A method for photon beam Monte Carlo multileaf collimator particle transport.

Abstract:

:Monte Carlo (MC) algorithms are recognized as the most accurate methodology for patient dose assessment. For intensity-modulated radiation therapy (IMRT) delivered with dynamic multileaf collimators (DMLCs), accurate dose calculation, even with MC, is challenging. Accurate IMRT MC dose calculations require inclusion of the moving MLC in the MC simulation. Due to its complex geometry, full transport through the MLC can be time consuming. The aim of this work was to develop an MLC model for photon beam MC IMRT dose computations. The basis of the MC MLC model is that the complex MLC geometry can be separated into simple geometric regions, each of which readily lends itself to simplified radiation transport. For photons, only attenuation and first Compton scatter interactions are considered. The amount of attenuation material an individual particle encounters while traversing the entire MLC is determined by adding the individual amounts from each of the simplified geometric regions. Compton scatter is sampled based upon the total thickness traversed. Pair production and electron interactions (scattering and bremsstrahlung) within the MLC are ignored. The MLC model was tested for 6 MV and 18 MV photon beams by comparing it with measurements and MC simulations that incorporate the full physics and geometry for fields blocked by the MLC and with measurements for fields with the maximum possible tongue-and-groove and tongue-or-groove effects, for static test cases and for sliding windows of various widths. The MLC model predicts the field size dependence of the MLC leakage radiation within 0.1% of the open-field dose. The entrance dose and beam hardening behind a closed MLC are predicted within +/- 1% or 1 mm. Dose undulations due to differences in inter- and intra-leaf leakage are also correctly predicted. The MC MLC model predicts leaf-edge tongue-and-groove dose effect within +/- 1% or 1 mm for 95% of the points compared at 6 MV and 88% of the points compared at 18 MV. The dose through a static leaf tip is also predicted generally within +/- 1% or 1 mm. Tests with sliding windows of various widths confirm the accuracy of the MLC model for dynamic delivery and indicate that accounting for a slight leaf position error (0.008 cm for our MLC) will improve the accuracy of the model. The MLC model developed is applicable to both dynamic MLC and segmental MLC IMRT beam delivery and will be useful for patient IMRT dose calculations, pre-treatment verification of IMRT delivery and IMRT portal dose transmission dosimetry.

journal_name

Phys Med Biol

authors

Siebers JV,Keall PJ,Kim JO,Mohan R

doi

10.1088/0031-9155/47/17/312

subject

Has Abstract

pub_date

2002-09-07 00:00:00

pages

3225-49

issue

17

eissn

0031-9155

issn

1361-6560

journal_volume

47

pub_type

杂志文章
  • Exploration of tradeoffs in intensity-modulated radiotherapy.

    abstract::The purpose of this study is to calculate Pareto surfaces in multi-criteria radiation treatment planning and to analyse the dependency of the Pareto surfaces on the objective functions used for the volumes of interest. We develop a linear approach that allows us to calculate truly Pareto optimal treatment plans, and w...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/24/007

    authors: Craft D,Halabi T,Bortfeld T

    更新日期:2005-12-21 00:00:00

  • Optical properties of porcine skin dermis between 900 nm and 1500 nm.

    abstract::The weak absorption of shortwave infrared light by skin tissues between 700 and 1500 nm offers an important window for diagnosis by optical means. The strong scattering of shortwave infrared light by the skin, however, presents a challenge to the modelling of light propagation through the skin and the understanding of...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/1/312

    authors: Du Y,Hu XH,Cariveau M,Ma X,Kalmus GW,Lu JQ

    更新日期:2001-01-01 00:00:00

  • The effective attenuation coefficient of soft tissue in the presence of Compton scattering from bone: experiments on models.

    abstract::Calibration methods are investigated for the determination of bone density by the Compton scattering method. The scattered radiation from materials of different densities and dimensions is measured for this purpose. A function for the dependence of the intensity on these parameters is derived and compared with the exp...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/4/009

    authors: Leichter I,Weinreb A,Hazan G

    更新日期:1980-07-01 00:00:00

  • Characterization of optical parameters with a human forearm at the region from 1.15 to 1.52 microm using diffuse reflectance measurements.

    abstract::Time- and space-resolved diffuse reflectance measurements were used to identify the optical parameters, the reduced scattering and absorption coefficients, of bulk living tissue in the region from 1.15 to 1.52 microm. Although in this region the detector was limited in its temporal resolution, we applied a peak-time s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/11/021

    authors: Nishimura G,Kida I,Tamura M

    更新日期:2006-06-07 00:00:00

  • Prediction of positron emitter distributions for range monitoring in carbon ion therapy: an analytical approach.

    abstract::Range verification is one of the most relevant tasks in ion beam therapy. In the case of carbon ion therapy, positron emission tomography (PET) is the most widely used method for this purpose, which images the [Formula: see text]-activation following nuclear interactions of the ions with the tissue nuclei. Since the p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab17f9

    authors: Hofmann T,Fochi A,Parodi K,Pinto M

    更新日期:2019-05-21 00:00:00

  • Sensitivity of different dose scoring methods on organ-specific neutron dose calculations in proton therapy.

    abstract::Scattered doses, e.g. neutron doses in proton therapy, are of concern in radiation therapy. Although measured data are the gold standard, Monte Carlo simulations allow a more realistic consideration of patient anatomy via whole-body phantoms. When calculating neutron doses with Monte Carlo techniques, the dose can be ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/17/004

    authors: Jarlskog CZ,Paganetti H

    更新日期:2008-09-07 00:00:00

  • A novel approach with dual-sampling convolutional neural network for ultrasound image classification of breast tumors.

    abstract::Breast cancer is one of the leading causes of female cancer deaths. Early diagnosis with prophylactic may improve the patients' prognosis. So far ultrasound (US) imaging is a popular method in breast cancer diagnosis. However, its accuracy is bounded to traditional handcrafted feature methods and expertise. A novel me...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abc5c7

    authors: Xie J,Song X,Zhang W,Dong Q,Wang Y,Li F,Wan C

    更新日期:2020-10-29 00:00:00

  • Effective energy resolution and scatter rejection in nuclear medicine.

    abstract::All available imaging devices in nuclear medicine have finite energy resolution. This leads to inclusion of scattered radiation, which in turn degrades the image quality. Different scatter correction schemes therefore try to eliminate the effect of scattered radiation. On the other hand, improvement of the camera's in...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/1/008

    authors: Wirth V

    更新日期:1989-01-01 00:00:00

  • The feasibility of using poroelastographic techniques for distinguishing between normal and lymphedematous tissues in vivo.

    abstract::Lymphedema is a common condition involving an abnormal accumulation of lymphatic fluid in the interstitial space that causes swelling, most often in the arm(s) and leg(s). Lymphedema is a significant lifelong concern that can be congenital or develop following cancer treatment or cancer metastasis. Common methods of e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/21/013

    authors: Righetti R,Garra BS,Mobbs LM,Kraemer-Chant CM,Ophir J,Krouskop TA

    更新日期:2007-11-07 00:00:00

  • Leveraging multi-layer imager detector design to improve low-dose performance for megavoltage cone-beam computed tomography.

    abstract::While megavoltage cone-beam computed tomography (CBCT) using an electronic portal imaging device (EPID) provides many advantages over kilovoltage (kV) CBCT, clinical adoption is limited by its high doses. Multi-layer imager (MLI) EPIDs increase DQE(0) while maintaining high resolution. However, even well-designed, hig...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa160

    authors: Hu YH,Rottmann J,Fueglistaller R,Myronakis M,Wang A,Huber P,Shedlock D,Morf D,Baturin P,Star-Lack J,Berbeco R

    更新日期:2018-01-30 00:00:00

  • Automated 3D ultrasound image analysis for first trimester assessment of fetal health.

    abstract::The first trimester fetal ultrasound scan is important to confirm fetal viability, to estimate the gestational age of the fetus, and to detect fetal anomalies early in pregnancy. First trimester ultrasound images have a different appearance than for the second trimester scan, reflecting the different stage of fetal de...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab3ad1

    authors: Ryou H,Yaqub M,Cavallaro A,Papageorghiou AT,Alison Noble J

    更新日期:2019-09-17 00:00:00

  • Intraventricular vector flow mapping-a Doppler-based regularized problem with automatic model selection.

    abstract::We propose a regularized least-squares method for reconstructing 2D velocity vector fields within the left ventricular cavity from single-view color Doppler echocardiographic images. Vector flow mapping is formulated as a quadratic optimization problem based on an [Formula: see text]-norm minimization of a cost functi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa7fe7

    authors: Assi KC,Gay E,Chnafa C,Mendez S,Nicoud F,Abascal JFPJ,Lantelme P,Tournoux F,Garcia D

    更新日期:2017-08-11 00:00:00

  • Dose-volume histogram prediction using density estimation.

    abstract::Knowledge of what dose-volume histograms can be expected for a previously unseen patient could increase consistency and quality in radiotherapy treatment planning. We propose a machine learning method that uses previous treatment plans to predict such dose-volume histograms. The key to the approach is the framing of d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/17/6923

    authors: Skarpman Munter J,Sjölund J

    更新日期:2015-09-07 00:00:00

  • A theoretical comparison of energy sources--microwave, ultrasound and laser--for interstitial thermal therapy.

    abstract::A number of heating sources are available for minimally invasive thermal therapy of tumours. The purpose of this work was to compare, theoretically, the heating characteristics of interstitial microwave, laser and ultrasound sources in three tissue sites: breast, brain and liver. Using a numerical method, the heating ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/12/011

    authors: Skinner MG,Iizuka MN,Kolios MC,Sherar MD

    更新日期:1998-12-01 00:00:00

  • Synchrotron microangiography with no contrast agent.

    abstract::Coherent x-rays from synchrotron sources are increasingly used in non-conventional radiological techniques ('phase-contrast' radiology). Our experiments demonstrate that by using white (unmonochromatic) radiation and a time-resolving system, it is possible to image microscopic details of moving blood vessels in differ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/4/002

    authors: Hwu Y,Tsai WL,Je JH,Seol SK,Kim B,Groso A,Margaritondo G,Lee KH,Seong JK

    更新日期:2004-02-21 00:00:00

  • Counting losses in multidetector radiation counters.

    abstract::We examined the reasons for the reduction in response of a multidetector radiation counting system when operated at high count-rates and established a convenient method of correction which is accurate to within +/- 1% up to 0-6 X 10(5) counts per second. In its application the method uses the observed count-rates from...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/21/1/009

    authors: Oxby CB,Oldroyd B,Appleby DB

    更新日期:1976-01-01 00:00:00

  • An investigation using atomic force microscopy nanoindentation of dental enamel demineralization as a function of undissociated acid concentration and differential buffer capacity.

    abstract::Acidic drinks and foodstuffs can demineralize dental hard tissues, leading to a pathological condition known as dental erosion, which is of increasing clinical concern. The first step in enamel dissolution is a demineralization of the outer few micrometres of tissue, which results in a softening of the structure. The ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/4/003

    authors: Barbour ME,Shellis RP

    更新日期:2007-02-21 00:00:00

  • NTCP modelling and pulmonary function tests evaluation for the prediction of radiation induced pneumonitis in non-small-cell lung cancer radiotherapy.

    abstract::This work aims to evaluate the predictive strength of the relative seriality, parallel and Lyman-Kutcher-Burman (LKB) normal tissue complication probability (NTCP) models regarding the incidence of radiation pneumonitis (RP), in a group of patients following lung cancer radiotherapy and also to examine their correlati...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/4/013

    authors: Tsougos I,Nilsson P,Theodorou K,Kjellén E,Ewers SB,Jarlman O,Lind BK,Kappas C,Mavroidis P

    更新日期:2007-02-21 00:00:00

  • Energy-resolved computed tomography: first experimental results.

    abstract::First experimental results with energy-resolved computed tomography (CT) are reported. The contrast-to-noise ratio (CNR) in CT has been improved with x-ray energy weighting for the first time. Further, x-ray energy weighting improved the CNR in material decomposition CT when applied to CT projections prior to dual-ene...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/20/002

    authors: Shikhaliev PM

    更新日期:2008-10-21 00:00:00

  • Quantification of the trabecular bone volume fraction for bone marrow dosimetry in molecular radiotherapy by using a dual-energy (SPECT/)CT.

    abstract::A complete characterization of spongiosa (bone marrow plus trabecular bone) is required to calculate the absorbed dose to active bone marrow. Due to the complex microanatomy, it is necessary to apply non-conventional imaging methods in nuclear medicine. The aim of this study is validating a phantomless quantification ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab4476

    authors: Salas-Ramirez M,Tran-Gia J,Gbureck U,Kosmala A,Lassmann M

    更新日期:2019-10-16 00:00:00

  • The integration of DVH-based planning aspects into a convex intensity modulated radiation therapy optimization framework.

    abstract::The formulation of intensity modulated radiation therapy (IMRT) planning aspects frequently uses the dose-volume histogram (DVH), whereas plan computations often happen in the more desirable convex IMRT optimization framework. Inspired by a recent publication of Zinchenko et al (2008 Phys. Med. Biol. 53 3231-50), this...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/12/N02

    authors: Kratt K,Scherrer A

    更新日期:2009-06-21 00:00:00

  • Numerical calculation of energy deposition by broad high-energy electron beams.

    abstract::The feasibility is demonstrated of a numerical method to calculate dose deposition by broad high-energy electron beams in homogeneous matter or in heterogeneous matter in which the heterogeneities are arranged in slabs perpendicular to the beam axis. The method is based only on the basic physical interaction processes...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/10/003

    authors: Huizenga H,Storchi PR

    更新日期:1989-10-01 00:00:00

  • Influence of source parameters on large-field electron beam profiles calculated using Monte Carlo methods.

    abstract::The purpose of this paper was to study the source model for a Monte Carlo simulation of electron beams from a medical linear accelerator. In a prior study, a non-divergent Gaussian source with a full-width at half-maximum (FWHM) of 0.15 cm was successful in predicting relative dose distributions for electron beams wit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/1/007

    authors: Weinberg R,Antolak JA,Starkschall G,Kudchadker RJ,White RA,Hogstrom KR

    更新日期:2009-01-07 00:00:00

  • Dose effect of guidewire position in intravascular brachytherapy.

    abstract::It has been reported that the dose effects of metallic guidewires are significant in intravascular brachytherapy (IVBT) using a beta source. The purpose of this work is to investigate the dependence of these dose effects on guidewire position. The EGS4 Monte Carlo codes were used to perform the dose calculations for t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/10/309

    authors: Shih R,Hsu WL,Li XA

    更新日期:2002-05-21 00:00:00

  • Extension of RPI-adult male and female computational phantoms to obese patients and a Monte Carlo study of the effect on CT imaging dose.

    abstract::Although it is known that obesity has a profound effect on x-ray computed tomography (CT) image quality and patient organ dose, quantitative data describing this relationship are not currently available. This study examines the effect of obesity on the calculated radiation dose to organs and tissues from CT using newl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/9/2441

    authors: Ding A,Mille MM,Liu T,Caracappa PF,Xu XG

    更新日期:2012-05-07 00:00:00

  • Construction of a biomechanical head and neck motion model as a guide to evaluation of deformable image registration.

    abstract::The use of deformable image registration methods in the context of adaptive radiotherapy leads to uncertainties in the simulation of the administered dose distributions during the treatment course. Evaluation of these methods is a prerequisite to decide if a plan adaptation will improve the individual treatment. Curre...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa69b6

    authors: Teske H,Bartelheimer K,Meis J,Bendl R,Stoiber EM,Giske K

    更新日期:2017-06-21 00:00:00

  • In vivo electric conductivity of cervical cancer patients based on B₁⁺ maps at 3T MRI.

    abstract::The in vivo electric conductivity (σ) values of tissue are essential for accurate electromagnetic simulations and specific absorption rate (SAR) assessment for applications such as thermal dose computations in hyperthermia. Currently used σ-values are mostly based on ex vivo measurements. In this study the conductivit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/4/1596

    authors: Balidemaj E,de Boer P,van Lier AL,Remis RF,Stalpers LJ,Westerveld GH,Nederveen AJ,van den Berg CA,Crezee J

    更新日期:2016-02-21 00:00:00

  • Stability analysis of a deterministic dose calculation for MRI-guided radiotherapy.

    abstract::Modern effort in radiotherapy to address the challenges of tumor localization and motion has led to the development of MRI guided radiotherapy technologies. Accurate dose calculations must properly account for the effects of the MRI magnetic fields. Previous work has investigated the accuracy of a deterministic linear...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa959a

    authors: Zelyak O,Fallone BG,St-Aubin J

    更新日期:2017-12-14 00:00:00

  • Recovery of total I-131 activity within focal volumes using SPECT and 3D OSEM.

    abstract::We experimentally investigated the SPECT recovery of I-131 activity in multiple spheres located simultaneously at different locations within a cylindrical phantom that had an elliptical cross section. The sphere volumes ranged from 209 cc down to 4.2 cc. A Prism 3000 camera and two types of parallel-hexagonal-hole col...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/3/017

    authors: Koral KF,Yendiki A,Dewaraja YK

    更新日期:2007-02-07 00:00:00

  • Direct determination of cone-beam geometric parameters using the helical phantom.

    abstract::Estimation of a set of parameters that describe the geometry of the cone-beam computed tomography system plays an important role in the geometrical calibration. In the calibration process, the helical phantom consisting of spherical markers arranged on a helical trajectory has been widely applied. To directly determin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/19/5667

    authors: Xu M,Zhang C,Liu X,Li D

    更新日期:2014-10-07 00:00:00