Abstract:
:This paper describes a neural network (NN) regression model for relative dose computation. The input signal of the NN model includes depths and field sizes and the output is the relative dose, for example, percentage depth dose (%DD) or tissue-air ratio (TAR) in this paper. After a functional link has been created, the expressing ability of input patterns and the resolution of neural networks are enhanced. The trained neural network exhibits a good generalization and interpolation ability, and it can be easily extended to other relative dose regressions. We present two examples to verify the fitness of this model. The first calculates the percentage depth dose of a 14 MV x-ray beam for field sizes of 5 cm x 5 cm to 28 cm x 28 cm. The average error computed from the NN is less than 0.47% comparing with the original measured %DD. The second example calculates the TAR of a 4 MV x-ray beam for field sizes of 5 cm x 5 cm to 20 cm x 20 cm. In this example, the training data show that the average error computed from the NN is less than 0.48%, whereas that from the testing data is less than 0.37% after training. Such an NN model can be generalized to fit data for treatment planning with any linear accelerator and can also fit data stored as tissue-maximum ratio (TMR) and tissue-phantom ratio (TPR).
journal_name
Phys Med Bioljournal_title
Physics in medicine and biologyauthors
Wu X,Zhu Ydoi
10.1088/0031-9155/45/4/307subject
Has Abstractpub_date
2000-04-01 00:00:00pages
913-22issue
4eissn
0031-9155issn
1361-6560journal_volume
45pub_type
杂志文章abstract::Radiomic features achieve promising results in cancer diagnosis, treatment response prediction, and survival prediction. Our goal is to compare the handcrafted (explicitly designed) and deep learning (DL)-based radiomic features extracted from pre-treatment diffusion-weighted magnetic resonance images (DWIs) for predi...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab7970
更新日期:2020-04-02 00:00:00
abstract::A mathematical procedure, using Fourier deconvolution, is described whereby diffusion-free proximity functions can be obtained from cloud-chamber data. Such non-diffused distributions can be used to obtain further microdosimetric and nanodosimetric quantities hitherto not available from experiments, thus making the cl...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/33/11/004
更新日期:1988-11-01 00:00:00
abstract::Image-guided radiation therapy using implanted fiducial markers is a common solution for prostate localization to improve targeting accuracy. However, fiducials that are typically used for conventional photon radiotherapy cause large dose perturbations in patients who receive proton radiotherapy. A proposed solution h...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/23/S13
更新日期:2010-12-07 00:00:00
abstract::An optimized configuration of multi-pinhole aperture can improve the spatial resolution and the sensitivity of pinhole SPECT simultaneously. In this study, an optimization strategy of the multi-pinhole configuration with a small detector is proposed for mouse cardiac imaging. A 14 mm-diameter spherical field-of-view (...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/2/473
更新日期:2015-01-21 00:00:00
abstract::Monte Carlo simulation provides a valuable tool in performance assessment and optimization of system design parameters for PET scanners. SimSET is a popular Monte Carlo simulation toolkit that features fast simulation time, as well as variance reduction tools to further enhance computational efficiency. However, SimSE...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/3/N35
更新日期:2015-02-07 00:00:00
abstract::Various lead attenuation techniques to determine the fast neutron sensitivity kU of a photon dosemeter are reviewed and a modified method is proposed to determine the kU value of a commercially available Geiger--Müller detector. The dependence on the 'effective' photon energy of the gamma-component of the mixed n--gam...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/24/4/005
更新日期:1979-07-01 00:00:00
abstract::Focused ultrasound and microbubbles have been extensively used to generate therapeutic bioeffects. Despite encouraging in vivo results, there remains poor control of the magnitude and spatial distribution of these bioeffects due to the limited ability of conventional pulse shapes and sequences to control cavitation dy...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/22/6941
更新日期:2014-11-21 00:00:00
abstract::The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial "tumours" were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the "tumours" were impl...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/1/007
更新日期:2007-01-07 00:00:00
abstract::This study verifies the concept of the super-omni wedge by validating its equations for effective wedge orientation and wedge angle and by comparing the dose distributions it produces with those produced by other wedge techniques. To validate the equations, we calculated dose distributions for 20 combinations of wedge...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/46/9/313
更新日期:2001-09-01 00:00:00
abstract::We propose a method to compensate for six degree-of-freedom rigid motion in helical CT of the head. The method is demonstrated in simulations and in helical scans performed on a 16-slice CT scanner. Scans of a Hoffman brain phantom were acquired while an optical motion tracking system recorded the motion of the bed an...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/5/2047
更新日期:2015-03-07 00:00:00
abstract::Magnetic resonance and ultrasound elastography techniques are now important tools for staging high-grade fibrosis in patients with chronic liver disease. However, uncertainty remains about the effects of simple accumulation of fat (steatosis) and inflammation (steatohepatitis) on the parameters that can be measured us...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aac09a
更新日期:2018-05-17 00:00:00
abstract::Dental tomographic cone-beam x-ray imaging devices record truncated projections and reconstruct a region of interest (ROI) inside the head. Image reconstruction from the resulting local tomography data is an ill-posed inverse problem. A new Bayesian multiresolution method is proposed for local tomography reconstructio...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/22/008
更新日期:2007-11-21 00:00:00
abstract::In this work, a procedure, based on Monte Carlo techniques, to analyse the effect on the tumour control probability of the time interval between surgery and postoperative radiotherapy is presented. The approach includes the tumour growth as well as the survival of tumour cells undergoing fractionated radiotherapy. Bot...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/49/13/005
更新日期:2004-07-07 00:00:00
abstract::This work aims to develop, implement and validate a Monte Carlo (MC)-based independent dose calculation (IDC) framework to perform patient-specific quality assurance (QA) for multi-leaf collimator (MLC)-based CyberKnife® (Accuray Inc., Sunnyvale, CA) treatment plans. The IDC framework uses an XML-format treatment plan...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa97f8
更新日期:2017-12-19 00:00:00
abstract::In treatment planning we depend upon accurate knowledge of geometric and range uncertainties. If the uncertainty model is inaccurate then the plan will produce under-dosing of the target and/or overdosing of OAR. We aim to provide a method for which centre and site-specific population range uncertainty due to inter-fr...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa9502
更新日期:2017-12-19 00:00:00
abstract::Over the last 50 years, diagnostic imaging has grown from a state of infancy to a high level of maturity. Many new imaging modalities have been developed. However, modern medical imaging includes not only image production but also image processing, computer-aided diagnosis (CAD), image recording and storage, and image...
journal_title:Physics in medicine and biology
pub_type: 杂志文章,评审
doi:10.1088/0031-9155/51/13/R02
更新日期:2006-07-07 00:00:00
abstract::Four-dimensional volumetric modulated arc therapy (4D VMAT) is a treatment strategy for lung cancers that aims to exploit relative target and tissue motion to improve organ at risk (OAR) sparing. The algorithm incorporates the entire patient respiratory cycle using 4D CT data into the optimization process. Resulting t...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/4/749
更新日期:2013-02-21 00:00:00
abstract::Techniques for reducing computation time in 3D photon dose calculations are addressed with specific emphasis given to the convolution/superposition approach. A single polyenergetic superposition model calculating absorbed dose per incident photon fluence (Gy cm2) was developed in terms of TERMA and a total energy depo...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/42/8/001
更新日期:1997-08-01 00:00:00
abstract::Radiochromic films are useful as dosimeters in high-precision radiotherapy owing to their high spatial resolution. However, when a particle beam is measured using a radiochromic film, the dose cannot be estimated accurately because the film darkness varies with variations in linear energy transfer (LET). This paper pr...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab8bf3
更新日期:2020-06-15 00:00:00
abstract::The incorporation of accurately aligned anatomical information as a prior to guide reconstruction and noise regularization in positron emission tomography (PET) has been suggested in many previous studies. However, the advantages of this approach can only be realized if the exact lesion outline is also available. In p...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/24/009
更新日期:2009-12-21 00:00:00
abstract::Large blood vessels can produce steep temperature gradients in heated tissues leading to inadequate tissue temperatures during hyperthermia. This paper utilizes a finite difference scheme to solve the basic equations of heat transfer and fluid flow to model blood vessel cooling. Unlike previous formulations, heat tran...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/40/4/001
更新日期:1995-04-01 00:00:00
abstract::In proton scanning systems that employ active energy variation for depth modulation, a switch of the particle energy might typically require 1-2 s. For plans comprising many energy slices, these seconds could sum up to a non-negligible fraction of the total treatment duration. We have applied the Nyquist-Shannon sampl...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/9/N01
更新日期:2008-05-07 00:00:00
abstract::Effective detective quantum efficiency (eDQE) describes the resolution and noise properties of an imaging system along with scatter and primary transmission, all measured under clinically appropriate conditions. Effective dose efficiency (eDE) is the eDQE normalised to mean glandular dose and has been proposed as a us...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aaa307
更新日期:2018-01-16 00:00:00
abstract::We evaluated the basic properties of a commercially available BANGkit gel dosimeter, which is a normoxic type of BANG gel. This gel-kit has the same composition as the BANG 3 gel, but is fully oxygenated. To exclude oxygen, oxygen scavenging ascorbic acid and copper sulfate as a catalyst are used. The properties that ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/8/017
更新日期:2007-04-21 00:00:00
abstract::Recent measurements of differential elastic and inelastic neutron scattering from oxygen, nitrogen and calcium at 18 less than En less than 26 MeV are presented and analysed in terms of the optical model. These data, together with earlier measurements of scattering and total cross sections, are used to construct model...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/33/3/001
更新日期:1988-03-01 00:00:00
abstract::Usually, Monte Carlo models are validated against experimental data. However, models of multiple Coulomb scattering (MCS) in the Gaussian approximation are exceptional in that we have theories which are probably more accurate than the experiments which have, so far, been done to test them. In problems directly sensiti...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa6ce3
更新日期:2017-07-06 00:00:00
abstract::The temperature sensitivities of absorption and reduced scattering coefficients in the range 700-1000 nm are determined for the liquid phantom Intralipid using spatially resolved continuous wave measurements. The measurements were conducted on a 10 L heated volume of 1% Intralipid subjected to a 40-30 degrees C coolin...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/9/003
更新日期:2007-05-07 00:00:00
abstract::Stereotactic Gamma Knife radiosurgery utilizes ionizing beams from (60)Co sources and relies on a combination of collimator sizes, weighting, etc to generate a high-dose region that is conformal with a designated target volume. Dose computation is typically performed by computer, but in this paper, single collimator d...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/8/003
更新日期:2008-04-21 00:00:00
abstract::Blood was withdrawn from the ante-cubital vein of five normal volunteers and the erythrocytes were washed and resuspended in isotonic saline. The rate of descent of the erythrocyte-saline boundary was measured every hour for a period of at least 4 h for different suspended cell concentrations. The velocity of this bou...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/30/2/002
更新日期:1985-02-01 00:00:00
abstract::Although the calculation of the surface average of the low-frequency current density distribution over a cross-section of 1 cm2 is required by ICNIRP guidelines, no reference averaging algorithm is indicated, neither in the ICNIRP guidelines nor in the Directive 2004/40/EC that is based on them. The lack of a general ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/15/013