Abstract:
:In carbon-ion radiotherapy, single-beam delivery each day in alternate directions has been common practice for efficient operation, taking advantage of the Bragg peak and the relative biological effectiveness (RBE) for uniform dose conformation to a tumor. Treatments are usually fractionated and treatment plans are evaluated with the total RBE-weighted dose; however, this is of limited relevance to the biological effect. In this study, we reformulate the biologically effective dose (BED) to normalize the dose-fractionation and cell-repopulation effects as well as the RBE of treating radiation, based on inactivation of a reference cell line by a reference carbon-ion radiation. The BED distribution virtually represents the biological effect of a treatment regardless of radiation modality or fractionation scheme. We applied the BED formulation to simplistic model treatments and to a preclinical survey for hypofractionation based on an actual prostate cancer treatment with carbon ions. The proposed formulation was demonstrated to be practical and to give theoretical implications. For a prostate cancer treatment in 12 fractions, the distributions of BED and of RBE-weighted dose were very similar. With hypofractionation, while the RBE-weighted dose distribution varied significantly, the BED distribution was nearly invariant, implying that carbon-ion radiotherapy would be effectively insensitive to fractionation. However, treatment evaluation with such a simplistic biological dose is intrinsically limited and must be complemented in practice by clinical experience and biological experiments.
journal_name
Phys Med Bioljournal_title
Physics in medicine and biologyauthors
Kanematsu N,Inaniwa Tdoi
10.1088/1361-6560/62/3/1062subject
Has Abstractpub_date
2017-02-07 00:00:00pages
1062-1075issue
3eissn
0031-9155issn
1361-6560journal_volume
62pub_type
杂志文章abstract::A calibration of the Fricke dosimeter is a measurement of epsilon G(Fe3+). Although G(Fe3+) is expected to be approximately energy independent for all low-LET radiation, existing data are not adequate to rule out the possibility of changes of a few per cent with beam quality. When a high-precision Fricke dosimeter, wh...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/44/7/303
更新日期:1999-07-01 00:00:00
abstract::The feasibility of detecting gamma rays with energies below 1.5 MeV by means of a large-volume liquid-filled Cerenkov counter has been examined, together with the characteristics and limitations of an experimental counter. Various liquids (water, glycerol, sodium iodide solution; and glycerol plus a wavelength shifter...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/23/3/007
更新日期:1978-05-01 00:00:00
abstract::In BANG gel dosimetry, the spin-spin relaxation rate, R2 = I/T2, is related to the radiation dose that has been delivered to the gel phantom. R2 is calculated by fitting the pixel intensities of a set of differently T2-weighted base images. In gel dosimetry for radiotherapy, an accuracy of 5% in dose and 3 mm spatiall...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/45/7/307
更新日期:2000-07-01 00:00:00
abstract::Histotripsy is an ultrasound ablation method that depends on the initiation of a cavitation bubble cloud to fractionate soft tissue. Although previous work has provided significant insight into the process of intrinsic threshold histotripsy, the majority of these studies have used highly focused (i.e. f-number < 0.6...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa54c7
更新日期:2017-02-21 00:00:00
abstract::In this paper, we have investigated the feasibility of imaging the mechanical behavior of poroelastic materials using axial strain elastography. Cylindrical samples obtained from poroelastic materials having different elastic and permeability properties were subjected to a constant compression force (a classical creep...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/11/020
更新日期:2007-06-07 00:00:00
abstract::A transformation method was investigated for applying the MIRD absorbed fraction to internal dose calculations for an individual. The transformation method consists of two parts, transformation of the target organ mass, and of the distance between source and target organs. The variation of the specific absorbed fracti...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/20/4/006
更新日期:1975-07-01 00:00:00
abstract::In the IAEA TRS-381 protocol, k(cel) and p(cel) account for the central electrode perturbation during the air kerma chamber calibration and the in-phantom measurements. The values of these correction factors are based mainly on Monte Carlo simulations. In the present work experimental data on k(cel) and p(cel) for the...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/44/5/315
更新日期:1999-05-01 00:00:00
abstract::The treatment of large tumors such as sarcomas with intra-operative radiotherapy using a Mobetron is often complicated because of the limited field size of the primary collimator and the available applicators (max Ø100 mm). To circumvent this limitation a prototype rectangular applicator of 80 x 150 mm(2) was designed...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/8/006
更新日期:2008-04-21 00:00:00
abstract::Recently, there has been a resurgence of interest in arc-based IMRT, through the use of 'conventional' multileaf collimator (MLC) systems that can treat large tumor volumes in a single, or very few pass(es) of the gantry. Here we present a novel 'burst mode' modulated arc delivery approach, wherein 2000 monitor units ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/7/002
更新日期:2011-04-07 00:00:00
abstract::We report on a radiographic measurement of an ex vivo human knee using a grating-based phase-contrast imaging setup and a medical x-ray tube at a tube voltage of 70 kV. The measurement has been carried out using a Talbot-Lau setup that is suitable to achieve a high visibility in the energy regime of medical imaging. I...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa7721
更新日期:2017-08-01 00:00:00
abstract::The measurement of output factors (OF) for the small photon beams generated by Leksell Gamma Knife® (LGK) radiotherapy units is a challenge for the physicist due to the under or over estimation of these factors by a vast majority of the detectors commercially available. Output correction factors, introduced in the int...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/10/3959
更新日期:2015-05-21 00:00:00
abstract::This paper analyzes the radio frequencies (RF) exposure in the head tissues of children using a cellular handset or RF sources (a dipole and a generic handset) at 900, 1800, 2100 and 2400 MHz. Based on magnetic resonance imaging, child head models have been developed. The maximum specific absorption rate (SAR) over 10...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/13/019
更新日期:2008-07-07 00:00:00
abstract::For the treatment planning during intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT), beam fluence maps can be first optimized via fluence map optimization (FMO) under the given dose prescriptions and constraints to conformally deliver the radiation dose to the targets while sparin...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/61/7/2838
更新日期:2016-04-07 00:00:00
abstract::The dynamic magnetization of immobilized spherical single-domain magnetic nanoparticles (MNPs) with uniaxial or cubic magnetocrystalline anisotropy was studied computationally by executing simulations based on the Landau-Lifshitz-Gilbert (LLG) equation. For situations when a static magnetic field was suddenly applied ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab5b83
更新日期:2020-01-17 00:00:00
abstract::The Hug-Kellerer (H-K) equation is one of the earliest proposed radiation cell survival curves. We examine this equation in view of the recent perceived need for a universal cell survival curve which would be applicable to single radiation fractions at high doses. We derive relationships between the three parameters o...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/10/N01
更新日期:2010-05-21 00:00:00
abstract::We propose a method to compensate for six degree-of-freedom rigid motion in helical CT of the head. The method is demonstrated in simulations and in helical scans performed on a 16-slice CT scanner. Scans of a Hoffman brain phantom were acquired while an optical motion tracking system recorded the motion of the bed an...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/5/2047
更新日期:2015-03-07 00:00:00
abstract::EEG recordings made in combined EEG-fMRI studies are corrupted by gradient artefacts (GAs) resulting from the interaction of the EEG system with the time-varying magnetic field gradients used in MRI. The dominant contribution to the GA arises from interaction with the leads of the EEG cap and the human head, but artef...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/12/N241
更新日期:2015-06-21 00:00:00
abstract::Silicon photomultipliers (SiPMs) are widely used in positron emission tomography (PET), however, SiPMs from different vendors vary in their performance characteristics. In addition, the specifications provided by the manufacturers are measured under different operating conditions and using different test setups, makin...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab1c37
更新日期:2019-08-07 00:00:00
abstract::Positron emission tomography is one of the most mature techniques for monitoring the particles range in hadron therapy, aiming to reduce treatment uncertainties and therefore the extent of safety margins in the treatment plan. In-beam PET monitoring has been already performed using inter-spill and post-irradiation dat...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aafa28
更新日期:2019-01-21 00:00:00
abstract::The purpose of this study was to improve the performance of a small gamma camera, utilizing a NaI(Tl) plate and a 5" position sensitive PMT. We attempted to build a NaI(Tl) plate crystal system which retained all its advantages, while at the same time integrating some of the advantages inherent in an array-type scinti...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/49/21/008
更新日期:2004-11-07 00:00:00
abstract::The performance of a light sharing and recirculation mechanism that allows the extraction of depth of interaction (DOI) are investigated in this paper, with a particular focus on timing. In parallel, a method to optimize the coincidence time resolution (CTR) of PET detectors by use of the DOI information is proposed a...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab2cb0
更新日期:2019-08-07 00:00:00
abstract::The behaviour of scatter dose in 4 and 8 MV wedged x-ray beams has been studied by calculating scatter-to-primary dose ratios (SPR) and comparing these with SPR for non-wedged beams. On the central axis the SPR for wedged and non-wedged beams differ only by a few per cent, a difference which increases slightly with we...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/32/10/010
更新日期:1987-10-01 00:00:00
abstract::Incorrect prediction of skin dose in external beam radiotherapy (EBR) can have normal tissue complication such as acute skin desquamation and skin necrosis. The absorbed dose of skin should be evaluated within basal layer, placed between the epidermis and dermis layers. However, current treatment planning systems (TPS...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab2ef5
更新日期:2019-08-14 00:00:00
abstract::The beam quality correction factor k Q for megavoltage photon beams has been calculated for eight PTW (Freiburg, Germany) ionization chambers (Farmer chambers PTW30010, PTW30011, PTW30012, and PTW30013, Semiflex 3D chambers PTW31021, PTW31010, and PTW31013, and the PinPoint 3D chamber PTW31016). Simulations performed ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab9501
更新日期:2020-10-07 00:00:00
abstract::Awake and/or freely moving small animal single photon emission imaging allows the continuous study of molecules exhibiting slow kinetics without the need to restrain or anaesthetise the animals. Estimating motion free projections in freely moving small animal planar imaging can be considered as a limited angle tomogra...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa68cd
更新日期:2017-05-21 00:00:00
abstract::This paper concerns the robustness of discrete wavelet transform (DWT) compression in terahertz pulsed imaging (TPI). TPI datasets consist of terahertz time-domain series which are sampled at each 'pixel' of the image, leading to file sizes which are typically of the order of several megabytes (MB) per image. This mak...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/47/21/328
更新日期:2002-11-07 00:00:00
abstract::Microbeam radiation therapy (MRT) is a treatment approach in radiation therapy where the treatment field is spatially fractionated into arrays of a few tens of micrometre wide planar beams of unusually high peak doses separated by low dose regions of several hundred micrometre width. In preclinical studies, this treat...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa8d63
更新日期:2017-10-19 00:00:00
abstract::Contrast-enhanced ultrasound (US) imaging is potentially applicable to the investigation of vascular disorders of the testis. We investigated the ability of two automated computer algorithms to analyse contrast-enhanced pulse inversion US data in a rabbit model of unilateral testicular ischaemia and to correctly deter...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/51/14/010
更新日期:2006-07-21 00:00:00
abstract::Task group 43 (TG43)-based dosimetry algorithms are efficient for brachytherapy dose calculation in water. However, human tissues have chemical compositions and densities different than water. Moreover, the mutual shielding effect of seeds on each other (interseed attenuation) is neglected in the TG43-based dosimetry ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/11/3273
更新日期:2012-06-07 00:00:00
abstract::Radiotherapy treatment planning relies on the use of geometrically correct images. This paper presents a fully automatic tool for correcting MR images for the effects of B(0) inhomogeneities. The post-processing method is based on the gradient-reversal technique of Chang and Fitzpatrick (1992 IEEE Trans. Med. Imaging ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/50/11/014
更新日期:2005-06-07 00:00:00