Large-angle x-ray scatter in Talbot-Lau interferometry for breast imaging.

Abstract:

:Monte Carlo simulations were used to investigate large-angle x-ray scatter at design energy of 25 keV during small field of view (9.6 cm × 5 cm) differential phase contrast imaging of the breast using Talbot-Lau interferometry. Homogenous, adipose and fibroglandular breasts of uniform thickness ranging from 2 to 8 cm encompassing the field of view were modeled. Theoretically determined transmission efficiencies of the gratings were used to validate the Monte Carlo simulations, followed by simulations to determine the x-ray scatter reaching the detector. The recorded x-ray scatter was classified into x-ray photons that underwent at least one Compton interaction (incoherent scatter) and Rayleigh interaction alone (coherent scatter) for further analysis. Monte Carlo based estimates of transmission efficiencies showed good correspondence [Formula: see text] with theoretical estimates. Scatter-to-primary ratio increased with increasing breast thickness, ranging from 0.11 to 0.22 for 2-8 cm thick adipose breasts and from 0.12 to 0.28 for 2-8 cm thick fibroglandular breasts. The analyzer grating reduced incoherent scatter by ~18% for 2 cm thick adipose breast and by ~35% for 8 cm thick fibroglandular breast. Coherent scatter was the dominant contributor to the total scatter. Coherent-to-incoherent scatter ratio ranged from 2.2 to 3.1 for 2-8 cm thick adipose breasts and from 2.7 to 3.4 for 2-8 cm thick fibroglandular breasts.

journal_name

Phys Med Biol

authors

Vedantham S,Shi L,Karellas A

doi

10.1088/0031-9155/59/21/6387

subject

Has Abstract

pub_date

2014-11-07 00:00:00

pages

6387-400

issue

21

eissn

0031-9155

issn

1361-6560

journal_volume

59

pub_type

杂志文章
  • Assessment of rigid multi-modality image registration consistency using the multiple sub-volume registration (MSR) method.

    abstract::Registration of different imaging modalities such as CT, MRI, functional MRI (fMRI), positron (PET) and single photon (SPECT) emission tomography is used in many clinical applications. Determining the quality of any automatic registration procedure has been a challenging part because no gold standard is available to e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/10/N01

    authors: Ceylan C,van der Heide UA,Bol GH,Lagendijk JJ,Kotte AN

    更新日期:2005-05-21 00:00:00

  • Effect of blood perfusion on the ablation of liver parenchyma with high-intensity focused ultrasound.

    abstract::This paper discusses the effect of blood perfusion on the ablation of rat liver tissue with high-intensity focused ultrasound (HIFU). For this study a practical method has been developed, in which the liver blood flow can be reduced by ligation of the hepatic artery and portal vein. During the treatment the rat liver ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/38/11/011

    authors: Chen L,ter Haar G,Hill CR,Dworkin M,Carnochan P,Young H,Bensted JP

    更新日期:1993-11-01 00:00:00

  • Characterization of the electromagnetic near-field absorption in layered biological tissue in the frequency range from 30 MHz to 6,000 MHz.

    abstract::Currently, standards for the compliance testing of wireless devices are being extended to cover a wider frequency band and different usage patterns of mobile phones as well as of novel body-worn and handheld devices. As a consequence, not only the head but also strongly varying tissue distributions of the body are exp...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/19/014

    authors: Christ A,Samaras T,Klingenböck A,Kuster N

    更新日期:2006-10-07 00:00:00

  • 4D digital tomosynthesis image reconstruction using brute force-based adaptive total variation (BF-ATV) in a prototype LINAC system.

    abstract::Respiratory-correlated cone-beam CT (CBCT) not only inhibits rapid scanning due to the slow speed of the LINAC head gantry rotation, but its implementation for routine patient imaging is impractical because of the high radiation dose delivered during the process. Digital tomosynthesis (DTS) is a potentially faster tec...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab0d50

    authors: Choi S,Lee S,Kang YN,Hsieh SS,Kim HJ

    更新日期:2019-05-02 00:00:00

  • Monte Carlo study of x-ray detection configurations for benchtop x-ray fluorescence computed tomography of gold nanoparticle-loaded objects.

    abstract::Over the last decade, the performance of benchtop x-ray fluorescence computed tomography (XFCT) systems has been significantly enhanced through hardware and software optimizations. Recent studies have indicated the need of energy-resolving pixelated/array detectors in the x-ray detection component to further improve t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9774

    authors: Moktan H,Ahmed MF,Jayarathna S,Deng L,Cho SH

    更新日期:2020-08-31 00:00:00

  • MR-based keyhole SPECT for small animal imaging.

    abstract::The rationale for multi-modality imaging is to integrate the strengths of different imaging technologies while reducing the shortcomings of an individual modality. The work presented here proposes a limited-field-of-view (LFOV) SPECT reconstruction technique that can be implemented on a multi-modality MR/SPECT system ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/3/010

    authors: Lee KS,Roeck WW,Gullberg GT,Nalcioglu O

    更新日期:2011-02-07 00:00:00

  • Two-dimensional and quasi-three-dimensional dosimetry of hadron and photon beams with the Magic Cube and the Pixel Ionization Chamber.

    abstract::Two detectors for fast two-dimensional (2D) and quasi-three-dimensional (quasi-3D) verification of the dose delivered by radiotherapy beams have been developed at University and Istituto Nazionale di Fisica Nucleare (INFN) of Torino. The Magic Cube is a stack of strip-segmented ionization chambers interleaved with wat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/16/017

    authors: Cirio R,Garelli E,Schulte R,Amerio S,Boriano A,Bourhaleb F,Coutrakon G,Donetti M,Giordanengo S,Koss P,Madon E,Marchetto F,Nastasi U,Peroni C,Santuari D,Sardo A,Scielzo G,Stasi M,Trevisiol E

    更新日期:2004-08-21 00:00:00

  • Application of a CCD linear array camera in the quantification of tissue staining: NBT detection in ischaemic myocardium.

    abstract::A method was developed to quantify the intensity of tissue staining using a CCD (charge-coupled device) camera. Reflection spectra of NBT-stained (nitro-blue tetrazolium-stained) and unstained myocardium were recorded via fibre optics coupled to a CCD camera, connected to a microcomputer. The calculation of the intens...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/6/007

    authors: Schröder T,Koch G,Schnabel PA,Hering JP,Bretschneider HJ,Richter J,Hellige G

    更新日期:1991-06-01 00:00:00

  • Image-based point spread function implementation in a fully 3D OSEM reconstruction algorithm for PET.

    abstract::The interest in positron emission tomography (PET) and particularly in hybrid integrated PET/CT systems has significantly increased in the last few years due to the improved quality of the obtained images. Nevertheless, one of the most important limits of the PET imaging technique is still its poor spatial resolution ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/14/012

    authors: Rapisarda E,Bettinardi V,Thielemans K,Gilardi MC

    更新日期:2010-07-21 00:00:00

  • A Fourier rebinning algorithm incorporating spectral transfer efficiency for 3D PET.

    abstract::This paper presents a Fourier rebinning algorithm for three-dimensional image reconstruction in PET that incorporates the concept of spectral transfer function. It suggests the need for discarding low-frequency components in the rebinning. It also includes the correction for rebinning efficiency which was evaluated by...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/4/004

    authors: Tanaka E,Amo Y

    更新日期:1998-04-01 00:00:00

  • Automatic classification of DMSA scans using an artificial neural network.

    abstract::DMSA imaging is carried out in nuclear medicine to assess the level of functional renal tissue in patients. This study investigated the use of an artificial neural network to perform diagnostic classification of these scans. Using the radiological report as the gold standard, the network was trained to classify DMSA s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/7/1789

    authors: Wright JW,Duguid R,McKiddie F,Staff RT

    更新日期:2014-04-07 00:00:00

  • Experimental verification of numerical simulations of cryosurgery with application to computerized planning.

    abstract::As a part of an ongoing effort to develop computerized planning tools for cryosurgery, an experimental study has been conducted to verify a recently developed numerical technique for bioheat transfer simulations. Experiments were performed on gelatin solution as a phantom material, using proprietary liquid-nitrogen cr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/15/013

    authors: Rossi MR,Rabin Y

    更新日期:2007-08-07 00:00:00

  • Determination of some parameters for pion radiobiology studies.

    abstract::An experimental investigation of the central axis depth-dose and stopping rate distribution of the SIN biomedical pion beam is reported. The pion stopping rate in a thin disc of tissue-equivalent plastic was determined using a counter telescope. The dose rate at the position of this dic 'target' was measured using a s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/22/3/007

    authors: Nordell B,Baarli J,Sullivan AH,Zielczynski M

    更新日期:1977-05-01 00:00:00

  • Measuring the imaged-object distance with a stationary high-spatial-resolution scintillation camera.

    abstract::A method to measure the detector-to-object distance from the images obtained with stationary high-spatial-resolution gamma-ray cameras for in vivo studies has been developed. It exploits the shift of the imaged object in the image plane, obtained at a certain tilt of the parallel-hole collimator. A linear dependence o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/9/N04

    authors: Uzunov N,Bello M,Boccaccio P,Moschini G,Bollini D,de Notaristefani F

    更新日期:2006-05-07 00:00:00

  • Automated 3D ultrasound image analysis for first trimester assessment of fetal health.

    abstract::The first trimester fetal ultrasound scan is important to confirm fetal viability, to estimate the gestational age of the fetus, and to detect fetal anomalies early in pregnancy. First trimester ultrasound images have a different appearance than for the second trimester scan, reflecting the different stage of fetal de...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab3ad1

    authors: Ryou H,Yaqub M,Cavallaro A,Papageorghiou AT,Alison Noble J

    更新日期:2019-09-17 00:00:00

  • Coverage-based constraints for IMRT optimization.

    abstract::Radiation therapy treatment planning requires an incorporation of uncertainties in order to guarantee an adequate irradiation of the tumor volumes. In current clinical practice, uncertainties are accounted for implicitly with an expansion of the target volume according to generic margin recipes. Alternatively, it is p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa8132

    authors: Mescher H,Ulrich S,Bangert M

    更新日期:2017-09-05 00:00:00

  • Integral equations and boundary-element solution for static potential in a general piece-wise homogeneous volume conductor.

    abstract::Boundary element methods (BEM) are used for forward computation of bioelectromagnetic fields in multi-compartment volume conductor models. Most BEM approaches assume that each compartment is in contact with at most one external compartment. In this work, I present a general surface integral equation and BEM discretiza...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/22/N606

    authors: Stenroos M

    更新日期:2016-11-21 00:00:00

  • A 4D biomechanical lung phantom for joint segmentation/registration evaluation.

    abstract::At present, there exists few openly available methods for evaluation of simultaneous segmentation and registration algorithms. These methods allow for a combination of both techniques to track the tumor in complex settings such as adaptive radiotherapy. We have produced a quality assurance platform for evaluating this...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/19/7012

    authors: Markel D,Levesque I,Larkin J,Léger P,El Naqa I

    更新日期:2016-10-07 00:00:00

  • A framework for organ dose estimation in x-ray angiography and interventional radiology based on dose-related data in DICOM structured reports.

    abstract::Although interventional x-ray angiography (XA) procedures involve relatively high radiation doses that can lead to deterministic tissue reactions in addition to stochastic effects, convenient and accurate estimation of absorbed organ doses has traditionally been out of reach. This has mainly been due to the absence of...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/8/3063

    authors: Omar A,Bujila R,Fransson A,Andreo P,Poludniowski G

    更新日期:2016-04-21 00:00:00

  • A search for improved technique factors in paediatric fluoroscopy.

    abstract::A Monte Carlo computational model of a fluoroscopic imaging chain was used for deriving optimal technique factors for paediatric fluoroscopy. The optimal technique was defined as the one that minimizes the absorbed dose (or dose rate) in the patient with a constraint of constant image quality. Image quality was assess...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/2/018

    authors: Tapiovaara MJ,Sandborg M,Dance DR

    更新日期:1999-02-01 00:00:00

  • Dose-volume histogram prediction using density estimation.

    abstract::Knowledge of what dose-volume histograms can be expected for a previously unseen patient could increase consistency and quality in radiotherapy treatment planning. We propose a machine learning method that uses previous treatment plans to predict such dose-volume histograms. The key to the approach is the framing of d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/17/6923

    authors: Skarpman Munter J,Sjölund J

    更新日期:2015-09-07 00:00:00

  • Evaluation of transmission methodology and attenuation correction for the microPET Focus 220 animal scanner.

    abstract::An accurate, low noise estimate of photon attenuation in the subject is required for quantitative microPET studies of molecular tracer distributions in vivo. In this work, several transmission-based measurement techniques were compared, including coincidence mode with and without rod windowing, singles mode with two d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/16/008

    authors: Lehnert W,Meikle SR,Siegel S,Newport D,Banati RB,Rosenfeld AB

    更新日期:2006-08-21 00:00:00

  • Modeling localized delivery of Doxorubicin to the brain following focused ultrasound enhanced blood-brain barrier permeability.

    abstract::Doxorubicin (Dox) is a well-established chemotherapeutic agent, however it has limited efficacy in treating brain malignancies due to the presence of the blood-brain barrier (BBB). Recent preclinical studies have demonstrated that focused ultrasound induced BBB disruption (BBBD) enables efficient delivery of Dox to th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/20/5987

    authors: Nhan T,Burgess A,Lilge L,Hynynen K

    更新日期:2014-10-21 00:00:00

  • Automatic generation of time resolved motion vector fields of coronary arteries and 4D surface extraction using rotational x-ray angiography.

    abstract::Rotational coronary angiography provides a multitude of x-ray projections of the contrast agent enhanced coronary arteries along a given trajectory with parallel ECG recording. These data can be used to derive motion information of the coronary arteries including vessel displacement and pulsation. In this paper, a ful...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/1/004

    authors: Jandt U,Schäfer D,Grass M,Rasche V

    更新日期:2009-01-07 00:00:00

  • Magnetic resonance electrical property mapping at 21.1 T: a study of conductivity and permittivity in phantoms, ex vivo tissue and in vivo ischemia.

    abstract::Electrical properties (EP), namely conductivity and permittivity, can provide endogenous contrast for tissue characterization. Using electrical property tomography (EPT), maps of EP can be generated from conventional MRI data. This report investigates the feasibility and accuracy of EPT at 21.1 T for multiple RF coils...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab3259

    authors: Amouzandeh G,Mentink-Vigier F,Helsper S,Bagdasarian FA,Rosenberg JT,Grant SC

    更新日期:2020-02-28 00:00:00

  • Broadband ultrasound attenuation imaging: algorithm development and clinical assessment of a region growing technique.

    abstract::This paper presents a computerized method for the selection of an irregular region of interest (ROI) in broadband ultrasound attenuation (BUA) images. A region growing algorithm searches an initial region in the posterior part of the calcaneus until the pixel with the lowest attenuation value is found; this is the sta...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/2/310

    authors: Damilakis J,Stratakis J,Perisinakis K,Gourtsoyiannis N

    更新日期:2002-01-21 00:00:00

  • Beam data measurements for dynamic wedges on Varian 600C (6 MV) and 2100C (6 and 10 MV) linear accelerators.

    abstract::The measurement of beam data for dynamic wedge dosimetry requires the integration of radiation dose at points across the radiation field during the dose delivery. The different measurement techniques required when using a linear diode array to measure beam profiles and when using ionization chambers to measure depth d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/3/005

    authors: Bidmead AM,Garton AJ,Childs PJ

    更新日期:1995-03-01 00:00:00

  • Residual motion compensation in ECG-gated interventional cardiac vasculature reconstruction.

    abstract::Three-dimensional reconstruction of cardiac vasculature from angiographic C-arm CT (rotational angiography) data is a major challenge. Motion artefacts corrupt image quality, reducing usability for diagnosis and guidance. Many state-of-the-art approaches depend on retrospective ECG-gating of projection data for image ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/11/3717

    authors: Schwemmer C,Rohkohl C,Lauritsch G,Müller K,Hornegger J

    更新日期:2013-06-07 00:00:00

  • The replacement correction factors for cylindrical chambers in high-energy photon beams.

    abstract::The values of the replacement correction factors (P(repl), or in the IAEA's notation p(dis)p(cav)) used for cylindrical chambers in high-energy photon beams represent one of the most significant differences between the AAPM and the IAEA dosimetry protocols. In a previous study (Wang L L W and Rogers D W O 2008 Med. Ph...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/6/014

    authors: Wang LL,Rogers DW

    更新日期:2009-03-21 00:00:00

  • The production of positron emitters with millisecond half-life during helium beam radiotherapy.

    abstract::Therapy with helium ions is currently receiving significantly increasing interest because helium ions have a sharper penumbra than protons and undergo less fragmentation than carbon ions and thus require less complicated dose calculations. For any ion of interest in hadron therapy, the accuracy of dose delivery is lim...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab51c3

    authors: Ozoemelam I,van der Graaf E,Brandenburg S,Dendooven P

    更新日期:2019-12-05 00:00:00