The reproducibility of polyacrylamide gel dosimetry applied to stereotactic conformal radiotherapy.

Abstract:

:The reproducibility of polyacrylamide gel (PAG) dosimetry has been evaluated when used to verify two radiotherapy treatment plans of increasing complexity. The plans investigated were a three-field coplanar arrangement, using the linac jaws for field shaping, and a four-field, conformal, non-coplanar plan using precision-cast lead alloy shielding blocks. Each treatment was performed three times using phantoms and calibration gels manufactured in-house. Two phantoms were specially designed for this work to aid accurate positioning of the gels for irradiation and imaging. All gels were imaged post-irradiation using a Siemens Vision 1.5T MR scanner. T2 relaxation images were calibrated to absorbed dose distributions using a number of smaller calibration vessels to produce distribution maps of relative dose. The relative dose distributions were found to be reproducible, with the standard deviation on the mean areas enclosed by the > or = 50% isodose lines measured in three orthogonal planes being 6.4% and 4.1% for the coplanar and non-coplanar plans respectively. The measured distributions were also consistent with those planned, with isodose lines generally agreeing to within a few millimetres. However, the measured absolute doses were on average 23.5% higher than those planned. Although the polyacrylamide gel dosimetry technique has some limitations, particularly when calibrating distributions to absolute dose, the ability to resolve sharp dose gradients in three dimensions with millimetre precision is invaluable when verifying complex conformal treatment plans, where avoidance of proximal, critical structures is a treatment criterion.

journal_name

Phys Med Biol

authors

Cosgrove VP,Murphy PS,McJury M,Adams EJ,Warrington AP,Leach MO,Webb S

doi

10.1088/0031-9155/45/5/309

subject

Has Abstract

pub_date

2000-05-01 00:00:00

pages

1195-210

issue

5

eissn

0031-9155

issn

1361-6560

journal_volume

45

pub_type

杂志文章
  • Modelling infrared temperature measurements: implications for laser irradiation and cryogen cooling studies.

    abstract::The use of thermographic techniques has increased as infrared detector technology has evolved and improved. For laser-tissue interactions, thermal cameras have been used to monitor the thermal response of tissue to pulsed and continuous wave irradiation. It is important to note that the temperature indicated by the th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/2/319

    authors: Choi B,Pearce JA,Welch AJ

    更新日期:2000-02-01 00:00:00

  • A motion-incorporated reconstruction method for gated PET studies.

    abstract::Cardiac and respiratory motion artefacts in PET imaging have been traditionally resolved by acquiring the data in gated mode. However, gated PET images are usually characterized by high noise content due to their low photon statistics. In this paper, we present a novel 4D model for the PET imaging system, which can in...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/15/012

    authors: Qiao F,Pan T,Clark JW Jr,Mawlawi OR

    更新日期:2006-08-07 00:00:00

  • The replacement correction factors for cylindrical chambers in high-energy photon beams.

    abstract::The values of the replacement correction factors (P(repl), or in the IAEA's notation p(dis)p(cav)) used for cylindrical chambers in high-energy photon beams represent one of the most significant differences between the AAPM and the IAEA dosimetry protocols. In a previous study (Wang L L W and Rogers D W O 2008 Med. Ph...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/6/014

    authors: Wang LL,Rogers DW

    更新日期:2009-03-21 00:00:00

  • A diffusion theory model of spatially resolved fluorescence from depth-dependent fluorophore concentrations.

    abstract::A photon diffusion model has been developed to calculate the steady-state spatially resolved fluorescence from pencil beam excitation in layered tissue. The model allows the calculation of both the excitation reflectance and the fluorescence escape for an arbitrary continuous depth distribution of tissue optical prope...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/2/307

    authors: Hyde DE,Farrell TJ,Patterson MS,Wilson BC

    更新日期:2001-02-01 00:00:00

  • Dosimetry for the MRI accelerator: the impact of a magnetic field on the response of a Farmer NE2571 ionization chamber.

    abstract::The UMC Utrecht is constructing a 1.5 T MRI scanner integrated with a linear accelerator (Lagendijk et al 2008 Radiother. Oncol. 86 25-9). The goal of this device is to facilitate soft-tissue contrast based image-guided radiotherapy, in order to escalate the dose to the tumour while sparing surrounding normal tissues....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/10/002

    authors: Meijsing I,Raaymakers BW,Raaijmakers AJ,Kok JG,Hogeweg L,Liu B,Lagendijk JJ

    更新日期:2009-05-21 00:00:00

  • The unique determination of the primary current by MEG and EEG.

    abstract::In this paper, we use a more realistic head model with ovoid geometry for approximation of a human head. By inverting the Geselowitz equation, some analytic results on the inverse MEG problem are presented in homogenous ovoid geometry. On one hand, some information about the components of primary current is shown by t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/21/012

    authors: Peng L,Cheng J,Jin L

    更新日期:2006-11-07 00:00:00

  • The consequences of fixed-pattern noise and image movement on electronic portal images.

    abstract::Fixed-pattern noise in electronic portal images (EPIs) is normally eliminated by dividing raw image data by an open-field calibration image (OFCI). However, for successful elimination, there must be exact registration between the two image sets. Any movement within the imaging system, such as that which occurs with ga...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/11/007

    authors: Kirby MC

    更新日期:1996-11-01 00:00:00

  • The influence of penetrating radiation on collimator performance.

    abstract::Geometric and penetration responses of a multihole focusing collimator to a point source have been determined using a digital computer and a ray tracing technique. Results are presented as point and line spread functions for collimated rays and penetrating rays, and as plane sensitivities and modulation transfer funct...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/26/1/011

    authors: Jahns MJ

    更新日期:1981-01-01 00:00:00

  • In vivo real-time cavitation imaging in moving organs.

    abstract::The stochastic nature of cavitation implies visualization of the cavitation cloud in real-time and in a discriminative manner for the safe use of focused ultrasound therapy. This visualization is sometimes possible with standard echography, but it strongly depends on the quality of the scanner, and is hindered by diff...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa4fe8

    authors: Arnal B,Baranger J,Demene C,Tanter M,Pernot M

    更新日期:2017-02-07 00:00:00

  • The electromagnetic response of human skin in the millimetre and submillimetre wave range.

    abstract::Recent studies of the minute morphology of the skin by optical coherence tomography revealed that the sweat ducts in human skin are helically shaped tubes, filled with a conductive aqueous solution. This, together with the fact that the dielectric permittivity of the dermis is higher than that of the epidermis, brings...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/11/005

    authors: Feldman Y,Puzenko A,Ben Ishai P,Caduff A,Davidovich I,Sakran F,Agranat AJ

    更新日期:2009-06-07 00:00:00

  • Analytical propagation of errors in dynamic SPECT: estimators, degrading factors, bias and noise.

    abstract::Dynamic SPECT is a relatively new technique that may potentially benefit many imaging applications. Though similar to dynamic PET, the accuracy and precision of dynamic SPECT parameter estimates are degraded by factors that differ from those encountered in PET. In this work we formulate a methodology for analytically ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/8/311

    authors: Kadrmas DJ,DiBella EV,Huesman RH,Gullberg GT

    更新日期:1999-08-01 00:00:00

  • The dosimetry for a coronary artery stent coated with radioactive 188Re and 32P.

    abstract::Radiation dose distributions have been calculated for 188Re and 32P activity on a coronary artery stent. The doses have been calculated both as a function of position along the stent and of depth into the artery wall. Comparisons of the dose from identical activities of 188Re and 32P on the stent show that the major d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/12/310

    authors: Fox RA,Henson PW

    更新日期:2000-12-01 00:00:00

  • The sliding slit test for dynamic IMRT: a useful tool for adjustment of MLC related parameters.

    abstract::For treatments with dynamic intensity modulated radiotherapy (IMRT), the adjustment of multileaf collimator (MLC) parameters affecting both the optimization algorithm and dose distributions is crucial. The main parameters characterizing the MLC are the transmission (T) and the dosimetric leaf separation (DLS). The aim...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/4/001

    authors: Chauvet I,Petitfils A,Lehobey C,Kristner JY,Brunet Y,Lembrez R,Gaboriaud G,Mazal A,Zefkili S,Rosenwald JC

    更新日期:2005-02-21 00:00:00

  • Fast online Monte Carlo-based IMRT planning for the MRI linear accelerator.

    abstract::The MRI accelerator, a combination of a 6 MV linear accelerator with a 1.5 T MRI, facilitates continuous patient anatomy updates regarding translations, rotations and deformations of targets and organs at risk. Accounting for these demands high speed, online intensity-modulated radiotherapy (IMRT) re-optimization. In ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/5/1375

    authors: Bol GH,Hissoiny S,Lagendijk JJ,Raaymakers BW

    更新日期:2012-03-07 00:00:00

  • Improving source detection and separation in a spatiotemporal Bayesian inference dipole analysis.

    abstract::Most existing spatiotemporal multi-dipole approaches for MEG/EEG source localization assume that the dipoles are active for the full time range being analysed. If the actual time range of activity of sources is significantly shorter than the time range being analysed, the detectability, localization and time-course de...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/10/004

    authors: Jun SC,George JS,Plis SM,Ranken DM,Schmidt DM,Wood CC

    更新日期:2006-05-21 00:00:00

  • Monte Carlo verification of polymer gel dosimetry applied to radionuclide therapy: a phantom study.

    abstract::This study evaluates the dosimetric performance of the polymer gel dosimeter 'Methacrylic and Ascorbic acid in Gelatin, initiated by Copper' and its suitability for quality assurance and analysis of I-131-targeted radionuclide therapy dosimetry. Four batches of gel were manufactured in-house and sets of calibration vi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/22/017

    authors: Gear JI,Charles-Edwards E,Partridge M,Flux GD

    更新日期:2011-11-21 00:00:00

  • A control systems approach for the simulation of renal dynamic software phantoms for nuclear medicine.

    abstract::For renal dynamic studies, the COST B2 hybrid phantom is an example of an artificially created software phantom. Although this phantom is useful, it is not possible to implement the phantom in a self-consistent fashion to produce, for example, a collection of tracer in the bladder which is related to the flow from the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/2/008

    authors: Houston AS,Sampson WF,Jose RM,Boyce JF

    更新日期:1999-02-01 00:00:00

  • Impact of attenuation correction strategies on the quantification of High Resolution Research Tomograph PET studies.

    abstract::In this study, the quantitative accuracy of different attenuation correction strategies presently available for the High Resolution Research Tomograph (HRRT) was investigated. These attenuation correction methods differ in reconstruction and processing (segmentation) algorithms used for generating a micro-image from m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/1/007

    authors: van Velden FH,Kloet RW,van Berckel BN,Molthoff CF,de Jong HW,Lammertsma AA,Boellaard R

    更新日期:2008-01-07 00:00:00

  • Correction of proton resonance frequency shift temperature maps for magnetic field disturbances caused by breathing.

    abstract::Respiratory induced resonance offset (RIRO) is a periodic disturbance of a magnetic field due to breathing. Such disturbance handicaps the accuracy of the proton resonance frequency shift (PRFS) method of MRI temperature mapping in anatomies situated nearby the lungs and chest wall. In this work, we propose a method c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/18/015

    authors: Shmatukha AV,Bakker CJ

    更新日期:2006-09-21 00:00:00

  • Two-dimensional and quasi-three-dimensional dosimetry of hadron and photon beams with the Magic Cube and the Pixel Ionization Chamber.

    abstract::Two detectors for fast two-dimensional (2D) and quasi-three-dimensional (quasi-3D) verification of the dose delivered by radiotherapy beams have been developed at University and Istituto Nazionale di Fisica Nucleare (INFN) of Torino. The Magic Cube is a stack of strip-segmented ionization chambers interleaved with wat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/16/017

    authors: Cirio R,Garelli E,Schulte R,Amerio S,Boriano A,Bourhaleb F,Coutrakon G,Donetti M,Giordanengo S,Koss P,Madon E,Marchetto F,Nastasi U,Peroni C,Santuari D,Sardo A,Scielzo G,Stasi M,Trevisiol E

    更新日期:2004-08-21 00:00:00

  • Numerical calculation of energy deposition by broad high-energy electron beams.

    abstract::The feasibility is demonstrated of a numerical method to calculate dose deposition by broad high-energy electron beams in homogeneous matter or in heterogeneous matter in which the heterogeneities are arranged in slabs perpendicular to the beam axis. The method is based only on the basic physical interaction processes...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/10/003

    authors: Huizenga H,Storchi PR

    更新日期:1989-10-01 00:00:00

  • An in silico framework to analyze the anisotropic shear wave mechanics in cardiac shear wave elastography.

    abstract::Shear wave elastography (SWE) is a potential tool to non-invasively assess cardiac muscle stiffness. This study focused on the effect of the orthotropic material properties and mechanical loading on the performance of cardiac SWE, as it is known that these factors contribute to complex 3D anisotropic shear wave propag...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaaffe

    authors: Caenen A,Pernot M,Peirlinck M,Mertens L,Swillens A,Segers P

    更新日期:2018-03-23 00:00:00

  • The use of a realistic VMAT delivery emulator to optimize dynamic machine parameters for improved treatment efficiency.

    abstract::The delivery of volumetric modulated arc therapy (VMAT) requires the simultaneous movement of the linear accelerator gantry, multi-leaf collimators and jaws while the dose rate is varied. In this study, a VMAT delivery emulator was developed to accurately predict the characteristics of a given treatment plan, incorpor...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/13/024

    authors: Boylan CJ,Rowbottom CG,Mackay RI

    更新日期:2011-07-07 00:00:00

  • Variation of the dielectric properties of tissues with age: the effect on the values of SAR in children when exposed to walkie-talkie devices.

    abstract::In vitro dielectric properties of ageing porcine tissues were measured in the frequency range of 50 MHz-20 GHz, and the total combined uncertainties of the measurements were assessed. The results show statistically significant reduction with age in both permittivity and conductivity of 10 out of 15 measured tissues. A...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/2/004

    authors: Peyman A,Gabriel C,Grant EH,Vermeeren G,Martens L

    更新日期:2009-01-21 00:00:00

  • Systematic investigation of the signal properties of polycrystalline HgI2 detectors under mammographic, radiographic, fluoroscopic and radiotherapy irradiation conditions.

    abstract::The signal properties of polycrystalline mercuric iodide (HgI2) film detectors, under irradiation conditions relevant to mammographic, radiographic, fluoroscopic and radiotherapy x-ray imaging, are reported. Each film detector consists of an approximately 230 to approximately 460 microm thick layer of HgI2 (fabricated...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/12/012

    authors: Su Z,Antonuk LE,El-Mohri Y,Hu L,Du H,Sawant A,Li Y,Wang Y,Yamamoto J,Zhao Q

    更新日期:2005-06-21 00:00:00

  • Evaluation of 209At as a theranostic isotope for 209At-radiopharmaceutical development using high-energy SPECT.

    abstract::The development of alpha-emitting radiopharmaceuticals using 211At requires quantitative determination of the time-dependent nature of the 211At biodistribution. However, imaging-based methods for acquiring this information with 211At have not found wide-spread use because of its low abundance of decay emissions suita...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaaa95

    authors: Crawford JR,Robertson AKH,Yang H,Rodríguez-Rodríguez C,Esquinas PL,Kunz P,Blinder S,Sossi V,Schaffer P,Ruth TJ

    更新日期:2018-02-21 00:00:00

  • Accurate Monte Carlo calculations of the combined attenuation and build-up factors, for energies (20-1500 keV) and distances (0-10 cm) relevant in brachytherapy.

    abstract::The combined build-up and attenuation factor, B exp (-mu r), of point isotropic photon sources in a water medium has been calculated using the Monte Carlo method, for energies (20-1500 keV) and distances (1-10 cm) relevant in brachytherapy. For the transport of photons and electrons, up-to-date and self-consistent tot...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/6/005

    authors: Angelopoulos A,Perris A,Sakellariou K,Sakelliou L,Sarigiannis K,Zarris G

    更新日期:1991-06-01 00:00:00

  • A preclinical simulated dataset of S-values and investigation of the impact of rescaled organ masses using the MOBY phantom.

    abstract::Nuclear medicine and radiation therapy, although well established, are still rapidly evolving, by exploiting animal models, aiming to define precise dosimetry in molecular imaging protocols. The purpose of the present study was to create a dataset based on the MOBY phantom for the calculation of organ-to-organ S-value...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/6/2333

    authors: Kostou T,Papadimitroulas P,Loudos G,Kagadis GC

    更新日期:2016-03-21 00:00:00

  • A spectral approach to ultrasonic scattering from human tissue: methods, objectives and backscattering measurements.

    abstract::The dearth of information on the physical processes involved in the propagation of ultrasound in tissue and the growing need for such information are discussed. The physical nature of the ultrasonic diagnostic process in considered in terms of a wave phenomenon and the limitations and advantages of frequency spectral ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/20/5/009

    authors: Chivers RC,Hill CR

    更新日期:1975-09-01 00:00:00

  • Characterization of a preclinical PET insert in a 7 Tesla MRI scanner: beyond NEMA testing.

    abstract::This study evaluates the performance of the Bruker positron emission tomograph (PET) insert combined with a BioSpec 70/30 USR magnetic resonance imaging (MRI) scanner using the manufacturer acceptance protocol and the NEMA NU 4-2008 for small animal PET. The PET insert is made of 3 rings of 8 monolithic LYSO crystals ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aba08c

    authors: Gsell W,Molinos C,Correcher C,Belderbos S,Wouters J,Junge S,Heidenreich M,Vande Velde G,Rezaei A,Nuyts J,Cawthorne C,Cleeren F,Nannan L,Deroose CM,Himmelreich U,González Martínez AJ

    更新日期:2020-06-26 00:00:00