Generalized method for computation of true thickness and x-ray intensity information in highly blurred sub-millimeter bone features in clinical CT images.

Abstract:

:In clinical computed tomography (CT) images, cortical bone features with sub-millimeter (sub-mm) thickness are substantially blurred, such that their thickness is overestimated and their intensity appears underestimated. Therefore, any inquiry of the geometry or the density of such bones based on these images is severely error prone. We present a model-based method for estimating the true thickness and intensity magnitude of cortical and trabecular bone layers at localized regions of complex shell bones down to 0.25 mm. The method also computes the width of the corresponding point spread function. This approach is applicable on any CT image data, and does not rely on any scanner-specific parameter inputs beyond what is inherently available in the images themselves. The method applied on CT intensity profiles of custom phantoms mimicking shell-bones produced average cortical thickness errors of 0.07 ± 0.04 mm versus an average error of 0.47 ± 0.29 mm in the untreated cases (t(55) = 10.92, p ≪ 0.001)). Similarly, the average error of intensity magnitude estimates of the method were 22 ± 2.2 HU versus an error of 445 ± 137 HU in the untreated cases (t(55) = 26.48, p ≪ 0.001)). The method was also used to correct the CT intensity profiles from a cadaveric specimen of the craniofacial skeleton (CFS) in 15 different regions. There was excellent agreement between the corrections and µCT intensity profiles of the same regions used as a 'gold standard' measure. These results set the groundwork towards restoring cortical bone geometry and intensity information in entire image data sets. This information is essential for the generation of finite element models of the CFS that can accurately describe the biomechanical behavior of its complex thin bone structures.

journal_name

Phys Med Biol

authors

Pakdel A,Robert N,Fialkov J,Maloul A,Whyne C

doi

10.1088/0031-9155/57/23/8099

subject

Has Abstract

pub_date

2012-12-07 00:00:00

pages

8099-116

issue

23

eissn

0031-9155

issn

1361-6560

journal_volume

57

pub_type

杂志文章
  • The use of the Henyey-Greenstein phase function in Monte Carlo simulations in biomedical optics.

    abstract::Monte Carlo (MC) simulations are often at the heart of the testing procedure in biomedical optics. One of the critical points in MC simulations is to define the new photon direction after each scattering event. One of the most popular solutions is to use the Henyey-Greenstein phase function or some linear combinations...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/17/N04

    authors: Binzoni T,Leung TS,Gandjbakhche AH,Rüfenacht D,Delpy DT

    更新日期:2006-09-07 00:00:00

  • Optimization of the electric field distribution in a large volume tissue-equivalent proportional counter.

    abstract::Large volume tissue-equivalent proportional counters are of interest in radiation protection metrology, as the sensitivity in terms of counts per unit absorbed dose in these devices increases as the square of the counter diameter. Conventional solutions to the problem of maintaining a uniform electric field within a c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/10/002

    authors: Verma PK,Waker AJ

    更新日期:1992-10-01 00:00:00

  • Calibration of CT Hounsfield units for radiotherapy treatment planning of patients with metallic hip prostheses: the use of the extended CT-scale.

    abstract::Heterogeneity corrections for radiotherapy dose calculations are based on the electron density of the disturbing heterogeneity. However, when CT planning a radiotherapy treatment, where metallic hip implants are present, considerable artefacts are seen in the images. Often, an additional problem arises whereby no info...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/11/308

    authors: Coolens C,Childs PJ

    更新日期:2003-06-07 00:00:00

  • Monte Carlo simulated corrections for beam commissioning measurements with circular and MLC shaped fields on the CyberKnife M6 System: a study including diode, microchamber, point scintillator, and synthetic microdiamond detectors.

    abstract::Monte Carlo simulation was used to calculate correction factors for output factor (OF), percentage depth-dose (PDD), and off-axis ratio (OAR) measurements with the CyberKnife M6 System. These include the first such data for the InCise MLC. Simulated detectors include diodes, air-filled microchambers, a synthetic micro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5610

    authors: Francescon P,Kilby W,Noll JM,Masi L,Satariano N,Russo S

    更新日期:2017-02-07 00:00:00

  • Characterization of the secondary neutron field produced during treatment of an anthropomorphic phantom with x-rays, protons and carbon ions.

    abstract::Short- and long-term side effects following the treatment of cancer with radiation are strongly related to the amount of dose deposited to the healthy tissue surrounding the tumor. The characterization of the radiation field outside the planned target volume is the first step for estimating health risks, such as devel...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/8/2111

    authors: Tessa CL,Berger T,Kaderka R,Schardt D,Burmeister S,Labrenz J,Reitz G,Durante M

    更新日期:2014-04-21 00:00:00

  • Evaluation of a ferrous benzoic xylenol orange transparent PVA cryogel radiochromic dosimeter.

    abstract::A stable cryogel dosimeter was prepared using ferrous benzoic xylenol orange (FBX) in a transparent poly-(vinyl alcohol) (PVA) cryogel matrix. Dose response was evaluated for different numbers of freeze-thaw cycles (FTCs), different concentrations of PVA, and ratios of water/dimethyl sulfoxide. Linear relationships be...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/7/1773

    authors: Eyadeh MM,Farrell TJ,Diamond KR

    更新日期:2014-04-07 00:00:00

  • Investigation of the performance of antiscatter grids: Monte Carlo simulation studies.

    abstract::Monte Carlo methods have been applied to the study of the performance of antiscatter grids in radiography. Photon histories for imaging with a 20 cm thick water phantom irradiated with an 80 kV x-ray spectrum were generated by Monte Carlo simulation. The scattering and absorption of the photons transmitted from the ph...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/27/6/002

    authors: Chan HP,Doi K

    更新日期:1982-06-01 00:00:00

  • Measurement of the dielectric properties of the epidermis and dermis at frequencies from 0.5 GHz to 110 GHz.

    abstract::Numerous studies have reported the measurements of the dielectric properties of the skin. Clarifying the manner in which the human body interacts with electromagnetic waves is essential for medical research and development, as well as for the safety assessment of electromagnetic wave exposure. The skin comprises sever...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/16/4739

    authors: Sasaki K,Wake K,Watanabe S

    更新日期:2014-08-21 00:00:00

  • A biological approach to the platelet survival curve with criticism of previous interpretations.

    abstract::The biological mechanisms of platelet destruction must be correctly identified before platelet survival curves can be interpreted. This report develops a theory of platelet destruction which is compared with experiments performed on platelets labelled with the radioactive isotope 51Cr. Platelet destruction rate is a c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/28/12/001

    authors: Trowbridge EA,Martin JF

    更新日期:1983-12-01 00:00:00

  • Dual energy x-ray laser measurement of calcaneal bone mineral density.

    abstract::In dual energy x-ray absorptiometry (DXA) the photon attenuation is assumed to be similar in soft tissue overlying, adjacent to and inside the measured bone. In the calcaneal dual energy x-ray laser (DXL) technique, this assumption is not needed as attenuation by soft tissues at the local bone site is determined by co...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/12/305

    authors: Hakulinen MA,Saarakkala S,Töyräs J,Kröger H,Jurvelin JS

    更新日期:2003-06-21 00:00:00

  • Determination of some parameters for pion radiobiology studies.

    abstract::An experimental investigation of the central axis depth-dose and stopping rate distribution of the SIN biomedical pion beam is reported. The pion stopping rate in a thin disc of tissue-equivalent plastic was determined using a counter telescope. The dose rate at the position of this dic 'target' was measured using a s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/22/3/007

    authors: Nordell B,Baarli J,Sullivan AH,Zielczynski M

    更新日期:1977-05-01 00:00:00

  • Evaluation of 209At as a theranostic isotope for 209At-radiopharmaceutical development using high-energy SPECT.

    abstract::The development of alpha-emitting radiopharmaceuticals using 211At requires quantitative determination of the time-dependent nature of the 211At biodistribution. However, imaging-based methods for acquiring this information with 211At have not found wide-spread use because of its low abundance of decay emissions suita...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaaa95

    authors: Crawford JR,Robertson AKH,Yang H,Rodríguez-Rodríguez C,Esquinas PL,Kunz P,Blinder S,Sossi V,Schaffer P,Ruth TJ

    更新日期:2018-02-21 00:00:00

  • Comparison study of temporal regularization methods for fully 5D reconstruction of cardiac gated dynamic SPECT.

    abstract::Temporal regularization plays a critical role in cardiac gated dynamic SPECT reconstruction, of which the goal is to obtain an image sequence from a single acquisition which simultaneously shows both cardiac motion and tracer distribution change over the course of imaging (termed 5D). In our recent work, we explored t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/17/5523

    authors: Niu X,Yang Y,King MA

    更新日期:2012-09-07 00:00:00

  • Prediction of lung tumor motion using nonlinear autoregressive model with exogenous input.

    abstract::The present note addresses the development of a lung tumor position predictor to be used in dynamic tumor tracking radiotherapy, abbreviated as DTT-RT. As there exists 50-500 ms positioning lag in the control of the multi-leaf collimator (MLC) of commercial medical linear accelerators, prediction of future lung tumor ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab49ea

    authors: Jiang K,Fujii F,Shiinoki T

    更新日期:2019-10-31 00:00:00

  • Evaluation of a novel triple-channel radiochromic film analysis procedure using EBT2.

    abstract::A novel approach to read out radiochromic film was introduced recently by the manufacturer of GafChromic film. In this study, the performance of this triple-channel film dosimetry method was compared against the conventional single-red-channel film dosimetry procedure, with and without inclusion of a pre-irradiation (...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/13/4353

    authors: van Hoof SJ,Granton PV,Landry G,Podesta M,Verhaegen F

    更新日期:2012-07-07 00:00:00

  • Dosimetric verification of open asymmetric photon fields calculated with a treatment planning system based on dose-to-energy-fluence concepts.

    abstract::Output normalized dose profiles for asymmetric open photon fields has been calculated using a commercial treatment planning system (TPS) based on a dose-to-energy-fluence concept. The model does not require any additional measurements for off-axis fields. Calculations are compared with measurements for quadratic field...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/8/003

    authors: Hurkmans C,Knöös T,Nilsson P

    更新日期:1996-08-01 00:00:00

  • A note on computing the derivative at a constant direction.

    abstract::The derivative at constant direction is frequently used in inversion of cone-beam data. Several algorithms for computing the derivative have been proposed in the literature. The best algorithm to date has been proposed recently by Noo et al (2007 Phys. Med. Biol. 52 5393-414). In this note we propose a new, simple and...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/4/N01

    authors: Katsevich A

    更新日期:2011-02-21 00:00:00

  • Automated detection of spinal centrelines, vertebral bodies and intervertebral discs in CT and MR images of lumbar spine.

    abstract::We propose a completely automated algorithm for the detection of the spinal centreline and the centres of vertebral bodies and intervertebral discs in images acquired by computed tomography (CT) and magnetic resonance (MR) imaging. The developed methods are based on the analysis of the geometry of spinal structures an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/1/015

    authors: Stern D,Likar B,Pernus F,Vrtovec T

    更新日期:2010-01-07 00:00:00

  • A method for photon beam Monte Carlo multileaf collimator particle transport.

    abstract::Monte Carlo (MC) algorithms are recognized as the most accurate methodology for patient dose assessment. For intensity-modulated radiation therapy (IMRT) delivered with dynamic multileaf collimators (DMLCs), accurate dose calculation, even with MC, is challenging. Accurate IMRT MC dose calculations require inclusion o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/17/312

    authors: Siebers JV,Keall PJ,Kim JO,Mohan R

    更新日期:2002-09-07 00:00:00

  • Automatic T1 bladder tumor detection by using wavelet analysis in cystoscopy images.

    abstract::Correct classification of cystoscopy images depends on the interpreter's experience. Bladder cancer is a common lesion that can only be confirmed by biopsying the tissue, therefore, the automatic identification of tumors plays a significant role in early stage diagnosis and its accuracy. To our best knowledge, the use...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa3af

    authors: Freitas NR,Vieira PM,Lima E,Lima CS

    更新日期:2018-02-02 00:00:00

  • Multi-feature-based plaque characterization in ex vivo MRI trained by registration to 3D histology.

    abstract::We present a new method for automated characterization of atherosclerotic plaque composition in ex vivo MRI. It uses MRI intensities as well as four other types of features: smoothed, gradient magnitude and Laplacian images at several scales, and the distances to the lumen and outer vessel wall. The ground truth for f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/1/241

    authors: van Engelen A,Niessen WJ,Klein S,Groen HC,Verhagen HJ,Wentzel JJ,van der Lugt A,de Bruijne M

    更新日期:2012-01-07 00:00:00

  • MR-compatibility assessment of MADPET4: a study of interferences between an SiPM-based PET insert and a 7 T MRI system.

    abstract::Compromises in the design of a positron emission tomography (PET) insert for a magnetic resonance imaging (MRI) system should minimize the deterioration of image quality in both modalities, particularly when simultaneous demanding acquisitions are performed. In this work, the advantages of using individually read-out ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aab9d1

    authors: Omidvari N,Topping G,Cabello J,Paul S,Schwaiger M,Ziegler SI

    更新日期:2018-05-01 00:00:00

  • Simulation of voltage-sensitive optical signals in three-dimensional slabs of cardiac tissue: application to transillumination and coaxial imaging methods.

    abstract::Voltage-sensitive dyes are an important tool in visualizing electrical activity in cardiac tissue. Until today, they have mainly been applied in cardiac electrophysiology to subsurface imaging. In the present study, we assess different imaging methods used in optical tomography with respect to their effectiveness in v...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/2/003

    authors: Bernus O,Wellner M,Mironov SF,Pertsov AM

    更新日期:2005-01-21 00:00:00

  • Fast online Monte Carlo-based IMRT planning for the MRI linear accelerator.

    abstract::The MRI accelerator, a combination of a 6 MV linear accelerator with a 1.5 T MRI, facilitates continuous patient anatomy updates regarding translations, rotations and deformations of targets and organs at risk. Accounting for these demands high speed, online intensity-modulated radiotherapy (IMRT) re-optimization. In ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/5/1375

    authors: Bol GH,Hissoiny S,Lagendijk JJ,Raaymakers BW

    更新日期:2012-03-07 00:00:00

  • Scatter dose for wedged fields.

    abstract::The behaviour of scatter dose in 4 and 8 MV wedged x-ray beams has been studied by calculating scatter-to-primary dose ratios (SPR) and comparing these with SPR for non-wedged beams. On the central axis the SPR for wedged and non-wedged beams differ only by a few per cent, a difference which increases slightly with we...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/10/010

    authors: Brown LH,Siddon RL,Bjärngard BE

    更新日期:1987-10-01 00:00:00

  • Super-resolution reconstruction of 4D-CT lung data via patch-based low-rank matrix reconstruction.

    abstract::Lung 4D computed tomography (4D-CT), which is a time-resolved CT data acquisition, performs an important role in explicitly including respiratory motion in treatment planning and delivery. However, the radiation dose is usually reduced at the expense of inter-slice spatial resolution to minimize radiation-related heal...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa8a48

    authors: Fang S,Wang H,Liu Y,Zhang M,Yang W,Feng Q,Chen W,Zhang Y

    更新日期:2017-10-03 00:00:00

  • Use of an amorphous silicon EPID for measuring MLC calibration at varying gantry angle.

    abstract::Amorphous silicon electronic portal imaging devices (EPIDs) are used to perform routine quality control (QC) checks on the multileaf collimators (MLCs) at this centre. Presently, these checks are performed at gantry angle 0 degrees and are considered to be valid for all other angles. Since therapeutic procedures regul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/2/013

    authors: Clarke MF,Budgell GJ

    更新日期:2008-01-21 00:00:00

  • On light sharing TOF-PET modules with depth of interaction and 157 ps FWHM coincidence time resolution.

    abstract::The performance of a light sharing and recirculation mechanism that allows the extraction of depth of interaction (DOI) are investigated in this paper, with a particular focus on timing. In parallel, a method to optimize the coincidence time resolution (CTR) of PET detectors by use of the DOI information is proposed a...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2cb0

    authors: Pizzichemi M,Polesel A,Stringhini G,Gundacker S,Lecoq P,Tavernier S,Paganoni M,Auffray E

    更新日期:2019-08-07 00:00:00

  • Impact of free-breathing CT on quantitative measurements of static and quiescent period-gated PET Images.

    abstract::Measurements of standardized uptake values (SUV) can vary due to many causes, including respiratory motion. Various methodologies have been introduced to correct for motion in PET, with quiescent-period-gated (QPG) PET being the most popular approach. QPG has been shown to improve PET image quantification compared to ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab1cdd

    authors: Meier JG,Einstein SA,Diab RH,Erasmus LJ,Xu G,Mawlawi OR

    更新日期:2019-05-16 00:00:00

  • Mucosal deformation from an impinging transonic gas jet and the ballistic impact of microparticles.

    abstract::By means of a transonic gas jet, gene guns ballistically deliver microparticle formulations of drugs and vaccines to the outer layers of the skin or mucosal tissue to induce unique physiological responses for the treatment of a range of conditions. Reported high-speed imaging experiments show that the mucosa deforms s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/19/010

    authors: Hardy MP,Kendall MA

    更新日期:2005-10-07 00:00:00