A water calorimeter for neutron dosimetry.

Abstract:

:A water calorimeter has been used for the direct measurement of absorbed dose to water in a d(15) + Be neutron beam. The absorbed dose measured with the calorimeter was compared with that measured with an Exradin ionisation chamber, constructed of A-150 plastic. The doses measured by the ionisation chamber were calculated according to the European (ECNEU) protocol. Absorbed dose to tissue measured with the calorimeter was 4.3% lower than that measured with the ionisation chamber. Relative to ionisation chamber dosimetry, dose measurements with the calorimeter in the neutron beam were 9% lower than similar measurements in 4 and 9 MV photon beams. The significance of the results is discussed in terms of the heat defect in water.

journal_name

Phys Med Biol

authors

Galloway G,Greening JR,Williams JR

doi

10.1088/0031-9155/31/4/005

subject

Has Abstract

pub_date

1986-04-01 00:00:00

pages

397-406

issue

4

eissn

0031-9155

issn

1361-6560

journal_volume

31

pub_type

杂志文章
  • Numerical considerations for interface reflections in medical ultrasound.

    abstract::The original concept of the echo mechanism in diagnostic medical ultrasound--of step impedance discontinuities--is investigated in terms of the numerical implications of more refined models. The effect of a discontinuity in the attenuation coefficients is found to have as much significance as the impedance discontinui...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/8/001

    authors: Chivers RC,Santosa F

    更新日期:1986-08-01 00:00:00

  • Using mathematical morphology to determine left ventricular contours.

    abstract::The aim of this study is to investigate the use of mathematical morphology for the determination of left ventricular contours in scintigraphic images using multigated radionuclide angiography. We have developed a completely automatic method that first restores the image with a Wiener filter, then finds the region wher...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/38/12/012

    authors: Pladellorens J,Serrat J,Castell A,Yzuel MJ

    更新日期:1993-12-01 00:00:00

  • Motion induced interplay effects for VMAT radiotherapy.

    abstract::The purpose of this study was to develop a method to simulate breathing motion induced interplay effects for volumetric modulated arc therapy (VMAT), to verify the proposed method with measurements, and to use the method to investigate how interplay effects vary with different patient- and machine specific parameters....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aab957

    authors: Edvardsson A,Nordström F,Ceberg C,Ceberg S

    更新日期:2018-04-19 00:00:00

  • Impact of the displacement current on low-frequency electromagnetic fields computed using high-resolution anatomy models.

    abstract::We present a comparison of simulated low-frequency electromagnetic fields in the human body, calculated by means of the electro-quasistatic formulation. The geometrical data in these simulations were provided by an anatomically realistic, high-resolution human body model, while the dielectric properties of the various...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/19/N02

    authors: Barchanski A,De Gersem H,Gjonaj E,Weiland T

    更新日期:2005-10-07 00:00:00

  • Fibre-optic sensors in health care.

    abstract::Biomedical fibre-optic sensors are attractive for the measurement of physical, chemical and biochemical parameters and for spectral measurements directly performed on the patient. An overview of fibre-optic sensors for in vivo monitoring is given, with particular attention paid to the advantages that these sensors are...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/42/5/015

    authors: Mignani AG,Baldini F

    更新日期:1997-05-01 00:00:00

  • Evaluation of radiochromic gel dosimetry and polymer gel dosimetry in a clinical dose verification.

    abstract::A quantitative comparison of two full three-dimensional (3D) gel dosimetry techniques was assessed in a clinical setting: radiochromic gel dosimetry with an in-house developed optical laser CT scanner and polymer gel dosimetry with magnetic resonance imaging (MRI). To benchmark both gel dosimeters, they were exposed t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/18/6241

    authors: Vandecasteele J,De Deene Y

    更新日期:2013-09-21 00:00:00

  • Inclusion of thin target and source regions in alimentary and respiratory tract systems of mesh-type ICRP adult reference phantoms.

    abstract::It is not feasible to define very small or complex organs and tissues in the current voxel-type adult reference computational phantoms of the International Commission on Radiological Protection (ICRP), which limit dose coefficients for weakly penetrating radiations. To address the problem, the ICRP is converting the v...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5b72

    authors: Kim HS,Yeom YS,Nguyen TT,Choi C,Han MC,Lee JK,Kim CH,Zankl M,Petoussi-Henss N,Bolch WE,Lee C,Qiu R,Eckerman K,Chung BS

    更新日期:2017-03-21 00:00:00

  • STIR: software for tomographic image reconstruction release 2.

    abstract::We present a new version of STIR (Software for Tomographic Image Reconstruction), an open source object-oriented library implemented in C++ for 3D positron emission tomography reconstruction. This library has been designed such that it can be used for many algorithms and scanner geometries, while being portable to var...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/4/867

    authors: Thielemans K,Tsoumpas C,Mustafovic S,Beisel T,Aguiar P,Dikaios N,Jacobson MW

    更新日期:2012-02-21 00:00:00

  • Fluence correction factors in plastic phantoms for clinical proton beams.

    abstract::In recent codes of practice for reference dosimetry in clinical proton beams using ionization chambers, it is recommended to perform the measurement in a water phantom. However, in situations where the positioning accuracy is very critical, it could be more convenient to perform the measurement in a plastic phantom. I...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/17/302

    authors: Palmans H,Symons JE,Denis JM,de Kock EA,Jones DT,Vynckier S

    更新日期:2002-09-07 00:00:00

  • Integral equations and boundary-element solution for static potential in a general piece-wise homogeneous volume conductor.

    abstract::Boundary element methods (BEM) are used for forward computation of bioelectromagnetic fields in multi-compartment volume conductor models. Most BEM approaches assume that each compartment is in contact with at most one external compartment. In this work, I present a general surface integral equation and BEM discretiza...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/22/N606

    authors: Stenroos M

    更新日期:2016-11-21 00:00:00

  • FDTD analysis of human body-core temperature elevation due to RF far-field energy prescribed in the ICNIRP guidelines.

    abstract::This study investigated the relationship between the specific absorption rate and temperature elevation in an anatomically-based model named NORMAN for exposure to radio-frequency far fields in the ICNIRP guidelines (1998 Health Phys. 74 494-522). The finite-difference time-domain method is used for analyzing the elec...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/16/020

    authors: Hirata A,Asano T,Fujiwara O

    更新日期:2007-08-21 00:00:00

  • Influence of the SURLAS applicator on radiation dose distributions during simultaneous thermoradiotherapy with helical tomotherapy.

    abstract::Simultaneous thermoradiotherapy has been shown to maximize the effect of hyperthermia as a radiation sensitizer in cancer treatment. Here we follow our previous work on feasibility of thermoradiotherapy with the scanning ultrasound reflector linear array system (SURLAS) and TomoTherapy HiArt treatment system, and inve...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/10/004

    authors: Novák P,Peñagarícano JA,Nahirnyak V,Corry P,Moros EG

    更新日期:2008-05-21 00:00:00

  • Power deposition in the head and neck of an anatomically based human body model for plane wave exposures.

    abstract::At certain frequencies, when the human head becomes a resonant structure, the power absorbed by the head and neck, when the body is exposed to a vertically polarized plane wave propagating from front to back, becomes significantly larger than would ordinarily be expected from its shadow cross section. This has possibl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/8/026

    authors: Tinniswood AD,Furse CM,Gandhi OP

    更新日期:1998-08-01 00:00:00

  • First in-beam PET measurement of beta+ radioactivity induced by hard photon beams.

    abstract::In this note, we present the first experimental results of in-beam PET measurements during high energy photon phantom irradiation. An inhomogeneous phantom was irradiated with pulsed 34 MV bremsstrahlung. The measurements have been conducted with a dedicated double head positron camera. A high material contrast could ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/20/N01

    authors: Kluge T,Möckel D,Pawelke J,Enghardt W

    更新日期:2007-10-21 00:00:00

  • Broadband ultrasound attenuation imaging: algorithm development and clinical assessment of a region growing technique.

    abstract::This paper presents a computerized method for the selection of an irregular region of interest (ROI) in broadband ultrasound attenuation (BUA) images. A region growing algorithm searches an initial region in the posterior part of the calcaneus until the pixel with the lowest attenuation value is found; this is the sta...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/2/310

    authors: Damilakis J,Stratakis J,Perisinakis K,Gourtsoyiannis N

    更新日期:2002-01-21 00:00:00

  • Development and validation of RAYDOSE: a Geant4-based application for molecular radiotherapy.

    abstract::We developed and validated a Monte-Carlo-based application (RAYDOSE) to generate patient-specific 3D dose maps on the basis of pre-treatment imaging studies. A CT DICOM image is used to model patient geometry, while repeated PET scans are employed to assess radionuclide kinetics and distribution at the voxel level. In...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/8/2491

    authors: Marcatili S,Pettinato C,Daniels S,Lewis G,Edwards P,Fanti S,Spezi E

    更新日期:2013-04-21 00:00:00

  • A method of improving the spatial resolution of treatments that involve a multileaf collimator.

    abstract::In this paper we present a novel method of reducing the dosimetric effects of the finite leaf width of a multileaf collimator (MLC) in conformal and intensity modulated radiotherapy (IMRT). This is achieved by decomposing the required high-resolution fluence distribution into two orthogonal components, which are deliv...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/3/304

    authors: Evans PM,Partridge M

    更新日期:2000-03-01 00:00:00

  • Fricke dosimetry: the difference between G(Fe3+) for 60Co gamma-rays and high-energy x-rays.

    abstract::A calibration of the Fricke dosimeter is a measurement of epsilon G(Fe3+). Although G(Fe3+) is expected to be approximately energy independent for all low-LET radiation, existing data are not adequate to rule out the possibility of changes of a few per cent with beam quality. When a high-precision Fricke dosimeter, wh...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/7/303

    authors: Klassen NV,Shortt KR,Seuntjens J,Ross CK

    更新日期:1999-07-01 00:00:00

  • Pre-optimization of radiotherapy treatment planning: an artificial neural network classification aided technique.

    abstract::A method has been developed which, by using the geometric information from treatment sample cases, selects from a given data set an initial treatment plan as a step for treatment plan optimization. The method uses an artificial neural network (ANN) classification technique to select a best matching plan from the 'opti...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/6/306

    authors: Hosseini-Ashrafi ME,Bagherebadian H,Yahaqi E

    更新日期:1999-06-01 00:00:00

  • Investigation of saddle trajectories for cardiac CT imaging in cone-beam geometry.

    abstract::This paper investigates cone-beam tomography for a wide class of x-ray source trajectories called saddles. In particular, a mathematical analysis of the number of intersections between a saddle and an arbitrary plane is given. This analysis demonstrates that axially truncated cone-beam projections acquired along a sad...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/11/014

    authors: Pack JD,Noo F,Kudo H

    更新日期:2004-06-07 00:00:00

  • Depth of ionization chamber in water.

    abstract::The device developed by the authors and described here enables the user to measure the depth from the water surface to the point of measurement for a cylindrical ion chamber with a waterproof plastic cap in a water phantom, free of surface-tension error with a high precision. The device seeks vertical orientation and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/8/007

    authors: Tailor RC,Tello VM

    更新日期:1995-08-01 00:00:00

  • The replacement correction factors for cylindrical chambers in high-energy photon beams.

    abstract::The values of the replacement correction factors (P(repl), or in the IAEA's notation p(dis)p(cav)) used for cylindrical chambers in high-energy photon beams represent one of the most significant differences between the AAPM and the IAEA dosimetry protocols. In a previous study (Wang L L W and Rogers D W O 2008 Med. Ph...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/6/014

    authors: Wang LL,Rogers DW

    更新日期:2009-03-21 00:00:00

  • A promising new mechanism of ionizing radiation detection for positron emission tomography: modulation of optical properties.

    abstract::Using conventional scintillation detection, the fundamental limit in positron emission tomography (PET) time resolution is strongly dependent on the inherent temporal variances generated during the scintillation process, yielding an intrinsic physical limit for the coincidence time resolution of around 100 ps. On the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/21/7600

    authors: Tao L,Daghighian HM,Levin CS

    更新日期:2016-11-07 00:00:00

  • A Monte Carlo-based method to estimate radiation dose from spiral CT: from phantom testing to patient-specific models.

    abstract::The purpose of this work is to develop and test a method to estimate the relative and absolute absorbed radiation dose from axial and spiral CT scans using a Monte Carlo approach. Initial testing was done in phantoms and preliminary results were obtained from a standard mathematical anthropomorphic model (MIRD V) and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/16/306

    authors: Jarry G,DeMarco JJ,Beifuss U,Cagnon CH,McNitt-Gray MF

    更新日期:2003-08-21 00:00:00

  • Dose conversion coefficients for paediatric CT examinations with automatic tube current modulation.

    abstract::A common dose-saving technique used in modern CT devices is automatic tube current modulation (TCM), which was originally designed to also reduce the dose in paediatric CT patients. In order to be able to deduce detailed organ doses of paediatric models, dose conversion coefficients normalized to CTDI(vol) for an eigh...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/20/6309

    authors: Schlattl H,Zankl M,Becker J,Hoeschen C

    更新日期:2012-10-21 00:00:00

  • Photoluminescent thermometry based on europium-activated calcium sulphide.

    abstract::A photoluminescent thermometer, based on the transient emission response of a europium-activated calcium sulphide phosphor, is described in detail. This optical thermometry system has special advantages for temperature measurements in microwave and RF fields and potential application in electromagnetically induced cli...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/27/1/011

    authors: Samulski TV,Chopping PT,Haas B

    更新日期:1982-01-01 00:00:00

  • A comparison of 60 Hz uniform magnetic and electric induction in the human body.

    abstract::High-resolution computations of induced fields are used to assess equivalent source levels for human exposure to uniform low-frequency electric and magnetic fields. These results pertain to 60 Hz foot-to-head electric excitation of the body in three positions with respect to a ground plane, and to magnetic excitation ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/12/001

    authors: Dawson TW,Caputa K,Stuchly MA

    更新日期:1997-12-01 00:00:00

  • Effect of inter-crystal scatter on estimation methods for random coincidences and subsequent correction.

    abstract::Random coincidences can contribute substantially to the background in positron emission tomography (PET). Several estimation methods are being used for correcting them. The goal of this study was to investigate the validity of techniques for random coincidence estimation, with various low-energy thresholds (LETs). Sim...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/9/012

    authors: Torres-Espallardo I,Rafecas M,Spanoudaki V,McElroy DP,Ziegler SI

    更新日期:2008-05-07 00:00:00

  • A fast and sensitive TLD method for measurement of energy and homogeneity of electron beams using transmitted radiation through lead.

    abstract::A simple and fast, but sensitive TLD method for the measurement of energy and homogeneity of therapeutically used electron beams has been developed and tested. This method is based on the fact that when small thicknesses of high-Z absorbers such as lead are interposed in the high-energy electron beams, the transmitted...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/9/005

    authors: Pradhan AS,Quast U,Sharma PK

    更新日期:1994-09-01 00:00:00

  • The Fokker-Planck equation for coupled Brown-Néel-rotation.

    abstract::Calculating the dynamic properties of magnetization of single-domain particles is of great importance for the tomographic imaging modality known as magnetic particle imaging (MPI). Although the assumption of instantaneous thermodynamic equilibrium (Langevin function) after application of time-dependent magnetic fields...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa186

    authors: Weizenecker J

    更新日期:2018-01-22 00:00:00