Wavelet compression in medical terahertz pulsed imaging.

Abstract:

:This paper concerns the robustness of discrete wavelet transform (DWT) compression in terahertz pulsed imaging (TPI). TPI datasets consist of terahertz time-domain series which are sampled at each 'pixel' of the image, leading to file sizes which are typically of the order of several megabytes (MB) per image. This makes efficient compression highly desirable for both transmission and storage. However, since the data may be required for diagnostic purposes it is essential that no relevant information is lost or artefacts introduced. We show that for a nylon step wedge the estimates of refractive index and absorption coefficients are not significantly altered when the terahertz data are reconstructed from only 20% of DWT coefficients.

journal_name

Phys Med Biol

authors

Handley JW,Fitzgerald AJ,Berry E,Boyle RD

doi

10.1088/0031-9155/47/21/328

subject

Has Abstract

pub_date

2002-11-07 00:00:00

pages

3885-92

issue

21

eissn

0031-9155

issn

1361-6560

journal_volume

47

pub_type

杂志文章
  • Infrasonic analysis of carotid vibration as a diagnostic method in carotid insufficiency syndrome.

    abstract::The infrasonic part of the spectrum of the carotid artery wall vibration in the neck was obtained. Differences between the spectral content and vibrational amplitude in normal and occluded carotids were found. The application of this technique in clinical practice could be useful in the detection of the carotid insuff...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/21/1/011

    authors: Anastassiades AJ,Petounis AD

    更新日期:1976-01-01 00:00:00

  • Imaging of prompt gamma rays emitted during delivery of clinical proton beams with a Compton camera: feasibility studies for range verification.

    abstract::The purpose of this paper is to evaluate the ability of a prototype Compton camera (CC) to measure prompt gamma rays (PG) emitted during delivery of clinical proton pencil beams for prompt gamma imaging (PGI) as a means of providing in vivo verification of the delivered proton radiotherapy beams. A water phantom was i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/18/7085

    authors: Polf JC,Avery S,Mackin DS,Beddar S

    更新日期:2015-09-21 00:00:00

  • Evaluation of nonuniform field exposures with coupling factors.

    abstract::In this study, the safety compliance for nonuniform field exposures is discussed using coupling factor concepts. The coupling factor, which is defined in the International Electrotechnical Commission 62311 standard, is extended to consider the effects of harmonics and also to apply to the specific absorption rate (for...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/20/8129

    authors: Sunohara T,Hirata A,Laakso I,De Santis V,Onishi T

    更新日期:2015-10-21 00:00:00

  • Investigation of patient, tumour and treatment variables affecting residual motion for respiratory-gated radiotherapy.

    abstract::Respiratory gating can reduce the apparent respiratory motion during imaging and treatment; however, residual motion within the gating window remains. Respiratory training can improve respiratory reproducibility and, therefore, the efficacy of respiratory-gated radiotherapy. This study was conducted to determine wheth...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/20/015

    authors: George R,Ramakrishnan V,Siebers JV,Chung TD,Keall PJ

    更新日期:2006-10-21 00:00:00

  • Front-illuminated versus back-illuminated photon-counting CCD-based gamma camera: important consequences for spatial resolution and energy resolution.

    abstract::Charge-coupled devices (CCDs) coupled to scintillation crystals can be used for high-resolution imaging with x-rays and gamma rays. When the CCD images can be read out fast enough, the energy and interaction position of individual gamma quanta can be estimated by a real-time image analysis of the scintillation light f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/8/N01

    authors: Heemskerk JW,Westra AH,Linotte PM,Ligtvoet KM,Zbijewski W,Beekman FJ

    更新日期:2007-04-21 00:00:00

  • Experimental determination of pCo perturbation factors for plane-parallel chambers.

    abstract::For plane-parallel chambers used in electron dosimetry, modern dosimetry protocols recommend a cross-calibration against a calibrated cylindrical chamber. The rationale for this is the unacceptably large (up to 3-4%) chamber-to-chamber variations of the perturbation factors (pwall)Co, which have been reported for plan...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,多中心研究

    doi:10.1088/0031-9155/52/23/026

    authors: Kapsch RP,Bruggmoser G,Christ G,Dohm OS,Hartmann GH,Schüle E

    更新日期:2007-12-07 00:00:00

  • Refraction-angle resolution of diffraction enhanced imaging.

    abstract::As a new method, x-ray diffraction enhanced imaging (DEI) has extremely high sensitivity for weakly absorbing low-Z samples in medical and biological fields. Conventional performance parameters, such as spatial resolution and low-contrast resolution, are not enough to describe the characteristics of a DEI system. This...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/12/002

    authors: Huang ZF,Kang KJ,Li Z

    更新日期:2006-06-21 00:00:00

  • Understanding the limitations of ultrasonic backscatter measurements from microbubble populations.

    abstract::Despite over ten years of in vitro investigations of ultrasound contrast agents, the level of understanding of their behaviour in ultrasound fields is limited. Several problems associated with these investigations, particular to the nature of contrast agents, are discussed. Using a commercial scanner the RF normalized...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/23/313

    authors: Sboros V,Ramnarine KV,Moran CM,Pye SD,McDicken WN

    更新日期:2002-12-07 00:00:00

  • On the accuracy and effectiveness of dose reconstruction for tomotherapy.

    abstract::Dose reconstruction is a process that re-creates the treatment-time dose deposited in a patient provided there is knowledge of the delivered energy fluence and the patient's anatomy at the time of treatment. A method for reconstructing dose is presented. The process starts with delivery verification, in which the inci...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/4/303

    authors: Kapatoes JM,Olivera GH,Balog JP,Keller H,Reckwerdt PJ,Mackie TR

    更新日期:2001-04-01 00:00:00

  • An extended diffraction-enhanced imaging method for implementing multiple-image radiography.

    abstract::Diffraction-enhanced imaging (DEI) is an analyser-based x-ray imaging method that produces separate images depicting the projected x-ray absorption and refractive properties of an object. Because the imaging model of DEI does not account for ultra-small-angle x-ray scattering (USAXS), the images produced in DEI can co...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/7/011

    authors: Chou CY,Anastasio MA,Brankov JG,Wernick MN,Brey EM,Connor DM,Zhong Z

    更新日期:2007-04-07 00:00:00

  • Assessment of the effects of pixel loss on image quality in direct digital radiography.

    abstract::Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitive image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE)...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/6/008

    authors: Padgett R,Kotre CJ

    更新日期:2004-03-21 00:00:00

  • Chemically tuned linear energy transfer dependent quenching in a deformable, radiochromic 3D dosimeter.

    abstract::Most solid-state detectors, including 3D dosimeters, show lower signal in the Bragg peak than expected, a process termed quenching. The purpose of this study was to investigate how variation in chemical composition of a recently developed radiochromic, silicone-based 3D dosimeter influences the observed quenching in p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa512a

    authors: Høye EM,Skyt PS,Balling P,Muren LP,Taasti VT,Swakoń J,Mierzwińska G,Rydygier M,Bassler N,Petersen JB

    更新日期:2017-02-21 00:00:00

  • A robust optimization method for weighted-layer-stacking proton beam therapy.

    abstract::The layer-stacking method can provide three-dimensional conformal dose distributions to the target based on a passive scattering method using mini-spread-out Bragg peak (SOBP). The purpose of this work is to demonstrate the effectiveness of a new weight optimization algorithm that can enhance the robustness of dose di...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9efd

    authors: Sakamoto Y,Maeda Y,Yamada Y,Ikeda M,Tameshige Y,Sasaki M,Shibata S,Yamamoto K

    更新日期:2020-09-28 00:00:00

  • K x-ray fluorescence measurements of bone lead concentration: the analysis of low-level data.

    abstract::K line x-ray fluorescence (KXRF) measurements of bone lead have emerged as a promising new biological marker of internal lead dose in epidemiological studies. Some disagreements exist, however, over the analysis of data at low levels of bone lead concentration. In this study, we performed 30 serial measurements on eac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/9/007

    authors: Kim R,Aro A,Rotnitzky A,Amarasiriwardena C,Hu H

    更新日期:1995-09-01 00:00:00

  • Modeling late rectal toxicities based on a parameterized representation of the 3D dose distribution.

    abstract::Many models exist for predicting toxicities based on dose-volume histograms (DVHs) or dose-surface histograms (DSHs). This approach has several drawbacks as firstly the reduction of the dose distribution to a histogram results in the loss of spatial information and secondly the bins of the histograms are highly correl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/7/013

    authors: Buettner F,Gulliford SL,Webb S,Partridge M

    更新日期:2011-04-07 00:00:00

  • The reproducibility of polyacrylamide gel dosimetry applied to stereotactic conformal radiotherapy.

    abstract::The reproducibility of polyacrylamide gel (PAG) dosimetry has been evaluated when used to verify two radiotherapy treatment plans of increasing complexity. The plans investigated were a three-field coplanar arrangement, using the linac jaws for field shaping, and a four-field, conformal, non-coplanar plan using precis...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/5/309

    authors: Cosgrove VP,Murphy PS,McJury M,Adams EJ,Warrington AP,Leach MO,Webb S

    更新日期:2000-05-01 00:00:00

  • Potential for reducing the numbers of SiPM readout surfaces of laser-processed X'tal cube PET detectors.

    abstract::We are developing a three-dimensional (3D) position-sensitive detector with isotropic spatial resolution, the X'tal cube. Originally, our design consisted of a crystal block for which all six surfaces were covered with arrays of multi-pixel photon counters (MPPCs). In this paper, we examined the feasibility of reducin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/5/1361

    authors: Hirano Y,Inadama N,Yoshida E,Nishikido F,Murayama H,Watanabe M,Yamaya T

    更新日期:2013-03-07 00:00:00

  • Comparison study of temporal regularization methods for fully 5D reconstruction of cardiac gated dynamic SPECT.

    abstract::Temporal regularization plays a critical role in cardiac gated dynamic SPECT reconstruction, of which the goal is to obtain an image sequence from a single acquisition which simultaneously shows both cardiac motion and tracer distribution change over the course of imaging (termed 5D). In our recent work, we explored t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/17/5523

    authors: Niu X,Yang Y,King MA

    更新日期:2012-09-07 00:00:00

  • Simulation study of the second-generation MR-compatible SPECT system based on the inverted compound-eye gamma camera design.

    abstract::In this paper, we present simulation studies for the second-generation MRI compatible SPECT system, MRC-SPECT-II, based on an inverted compound eye (ICE) gamma camera concept. The MRC-SPECT-II system consists of a total of 1536 independent micro-pinhole-camera-elements (MCEs) distributed in a ring with an inner diamet...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa4fb

    authors: Lai X,Meng LJ

    更新日期:2018-02-12 00:00:00

  • Delivery time comparison for intensity-modulated radiation therapy with/without flattening filter: a planning study.

    abstract::The treatment delivery time of intensity-modulated radiation therapy (IMRT) with a multileaf collimator (MLC) is generally longer than that of conventional radiotherapy. In theory, removing the flattening filter from the treatment head may reduce the beam-on time by enhancing the output dose rate, and then reduce the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/8/011

    authors: Fu W,Dai J,Hu Y,Han D,Song Y

    更新日期:2004-04-21 00:00:00

  • An investigation of automatic exposure control calibration for chest imaging with a computed radiography system.

    abstract::The purpose of this study was to examine the use of three physical image quality metrics in the calibration of an automatic exposure control (AEC) device for chest radiography with a computed radiography (CR) imaging system. The metrics assessed were signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and mean ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/9/2307

    authors: Moore CS,Wood TJ,Avery G,Balcam S,Needler L,Beavis AW,Saunderson JR

    更新日期:2014-05-07 00:00:00

  • An absorptiometry method for the determination of arterial blood concentration of injected iodinated contrast agent.

    abstract::A single photon absorptiometry method to measure the arterial concentration of injected iodinated contrast agent was developed. A prototype absorptiometry unit was built which consists of either a square or circular cross section acrylic (polymethylmethacrylate) cuvette connected to an arterial catheter at one end and...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/9/002

    authors: Yeung WT,Lee TY,Del Maestro RF,Kozak R,Bennett JD,Brown T

    更新日期:1992-09-01 00:00:00

  • Clinical ultraviolet dosimetry with a CCD monochromator array spectroradiometer.

    abstract::Single monochromator charge-coupled device (CCD) array spectroradiometers have the advantage of ease of use and speed compared with double grating instruments. Their inherently inferior stray-light rejection, however, can critically affect their accuracy in phototherapy and research-related dosimetry applications. Thi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/18/026

    authors: Coleman A,Sarkany R,Walker S

    更新日期:2008-09-21 00:00:00

  • Image quality improvements of electronic portal imaging devices by multi-level gain calibration and temperature correction.

    abstract::Amorphous silicon (aSi:H) flat panel detectors are prevalent in radiotherapy for megavoltage imaging tasks. Any clinical and dosimetrical application requires a well-defined dose response of the system to achieve meaningful results. Due to radiation damages, panels deteriorate and the linearity of pixel response to do...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/18/6429

    authors: Huber S,Mooslechner M,Mitterlechner B,Weichenberger H,Serpa M,Sedlmayer F,Deutschmann H

    更新日期:2013-09-21 00:00:00

  • Volumetric CT with sparse detector arrays (and application to Si-strip photon counters).

    abstract::Novel x-ray medical imaging sensors, such as photon counting detectors (PCDs) and large area CCD and CMOS cameras can involve irregular and/or sparse sampling of the detector plane. Application of such detectors to CT involves undersampling that is markedly different from the commonly considered case of sparse angular...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/1/90

    authors: Sisniega A,Zbijewski W,Stayman JW,Xu J,Taguchi K,Fredenberg E,Lundqvist M,Siewerdsen JH

    更新日期:2016-01-07 00:00:00

  • High-resolution numerical model of the middle and inner ear for a detailed analysis of radio frequency absorption.

    abstract::In order to enable a detailed analysis of radio frequency (RF) absorption in the human middle and inner ear organs, a numerical model of these organs was developed at a spatial resolution of 0.1 mm, based on a real human tissue sample. The dielectric properties of the liquids (perilymph and endolymph) inside the bony ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/7/001

    authors: Schmid G,Uberbacher R,Samaras T,Jappel A,Baumgartner WD,Tschabitscher M,Mazal PR

    更新日期:2007-04-07 00:00:00

  • Prediction of dose-volume histograms in nasopharyngeal cancer IMRT using geometric and dosimetric information.

    abstract::A method using both patient geometric and dosimetric information was proposed to predict dose-volume histograms (DVHs) of organs at risk (OARs) for a nasopharyngeal cancer (NPC) intensity-modulated radiation therapy (IMRT) plan. A total of 106 nine-field IMRT NPC plans were used in this study. Twenty-six plans were ra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab50eb

    authors: Jiao SX,Chen LX,Zhu JH,Wang ML,Liu XW

    更新日期:2019-12-05 00:00:00

  • Dosimetric evaluation of a 2D pixel ionization chamber for implementation in clinical routine.

    abstract::In this paper we present the results of a dosimetric evaluation of a 2D ionization chamber array with the objective of its implementation for quality assurance in clinical routine. The pixel ionization chamber MatriXX (Scanditronix Wellhofer, Germany) consists of 32x32 chambers with a distance of 7.6 mm between chambe...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/4/023

    authors: Herzen J,Todorovic M,Cremers F,Platz V,Albers D,Bartels A,Schmidt R

    更新日期:2007-02-21 00:00:00

  • Single patient convolutional neural networks for real-time MR reconstruction: a proof of concept application in lung tumor segmentation for adaptive radiotherapy.

    abstract::Investigate 3D (spatial and temporal) convolutional neural networks (CNNs) for real-time on-the-fly magnetic resonance imaging (MRI) reconstruction. In particular, we investigated the applicability of training CNNs on a patient-by-patient basis for the purpose of lung tumor segmentation. Data were acquired with our 3 ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab408e

    authors: Dietz B,Yun J,Yip E,Gabos Z,Fallone BG,Wachowicz K

    更新日期:2019-09-23 00:00:00

  • A novel single-ended readout depth-of-interaction PET detector fabricated using sub-surface laser engraving.

    abstract::We propose a novel scintillation detector design for positron emission tomography (PET), which has depth of interaction (DOI) capability and uses a single-ended readout scheme. The DOI detector contains a pair of crystal bars segmented using sub-surface laser engraving (SSLE). The two crystal bars are optically couple...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/18/6635

    authors: Uchida H,Sakai T,Yamauchi H,Hakamata K,Shimizu K,Yamashita T

    更新日期:2016-09-21 00:00:00