Abstract:
:An experimental investigation of the central axis depth-dose and stopping rate distribution of the SIN biomedical pion beam is reported. The pion stopping rate in a thin disc of tissue-equivalent plastic was determined using a counter telescope. The dose rate at the position of this dic 'target' was measured using a specially designed parallel-plate tissue-equivalent ionization chamber. Both dose rate and pion stopping rate are given as a function of depth for beams of two different momenta spread. The energy deposition required per pion stop to fit the measured dose rate curves was calculated and found to be between 37 and 40 MeV. From the stopping rate measurements the depth-dose distribution of pion interaction dose (star-dose) and the dose due to the pion slowing down have been evaluated. The maximum star-dose is found at a depth of about 2 g cm-2 beyound the maximum of the ionization dose.
journal_name
Phys Med Bioljournal_title
Physics in medicine and biologyauthors
Nordell B,Baarli J,Sullivan AH,Zielczynski Mdoi
10.1088/0031-9155/22/3/007subject
Has Abstractpub_date
1977-05-01 00:00:00pages
466-75issue
3eissn
0031-9155issn
1361-6560journal_volume
22pub_type
杂志文章abstract::A multicentre phase II trial of stereotactic body radiotherapy for T1N0M0 non-small cell lung cancer was initiated in Japan as the Japan Clinical Oncology Group trial (JCOG0403). Before starting the trial, a decision was made to evaluate the treatment machine and treatment planning in participating institutions to min...
journal_title:Physics in medicine and biology
pub_type: 杂志文章,多中心研究
doi:10.1088/0031-9155/51/21/002
更新日期:2006-11-07 00:00:00
abstract::For plane-parallel chambers used in electron dosimetry, modern dosimetry protocols recommend a cross-calibration against a calibrated cylindrical chamber. The rationale for this is the unacceptably large (up to 3-4%) chamber-to-chamber variations of the perturbation factors (pwall)Co, which have been reported for plan...
journal_title:Physics in medicine and biology
pub_type: 杂志文章,多中心研究
doi:10.1088/0031-9155/52/23/026
更新日期:2007-12-07 00:00:00
abstract::A quantitative comparison of two full three-dimensional (3D) gel dosimetry techniques was assessed in a clinical setting: radiochromic gel dosimetry with an in-house developed optical laser CT scanner and polymer gel dosimetry with magnetic resonance imaging (MRI). To benchmark both gel dosimeters, they were exposed t...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/18/6241
更新日期:2013-09-21 00:00:00
abstract::Compromises in the design of a positron emission tomography (PET) insert for a magnetic resonance imaging (MRI) system should minimize the deterioration of image quality in both modalities, particularly when simultaneous demanding acquisitions are performed. In this work, the advantages of using individually read-out ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aab9d1
更新日期:2018-05-01 00:00:00
abstract::In this work we present the first delivery of intensity modulated arc therapy on the Elekta Unity 1.5 T MR-linac. The machine's current IMRT based control system was modified suitably to enable dynamic delivery of radiation, for the purpose of exploring MRI-guided radiation therapy adaptation modes in a research setti...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/abd66d
更新日期:2020-12-23 00:00:00
abstract::The effect of the physical state (phase) of the absorbing medium and the energy straggling of the alpha particles on the calculation of the radiation dose due to the daughter products of radon deposited in the lung have been studied in detail. The stopping power data for alpha particles in water and water vapour have ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/32/8/004
更新日期:1987-08-01 00:00:00
abstract::The aim of this study was to measure entrance skin doses on patients undergoing cone-beam computed tomography (CBCT) examinations, to establish conversion factors between skin and organ doses, and to estimate cancer risk from CBCT exposures. 266 patients (age 8-83) were included, involving three imaging centres. CBCT ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/14/3877
更新日期:2014-07-21 00:00:00
abstract::An acardiac twin is a severely malformed monochorionic twin fetus that lacks most organs, particularly a heart. It grows during pregnancy, because it is perfused by its developmentally normal co-twin (called the pump twin) via a set of placental arterioarterial and venovenous anastomoses. The pump twin dies intrauteri...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/49/14/n01
更新日期:2004-07-21 00:00:00
abstract::Prompt γ-ray imaging with a knife-edge shaped slit camera provides the possibility of verifying proton beam range in tumor therapy. Dedicated experiments regarding the characterization of the camera system have been performed previously. Now, we aim at implementing the prototype into clinical application of monitoring...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/61/22/7881
更新日期:2016-11-21 00:00:00
abstract::Compton scatter poses a significant threat to volumetric x-ray computed tomography, bringing cupping and streak artefacts thus impacting qualitative and quantitative imaging procedures. To perform appropriate scatter compensation, it is necessary to estimate the magnitude and spatial distribution of x-ray scatter. The...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/8/010
更新日期:2010-04-21 00:00:00
abstract::A theoretical analysis is presented of the biologically effective dose of the solar long wave ultraviolet radiation (UVA) received by patients who are being treated for psoriasis by oral psoralen photochemotherapy. It is shown that patients treated during the summer months in the UK may well receive a UV dose which is...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/26/6/011
更新日期:1981-11-01 00:00:00
abstract::State of the art point-spread function (PSF) corrections implemented in positron emission tomography/computed tomography (PET/CT) reconstruction improved image quality and diagnostic performance but caused an increase in the standardized uptake value (SUV) compared to a conventional OSEM reconstruction system. The EAN...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aaee27
更新日期:2018-11-26 00:00:00
abstract::An iterative algorithm has been developed to reduce blur artefacts in images obtained from the Pho/Con multiplane tomographic scanner. In this technique estimates of the activity distribution are convolved with the detector response function and compared with the original blurred image planes. Successive estimates of ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/30/7/004
更新日期:1985-07-01 00:00:00
abstract::Margins are employed in radiotherapy treatment planning to mitigate the dosimetric effects of geometric uncertainties for the clinical target volume (CTV). Unfortunately, whilst the use of margins can increase the probability that sufficient dose is delivered to the CTV, it can also result in delivering high dose of r...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aae658
更新日期:2018-10-29 00:00:00
abstract::Catheter-based ultrasound devices provide a method to deliver 3D conformable heating integrated with HDR brachytherapy delivery. Theoretical characterization of heating patterns was performed to identify implant strategies for these devices which can best be used to apply hyperthermia to cervical cancer. A constrained...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/13/014
更新日期:2011-07-07 00:00:00
abstract::Output normalized dose profiles for asymmetric open photon fields has been calculated using a commercial treatment planning system (TPS) based on a dose-to-energy-fluence concept. The model does not require any additional measurements for off-axis fields. Calculations are compared with measurements for quadratic field...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/41/8/003
更新日期:1996-08-01 00:00:00
abstract::This work aims to evaluate the predictive strength of the relative seriality, parallel and Lyman-Kutcher-Burman (LKB) normal tissue complication probability (NTCP) models regarding the incidence of radiation pneumonitis (RP), in a group of patients following lung cancer radiotherapy and also to examine their correlati...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/4/013
更新日期:2007-02-21 00:00:00
abstract::Mechanical properties of biological tissues are significant biomarkers for diagnosing various diseases. Assessing the viscoelastic properties of multi-layer tissues has remained challenging for a long time. Some shear wave models have been proposed to estimate thin-layer tissues' viscoelasticity recently. However, the...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/abca04
更新日期:2020-11-12 00:00:00
abstract::The total ionisation produced by ions stopped in nitrogen, methane and carbon dioxide has been measured in the energy range 25-375 keV using a chamber described previously. The chamber was operated alternately as a proportional counter and as an ionisation chamber to measure respectively the particle rate and the tota...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/25/3/010
更新日期:1980-05-01 00:00:00
abstract::A radiofrequency and field-gradient pulse sequence is presented permitting the non-invasive, volume-selective and spectroscopically resolved determination of incoherent transport parameters with the aid of an NMR field-gradient method. With proton NMR, diffusion or (quasi-incoherent) perfusion coefficients as low as 1...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/35/1/007
更新日期:1990-01-01 00:00:00
abstract::For quantitative measurements of small animals such as mice or rats, a compact and high sensitivity continuous blood sampling detector is required because their blood sampling volume is limited. For this purpose we have developed and tested a new positron detector. The positron detector uses a pair of dual-layer thin ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/13/016
更新日期:2010-07-07 00:00:00
abstract::This study introduces a practical four-dimensional (4D) planning scheme of IMAT using 4D computed tomography (4D CT) for planning tumor tracking with dynamic multileaf beam collimation. We assume that patients can breathe regularly, i.e. the same way as during 4D CT with an unchanged period and amplitude, and that the...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa56b7
更新日期:2017-02-21 00:00:00
abstract::The use of deformable image registration methods in the context of adaptive radiotherapy leads to uncertainties in the simulation of the administered dose distributions during the treatment course. Evaluation of these methods is a prerequisite to decide if a plan adaptation will improve the individual treatment. Curre...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa69b6
更新日期:2017-06-21 00:00:00
abstract::Range verification is one of the most relevant tasks in ion beam therapy. In the case of carbon ion therapy, positron emission tomography (PET) is the most widely used method for this purpose, which images the [Formula: see text]-activation following nuclear interactions of the ions with the tissue nuclei. Since the p...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab17f9
更新日期:2019-05-21 00:00:00
abstract::In this study, an induced electric field in a human body is evaluated for the magnetic field leaked from a wireless power transfer system for charging an electrical vehicle. The magnetic field from the wireless power transfer system is modelled computationally, and its effectiveness is confirmed by comparison with the...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/21/7583
更新日期:2013-11-07 00:00:00
abstract::This paper concerns the robustness of discrete wavelet transform (DWT) compression in terahertz pulsed imaging (TPI). TPI datasets consist of terahertz time-domain series which are sampled at each 'pixel' of the image, leading to file sizes which are typically of the order of several megabytes (MB) per image. This mak...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/47/21/328
更新日期:2002-11-07 00:00:00
abstract::Monte Carlo-based simulation of positron emission tomography (PET) data plays a key role in the design and optimization of data correction and processing methods. Our first aim was to adapt and configure the PET-SORTEO Monte Carlo simulation program for the geometry of the widely distributed Inveon PET preclinical sca...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/19/6749
更新日期:2013-10-07 00:00:00
abstract::Magnetic resonance-guided radiation therapy (MR-GRT) offers great potential to improve radiation treatment outcomes by providing more accurate and patient-tailored therapy. Despite superior soft tissue contrast in MRI, one of the challenges towards MRI-only workflows is that the process often requires some sort of 'MR...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab2623
更新日期:2019-07-16 00:00:00
abstract::Cardiac and respiratory motion artefacts in PET imaging have been traditionally resolved by acquiring the data in gated mode. However, gated PET images are usually characterized by high noise content due to their low photon statistics. In this paper, we present a novel 4D model for the PET imaging system, which can in...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/51/15/012
更新日期:2006-08-07 00:00:00
abstract::Novel x-ray medical imaging sensors, such as photon counting detectors (PCDs) and large area CCD and CMOS cameras can involve irregular and/or sparse sampling of the detector plane. Application of such detectors to CT involves undersampling that is markedly different from the commonly considered case of sparse angular...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/61/1/90
更新日期:2016-01-07 00:00:00