experimental tests show that the syste...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/2/002

    authors: Fiorino C,Lev A,Fusca M,Cattaneo GM,Rudello F,Calandrino R

    更新日期:1995-02-01 00:00:00

  • An investigation of automatic exposure control calibration for chest imaging with a computed radiography system.

    abstract::The purpose of this study was to examine the use of three physical image quality metrics in the calibration of an automatic exposure control (AEC) device for chest radiography with a computed radiography (CR) imaging system. The metrics assessed were signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and mean ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/9/2307

    authors: Moore CS,Wood TJ,Avery G,Balcam S,Needler L,Beavis AW,Saunderson JR

    更新日期:2014-05-07 00:00:00

  • Multi-feature-based plaque characterization in ex vivo MRI trained by registration to 3D histology.

    abstract::We present a new method for automated characterization of atherosclerotic plaque composition in ex vivo MRI. It uses MRI intensities as well as four other types of features: smoothed, gradient magnitude and Laplacian images at several scales, and the distances to the lumen and outer vessel wall. The ground truth for f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/1/241

    authors: van Engelen A,Niessen WJ,Klein S,Groen HC,Verhagen HJ,Wentzel JJ,van der Lugt A,de Bruijne M

    更新日期:2012-01-07 00:00:00

  • Image quality assessment in digital mammography: part II. NPWE as a validated alternative for contrast detail analysis.

    abstract::Assessment of image quality for digital x-ray mammography systems used in European screening programs relies mainly on contrast-detail CDMAM phantom scoring and requires the acquisition and analysis of many images in order to reduce variability in threshold detectability. Part II of this study proposes an alternative ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/14/003

    authors: Monnin P,Marshall NW,Bosmans H,Bochud FO,Verdun FR

    更新日期:2011-07-21 00:00:00

  • Introducing the Jacobian-volume-histogram of deforming organs: application to parotid shrinkage evaluation.

    abstract::The Jacobian of the deformation field of elastic registration between images taken during radiotherapy is a measure of inter-fraction local deformation. The histogram of the Jacobian values (Jac) within an organ was introduced (JVH-Jacobian-volume-histogram) and first applied in quantifying parotid shrinkage. MVCTs of...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/11/008

    authors: Fiorino C,Maggiulli E,Broggi S,Liberini S,Cattaneo GM,Dell'oca I,Faggiano E,Di Muzio N,Calandrino R,Rizzo G

    更新日期:2011-06-07 00:00:00

  • Integration of dynamic contrast-enhanced magnetic resonance imaging and T2-weighted imaging radiomic features by a canonical correlation analysis-based feature fusion method to predict histological grade in ductal breast carcinoma.

    abstract::Tumour histological grade has prognostic implications in breast cancer. Tumour features in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and T2-weighted (T2W) imaging can provide related and complementary information in the analysis of breast lesions to improve MRI-based histological status prediction...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab3fd3

    authors: Fan M,Liu Z,Xie S,Xu M,Wang S,Gao X,Li L

    更新日期:2019-10-23 00:00:00

  • Another decade of photoacoustic imaging.

    abstract::Photoacoustic imaging - a hybrid biomedical imaging modality finding its way to clinical practices. Although the photoacoustic phenomenon was known more than a century back, only in the last two decades it has been widely researched and used for biomedical imaging applications. In this review we focus on the developme...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abd669

    authors: Das D,Sharma A,Rajendran P,Pramanik M

    更新日期:2020-12-23 00:00:00

  • Investigation of the sag in linac secondary collimator and MLC carriage during arc deliveries.

    abstract::In modern radiotherapy, it is vitally important to monitor the performance of all linac components including the collimation system. In this study, a simple measurement method and accurate algorithm are introduced for investigation of the secondary and tertiary collimator sag during radiotherapy arc treatments. The me...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/12/N209

    authors: Rowshanfarzad P,Sabet M,O'Connor DJ,Greer PB

    更新日期:2012-06-21 00:00:00

  • Neutron scattering cross sections and partial kerma values for oxygen, nitrogen and calcium at 18 less than En less than 60 MeV.

    abstract::Recent measurements of differential elastic and inelastic neutron scattering from oxygen, nitrogen and calcium at 18 less than En less than 26 MeV are presented and analysed in terms of the optical model. These data, together with earlier measurements of scattering and total cross sections, are used to construct model...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/33/3/001

    authors: Islam MS,Finlay RW,Petler JS,Rapaport J,Alarcon R,Wierzbicki J

    更新日期:1988-03-01 00:00:00

  • Block matching 3D random noise filtering for absorption optical projection tomography.

    abstract::Absorption and emission optical projection tomography (OPT), alternatively referred to as optical computed tomography (optical-CT) and optical-emission computed tomography (optical-ECT), are recently developed three-dimensional imaging techniques with value for developmental biology and ex vivo gene expression studies...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/18/009

    authors: Fumene Feruglio P,Vinegoni C,Gros J,Sbarbati A,Weissleder R

    更新日期:2010-09-21 00:00:00

  • Arc-modulated radiation therapy based on linear models.

    abstract::This paper reports an inverse arc-modulated radiation therapy planning technique based on linear models. It is implemented with a two-step procedure. First, fluence maps for 36 fixed-gantry beams are generated using a linear model-based intensity-modulated radiation therapy (IMRT) optimization algorithm. The 2D fluenc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/13/020

    authors: Zhu X,Thongphiew D,McMahon R,Li T,Chankong V,Yin FF,Wu QJ

    更新日期:2010-07-07 00:00:00

  • An automated method for adaptive radiation therapy for prostate cancer patients using continuous fiducial-based tracking.

    abstract::Electromagnetic tracking technology is primarily used for continuous prostate localization during radiotherapy, but offers potential value for evaluation of dosimetric coverage and adequacy of treatment for dynamic targets. We developed a highly automated method for daily computation of cumulative dosimetric effects o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/1/005

    authors: Noel CE,Santanam L,Olsen JR,Baker KW,Parikh PJ

    更新日期:2010-01-07 00:00:00

  • HeinzelCluster: accelerated reconstruction for FORE and OSEM3D.

    abstract::Using iterative three-dimensional (3D) reconstruction techniques for reconstruction of positron emission tomography (PET) is not feasible on most single-processor machines due to the excessive computing time needed, especially so for the large sinogram sizes of our high-resolution research tomograph (HRRT). In our fir...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/15/307

    authors: Vollmar S,Michel C,Treffert JT,Newport DF,Casey M,Knöss C,Wienhard K,Liu X,Defrise M,Heiss WD

    更新日期:2002-08-07 00:00:00

  • Laser speckle imaging of blood flow in microcirculation.

    abstract::Monitoring the spatio-temporal characteristics of microcirculation is crucial for studying the functional activities of biotissue and the mechanism of disease. However, conventional methods used to measure blood flow suffer from limited spatial resolution or the injection of exogenous substances or the need of scannin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/7/020

    authors: Cheng H,Luo Q,Liu Q,Lu Q,Gong H,Zeng S

    更新日期:2004-04-07 00:00:00

  • An edge-on charge-transfer design for energy-resolved x-ray detection.

    abstract::As an x-ray beam goes through the human body, it will collect important information via interaction with tissues. Since this interaction is energy-sensitive, the state-of-the-art spectral CT technologies provide higher quality images of biological tissues with x-ray energy information (or spectral information). With e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/11/4183

    authors: Shi Z,Yang H,Cong W,Wang G

    更新日期:2016-06-07 00:00:00

  • Elastostatics of a spherical inclusion in homogeneous biological media.

    abstract::A three-dimensional spherical inclusion model that approximates a lesion bonded to a tissue matrix is proposed for biomedical elastography. Analytical formulae describing spatial strain and stress distributions generated in infinite media by uniform loading are given under a linear, homogeneous, isotropic elasticity a...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/1/001

    authors: Bilgen M,Insana MF

    更新日期:1998-01-01 00:00:00

  • A method to reconstruct intra-fractional liver motion in rotational radiotherapy using linear fiducial markers.

    abstract::Complex intra-fractional motion and deformation of the liver significantly impacts the accuracy of delivered dose in radiotherapy. It limits margin reduction, dose escalation and normal tissue sparing. A critical component of motion management is to accurately reconstruct tumor motion. In this study, we developed a si...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab4c0d

    authors: Chi Y,Shen C,Li B,Zhang Y,Yang M,Folkert M,Jia X

    更新日期:2019-11-21 00:00:00

  • Robust radiation therapy optimization using simulated treatment courses for handling deformable organ motion.

    abstract::We describe a radiation therapy treatment plan optimization method that explicitly considers the effects of interfraction organ motion through optimization on the clinical target volume (CTV), and investigate how it compares to conventional planning using a planning target volume (PTV). The method uses simulated treat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abd591

    authors: Fredriksson A,Engwall E,Andersson B

    更新日期:2020-12-21 00:00:00

  • A mathematical model for predicting the changes of non-small cell lung cancer based on tumor mass during radiotherapy.

    abstract::This study aims to build a feasible mathematical model to analyze the mass evolution of NSCLC during standard fractionated radiotherapy. Seventy-three cases of NSCLC who were received radiotherapy with prescription dose of 2 Gy  ×  30 fx were selected retrospectively and divided into adenocarcinoma (ADC) group and squ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab47c0

    authors: Chen J,Wang K,Jian J,Zhang W

    更新日期:2019-11-26 00:00:00

  • Effect of electron contamination of a 6 MV x-ray beam on near surface diode dosimetry.

    abstract::In critical organ in vivo x-ray dosimetry, the relative contaminating electron contribution to the total dose and total detector response outside the field will be different to the corresponding contributions at the central axis detector calibration position, mainly due to the effects of shielding in the linear accele...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/24/013

    authors: Edwards CR,Mountford PJ,Moloney AJ

    更新日期:2006-12-21 00:00:00

  • Image reconstruction.

    abstract::We give an overview of the role of Physics in Medicine and Biology in the development of tomographic reconstruction algorithms. We focus on imaging modalities involving ionizing radiation, CT, PET and SPECT, and cover a wide spectrum of reconstruction problems, starting with classical 2D tomography in the 1970s up to ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/51/13/R09

    authors: Defrise M,Gullberg GT

    更新日期:2006-07-07 00:00:00