:Dose reconstruction is a process that re-creates the treatment-time dose deposited in a patient provided there is knowledge of the delivered energy fluence and the patient's anatomy at the time of treatment. A method for reconstructing dose is presented. The process starts with delivery verification, in which the incident energy fluence from a treatment is computed using the exit detector signal and a transfer matrix to convert the detector signal to energy fluence. With the verified energy fluence and a CT image of the patient in the treatment position, the treatment-time dose distribution is computed using any model-based algorithm such as convolution/superposition or Monte Carlo. The accuracy of dose reconstruction and the ability of the process to reveal delivery errors are presented. Regarding accuracy, a reconstructed dose distribution was compared with a measured film distribution for a simulated breast treatment carried out on a thorax phantom. It was found that the reconstructed dose distribution agreed well with the dose distribution measured using film: the majority of the voxels were within the low and high dose-gradient tolerances of 3% and 3 mm respectively. Concerning delivery errors, it was found that errors associated with the accelerator, the multileaf collimator and patient positioning might be detected in the verified energy fluence and are readily apparent in the reconstructed dose. For the cases in which errors appear in the reconstructed dose, the possibility for adaptive radiotherapy is discussed.
journal_name
Phys Med Bioljournal_title
Physics in medicine and biologyauthors
Kapatoes JM,Olivera GH,Balog JP,Keller H,Reckwerdt PJ,Mackie TRdoi
10.1088/0031-9155/46/4/303subject
Has Abstractpub_date
2001-04-01 00:00:00pages
943-66issue
4eissn
0031-9155issn
1361-6560journal_volume
46pub_type
杂志文章abstract::Kilo-voltage (KV) cone-beam computed tomography (CBCT) unit mounted onto a linear accelerator treatment system, often referred to as on-board imager (OBI), plays an increasingly important role in image-guided radiation therapy. While the FDK algorithm is currently used for reconstructing images from clinical OBI data,...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/12/4601
更新日期:2015-06-21 00:00:00
abstract::The purpose of this work was to validate GATE-based clinical scale absorbed dose calculations in nuclear medicine dosimetry. GATE (version 6.2) and MCNPX (version 2.7.a) were used to derive dosimetric parameters (absorbed fractions, specific absorbed fractions and S-values) for the reference female computational model...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/62/5/1885
更新日期:2017-03-07 00:00:00
abstract::The design and performance of a dosimetric system for the irradiation of thin biological samples with therapeutic proton beams is reported. Protons with initial energies between 40 MeV and 250 MeV are degraded with polystyrene blocks of variable thickness in order to place the sample, an aqueous layer of 10 microm thi...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/47/3/304
更新日期:2002-02-07 00:00:00
abstract::Respiratory research with mice using micro-computed tomography (micro-CT) has been predominantly hindered by the limited resolution and signal-to-noise ratio (SNR) as a result of respiratory motion artefacts. In this study, we develop a novel technique for capturing the lung microstructure in vivo using micro-CT, thro...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/51/23/008
更新日期:2006-12-07 00:00:00
abstract::An iterative Bayesian reconstruction algorithm for limited view angle tomography, or ectomography, based on the three-dimensional total variation (TV) norm has been developed. The TV norm has been described in the literature as a method for reducing noise in two-dimensional images while preserving edges, without intro...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/46/3/318
更新日期:2001-03-01 00:00:00
abstract::Beam hardening is inevitable due to the polychromatic X-ray spectrum and energy-dependent attenuation coefficients of materials, leading to the underestimation of artifacts arising from projection data, especially on metal regions. State-of-the-art research on beam-hardening artifacts is based on a numerical method th...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/abe026
更新日期:2021-01-26 00:00:00
abstract::We present a method to include robustness in a multi-criteria optimization (MCO) framework for intensity-modulated proton therapy (IMPT). The approach allows one to simultaneously explore the trade-off between different objectives as well as the trade-off between robustness and nominal plan quality. In MCO, a database...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/3/591
更新日期:2012-02-07 00:00:00
abstract::Results from dielectric studies on the freshwater fish Cyprinus carpio exposed to a sublethal concentration of sodium alkyl benzene sulphonate were compared with those from untreated control fish; recovery from the test solution was also checked. The influence of the anionic detergent on the intracellular matter of fi...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/29/5/005
更新日期:1984-05-01 00:00:00
abstract::With high-dose administration of (90)Y labeled antibodies, it is possible to image (90)Y without an admixture of (111)In. We have earlier shown that it is possible to perform quantitative (90)Y bremsstrahlung SPECT for dosimetry purposes with reasonable accuracy. However, whole-body (WB) activity quantification with t...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/19/014
更新日期:2009-10-07 00:00:00
abstract::A method to measure the detector-to-object distance from the images obtained with stationary high-spatial-resolution gamma-ray cameras for in vivo studies has been developed. It exploits the shift of the imaged object in the image plane, obtained at a certain tilt of the parallel-hole collimator. A linear dependence o...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/51/9/N04
更新日期:2006-05-07 00:00:00
abstract::The problem of fluorescence diffuse optical tomography consists in localizing fluorescent markers from near-infrared light measurements. Among the different available acquisition modalities, the time-resolved modality is expected to provide measurements of richer information content. To extract this information, the m...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/23/004
更新日期:2009-12-07 00:00:00
abstract::To calculate photon spectra for a 10 MV x-ray beam emitted by a medical linear accelerator, we performed numerical analysis using the aluminium transmission data obtained along the central axis of the beam under the narrow beam condition corresponding to a 3x3 cm2 field at a 100 cm distance from the source. We used th...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/2/014
更新日期:2007-01-21 00:00:00
abstract::The dosimetric measurement and modeling of small radiation treatment fields (<2 × 2 cm2) are difficult to perform and prone to error. Measurements of small fields are often adversely influenced by the properties of the detectors used to make them. The dosimetric properties of small fields have been difficult to accura...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/12/015
更新日期:2011-06-21 00:00:00
abstract::Contrast enhanced ultrasound (CEUS) and dynamic contrast enhanced ultrasound (DCE-US) can be used to provide information about the vasculature aiding diagnosis and monitoring of a number of pathologies including cancer. In the development of a CEUS imaging system, there are many choices to be made, such as whether to ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab13f2
更新日期:2019-04-23 00:00:00
abstract::A novel transmission detector (IBA Dosimetry, Germany) developed as an IMRT quality assurance tool, intended for in vivo patient dose measurements, is studied here. The goal of this investigation is to use Monte Carlo techniques to characterize treatment beam parameters in the presence of the detector and to compare t...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/4/020
更新日期:2011-02-21 00:00:00
abstract::Online adaptive radiation therapy (ART) based on real-time magnetic resonance imaging represents a paradigm-changing treatment scheme. However, conventional quality assurance (QA) methods based on phantom measurements are not feasible with the patient on the treatment couch. The purpose of this work is to develop a fa...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa6e38
更新日期:2017-06-21 00:00:00
abstract::The architecture of multi-layer imagers (MLIs) can be exploited to provide megavoltage spectral imaging (MVSPI) for specific imaging tasks. In the current work, we investigated bone suppression and gold fiducial contrast enhancement as two clinical tasks which could be improved with spectral imaging. A method based on...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aabe21
更新日期:2018-05-10 00:00:00
abstract::In this paper, we present a segmentation and classification method for thyroid follicular neoplasms based on a combination of the prior-based level set method and deep convolutional neural network. The proposed method aims to discriminate thyroid follicular adenoma (TFA) and follicular thyroid carcinoma (FTC) in ultra...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/abc6f2
更新日期:2020-11-02 00:00:00
abstract::This study evaluates the performance of the Bruker positron emission tomograph (PET) insert combined with a BioSpec 70/30 USR magnetic resonance imaging (MRI) scanner using the manufacturer acceptance protocol and the NEMA NU 4-2008 for small animal PET. The PET insert is made of 3 rings of 8 monolithic LYSO crystals ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aba08c
更新日期:2020-06-26 00:00:00
abstract::Backscatter factors for orthovoltage x-ray beams are fitted with the expression BSF = 1 + ms/(s + n), where s is field size and m and n are adjustable parameters. The accuracy is better than 0.5%. Good results were also obtained for Cs-137 gamma rays at depth 0.12 cm and Co-60 gamma rays at depth 0.5 cm using the same...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/43/5/021
更新日期:1998-05-01 00:00:00
abstract::Lymphedema is a common condition involving an abnormal accumulation of lymphatic fluid in the interstitial space that causes swelling, most often in the arm(s) and leg(s). Lymphedema is a significant lifelong concern that can be congenital or develop following cancer treatment or cancer metastasis. Common methods of e...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/21/013
更新日期:2007-11-07 00:00:00
abstract::Our newly developed method using spatially and time-resolved reflectances can easily estimate the absorption coefficients of each layer in a two-layered medium if the thickness of the upper layer and the reduced scattering coefficients of the two layers are known a priori. We experimentally validated this method using...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/16/014
更新日期:2009-08-21 00:00:00
abstract::The measured attenuation correction technique is widely used in cardiac positron tomographic studies. However, the success of this technique is limited because of insufficient counting statistics achievable in practical transmission scan times, and of the scattered radiation in transmission measurement which leads to ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/41/10/024
更新日期:1996-10-01 00:00:00
abstract::A detailed Monte Carlo model of a proton therapy treatment head was commissioned to simulate the delivery of small field proton treatments. Small fields are challenging in the planning and quality assurance process because of aperture scattering and dosimetric disequilibrium. Four patients with small fields used in al...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/24/003
更新日期:2010-12-21 00:00:00
abstract::A theoretical analysis is presented of the biologically effective dose of the solar long wave ultraviolet radiation (UVA) received by patients who are being treated for psoriasis by oral psoralen photochemotherapy. It is shown that patients treated during the summer months in the UK may well receive a UV dose which is...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/26/6/011
更新日期:1981-11-01 00:00:00
abstract::Our study aimed to quantitatively evaluate blood flow in the left ventricle (LV) of apical hypertrophic cardiomyopathy (APH) by combining wall thickness obtained from cardiac magnetic resonance imaging (MRI) and myocardial perfusion from single-photon emission computed tomography (SPECT). In this study, we considered ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/14/019
更新日期:2007-07-21 00:00:00
abstract::A special parallel-plate ionization chamber was developed. The motivation for the construction of this new chamber was mainly to fulfil the need of a reference system for computed tomography standard beams in the Calibration Laboratory of IPEN. However, the chamber was tested also in standard radiation beams of mammog...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/50/16/012
更新日期:2005-08-21 00:00:00
abstract::Monte Carlo (MC) algorithms are recognized as the most accurate methodology for patient dose assessment. For intensity-modulated radiation therapy (IMRT) delivered with dynamic multileaf collimators (DMLCs), accurate dose calculation, even with MC, is challenging. Accurate IMRT MC dose calculations require inclusion o...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/47/17/312
更新日期:2002-09-07 00:00:00
abstract::A three-dimensional spherical inclusion model that approximates a lesion bonded to a tissue matrix is proposed for biomedical elastography. Analytical formulae describing spatial strain and stress distributions generated in infinite media by uniform loading are given under a linear, homogeneous, isotropic elasticity a...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/43/1/001
更新日期:1998-01-01 00:00:00
abstract::A number of radiation-therapy-related uses based on a commercially available spreadsheet program have been developed at our facility. The graphics and display capabilities inherent in these spreadsheet programs allow for concise visual results. The spreadsheets are used as an independent check for several types of rad...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/40/6/007
更新日期:1995-06-01 00:00:00