Prediction of lung tumor motion using nonlinear autoregressive model with exogenous input.

Abstract:

:The present note addresses the development of a lung tumor position predictor to be used in dynamic tumor tracking radiotherapy, abbreviated as DTT-RT. As there exists 50-500 ms positioning lag in the control of the multi-leaf collimator (MLC) of commercial medical linear accelerators, prediction of future lung tumor position with sufficiently long prediction horizon is inevitable for the successful implementation of DTT-RT. The present article proposes a lung tumor position predictor, which is classified as a nonlinear autoregressive model with exogenous input (NARX). The proposed predictor was trained using seven lung tumor motion trajectories of patients who underwent respiratory gated radiotherapy at Yamaguchi University Hospital. We considered three different prediction horizons, 600 ms, 800 ms and 1 s, which were sufficiently long to compensate for the possible positioning control lag of the MLC. A patient-specific model corresponding to an intended prediction horizon was obtained by training it using the selected tumor motion trajectory with the specified horizon. Accordingly, we obtained three NARX predictors for a single patient. We calculated two performance metrics: the RMS prediction errors and the rate of coverage of the entire tumor trajectory defined by the number of samples of the measured tumor position which was inside the 4 mm cube centered at the corresponding predicted tumor position. The latter quantifies the feasibility of the predictors to generate future gating cubes in the implementation of DTT-RT. The [Formula: see text] (mean [Formula: see text] standard deviation) values of the rates of 600 ms, 800 ms and 1 s prediction horizon calculated using the proposed NARX predictors were [Formula: see text]%, [Formula: see text]% and [Formula: see text]%, respectively.

journal_name

Phys Med Biol

authors

Jiang K,Fujii F,Shiinoki T

doi

10.1088/1361-6560/ab49ea

subject

Has Abstract

pub_date

2019-10-31 00:00:00

pages

21NT02

issue

21

eissn

0031-9155

issn

1361-6560

journal_volume

64

pub_type

杂志文章
  • Image quality assessment in digital mammography: part II. NPWE as a validated alternative for contrast detail analysis.

    abstract::Assessment of image quality for digital x-ray mammography systems used in European screening programs relies mainly on contrast-detail CDMAM phantom scoring and requires the acquisition and analysis of many images in order to reduce variability in threshold detectability. Part II of this study proposes an alternative ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/14/003

    authors: Monnin P,Marshall NW,Bosmans H,Bochud FO,Verdun FR

    更新日期:2011-07-21 00:00:00

  • Volumetric CT with sparse detector arrays (and application to Si-strip photon counters).

    abstract::Novel x-ray medical imaging sensors, such as photon counting detectors (PCDs) and large area CCD and CMOS cameras can involve irregular and/or sparse sampling of the detector plane. Application of such detectors to CT involves undersampling that is markedly different from the commonly considered case of sparse angular...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/1/90

    authors: Sisniega A,Zbijewski W,Stayman JW,Xu J,Taguchi K,Fredenberg E,Lundqvist M,Siewerdsen JH

    更新日期:2016-01-07 00:00:00

  • A method of improving the spatial resolution of treatments that involve a multileaf collimator.

    abstract::In this paper we present a novel method of reducing the dosimetric effects of the finite leaf width of a multileaf collimator (MLC) in conformal and intensity modulated radiotherapy (IMRT). This is achieved by decomposing the required high-resolution fluence distribution into two orthogonal components, which are deliv...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/3/304

    authors: Evans PM,Partridge M

    更新日期:2000-03-01 00:00:00

  • Head scatter modelling for irregular field shaping and beam intensity modulation.

    abstract::Scattered radiation from within the treatment head can contribute significant dose to all parts of a radiotherapy treatment field. A multileaf collimator may be used to create an arbitrarily shaped field, and may also be used, under dynamic control, to modulate the beam intensity over the field. This method of intensi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/9/006

    authors: Hounsell AR,Wilkinson JM

    更新日期:1997-09-01 00:00:00

  • Implementation and analysis of relief patterns of the surface of benign and malignant lesions of the skin by microtopography.

    abstract::The objective of this study was to be able to distinguish between healthy skin tissue and malignant ones, furthermore determining a unique pattern of roughness for each skin lesion by microtopographic analysis of the skin surface of Mexican patients during the period from April to October 2002. The standard technique ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/23/008

    authors: del Carmen López Pacheco M,da Cunha Martins-Costa MF,Zapata AJ,Cherit JD,Gallegos ER

    更新日期:2005-12-07 00:00:00

  • A motion-incorporated reconstruction method for gated PET studies.

    abstract::Cardiac and respiratory motion artefacts in PET imaging have been traditionally resolved by acquiring the data in gated mode. However, gated PET images are usually characterized by high noise content due to their low photon statistics. In this paper, we present a novel 4D model for the PET imaging system, which can in...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/15/012

    authors: Qiao F,Pan T,Clark JW Jr,Mawlawi OR

    更新日期:2006-08-07 00:00:00

  • Factorial phase imaging: a new concept in the analysis of first-pass cardiac studies.

    abstract::A method is described which offers an alternative to conventional Fourier phase/amplitude imaging for analysing representative LV cycles obtained from first-pass cardiac studies. The method involves applying factor analysis to the data and producing functional images of the first two factor loadings after polar transf...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/27/10/007

    authors: Houston AS,Elliott AT,Stone DL

    更新日期:1982-10-01 00:00:00

  • Respiration gated radiotherapy treatment: a technical study.

    abstract::In order to optimize external-beam conformal radiotherapy, patient movement during treatment must be minimized. For treatment on the upper torso, the target organs are known to move substantially due to patient respiration. This paper deals with the technical aspects of gating the radiotherapy beam synchronously with ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/1/007

    authors: Kubo HD,Hill BC

    更新日期:1996-01-01 00:00:00

  • Denoising of multi b-value diffusion-weighted MR images using deep image prior.

    abstract::The clinical value of multiple b-value diffusion-weighted (DW) magnetic resonance imaging (MRI) has been shown in many studies. However, DW-MRI often suffers from low signal-to-noise ratio, especially at high b-values. To address this limitation, we present an image denoising method based on the concept of deep image ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8105

    authors: Lin YC,Huang HM

    更新日期:2020-05-11 00:00:00

  • Dosimetric verification of open asymmetric photon fields calculated with a treatment planning system based on dose-to-energy-fluence concepts.

    abstract::Output normalized dose profiles for asymmetric open photon fields has been calculated using a commercial treatment planning system (TPS) based on a dose-to-energy-fluence concept. The model does not require any additional measurements for off-axis fields. Calculations are compared with measurements for quadratic field...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/8/003

    authors: Hurkmans C,Knöös T,Nilsson P

    更新日期:1996-08-01 00:00:00

  • A multiplicative correction factor for tissue heterogeneities.

    abstract::A new multiplicative correction factor for tissue heterogeneities based on an exact expression for homogeneous non-unit-density media is proposed. O'Connor's density scaling theorem is invoked to evaluate the medium-specific tissue-maximum ratios used in the exact formulation. Monte Carlo calculations were performed a...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/10/005

    authors: Petti PL,Siddon RL,Bjärngard BE

    更新日期:1986-10-01 00:00:00

  • Plane wave versus focused transmissions for contrast enhanced ultrasound imaging: the role of parameter settings and the effects of flow rate on contrast measurements.

    abstract::Contrast enhanced ultrasound (CEUS) and dynamic contrast enhanced ultrasound (DCE-US) can be used to provide information about the vasculature aiding diagnosis and monitoring of a number of pathologies including cancer. In the development of a CEUS imaging system, there are many choices to be made, such as whether to ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab13f2

    authors: Moghimirad E,Bamber J,Harris E

    更新日期:2019-04-23 00:00:00

  • The feasibility of using a liquid-filled Cerenkov counter of gamma-ray counting of large samples.

    abstract::The feasibility of detecting gamma rays with energies below 1.5 MeV by means of a large-volume liquid-filled Cerenkov counter has been examined, together with the characteristics and limitations of an experimental counter. Various liquids (water, glycerol, sodium iodide solution; and glycerol plus a wavelength shifter...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/23/3/007

    authors: Hesp R

    更新日期:1978-05-01 00:00:00

  • Estimation of percentage body fat by dual-energy x-ray absorptiometry: evaluation by in vivo human elemental composition.

    abstract::Dual-energy x-ray absorptiometry (DXA) is widely applied for estimating body fat. The percentage of body mass as fat (%fat) is predicted from a DXA-estimated R(ST) value defined as the ratio of soft tissue attenuation at two photon energies (e.g., 40 keV and 70 keV). Theoretically, the R(ST) concept depends on the mas...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/9/013

    authors: Wang Z,Heymsfield SB,Chen Z,Zhu S,Pierson RN

    更新日期:2010-05-07 00:00:00

  • A robust approach to IMRT optimization.

    abstract::Managing uncertainty is a major challenge in radiation therapy treatment planning, including uncertainty induced by intrafraction motion, which is particularly important for tumours in the thorax and abdomen. Common methods to account for motion are to introduce a margin or to convolve the static dose distribution wit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/10/014

    authors: Chan TC,Bortfeld T,Tsitsiklis JN

    更新日期:2006-05-21 00:00:00

  • PETSIM: Monte Carlo simulation of all sensitivity and resolution parameters of cylindrical positron imaging systems.

    abstract::Monte Carlo simulation techniques are applied to track the annihilation photons from positron decay, and store the photon histories. Reasonably realistic models of the isotope distribution in the brain and heart during typical PET studies, as well as the traditional phantoms used for measuring PET scanner performance ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/3/017

    authors: Thompson CJ,Moreno-Cantu J,Picard Y

    更新日期:1992-03-01 00:00:00

  • Dose conversion coefficients for paediatric CT examinations with automatic tube current modulation.

    abstract::A common dose-saving technique used in modern CT devices is automatic tube current modulation (TCM), which was originally designed to also reduce the dose in paediatric CT patients. In order to be able to deduce detailed organ doses of paediatric models, dose conversion coefficients normalized to CTDI(vol) for an eigh...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/20/6309

    authors: Schlattl H,Zankl M,Becker J,Hoeschen C

    更新日期:2012-10-21 00:00:00

  • The gastrointestinal absorption of plutonium and americium in the hamster.

    abstract::Plutonium-239 and americium-241 were administered to adult hamsters in various chemical forms and their absorption from the gut was measured. The results have been compared with published data on other species in order to derive values for the estimated absorption of these actinides in man. On the basis of current kno...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/24/2/015

    authors: Stather JW,Harrison JD,Rodwell P,David AJ

    更新日期:1979-03-01 00:00:00

  • Normalized mean glandular dose computation from mammography using GATE: a validation study.

    abstract::Mean glandular dose (MGD) is the figure of merit to assess breast dose after a mammographic acquisition. The use of normalized MGD obtained from Monte Carlo computations with measured incident air kerma determines the MGD delivered to patients. The Geant4 Application for Tomographic Emission (GATE) toolkit is a modern...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/7/2247

    authors: Myronakis ME,Zvelebil M,Darambara DG

    更新日期:2013-04-07 00:00:00

  • Concentrations of Fe, Cu and Zn in breast tissue: a synchrotron XRF study.

    abstract::An x-ray fluorescence system with a synchrotron radiation source was used to quantify the levels of iron, copper and zinc in breast tissue specimens. Healthy tissue and breast carcinomas were investigated as an aid to understanding the mechanisms of breast cancer and as a possible complementary diagnostic tool. Eighty...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/13/310

    authors: Geraki K,Farquharson MJ,Bradley DA

    更新日期:2002-07-07 00:00:00

  • The impact of morphology on light transport in cancellous bone.

    abstract::In recent years, optical techniques based on diffusion approximation have demonstrated their ability to gain rich spectral information about bone. However, these methods normally assume homogeneity, while cancellous bone and marrow form a highly heterogeneous two-phase medium. This paper studies the limitations of thi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/17/003

    authors: Margallo-Balbás E,Taroni P,Pifferi A,Koolstra JH,v Ruijven LJ,French PJ

    更新日期:2010-09-07 00:00:00

  • Photon quality correction factors for ionization chambers in an epithermal neutron beam.

    abstract::Photon quality correction factors (kQy) for ionization chamber photon dosimetry in an epithermal neutron beam were determined according to a modified absorbed dose to water formalism which was extended to mixed radiation fields. We have studied two commercially available ionization chambers in the epithermal neutron b...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/14/303

    authors: Munck af Rosenschöld PM,Ceberg CP,Giusti V,Andreo P

    更新日期:2002-07-21 00:00:00

  • Dual energy x-ray laser measurement of calcaneal bone mineral density.

    abstract::In dual energy x-ray absorptiometry (DXA) the photon attenuation is assumed to be similar in soft tissue overlying, adjacent to and inside the measured bone. In the calcaneal dual energy x-ray laser (DXL) technique, this assumption is not needed as attenuation by soft tissues at the local bone site is determined by co...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/12/305

    authors: Hakulinen MA,Saarakkala S,Töyräs J,Kröger H,Jurvelin JS

    更新日期:2003-06-21 00:00:00

  • Optimizing robot motion for robotic ultrasound-guided radiation therapy.

    abstract::An important aspect of robotic radiation therapy is active compensation of target motion. Recently, ultrasound has been proposed to obtain real-time volumetric images of abdominal organ motion. One approach to realize flexible probe placement throughout the treatment fraction is based on a robotic arm holding the ultr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab3bfb

    authors: Schlüter M,Fürweger C,Schlaefer A

    更新日期:2019-10-04 00:00:00

  • Laboratory prototype for experimental validation of MR-guided radiofrequency head and neck hyperthermia.

    abstract::Clinical studies have established a strong benefit from adjuvant mild hyperthermia (HT) to radio- and chemotherapy for many tumor sites, including the head and neck (H&N). The recently developed HYPERcollar allows the application of local radiofrequency HT to tumors in the entire H&N. Treatment quality is optimized us...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/9/2139

    authors: Paulides MM,Bakker JF,Hofstetter LW,Numan WC,Pellicer R,Fiveland EW,Tarasek M,Houston GC,van Rhoon GC,Yeo DT,Kotek G

    更新日期:2014-05-07 00:00:00

  • Volume-selective and spectroscopically resolved NMR investigation of diffusion and relaxation in fertilised hen eggs.

    abstract::A radiofrequency and field-gradient pulse sequence is presented permitting the non-invasive, volume-selective and spectroscopically resolved determination of incoherent transport parameters with the aid of an NMR field-gradient method. With proton NMR, diffusion or (quasi-incoherent) perfusion coefficients as low as 1...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/35/1/007

    authors: Klammler F,Kimmich R

    更新日期:1990-01-01 00:00:00

  • Dynamics of polymerization in polyacrylamide gel (PAG) dosimeters: (I) ageing and long-term stability.

    abstract::Few quantitative data are available on the kinetics of polymerization reactions in polymer gel (PAG) dosimeters and their long-term stability. Post-irradiation polymerization reactions have been found to continue for several weeks, posing questions regarding dosimeter stability and its achievement. In this paper we re...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/8/301

    authors: McJury M,Oldham M,Leach MO,Webb S

    更新日期:1999-08-01 00:00:00

  • Measurement of the hyperelastic properties of 44 pathological ex vivo breast tissue samples.

    abstract::The elastic and hyperelastic properties of biological soft tissues have been of interest to the medical community. There are several biomedical applications where parameters characterizing such properties are critical for a reliable clinical outcome. These applications include surgery planning, needle biopsy and brach...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/8/020

    authors: O'Hagan JJ,Samani A

    更新日期:2009-04-21 00:00:00

  • Dosimetric and workflow evaluation of first commercial synthetic CT software for clinical use in pelvis.

    abstract::To evaluate a commercial synthetic CT (syn-CT) software for use in prostate radiotherapy. Twenty-five prostate patients underwent CT and MR simulation scans in treatment position on a 3T MR scanner. A commercially available MR protocol was used that included a T2w turbo spin-echo sequence for soft-tissue contrast and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5452

    authors: Tyagi N,Fontenla S,Zhang J,Cloutier M,Kadbi M,Mechalakos J,Zelefsky M,Deasy J,Hunt M

    更新日期:2017-04-21 00:00:00

  • Dosimetric characterization of a new miniature multileaf collimator.

    abstract::The dosimetrical characteristics of a new miniature multileaf collimator (ModuLeaf MLC, MRC Systems GmbH, Heidelberg, Germany) attached to the accessory holder of a Siemens accelerator with 6 MV x-rays (PRIMUS, Siemens OCS, Concord, California, USA) have been investigated. In particular, those parameters which are imp...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/12/402

    authors: Hartmann GH,Föhlisch F

    更新日期:2002-06-21 00:00:00