Influence of anisotropic compartments on magnetic field and electric potential distributions generated by artificial current dipoles inside a torso phantom.

Abstract:

:The purpose of this study is the analysis of the influence of anisotropic conductivity on magnetic fields and electric potentials by means of phantom measurements. An artificial rotating current dipole was placed in the middle of an anisotropic skein arrangement in a torso phantom filled with saline solution. The signal strength and the change of the shape of potential and field patterns due to anisotropic volume conduction were investigated. Different directions of the dipole were compared to corresponding orientations of measured fields and potentials (angle difference). For electric and magnetic data, the angle difference between observed signal orientations and true dipole orientations continuously increased with the angle between dipole and anisotropy (up to 80 degrees ) and then decreased back to zero at their orthogonal orientation. Both signal strengths decreased about 10% with an increasing angle between dipole and anisotropy. While the magnetic field showed a generally stronger shape change, the changed shape of the electric potential showed similarity to an extended source. Our phantom study demonstrated that anisotropic compartments influence directions, amplitudes and shapes of potentials and fields at different degrees. We concluded that anisotropic structures should be considered in volume conductor modelling, when source orientation, extension and strength are of interest.

journal_name

Phys Med Biol

authors

Liehr M,Haueisen J

doi

10.1088/0031-9155/53/1/017

subject

Has Abstract

pub_date

2008-01-07 00:00:00

pages

245-54

issue

1

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(08)58363-1

journal_volume

53

pub_type

杂志文章
  • Single patient convolutional neural networks for real-time MR reconstruction: a proof of concept application in lung tumor segmentation for adaptive radiotherapy.

    abstract::Investigate 3D (spatial and temporal) convolutional neural networks (CNNs) for real-time on-the-fly magnetic resonance imaging (MRI) reconstruction. In particular, we investigated the applicability of training CNNs on a patient-by-patient basis for the purpose of lung tumor segmentation. Data were acquired with our 3 ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab408e

    authors: Dietz B,Yun J,Yip E,Gabos Z,Fallone BG,Wachowicz K

    更新日期:2019-09-23 00:00:00

  • Physical mechanisms of gas and perfluoron retinopexy and sub-retinal fluid displacement.

    abstract::Injection of gas into the eye, followed by face-down positioning, is a common protocol for the reseating of the retina in posterior and superior retinal tears and breaks. The physical mechanism by which injected gas helps reattach retinal flaps is often ascribed to the 'buoyancy' force of the injected gas bubble. The ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/13/015

    authors: Foster WJ,Chou T

    更新日期:2004-07-07 00:00:00

  • Photon-counting spectral computed tomography using silicon strip detectors: a feasibility study.

    abstract::We show how the spectral imaging framework should be modified to account for a high fraction of Compton interactions in low Z detector materials such as silicon. Using this framework, where deposited energies differ from actual photon energies, we compare the performance of a silicon strip detector, including the infl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/7/014

    authors: Bornefalk H,Danielsson M

    更新日期:2010-04-07 00:00:00

  • Directional x-ray dark-field imaging.

    abstract::We introduce a novel x-ray imaging approach that yields information about the local texture of structures smaller than the image pixel resolution inside an object. The approach is based on a recently developed x-ray dark-field imaging technique, using scattering from sub-micron structures in the sample. We show that t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/12/004

    authors: Jensen TH,Bech M,Bunk O,Donath T,David C,Feidenhans'l R,Pfeiffer F

    更新日期:2010-06-21 00:00:00

  • An edge-on charge-transfer design for energy-resolved x-ray detection.

    abstract::As an x-ray beam goes through the human body, it will collect important information via interaction with tissues. Since this interaction is energy-sensitive, the state-of-the-art spectral CT technologies provide higher quality images of biological tissues with x-ray energy information (or spectral information). With e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/11/4183

    authors: Shi Z,Yang H,Cong W,Wang G

    更新日期:2016-06-07 00:00:00

  • Simulations of a micro-PET system based on liquid xenon.

    abstract::The imaging performance of a high-resolution preclinical micro-positron emission tomography (micro-PET) system employing liquid xenon (LXe) as the gamma-ray detection medium was simulated. The arrangement comprises a ring of detectors consisting of trapezoidal LXe time projection ionization chambers and two arrays of ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/6/1685

    authors: Miceli A,Glister J,Andreyev A,Bryman D,Kurchaninov L,Lu P,Muennich A,Retiere F,Sossi V

    更新日期:2012-03-21 00:00:00

  • A new treatment planning approach accounting for prompt gamma range verification and interfractional anatomical changes.

    abstract::Prompt gamma (PG) imaging is widely investigated for spot-by-spot in vivo range verification for proton therapy. Previous studies pointed out that the accuracy of prompt gamma imaging is affected by the statistics (number of protons delivered per pencil beam) of the proton beams and the conformity between prompt gamma...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab7d15

    authors: Tian L,Landry G,Dedes G,Pinto M,Kamp F,Belka C,Parodi K

    更新日期:2020-04-29 00:00:00

  • Calibration and analysis of a multimodal micro-CT and structured light imaging system for the evaluation of excised breast tissue.

    abstract::A multimodal micro-computed tomography (CT) and multi-spectral structured light imaging (SLI) system is introduced and systematically analyzed to test its feasibility to aid in margin delineation during breast conserving surgery (BCS). Phantom analysis of the micro-CT yielded a signal-to-noise ratio of 34, a contrast ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa94b6

    authors: McClatchy DM,Rizzo EJ,Meganck J,Kempner J,Vicory J,Wells WA,Paulsen KD,Pogue BW

    更新日期:2017-11-10 00:00:00

  • A 3D point-kernel multiple scatter model for parallel-beam SPECT based on a gamma-ray buildup factor.

    abstract::A three-dimensional (3D) point-kernel multiple scatter model for point spread function (PSF) determination in parallel-beam single-photon emission computed tomography (SPECT), based on a dose gamma-ray buildup factor, is proposed. This model embraces nonuniform attenuation in a voxelized object of imaging (patient bod...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/19/004

    authors: Marinkovic P,Ilic R,Spaic R

    更新日期:2007-10-07 00:00:00

  • Effect of microscopic modeling of skin in electrical and thermal analysis of transcranial direct current stimulation.

    abstract::Transcranial direct current stimulation (tDCS) is a neuromodulation scheme where a small current is delivered to the brain via two electrodes attached to the scalp. The electrode design is an important topic, not only as regards efficacy, but also from a safety perspective, as tDCS may be related to skin lesions that ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/61/24/8825

    authors: Gomez-Tames J,Sugiyama Y,Laakso I,Tanaka S,Koyama S,Sadato N,Hirata A

    更新日期:2016-12-21 00:00:00

  • Wavelet compression in medical terahertz pulsed imaging.

    abstract::This paper concerns the robustness of discrete wavelet transform (DWT) compression in terahertz pulsed imaging (TPI). TPI datasets consist of terahertz time-domain series which are sampled at each 'pixel' of the image, leading to file sizes which are typically of the order of several megabytes (MB) per image. This mak...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/21/328

    authors: Handley JW,Fitzgerald AJ,Berry E,Boyle RD

    更新日期:2002-11-07 00:00:00

  • Effect of electron contamination of a 6 MV x-ray beam on near surface diode dosimetry.

    abstract::In critical organ in vivo x-ray dosimetry, the relative contaminating electron contribution to the total dose and total detector response outside the field will be different to the corresponding contributions at the central axis detector calibration position, mainly due to the effects of shielding in the linear accele...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/24/013

    authors: Edwards CR,Mountford PJ,Moloney AJ

    更新日期:2006-12-21 00:00:00

  • A method for estimating radiation interaction coefficients for tissues from single energy CT.

    abstract::A parametric model for the x-ray linear attenuation coefficient is used to describe the compositional dependence of Hounsfield numbers measured by medical CT scanners. Measurements with materials of known density and composition, that span and evenly sample the compositional range of tissues, are written as linear sim...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/23/7479

    authors: Midgley SM

    更新日期:2014-12-07 00:00:00

  • 3D radiotherapy dose prediction on head and neck cancer patients with a hierarchically densely connected U-net deep learning architecture.

    abstract::The treatment planning process for patients with head and neck (H&N) cancer is regarded as one of the most complicated due to large target volume, multiple prescription dose levels, and many radiation-sensitive critical structures near the target. Treatment planning for this site requires a high level of human experti...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab039b

    authors: Nguyen D,Jia X,Sher D,Lin MH,Iqbal Z,Liu H,Jiang S

    更新日期:2019-03-18 00:00:00

  • Symmetries of the 2D magnetic particle imaging system matrix.

    abstract::In magnetic particle imaging (MPI), the relation between the particle distribution and the measurement signal can be described by a linear system of equations. For 1D imaging, it can be shown that the system matrix can be expressed as a product of a convolution matrix and a Chebyshev transformation matrix. For multidi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/10/4033

    authors: Weber A,Knopp T

    更新日期:2015-05-21 00:00:00

  • A quantitative assessment of the depth sensitivity of an optical topography system using a solid dynamic tissue-phantom.

    abstract::A solid dynamic phantom with tissue-like optical properties is presented, which contains seven discrete targets impregnated with thermochromic pigment located at different depths from the surface. Changes in absorption are obtained in response to localized heating of the targets, simulating haemodynamic changes occurr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/20/016

    authors: Correia T,Banga A,Everdell NL,Gibson AP,Hebden JC

    更新日期:2009-10-21 00:00:00

  • Structural and practical identifiability of dual-input kinetic modeling in dynamic PET of liver inflammation.

    abstract::Dynamic 18F-FDG PET with tracer kinetic modeling has the potential to noninvasively evaluate human liver inflammation using the FDG blood-to-tissue transport rate K 1. Accurate kinetic modeling of dynamic liver PET data and K 1 quantification requires the knowledge of dual-blood input function from the hepatic artery ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab1f29

    authors: Zuo Y,Sarkar S,Corwin MT,Olson K,Badawi RD,Wang G

    更新日期:2019-09-05 00:00:00

  • The local noise property in positron volume imaging and optimal conditions for the signal-to-noise ratio of the 3D reconstructed image.

    abstract::The local noise property of a 3D PET reconstructed image is investigated for a uniform-activity sphere distributed in a constantly attenuating spherical object. The positional dependence of the statistical noise is approximately derived and calculated for some special cases. It is suggested that a larger diameter of t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/1/015

    authors: Murayama H,Nohara N

    更新日期:1997-01-01 00:00:00

  • Monte Carlo dosimetric study of the BEBIG Co-60 HDR source.

    abstract::Although not as widespread as Ir-192, Co-60 is also available on afterloading equipment devoted to high dose rate brachytherapy, mainly addressed to the treatment of gynaecological lesions. The purpose of this study is to obtain the dosimetric parameters of the Co-60 source used by the BEBIG MultiSource remote afterlo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/21/N03

    authors: Ballester F,Granero D,Pérez-Calatayud J,Casal E,Agramunt S,Cases R

    更新日期:2005-11-07 00:00:00

  • Investigation of the refractive index decrement of 3D printing materials for manufacturing breast phantoms for phase contrast imaging.

    abstract::3D breast modelling for 2D and 3D breast x-ray imaging would benefit from the availability of digital and physical phantoms that reproduce accurately the complexity of the breast anatomy. While a number of groups have produced digital phantoms with increasing level of complexity, physical phantoms reproducing that sof...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab0670

    authors: Esposito G,Mettivier G,Bliznakova K,Bliznakov Z,Bosmans H,Bravin A,Buliev I,Di Lillo F,Ivanov D,Minutillo M,Sarno A,Vignero J,Russo P

    更新日期:2019-03-27 00:00:00

  • On light sharing TOF-PET modules with depth of interaction and 157 ps FWHM coincidence time resolution.

    abstract::The performance of a light sharing and recirculation mechanism that allows the extraction of depth of interaction (DOI) are investigated in this paper, with a particular focus on timing. In parallel, a method to optimize the coincidence time resolution (CTR) of PET detectors by use of the DOI information is proposed a...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2cb0

    authors: Pizzichemi M,Polesel A,Stringhini G,Gundacker S,Lecoq P,Tavernier S,Paganoni M,Auffray E

    更新日期:2019-08-07 00:00:00

  • A new method of body habitus correction for total body potassium measurements.

    abstract::This paper describes an accurate and time-efficient method for the determination of total body potassium via a combination of measurements in the Birmingham whole body counter and the use of the Monte Carlo n-particle (MCNP) simulation code. In developing this method, MCNP has also been used to derive values for some ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/17/009

    authors: O'Hehir S,Green S,Beddoe AH

    更新日期:2006-09-07 00:00:00

  • Error propagation in quantitative biplane cineroentgenography.

    abstract::The propagation of errors in quantitative biplane cineroentgenography was investigated to see which variables were the most critical. The analysis was carried out both for the propagation of root-mean-square errors and for errors as derived by a Taylor expansion of the reconstruction equations. The reconstruction is m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/23/4/009

    authors: Smith WM,Starmer CF

    更新日期:1978-07-01 00:00:00

  • Simulation study of the second-generation MR-compatible SPECT system based on the inverted compound-eye gamma camera design.

    abstract::In this paper, we present simulation studies for the second-generation MRI compatible SPECT system, MRC-SPECT-II, based on an inverted compound eye (ICE) gamma camera concept. The MRC-SPECT-II system consists of a total of 1536 independent micro-pinhole-camera-elements (MCEs) distributed in a ring with an inner diamet...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa4fb

    authors: Lai X,Meng LJ

    更新日期:2018-02-12 00:00:00

  • Fast calculation of 3D radiofrequency ablation zone based on a closed-form solution of heat conduction equation fitted by ex vivo measurements.

    abstract::Fast calculation or simulation of the ablation zone induced by radiofrequency ablation (RFA) has a critical role in hepatic RFA planning and therapy. However, it remains challenging to approximate the ablation zone in real time, especially when more than one probe is involved in one ablation session. This paper presen...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abe052

    authors: Chen R,Zhang J,Kong D,Lou Q,Lu F

    更新日期:2021-01-27 00:00:00

  • An automatic algorithm for detecting stent endothelialization from volumetric optical coherence tomography datasets.

    abstract::Recent research has suggested that endothelialization of vascular stents is crucial to reducing the risk of late stent thrombosis. With a resolution of approximately 10 microm, optical coherence tomography (OCT) may be an appropriate imaging modality for visualizing the vascular response to a stent and measuring the p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/12/001

    authors: Bonnema GT,Cardinal KO,Williams SK,Barton JK

    更新日期:2008-06-21 00:00:00

  • Adaptation and applications of a realistic digital phantom based on patient lung tumor trajectories.

    abstract::Digital phantoms continue to play a significant role in modeling and characterizing medical imaging. The currently available XCAT phantom incorporates both the flexibility of mathematical phantoms and the realistic nature of voxelized phantoms. This phantom generates images based on a regular breathing pattern and can...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/11/3597

    authors: Mishra P,St James S,Segars WP,Berbeco RI,Lewis JH

    更新日期:2012-06-07 00:00:00

  • Alanine dosimetry in strong magnetic fields: use as a transfer standard in MRI-guided radiotherapy.

    abstract::Reference dosimetry in the presence of a strong magnetic field is challenging. Ionisation chambers have shown to be strongly affected by magnetic fields. There is a need for robust and stable detectors in MRI-guided radiotherapy (MRIgRT). This study investigates the behaviour of the alanine dosimeter in magnetic field...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8148

    authors: Billas I,Bouchard H,Oelfke U,Shipley D,Gouldstone C,Duane S

    更新日期:2020-06-03 00:00:00

  • An efficient strategy based on an individualized selection of registration methods. Application to the coregistration of MR and SPECT images in neuro-oncology.

    abstract::An efficient registration strategy is described that aims to help solve delicate medical imaging registration problems. It consists of running several registration methods for each dataset and selecting the best one for each specific dataset, according to an evaluation criterion. Finally, the quality of the registrati...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/22/6997

    authors: Tacchella JM,Roullot E,Lefort M,Cohen ME,Guillevin R,Petrirena G,Delattre JY,Habert MO,Yeni N,Kas A,Frouin F

    更新日期:2014-11-21 00:00:00

  • Monte Carlo and experimental evaluation of accuracy and noise properties of two scatter correction methods for SPECT.

    abstract::Scatter correction is a prerequisite for quantitative SPECT, but potentially increases noise. Monte Carlo simulations (EGS4) and physical phantom measurements were used to compare accuracy and noise properties of two scatter correction techniques: the triple-energy window (TEW), and the transmission dependent convolut...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/11/017

    authors: Narita Y,Eberl S,Iida H,Hutton BF,Braun M,Nakamura T,Bautovich G

    更新日期:1996-11-01 00:00:00