Measurement of the dielectric properties of the epidermis and dermis at frequencies from 0.5 GHz to 110 GHz.

Abstract:

:Numerous studies have reported the measurements of the dielectric properties of the skin. Clarifying the manner in which the human body interacts with electromagnetic waves is essential for medical research and development, as well as for the safety assessment of electromagnetic wave exposure. The skin comprises several layers: the epidermis, the dermis, and the subcutaneous fat. Each of these skin layers has a different constitution; however, the previous measurements of their dielectric properties were typically conducted on tissue which included all three layers of the skin. This study presents novel dielectric property data for the epidermis and dermis with in vitro measurement at frequencies ranging from 0.5 GHz to 110 GHz. Measured data was compared with literature values; in particular, the findings were compared with Gabriel's widely used data on skin dielectric properties. The experimental results agreed with the data reported by Gabriel for the dermis of up to 20 GHz, which is the upper limit of the range of frequencies at which Gabriel reported measurements. For frequencies of 20-100 GHz, the experimental results indicated larger values than those extrapolated from Gabriel's data using parametric expansion. For frequencies over 20 GHz, the dielectric properties provided by the parametric model tend toward the experimental results for the epidermis with increasing frequency.

journal_name

Phys Med Biol

authors

Sasaki K,Wake K,Watanabe S

doi

10.1088/0031-9155/59/16/4739

subject

Has Abstract

pub_date

2014-08-21 00:00:00

pages

4739-47

issue

16

eissn

0031-9155

issn

1361-6560

journal_volume

59

pub_type

杂志文章
  • Experimental characterization of lateral profiles of scanned proton and carbon ion pencil beams for improved beam models in ion therapy treatment planning.

    abstract::Scanned ion pencil beams carry a low-dose envelope which can extend up to several centimeters from the individual beam central axis. Depending on the energy and species of the beam, this halo consists mainly of secondary particles produced by nuclear interactions in the target or of particles undergoing multiple Coulo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/24/009

    authors: Schwaab J,Brons S,Fieres J,Parodi K

    更新日期:2011-12-21 00:00:00

  • The fast Padé transform in magnetic resonance spectroscopy for potential improvements in early cancer diagnostics.

    abstract::The convergence rates of the fast Padé transform (FPT) and the fast Fourier transform (FFT) are compared. These two estimators are used to process a time-signal encoded at 4 T by means of one-dimensional magnetic resonance spectroscopy (MRS) for healthy human brain. It is found systematically that at any level of trun...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/18/010

    authors: Belkić D,Belkić K

    更新日期:2005-09-21 00:00:00

  • Optimization-based image reconstruction with artifact reduction in C-arm CBCT.

    abstract::We investigate an optimization-based reconstruction, with an emphasis on image-artifact reduction, from data collected in C-arm cone-beam computed tomography (CBCT) employed in image-guided interventional procedures. In the study, an image to be reconstructed is formulated as a solution to a convex optimization progra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/20/7300

    authors: Xia D,Langan DA,Solomon SB,Zhang Z,Chen B,Lai H,Sidky EY,Pan X

    更新日期:2016-10-21 00:00:00

  • Comparison study of temporal regularization methods for fully 5D reconstruction of cardiac gated dynamic SPECT.

    abstract::Temporal regularization plays a critical role in cardiac gated dynamic SPECT reconstruction, of which the goal is to obtain an image sequence from a single acquisition which simultaneously shows both cardiac motion and tracer distribution change over the course of imaging (termed 5D). In our recent work, we explored t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/17/5523

    authors: Niu X,Yang Y,King MA

    更新日期:2012-09-07 00:00:00

  • Evaluating attenuation correction strategies in a dedicated, single-gantry breast PET-tomosynthesis scanner.

    abstract::We are developing a dedicated, combined breast positron emission tomography (PET)-tomosynthesis scanner. Both the PET and digital breast tomosynthesis (DBT) scanners are integrated in a single gantry to provide spatially co-registered 3D PET-tomosynthesis images. The DBT image will be used to identify the breast bound...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abc5a8

    authors: Krishnamoorthy S,Vent T,Barufaldi B,Maidment ADA,Karp JS,Surti S

    更新日期:2020-10-28 00:00:00

  • Semi-empirical formulation of multiple scattering for the Gaussian beam model of heavy charged particles stopping in tissue-like matter.

    abstract::Dose calculation for radiotherapy with protons and heavier ions deals with a large volume of path integrals involving a scattering power of body tissue. This work provides a simple model for such demanding applications. There is an approximate linearity between RMS end-point displacement and range of incident particle...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/5/N01

    authors: Kanematsu N

    更新日期:2009-03-07 00:00:00

  • Improved method of in vivo respiratory-gated micro-CT imaging.

    abstract::The presence of motion artifacts is a typical problem in thoracic imaging. However, synchronizing the respiratory cycle with computed tomography (CT) image acquisition can reduce these artifacts. We currently employ a method of in vivo respiratory-gated micro-CT imaging for small laboratory animals (mice). This proced...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/17/023

    authors: Walters EB,Panda K,Bankson JA,Brown E,Cody DD

    更新日期:2004-09-07 00:00:00

  • Clinical ultraviolet dosimetry with a CCD monochromator array spectroradiometer.

    abstract::Single monochromator charge-coupled device (CCD) array spectroradiometers have the advantage of ease of use and speed compared with double grating instruments. Their inherently inferior stray-light rejection, however, can critically affect their accuracy in phototherapy and research-related dosimetry applications. Thi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/18/026

    authors: Coleman A,Sarkany R,Walker S

    更新日期:2008-09-21 00:00:00

  • Determination of elemental tissue composition following proton treatment using positron emission tomography.

    abstract::Positron emission tomography (PET) has been suggested as an imaging technique for in vivo proton dose and range verification after proton induced-tissue activation. During proton treatment, irradiated tissue is activated and decays while emitting positrons. In this paper, we assessed the feasibility of using PET imagi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/11/3815

    authors: Cho J,Ibbott G,Gillin M,Gonzalez-Lepera C,Min CH,Zhu X,El Fakhri G,Paganetti H,Mawlawi O

    更新日期:2013-06-07 00:00:00

  • Beveled fiber-optic probe couples a ball lens for improving depth-resolved fluorescence measurements of layered tissue: Monte Carlo simulations.

    abstract::In this study, we evaluate the feasibility of designing a beveled fiber-optic probe coupled with a ball lens for improving depth-resolved fluorescence measurements of epithelial tissue using Monte Carlo (MC) simulations. The results show that by using the probe configuration with a beveled tip collection fiber and a f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/4/008

    authors: Jaillon F,Zheng W,Huang Z

    更新日期:2008-02-21 00:00:00

  • Kinetic filtering of [(18)F]Fluorothymidine in positron emission tomography studies.

    abstract::[(18)F]Fluorothymidine (FLT) is a cell proliferation marker that undergoes predominantly hepatic metabolism and therefore shows a high level of accumulation in the liver, as well as in rapidly proliferating tumours. Furthermore, the tracer's uptake is substantial in other organs including the heart. We present a nonli...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/3/010

    authors: Gray KR,Contractor KB,Kenny LM,Al-Nahhas A,Shousha S,Stebbing J,Wasan HS,Coombes RC,Aboagye EO,Turkheimer FE,Rosso L

    更新日期:2010-02-07 00:00:00

  • Evaluation of nonuniform field exposures with coupling factors.

    abstract::In this study, the safety compliance for nonuniform field exposures is discussed using coupling factor concepts. The coupling factor, which is defined in the International Electrotechnical Commission 62311 standard, is extended to consider the effects of harmonics and also to apply to the specific absorption rate (for...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/20/8129

    authors: Sunohara T,Hirata A,Laakso I,De Santis V,Onishi T

    更新日期:2015-10-21 00:00:00

  • Investigation of saddle trajectories for cardiac CT imaging in cone-beam geometry.

    abstract::This paper investigates cone-beam tomography for a wide class of x-ray source trajectories called saddles. In particular, a mathematical analysis of the number of intersections between a saddle and an arbitrary plane is given. This analysis demonstrates that axially truncated cone-beam projections acquired along a sad...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/11/014

    authors: Pack JD,Noo F,Kudo H

    更新日期:2004-06-07 00:00:00

  • Automated detection of clustered microcalcifications on mammograms: CAD system application to MIAS database.

    abstract::To investigate the detection performance of our automated detection scheme for clustered microcalcifications on mammograms, we applied our computer-aided diagnosis (CAD) system to the database of the Mammographic Image Analysis Society (MIAS) in the UK. Forty-three mammograms from this database were used in this study...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/12/021

    authors: Ibrahim N,Fujita H,Hara T,Endo T

    更新日期:1997-12-01 00:00:00

  • An integrated platform for image-guided cardiac resynchronization therapy.

    abstract::Cardiac resynchronization therapy (CRT) is an effective procedure for patients with heart failure but 30% of patients do not respond. This may be due to sub-optimal placement of the left ventricular (LV) lead. It is hypothesized that the use of cardiac anatomy, myocardial scar distribution and dyssynchrony information...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/10/2953

    authors: Ma YL,Shetty AK,Duckett S,Etyngier P,Gijsbers G,Bullens R,Schaeffter T,Razavi R,Rinaldi CA,Rhode KS

    更新日期:2012-05-21 00:00:00

  • Radioisotopic purity and imaging properties of cyclotron-produced 99mTc using direct 100Mo(p,2n) reaction.

    abstract::Evaluation of the radioisotopic purity of technetium-99m (99mTc) produced in GBq amounts by proton bombardment of enriched molibdenum-100 (100Mo) metallic targets at low proton energies (i.e. within 15-20 MeV) is conducted. This energy range was chosen since it is easily achievable by many conventional medical cyclotr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aadc88

    authors: Uzunov NM,Melendez-Alafort L,Bello M,Cicoria G,Zagni F,De Nardo L,Selva A,Mou L,Rossi-Alvarez C,Pupillo G,Di Domenico G,Uccelli L,Boschi A,Groppi F,Salvini A,Taibi A,Duatti A,Martini P,Pasquali M,Loriggiola M,Mare

    更新日期:2018-09-19 00:00:00

  • Absorbed dose beam quality correction factors kappaQ for the NE2571 chamber in a 5 MV and a 10 MV photon beam.

    abstract::Dose to water (Dw) determination in clinical high-energy photon beams with ionization chambers calibrated in terms of absorbed dose to water has been proposed as an alternative to ionization chamber dosimetry based on air kerma calibrations. Dw in the clinical beam is derived using a kappaQ factor that scales the abso...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/3/002

    authors: Palmans H,Mondelaers W,Thierens H

    更新日期:1999-03-01 00:00:00

  • Artefacts in multi-echo T2 imaging for high-precision gel dosimetry: I. Analysis and compensation of eddy currents.

    abstract::In BANG gel dosimetry, the spin-spin relaxation rate, R2 = I/T2, is related to the radiation dose that has been delivered to the gel phantom. R2 is calculated by fitting the pixel intensities of a set of differently T2-weighted base images. In gel dosimetry for radiotherapy, an accuracy of 5% in dose and 3 mm spatiall...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/7/307

    authors: De Deene Y,De Wagter C,De Neve W,Achten E

    更新日期:2000-07-01 00:00:00

  • Spectra from 2.5-15 microm of tissue phantom materials, optical clearing agents and ex vivo human skin: implications for depth profiling of human skin.

    abstract::Infrared measurements have been used to profile or image biological tissue, including human skin. Usually, analysis of such measurements has assumed that infrared absorption is due to water and collagen. Such an assumption may be reasonable for soft tissue, but introduction of exogenous agents into skin or the measure...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/2/402

    authors: Viator JA,Choi B,Peavy GM,Kimel S,Nelson JS

    更新日期:2003-01-21 00:00:00

  • Systematic investigation of the signal properties of polycrystalline HgI2 detectors under mammographic, radiographic, fluoroscopic and radiotherapy irradiation conditions.

    abstract::The signal properties of polycrystalline mercuric iodide (HgI2) film detectors, under irradiation conditions relevant to mammographic, radiographic, fluoroscopic and radiotherapy x-ray imaging, are reported. Each film detector consists of an approximately 230 to approximately 460 microm thick layer of HgI2 (fabricated...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/12/012

    authors: Su Z,Antonuk LE,El-Mohri Y,Hu L,Du H,Sawant A,Li Y,Wang Y,Yamamoto J,Zhao Q

    更新日期:2005-06-21 00:00:00

  • Monte Carlo study of x-ray detection configurations for benchtop x-ray fluorescence computed tomography of gold nanoparticle-loaded objects.

    abstract::Over the last decade, the performance of benchtop x-ray fluorescence computed tomography (XFCT) systems has been significantly enhanced through hardware and software optimizations. Recent studies have indicated the need of energy-resolving pixelated/array detectors in the x-ray detection component to further improve t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9774

    authors: Moktan H,Ahmed MF,Jayarathna S,Deng L,Cho SH

    更新日期:2020-08-31 00:00:00

  • Determination of fractional flow reserve (FFR) based on scaling laws: a simulation study.

    abstract::Fractional flow reserve (FFR) provides an objective physiological evaluation of stenosis severity. A technique that can measure FFR using only angiographic images would be a valuable tool in the cardiac catheterization laboratory. To perform this, the diseased blood flow can be measured with a first pass distribution ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/14/017

    authors: Wong JT,Molloi S

    更新日期:2008-07-21 00:00:00

  • Fast calibration of SPECT monolithic scintillation detectors using un-collimated sources.

    abstract::Monolithic scintillation detectors for positron emission tomography and single-photon emission computed tomography (SPECT) imaging have many advantages over pixelated detectors. The use of monolithic crystals allows for reducing the scintillator cost per unit volume and increasing the sensitivity along with the energy...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/14/4807

    authors: España S,Deprez K,Van Holen R,Vandenberghe S

    更新日期:2013-07-21 00:00:00

  • The gastrointestinal absorption of plutonium and americium in the hamster.

    abstract::Plutonium-239 and americium-241 were administered to adult hamsters in various chemical forms and their absorption from the gut was measured. The results have been compared with published data on other species in order to derive values for the estimated absorption of these actinides in man. On the basis of current kno...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/24/2/015

    authors: Stather JW,Harrison JD,Rodwell P,David AJ

    更新日期:1979-03-01 00:00:00

  • High spatial resolution quantitative MR images: an experimental study of dedicated surface coils.

    abstract::Measuring spin-spin relaxation times (T2) by quantitative MR imaging represents a potentially efficient tool to evaluate the physicochemical properties of various media. However, noise in MR images is responsible for uncertainties in the determination of T2 relaxation times, which limits the accuracy of parametric tis...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/11/011

    authors: Gensanne D,Josse G,Lagarde JM,Vincensini D

    更新日期:2006-06-07 00:00:00

  • Pulsed focused ultrasound lowers interstitial fluid pressure and increases nanoparticle delivery and penetration in head and neck squamous cell carcinoma xenograft tumors.

    abstract::Nanocarriers offer a promising approach to significantly improve therapeutic delivery to solid tumors as well as limit the side effects associated with anti-cancer agents. However, their relatively large size can negatively affect their ability to efficiently penetrate into more interior tumor regions, ultimately redu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9705

    authors: Mohammadabadi A,Huynh RN,Wadajkar AS,Lapidus RG,Kim AJ,Raub CB,Frenkel V

    更新日期:2020-06-22 00:00:00

  • A robust optimization method for weighted-layer-stacking proton beam therapy.

    abstract::The layer-stacking method can provide three-dimensional conformal dose distributions to the target based on a passive scattering method using mini-spread-out Bragg peak (SOBP). The purpose of this work is to demonstrate the effectiveness of a new weight optimization algorithm that can enhance the robustness of dose di...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9efd

    authors: Sakamoto Y,Maeda Y,Yamada Y,Ikeda M,Tameshige Y,Sasaki M,Shibata S,Yamamoto K

    更新日期:2020-09-28 00:00:00

  • Perturbation correction for alanine dosimeters in different phantom materials in high-energy photon beams.

    abstract::In modern radiotherapy the verification of complex treatments plans is often performed in inhomogeneous or even anthropomorphic phantoms. For dose verification small detectors are necessary and therefore alanine detectors are most suitable. Though the response of alanine for a wide range of clinical photon energies in...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/3/N70

    authors: von Voigts-Rhetz P,Anton M,Vorwerk H,Zink K

    更新日期:2016-02-07 00:00:00

  • An investigation of automatic exposure control calibration for chest imaging with a computed radiography system.

    abstract::The purpose of this study was to examine the use of three physical image quality metrics in the calibration of an automatic exposure control (AEC) device for chest radiography with a computed radiography (CR) imaging system. The metrics assessed were signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and mean ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/9/2307

    authors: Moore CS,Wood TJ,Avery G,Balcam S,Needler L,Beavis AW,Saunderson JR

    更新日期:2014-05-07 00:00:00

  • Spiraling contaminant electrons increase doses to surfaces outside the photon beam of an MRI-linac with a perpendicular magnetic field.

    abstract::The transverse magnetic field of an MRI-linac sweeps contaminant electrons away from the radiation beam. Films oriented perpendicular to the magnetic field and 5 cm from the radiation beam edge show a projection of the divergent beam, indicating that contaminant electrons spiral along magnetic field lines and deposit ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaba8f

    authors: Hackett SL,van Asselen B,Wolthaus JWH,Bluemink JJ,Ishakoglu K,Kok J,Lagendijk JJW,Raaymakers BW

    更新日期:2018-05-01 00:00:00